Chapter 31 — TENTS, TEMPORARY SPECIAL EVENT STRUCTURES AND OTHER MEMBRANE STRUCTURES
3106 Inflatable Amusement Devices — 2025 California Fire Code
California Fire Code (Title 24, Part 9) · 2025 edition · updated 2026-09-25 · California
CBSC: official editions, supplements and errata
Italicized text is a California amendment to the model code, as printed in the official publication.
Cite as: 2025 California Fire Code (Title 24, Part 9) § 3106 · Effective January 1, 2026 · Official source: Building Standards Commission
3106.1 Scope.¶
Inflatable amusement devices shall comply with this section.
Exception: Inflatable amusement devices operated on private property where use is not open to the public.
3106.2 General.¶
Inflatable amusement devices shall be designed, anchored, operated and maintained in accordance with the manufacturer’s instructions and the requirements of ASTM F2374.
3106.3 Combustible materials.¶
The materials used in the construction of the inflatable amusement device shall meet the flame propagation criteria of Title 19, California Code of Regulations, Chapter 8. Additionally, a label and affidavit containing the information required in Sections 3104.3 and 3104.4 of this code shall be permanently affixed to the device.
For California, all fabrics and all interior decorative fabrics or materials shall be flame resistant in accordance with the provisions set forth in CCR, Title 19, Division 1, Chapter 8, and shall meet the requirements of this section. Tops and sidewalls shall be made either from fabric that has been flame-resistant treated with an approved exterior chemical process by an approved application concern, or from inherently flame-resistant fabric approved and listed by the State Fire Marshal (see CCR, Title 19, Division 1, Chapter 8).
31-8 2025 CALIFORNIA FIRE CODE
TENTS, TEMPORARY SPECIAL EVENT STRUCTURES AND OTHER MEMBRANE STRUCTURES
3106.4 Electrical equipment and wiring.¶
Electrical equipment, blower motors and temporary wiring for electrical power or lighting shall comply with Section 603.
3106.5 Portable generators.¶
Portable generators shall comply with the applicable provisions of the California Electrical Code and with the portable generator requirements of this code.
3106.6 Portable fire extinguishers.¶
Each generator shall be provided with an approved portable fire extinguisher complying with Section 906 that is placed in an approved location.