California Building Standards Code
2025 California Fire Code (Title 24, Part 9)
Part 9 of Title 24 — Fire prevention, protection systems and life-safety requirements.
- Edition
- 2025
- Effective
- 2026-01-01
- Last ingested
- 2026-07-07
- Contents
- 55 chapters · 571 sections
- Jurisdiction
- California
Browse the full structure below. The verbatim text of this code is available through GoCodebook AI answers with exact section citations.
Contents
-
▸ Chapter 1 — ADMINISTRATION
Overview- Section 1.1 — GENERAL
- Section 1.11 — OFFICE OF THE STATE FIRE MARSHAL
- Section 101 — SCOPE AND GENERAL REQUIREMENTS
- Section 102 — APPLICABILITY
- Section 103 — CODE COMPLIANCE AGENCY
- Section 104 — DUTIES AND POWERS OF THE FIRE CODE OFFICIAL
- Section 105 — PERMITS
- Section 106 — CONSTRUCTION DOCUMENTS
- Section 107 — TEMPORARY STRUCTURES, USES, EQUIPMENT AND SYSTEMS
- Section 108 — FEES
- Section 109 — INSPECTIONS
- Section 110 — MAINTENANCE
- Section 111 — SERVICE UTILITIES
- Section 112 — MEANS OF APPEALS
- Section 113 — VIOLATIONS
- Section 114 — STOP WORK ORDER
- Section 115 — UNSAFE STRUCTURES OR EQUIPMENT
-
▸ Chapter 2 — DEFINITIONS
-
▸ Chapter 3 — GENERAL REQUIREMENTS
Overview- Section 301 — GENERAL
- Section 302 — DEFINITIONS
- Section 303 — ASPHALT KETTLES
- Section 304 — COMBUSTIBLE WASTE MATERIAL
- Section 305 — IGNITION SOURCES
- Section 306 — MOTION PICTURE PROJECTION ROOMS AND FILM
- Section 307 — OPEN BURNING, RECREATIONAL FIRES AND PORTABLE OUTDOOR FIREPLACES
- Section 308 — OPEN FLAMES
- Section 309 — POWERED INDUSTRIAL TRUCKS AND EQUIPMENT
- Section 310 — SMOKING
- Section 311 — VACANT PREMISES
- Section 312 — VEHICLE IMPACT PROTECTION
- Section 313 — FUELED EQUIPMENT
- Section 314 — INDOOR DISPLAYS
- Section 315 — GENERAL STORAGE
- Section 316 — HAZARDS TO FIREFIGHTERS
- Section 317 — VEGETATIVE AND LANDSCAPED ROOFS
- Section 318 — LAUNDRY CARTS
- Section 319 — ADDITIVE MANUFACTURING (3D PRINTING)
- Section 320 — BATTERY STORAGE
- Section 321 — ARTIFICIAL COMBUSTIBLE VEGETATION
- Section 322 — POWERED MICROMOBILITY DEVICES
- Section 323 — ROAD TUNNELS, BRIDGES AND OTHER LIMITED ACCESS HIGHWAYS [SFM]
-
▸ Chapter 4 — EMERGENCY PLANNING AND PREPAREDNESS
-
▸ Chapter 5 — FIRE SERVICE FEATURES
Overview- Section 501 — GENERAL
- Section 502 — DEFINITIONS
- Section 503 — FIRE APPARATUS ACCESS ROADS
- Section 504 — ACCESS TO BUILDING OPENINGS AND ROOFS
- Section 505 — PREMISES IDENTIFICATION
- Section 506 — KEY BOXES
- Section 507 — FIRE PROTECTION WATER SUPPLIES
- Section 508 — FIRE COMMAND CENTER
- Section 509 — FIRE PROTECTION AND UTILITY EQUIPMENT IDENTIFICATION AND ACCESS
- Section 510 — EMERGENCY RESPONDER COMMUNICATIONS ENHANCEMENT SYSTEMS
-
▸ Chapter 6 — BUILDING SERVICES AND SYSTEMS
Overview- Section 601 — GENERAL
- Section 602 — DEFINITIONS
- Section 603 — ELECTRICAL EQUIPMENT, WIRING AND HAZARDS
- Section 604 — ELEVATOR OPERATION, MAINTENANCE AND FIRE SERVICE KEYS
- Section 605 — FUEL-FIRED APPLIANCES
- Section 606 — COMMERCIAL COOKING EQUIPMENT AND SYSTEMS
- Section 607 — COMMERCIAL COOKING OIL STORAGE
- Section 608 — MECHANICAL REFRIGERATION
- Section 609 — HYPERBARIC FACILITIES
- Section 610 — CLOTHES DRYER EXHAUST SYSTEMS
-
▸ Chapter 7 — FIRE AND SMOKE PROTECTION FEATURES
Overview- Section 701 — GENERAL
- Section 702 — DEFINITIONS
- Section 703 — PENETRATIONS
- Section 704 — JOINTS AND VOIDS
- Section 705 — DOOR AND WINDOW OPENINGS
- Section 706 — DUCT AND AIR TRANSFER OPENINGS
- Section 707 — CONCEALED SPACES
- Section 708 — SPRAY FIRE-RESISTANT MATERIALS AND INTUMESCENT FIRE-RESISTANT MATERIALS
- Section 709 — EXTERIOR WALLS
-
▸ Chapter 8 — INTERIOR FINISH, DECORATIVE MATERIALS AND FURNISHINGS
Overview- Section 801 — GENERAL
- Section 802 — DEFINITIONS
- Section 803 — INTERIOR WALL AND CEILING FINISH IN EXISTING BUILDINGS
- Section 804 — INTERIOR WALL AND CEILING TRIM AND INTERIOR FLOOR FINISH IN NEW AND EXISTING BUI…
- Section 805 — UPHOLSTERED FURNITURE AND MATTRESSES IN NEW AND EXISTING BUILDINGS
- Section 806 — NATURAL DECORATIVE VEGETATION IN NEW AND EXISTING BUILDINGS
- Section 807 — DECORATIVE MATERIALS AND ARTIFICIAL DECORATIVE VEGETATION IN NEW AND EXISTING BU…
- Section 808 — FURNISHINGS OTHER THAN UPHOLSTERED FURNITURE AND
-
▸ Chapter 9 — FIRE PROTECTION AND LIFE SAFETY SYSTEMS
Overview- Section 901 — GENERAL
- Section 902 — DEFINITIONS
- Section 903 — AUTOMATIC SPRINKLER SYSTEMS
- Section 904 — ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS
- Section 905 — STANDPIPE SYSTEMS
- Section 906 — PORTABLE FIRE EXTINGUISHERS
- Section 907 — FIRE ALARM AND DETECTION SYSTEMS
- Section 908 — EMERGENCY ALARM SYSTEMS
- Section 909 — SMOKE CONTROL SYSTEMS
- Section 910 — SMOKE AND HEAT REMOVAL
- Section 911 — EXPLOSION CONTROL
- Section 912 — FIRE DEPARTMENT CONNECTIONS
- Section 913 — FIRE PUMPS
- Section 914 — FIRE PROTECTION BASED ON SPECIAL DETAILED REQUIREMENTS OF USE AND OCCUPANCY
- Section 915 — CARBON MONOXIDE (CO) DETECTION
- Section 916 — GAS DETECTION SYSTEMS
- Section 917 — MASS NOTIFICATION SYSTEMS
-
▸ Chapter 10 — MEANS OF EGRESS
Overview- Section 1001 — ADMINISTRATION
- Section 1002 — DEFINITIONS
- Section 1003 — GENERAL MEANS OF EGRESS
- Section 1004 — OCCUPANT LOAD
- Section 1005 — MEANS OF EGRESS SIZING
- Section 1006 — NUMBERS OF EXITS AND EXIT ACCESS DOORWAYS
- Section 1007 — EXIT AND EXIT ACCESS DOORWAY CONFIGURATION
- Section 1008 — MEANS OF EGRESS ILLUMINATION
- Section 1009 — ACCESSIBLE MEANS OF EGRESS
- Section 1010 — DOORS, GATES AND TURNSTILES
- Section 1011 — STAIRWAYS
- Section 1012 — RAMPS
- Section 1013 — EXIT SIGNS
- Section 1014 — HANDRAILS
- Section 1015 — GUARDS
- Section 1016 — EXIT ACCESS
- Section 1017 — EXIT ACCESS TRAVEL DISTANCE
- Section 1018 — AISLES
- Section 1019 — EXIT ACCESS STAIRWAYS AND RAMPS
- Section 1020 — CORRIDORS
- Section 1021 — EGRESS BALCONIES
- Section 1022 — EXITS
- Section 1023 — INTERIOR EXIT STAIRWAYS AND RAMPS
- Section 1024 — EXIT PASSAGEWAYS
- Section 1025 — LUMINOUS EGRESS PATH MARKINGS
- Section 1026 — HORIZONTAL EXITS
- Section 1027 — EXTERIOR EXIT STAIRWAYS AND RAMPS
- Section 1028 — EXIT DISCHARGE
- Section 1029 — EGRESS COURTS
- Section 1030 — ASSEMBLY
- Section 1031 — EMERGENCY ESCAPE AND RESCUE
- Section 1032 — MAINTENANCE OF THE MEANS OF EGRESS
-
▸ Chapter 11 — CONSTRUCTION REQUIREMENTS FOR EXISTING BUILDINGS
Overview- Section 1101 — GENERAL
- Section 1102 — DEFINITIONS
- Section 1103 — FIRE SAFETY REQUIREMENTS FOR EXISTING BUILDINGS
- Section 1104 — MEANS OF EGRESS FOR EXISTING BUILDINGS
- Section 1105 — CONSTRUCTION REQUIREMENTS FOR EXISTING GROUP I-2
- Section 1106 — REQUIREMENTS FOR OUTDOOR OPERATIONS
- Section 1107 — ENERGY STORAGE SYSTEMS
- Section 1108 — GROUP A PUBLIC ADDRESS SYSTEM
- Section 1113 — EXISTING GROUP R-1 AND GROUP R-2 OCCUPANCIES [SFM]
- Section 1114 — EXISTING HIGH-RISE BUILDINGS [SFM]
- Section 1115 — EXISTING GROUP I OCCUPANCIES [SFM]
- Section 1116 — EXISTING GROUP L AND GROUP H-8 OCCUPANCIES [SFM]
-
▸ Chapter 12 — ENERGY SYSTEMS
-
▸ Chapter 22 — COMBUSTIBLE DUST-PRODUCING OPERATIONS
-
▸ Chapter 23 — MOTOR FUEL-DISPENSING FACILITIES AND REPAIR GARAGES
Overview- Section 2301 — GENERAL
- Section 2302 — DEFINITIONS
- Section 2303 — LOCATION OF DISPENSING DEVICES
- Section 2304 — DISPENSING OPERATIONS
- Section 2305 — OPERATIONAL REQUIREMENTS
- Section 2306 — FLAMMABLE AND COMBUSTIBLE LIQUID MOTOR FUEL-DISPENSING FACILITIES
- Section 2307 — LIQUEFIED PETROLEUM GAS MOTOR FUEL-DISPENSING FACILITIES
- Section 2308 — COMPRESSED NATURAL GAS MOTOR FUEL-DISPENSING FACILITIES
- Section 2309 — HYDROGEN MOTOR FUEL-DISPENSING AND GENERATION FACILITIES
- Section 2310 — MARINE MOTOR FUEL-DISPENSING FACILITIES
- Section 2311 — REPAIR GARAGES
-
▸ Chapter 24 — FLAMMABLE FINISHES
Overview- Section 2401 — GENERAL
- Section 2402 — DEFINITIONS
- Section 2403 — PROTECTION OF OPERATIONS
- Section 2404 — SPRAY FINISHING
- Section 2405 — DIPPING OPERATIONS
- Section 2406 — POWDER COATING
- Section 2407 — ELECTROSTATIC APPARATUS
- Section 2408 — ORGANIC PEROXIDES AND DUAL-COMPONENT COATINGS
- Section 2409 — INDOOR MANUFACTURING OF REINFORCED PLASTICS
- Section 2410 — FLOOR SURFACING AND FINISHING OPERATIONS
-
▸ Chapter 26 — FUMIGATION AND INSECTICIDAL FOGGING
-
▸ Chapter 27 — SEMICONDUCTOR FABRICATION FACILITIES
-
▸ Chapter 28 — LUMBER YARDS AND AGRO-INDUSTRIAL, SOLID BIOMASS AND
Overview- Section 2801 — GENERAL
- Section 2802 — DEFINITIONS
- Section 2803 — GENERAL REQUIREMENTS
- Section 2804 — FIRE PROTECTION
- Section 2805 — PLYWOOD, VENEER AND COMPOSITE BOARD MILLS
- Section 2806 — LOG STORAGE AREAS
- Section 2807 — STORAGE OF WOOD CHIPS AND
- Section 2808 — STORAGE AND PROCESSING OF WOOD CHIPS, HOGGED MATERIALS, FINES, COMPOST, SOLID B…
- Section 2809 — EXTERIOR STORAGE OF FINISHED LUMBER AND SOLID BIOFUEL PRODUCTS
- Section 2810 — OUTDOOR STORAGE OF PALLETS AT PALLET MANUFACTURING AND RECYCLING FACILITIES
-
▸ Chapter 29 — MANUFACTURE OF ORGANIC COATINGS
Overview- Section 2901 — GENERAL
- Section 2902 — DEFINITION
- Section 2903 — GENERAL PRECAUTIONS
- Section 2904 — ELECTRICAL EQUIPMENT AND PROTECTION
- Section 2905 — PROCESS STRUCTURES
- Section 2906 — PROCESS MILLS AND KETTLES
- Section 2907 — PROCESS PIPING
- Section 2908 — RAW MATERIALS IN PROCESS AREAS
- Section 2909 — RAW MATERIALS AND FINISHED PRODUCTS
-
▸ Chapter 31 — TENTS, TEMPORARY SPECIAL EVENT STRUCTURES AND OTHER
Overview- Section 3101 — GENERAL
- Section 3102 — DEFINITIONS
- Section 3103 — TEMPORARY TENTS AND MEMBRANE STRUCTURES
- Section 3104 — TEMPORARY AND PERMANENT TENTS AND MEMBRANE STRUCTURES
- Section 3105 — TEMPORARY SPECIAL EVENT STRUCTURES
- Section 3106 — INFLATABLE AMUSEMENT DEVICES
- Section 3107 — OUTDOOR ASSEMBLY EVENTS
- Section 3108 — OPERATIONAL REQUIREMENTS
-
▸ Chapter 32 — HIGH-PILED COMBUSTIBLE STORAGE
Overview- Section 3201 — GENERAL
- Section 3202 — DEFINITIONS
- Section 3203 — COMMODITY CLASSIFICATION
- Section 3204 — DESIGNATION OF HIGH-PILED STORAGE AREAS
- Section 3205 — HOUSEKEEPING AND MAINTENANCE
- Section 3206 — GENERAL FIRE PROTECTION AND LIFE SAFETY FEATURES
- Section 3207 — SOLID-PILED AND SHELF STORAGE
- Section 3208 — RACK STORAGE
- Section 3209 — AUTOMATED STORAGE
- Section 3210 — SPECIALTY STORAGE
-
▸ Chapter 33 — FIRE SAFETY DURING CONSTRUCTION AND DEMOLITION
Overview- Section 3301 — GENERAL
- Section 3302 — DEFINITIONS
- Section 3303 — ADMINISTRATIVE SAFETY CONTROLS
- Section 3304 — PROTECTION OF COMBUSTIBLE MATERIALS
- Section 3305 — IGNITION SOURCE CONTROLS
- Section 3306 — FIRE PROTECTION SYSTEMS AND DEVICES
- Section 3307 — FIRE DEPARTMENT SITE ACCESS AND WATER SUPPLY
- Section 3308 — MOTORIZED CONSTRUCTION EQUIPMENT
- Section 3309 — HAZARDOUS MATERIALS
- Section 3310 — ADDITIONAL SAFEGUARDS FOR OCCUPIED BUILDINGS
- Section 3311 — ADDITIONAL SAFEGUARDS FOR TYPES I AND II CONSTRUCTION
- Section 3312 — ADDITIONAL SAFEGUARDS FOR TYPE IV CONSTRUCTION
-
▸ Chapter 34 — TIRE REBUILDING AND TIRE STORAGE
-
▸ Chapter 35 — WELDING AND OTHER HOT WORK
Overview- Section 3501 — GENERAL
- Section 3502 — DEFINITIONS
- Section 3503 — GENERAL REQUIREMENTS
- Section 3504 — FIRE SAFETY REQUIREMENTS
- Section 3505 — GAS WELDING AND CUTTING
- Section 3506 — ELECTRIC ARC HOT WORK
- Section 3507 — CALCIUM CARBIDE SYSTEMS
- Section 3508 — ACETYLENE GENERATORS
- Section 3509 — PIPING MANIFOLDS AND HOSE SYSTEMS FOR FUEL GASES AND OXYGEN
- Section 3510 — HOT WORK ON FLAMMABLE AND COMBUSTIBLE LIQUID STORAGE TANKS
-
▸ Chapter 37 — COMBUSTIBLE FIBERS
- Chapter 38 — RESERVED
-
▸ Chapter 39 — PROCESSING AND EXTRACTION FACILITIES
-
▸ Chapter 40 — STORAGE OF DISTILLED SPIRITS AND WINES
-
▸ Chapter 41 — TEMPORARY HEATING AND COOKING OPERATIONS
-
▸ Chapter 48 — MOTION PICTURE AND TELEVISION PRODUCTION STUDIO SOUND
Overview- Section 4801 — GENERAL
- Section 4802 — OCCUPANCY CLASSIFICATION
- Section 4803 — REQUIRED PERMITS
- Section 4804 — GENERAL REQUIREMENTS
- Section 4805 — FIRE-EXTINGUISHING SYSTEMS
- Section 4806 — FIRE DETECTION EQUIPMENT
- Section 4807 — FIRE SAFETY OFFICERS
- Section 4808 — ELECTRICAL REQUIREMENTS
- Section 4809 — MECHANICAL EQUIPMENT
- Section 4810 — DESIGN REQUIREMENTS
- Section 4811 — PRODUCTION LOCATIONS
- Chapter 49 — REQUIREMENTS FOR WILDLAND-URBAN INTERFACE FIRE AREAS
-
▸ Chapter 50 — HAZARDOUS MATERIALS—GENERAL PROVISIONS
- Chapter 52 — RESERVED
-
▸ Chapter 53 — COMPRESSED GASES
-
▸ Chapter 54 — CORROSIVE MATERIALS
-
▸ Chapter 55 — CRYOGENIC FLUIDS
-
▸ Chapter 56 — EXPLOSIVES AND FIREWORKS
Overview- Section 5601 — GENERAL
- Section 5602 — DEFINITIONS
- Section 5603 — RECORDKEEPING AND REPORTING
- Section 5604 — EXPLOSIVE MATERIALS STORAGE AND HANDLING
- Section 5605 — MANUFACTURE, ASSEMBLY AND TESTING OF EXPLOSIVES, EXPLOSIVE MATERIALS AND FIREWO…
- Section 5606 — SMALL ARMS AMMUNITION AND SMALL ARMS AMMUNITION COMPONENTS
- Section 5607 — BLASTING
- Section 5608 — FIREWORKS DISPLAY
- Section 5609 — TEMPORARY STORAGE OF CONSUMER FIREWORKS
- Section 5610 — EXPERIMENTAL ROCKETS/UNLIMITED
- Section 5611 — MODEL ROCKETS
- Section 5612 — EXPERIMENTAL HIGH POWER ROCKETS AND MOTORS
- Section 5613 — EMERGENCY SIGNALING DEVICES
-
▸ Chapter 57 — FLAMMABLE AND COMBUSTIBLE LIQUIDS
-
▸ Chapter 58 — FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS
Overview- Section 5801 — GENERAL
- Section 5802 — DEFINITIONS
- Section 5803 — GENERAL REQUIREMENTS
- Section 5804 — STORAGE
- Section 5805 — USE
- Section 5806 — FLAMMABLE CRYOGENIC FLUIDS
- Section 5807 — METAL HYDRIDE STORAGE SYSTEMS
- Section 5808 — HYDROGEN FUEL GAS ROOMS
- Section 5809 — ON-DEMAND HYDROGEN MOBILE FUELING OPERATIONS
-
▸ Chapter 60 — HIGHLY TOXIC AND TOXIC MATERIALS
-
▸ Chapter 61 — LIQUEFIED PETROLEUM GASES
Overview- Section 6101 — GENERAL
- Section 6102 — DEFINITIONS
- Section 6103 — INSTALLATION OF EQUIPMENT
- Section 6104 — LOCATION OF LP-GAS CONTAINERS
- Section 6105 — PROHIBITED USE OF LP-GAS
- Section 6106 — DISPENSING AND OVERFILLING
- Section 6107 — SAFETY PRECAUTIONS AND DEVICES
- Section 6108 — FIRE PROTECTION
- Section 6109 — STORAGE OF PORTABLE LP-GAS CONTAINERS AWAITING USE OR RESALE
- Section 6110 — LP-GAS CONTAINERS NOT IN SERVICE
- Section 6111 — PARKING AND GARAGING OF LP-GAS TANK VEHICLES
-
▸ Chapter 62 — ORGANIC PEROXIDES
-
▸ Chapter 63 — OXIDIZERS, OXIDIZING GASES AND OXIDIZING CRYOGENIC FLUIDS
-
▸ Chapter 64 — PYROPHORIC MATERIALS
-
▸ Chapter 65 — PYROXYLIN (CELLULOSE NITRATE) PLASTICS
-
▸ Chapter 66 — UNSTABLE (REACTIVE) MATERIALS
-
▸ Chapter 67 — WATER-REACTIVE SOLIDS AND LIQUIDS
-
▸ Chapter 80 — REFERENCED STANDARDS
Overview- Section 435 — SPECIAL PROVISIONS FOR LICENSED 24-HOUR CARE FACILITIES IN A GROUP R-2.1, R-3.1,…
- Section 436 — GROUP I-4 [SFM]
- Section 452 — SCHOOL FACILITIES FOR KINDERGARTEN THROUGH 12TH GRADE AND GROUP E CHILD-CARE
- Section 455 — LARGE FAMILY DAY-CARE HOMES [SFM]
- Section A101 — GENERAL
- Section B101 — GENERAL
- Section B102 — DEFINITIONS
- Section B103 — MODIFICATIONS
- Section B104 — FIRE-FLOW CALCULATION AREA
- Section B105 — FIRE-FLOW REQUIREMENTS FOR BUILDINGS
- Section B106 — REFERENCED STANDARDS
- Section BB101 — SCOPE
- Section BB102 — DEFINITIONS
- Section BB103 — MODIFICATIONS
- Section BB104 — FIRE AREA
- Section BB105 — FIRE-FLOW REQUIREMENTS FOR BUILDINGS
- Section C101 — GENERAL
- Section C102 — NUMBER OF FIRE HYDRANTS
- Section C103 — FIRE HYDRANT SPACING
- Section C104 — CONSIDERATION OF EXISTING FIRE HYDRANTS
- Section C105 — REFERENCED STANDARD
- Section CC101 — SCOPE
- Section CC102 — LOCATION
- Section CC103 — NUMBER OF FIRE HYDRANTS
- Section CC104 — CONSIDERATION OF EXISTING FIRE HYDRANTS
- Section CC105 — DISTRIBUTION OF FIRE HYDRANTS
- Section D101 — GENERAL
- Section D102 — REQUIRED ACCESS
- Section D103 — MINIMUM SPECIFICATIONS
- Section D104 — COMMERCIAL AND INDUSTRIAL DEVELOPMENTS
- Section D105 — AERIAL FIRE APPARATUS ACCESS ROADS
- Section D106 — MULTIPLE-FAMILY RESIDENTIAL DEVELOPMENTS
- Section D107 — ONE- OR TWO-FAMILY RESIDENTIAL DEVELOPMENTS
- Section D108 — REFERENCED STANDARDS
- Section E101 — GENERAL
- Section E102 — HAZARD CATEGORIES
- Section E103 — EVALUATION OF HAZARDS
- Section E104 — GHS HAZARDOUS MATERIALS DEFINITIONS
- Section E105 — REFERENCED STANDARDS
- Section F101 — GENERAL
- Section F102 — REFERENCED STANDARDS
- Section G101 — GENERAL
- Section H1 — SCOPE
- Section H2 — HAZARDOUS MATERIALS INVENTORY STATEMENTS (HMIS)
- Section H3 — HAZARDOUS MATERIALS MANAGEMENT PLAN (HMMP)
- Section H4 — MAINTENANCE OF RECORDS
- Section I101 — NONCOMPLIANT CONDITIONS
- Section I102 — REFERENCED STANDARDS
- Section J101 — GENERAL
- Section J102 — REFERENCED STANDARDS
- Section K101 — GENERAL
- Section K102 — FIRE SAFETY REQUIREMENTS FOR EXISTING AMBULATORY CARE FACILITIES
- Section K103 — INCIDENTAL USES IN EXISTING AMBULATORY CARE FACILITIES
- Section K104 — MEANS OF EGRESS REQUIREMENTS FOR EXISTING AMBULATORY CARE FACILITIES
- Section K105 — REFERENCED STANDARDS
- Section L101 — GENERAL
- Section L102 — DEFINITIONS
- Section L103 — PERMITS
- Section L104 — DESIGN AND INSTALLATION
- Section L105 — ACCEPTANCE TESTS
- Section L106 — INSPECTION, TESTING AND MAINTENANCE
- Section L107 — REFERENCED STANDARDS
- Section M101 — SCOPE
- Section M102 — WHERE REQUIRED
- Section M103 — COMPLIANCE
- Section N101 — GENERAL
- Section N102 — DEFINITIONS
- Section N103 — PUBLIC SAFETY FOR EVENTS
- Section N104 — INTERIOR FINISH AND DECORATIVE MATERIALS
- Section N105 — MULTIPLE-LEVEL BOOTHS
- Section N106 — COVERED BOOTHS
- Section N107 — DISPLAY AND STORAGE OF HAZARDOUS AND COMBUSTIBLE MATERIALS
- Section N108 — MEANS OF EGRESS
- Section N109 — REFERENCED STANDARDS
- Section O101 — SCOPE
- Section O102 — CONTAINERS
- Section O103 — CONTAINER LOCATION
- Section O104 — ADDITIONAL REQUIREMENTS
- Section O105 — REFERENCED STANDARDS
- Section P101 — GENERAL
- Section P102 — DEFINITIONS
- Section P103 — GENERAL REQUIREMENTS