Chapter 9 — INSTALLATION OF SPECIFIC APPLIANCES
906.2 Installation — 2025 California Mechanical Code
California Mechanical Code (Title 24, Part 4) · 2025 edition · updated 2026-09-25 · California
CBSC: official editions, supplements and errata
Italicized text is a California amendment to the model code, as printed in the official publication.
Cite as: 2025 California Mechanical Code (Title 24, Part 4) § 906.2 · Effective January 1, 2026 · Official source: Building Standards Commission
The installation of floor furnaces shall comply with the following requirements:
(1) Listed floor furnaces shall be installed in accordance with their listing and the manufacturer’s installation instructions.
(2) Unlisted floor furnaces shall not be installed on combustible floors.
(3) Thermostats controlling floor furnaces shall not be located in a room or space that is capable of being separated from the room or space in which the register of the floor furnace is located. {NFPA 54:10.10.1}
Get a plain-English answer with a citation back to this text.