Chapter 48 — MOTION PICTURE AND TELEVISION PRODUCTION STUDIO SOUND
Section 4804 — GENERAL REQUIREMENTS
2025 California Fire Code (Title 24, Part 9) · 2025 edition · ingested 2026-07-07 · California
Full text via GoCodebook AI
We have the complete 2025 text of this code. Ask a question and get the exact controlling section with a citation.
4804.1 Housekeeping. ¶
4804.1 Housekeeping. Provisions of this part shall maintain proper housekeeping in accordance with Chapter 3.
4804.2 Aisles. ¶
4804.2 Aisles. Perimeter aisles within the sound stage and approved production facility shall be provided. Aisles required by this section shall have a minimum width of 4 feet (1219 mm). See Chapter 10 for maintenance requirements. Aisles required by this section shall have a minimum clear unobstructed height of 7 feet (2134 mm).
4804.3 Travel distance. ¶
4804.3 Travel distance. The maximum travel distance to any exit within the sound stage and approved production facility shall be 150 feet (45 720 mm).
4804.4 Exit doors. ¶
4804.4 Exit doors. Exit doors shall be equipped with panic hardware and swing in the direction of exit travel.
4804.5 Exit signs. ¶
4804.5 Exit signs. Illuminated exit signs shall be installed in accordance with the California Building Code. on Jul 18, 2025 11:14 AM (CDT) THEREUNDER. MOTION PICTURE AND TELEVISION PRODUCTION STUDIO SOUND STAGES, APPROVED PRODUCTION FACILITIES AND PRODUCTION LOCATIONS
4804.6 Exit illumination. ¶
4804.6 Exit illumination. Exit illumination shall be provided in accordance with the California Building Code. In the event of power fail- ure, exit path illumination shall be automatically provided by an approved emergency back-up system.
4804.7 Exit obstructions. ¶
4804.7 Exit obstructions. All means of egress shall be maintained in accordance with the provisions of Chapter 10, Section 1005.1.
4804.8 Foam plastics. ¶
4804.8 Foam plastics. All foam plastics shall meet the requirements of Chapter 8, Sections 807.5.1.5 and 807.5.7.
4804.9 Decorative materials. ¶
4804.9 Decorative materials. Drapes, drops, cut greens, etc., shall meet the flame retardant requirements of California Code of Regula- tions, Title 19, Division 1, Chapters 5 and 8, Sections 807.5.1.5 and 807.5.7.