Skip to content

Earlier editions: 20222019

Chapter 34 — TIRE REBUILDING AND TIRE STORAGE

3407 Fencing — 2025 California Fire Code

California Fire Code (Title 24, Part 9) · 2025 edition · updated 2026-09-25 · California

CBSC: official editions, supplements and errata

Italicized text is a California amendment to the model code, as printed in the official publication.

Cite as: 2025 California Fire Code (Title 24, Part 9) § 3407 · Effective January 1, 2026 · Official source: Building Standards Commission

3407.1 Where required.

Where the bulk volume of stored material is more than 20,000 cubic feet (566 m [3] ), a firmly anchored fence or other approved method of security that controls unauthorized access to the storage yard shall surround the storage yard.

Exceptions & meaning →

3407.2 Construction.

The fence shall be constructed of approved materials and shall be not less than 6 feet (1829 mm) high and provided with gates not less than 20 feet (6096 mm) wide.

Exceptions & meaning →

3407.3 Locking.

Gates to the storage yard shall be locked when the storage yard is not staffed.

Exceptions & meaning →

3407.4 Unobstructed.

Gateways shall be kept clear of obstructions and be fully openable at all times.

34-4 2025 CALIFORNIA FIRE CODE

TIRE REBUILDING AND TIRE STORAGE

Exceptions & meaning →