Chapter 9 — INSTALLATION OF SPECIFIC APPLIANCES
917.4 Installation on Noncombustible Floors — 2025 California Mechanical Code
California Mechanical Code (Title 24, Part 4) · 2025 edition · updated 2026-09-25 · California
CBSC: official editions, supplements and errata
Italicized text is a California amendment to the model code, as printed in the official publication.
Cite as: 2025 California Mechanical Code (Title 24, Part 4) § 917.4 · Effective January 1, 2026 · Official source: Building Standards Commission
Floorinstalled food service appliances that are designed and marked “For use only in noncombustible locations” shall be installed on floors of noncombustible construction with noncombustible flooring and surface finish and with no combustible material against the underside thereof, or on noncombustible slabs or arches having no combustible material against the underside thereof. Such construction shall in all cases extend not less than 12 inches (305 mm) beyond the appliance on all sides. [NFPA 54:10.11.4.1, 10.11.4.2]
Get a plain-English answer with a citation back to this text.
Ask AI about this code