Chapter 34 — TIRE REBUILDING AND TIRE STORAGE

Section 3407 — FENCING

2025 California Fire Code (Title 24, Part 9) · 2025 edition · ingested 2026-07-07 · California

Full text via GoCodebook AI

We have the complete 2025 text of this code. Ask a question and get the exact controlling section with a citation.

Ask about this chapter

3407.1 Where required.

3407.1 Where required. Where the bulk volume of stored material is more than 20,000 cubic feet (566 m [3] ), a firmly anchored fence or other approved method of security that controls unauthorized access to the storage yard shall surround the storage yard.

3407.2 Construction.

3407.2 Construction. The fence shall be constructed of approved materials and shall be not less than 6 feet (1829 mm) high and provided with gates not less than 20 feet (6096 mm) wide.

3407.3 Locking.

3407.3 Locking. Gates to the storage yard shall be locked when the storage yard is not staffed.

3407.4 Unobstructed.

3407.4 Unobstructed. Gateways shall be kept clear of obstructions and be fully openable at all times. 34-4 2025 CALIFORNIA FIRE CODE on Jul 18, 2025 11:14 AM (CDT) THEREUNDER. TIRE REBUILDING AND TIRE STORAGE