Section 11B-813 — ADULT CHANGING FACILITIES
2025 California Building Code (Title 24, Part 2) · 2025 edition · updated 2026-07-29 · California
Italicized text is a California amendment to the model code, as printed in the official publication.
11B-813 Adult changing facilities. Adult changing facilities shall comply with Section 11B-813.
11B-813.1 Location. Adult changing facilities shall be provided within a unisex (single-user or family) toilet room or other similar private
room.
11B-813.2 Features. Adult changing facilities shall provide features in compliance with Section 11B-813.2.
11B-813.2.1 Adult changing table. Adult changing tables shall be fixed to the floor or a wall and shall comply with Section 11B-813.2.1.
11B-813.2.1.1 Size. Adult changing tables shall have a changing surface of 70 inches (1778 mm) minimum length and 30 inches (762 mm) minimum width.
11B-813.2.1.2 Clearance. A 36 inches (914 mm) minimum width side clearance shall be provided along the entire length of one side of adult changing tables. At both ends of adult changing tables, clearance shall be provided measuring 36 inches (914 mm) minimum wide and a minimum length as long as the table width plus the width of the side clearance. End and side clearances shall be measured from the outermost extent of the table. Floor or ground surfaces of clearances shall comply with Section 11B- 302. Changes in level are not permitted.
11B-132 2025 CALIFORNIA BUILDING CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING
11B-813.2.1.3 Height and operation. Adult changing table height shall be adjustable from 17 inches (432 mm) above the floor or ground to 38 inches (965 mm) above the floor or ground, as measured to the top of the changing surface. Height adjustability shall be powered. Operable parts shall comply with Section 11B-309.
11B-813.2.1.4 Capacity. Adult changing tables shall provide a minimum weight capacity of 300 pounds (136 kg).
11B-813.2.1.5 Obstructions. When deployed, changing tables shall not obstruct the required width of an accessible route except as allowed by Section 11B-307.2.
11B-813.2.2 Water closet. No fewer than one water closet in compliance with Section 11B-604.
11B-813.2.3 Lavatory. One lavatory in compliance with Section 11B-606.
11B-813.2.4 Waste receptacle. No fewer than one waste receptacle in compliance with Section 11B-603.5.
11B-813.2.5 Coat hook. No fewer than one coat hook shall be provided in close proximity to the changing table and within one of the reach ranges specified in Section 11B-308.
11B-813.2.6 Shelf. No fewer than one shelf shall be provided in close proximity to the changing table at 40 inches (1016 mm) mini- mum and 48 inches (1219 mm) maximum above the finish floor.
11B-813.2.7 Accessories. Where provided, no fewer than one of each accessory shall comply with Section 11B-603.5.
11B-813.2.8 Turning space. Turning space complying with Section 11B-304 shall be provided within adult changing facilities.
11B-813.2.9 Overlap. Required clear floor spaces, clearance at fixtures and turning space shall be permitted to overlap.
11B-813.2.10 Door swing. A door, in any position, shall be permitted to encroach into the turning space by 12 inches (305 mm) maximum. Where a clear floor space complying with Section 11B-305.3 is provided within the room beyond the arc of the door swing, doors shall be permitted to swing into the clear floor space, clearance required for any fixture and clearance required for adult changing tables.
11B-813.2.11 Privacy latch. Each door to adult changing facilities shall have a privacy latch.
11B-813.2.12 Signs. A room identification sign complying with Section 11B-216 shall be provided at entrances to adult changing facilities. The text of the room identification sign shall be “ADULT CHANGING ROOM”.
An informational sign complying with Section 11B-216 shall be provided within adult changing facilities and in close proximity to the changing table. The informational sign shall indicate the maximum weight capacity of the adult changing table, as determined by the table manufacturer.
Where the commercial place of public amusement has a central directory, the central directory shall indicate the location of adult changing facilities. Where other directories indicate the location of toilet facilities, the other directories shall also indicate the loca- tion of adult changing facilities.
FIGURE 11B-813.2.1.2—CLEARANCE AROUND ADULT CHANGING TABLE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING
DIVISION 9: BUILT-IN ELEMENTS
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸ Contents — 2025 California Building Code (Title 24, Part 2)
- Chapter 1 — ADMINISTRATION
- Chapter 2 — DEFINITIONS
- Chapter 3 — OCCUPANCY CLASSIFICATION AND USE
- Chapter 4 — SPECIAL DETAILED REQUIREMENTS BASED ON OCCUPANCY A…
- Chapter 5 — GENERAL BUILDING HEIGHTS AND AREAS
- Chapter 6 — TYPES OF CONSTRUCTION
- Chapter 7 — FIRE AND SMOKE PROTECTION FEATURES
- Chapter 7A — MATERIALS AND CONSTRUCTION METHODS FOR EXTERIOR W…
- Chapter 8 — INTERIOR FINISHES
- Chapter 9 — FIRE PROTECTION AND LIFE SAFETY SYSTEMS
- Chapter 10 — MEANS OF EGRESS
- Chapter 11 — RESERVED
- Chapter 11A — HOUSING ACCESSIBILITY
-
▸ Chapter 11B — ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMM…
Overview- Section 11B-101 — PURPOSE
- Section 11B-104 — CONVENTIONS
- Section 11B-105 — REFERENCED STANDARDS
- Section 11B-106 — DEFINITIONS
- Section 11B-201 — APPLICATION
- Section 11B-202 — EXISTING BUILDINGS AND FACILITIES
- Section 11B-203 — GENERAL EXCEPTIONS
- Section 11B-204 — PROTRUDING OBJECTS
- Section 11B-205 — OPERABLE PARTS
- Section 11B-206 — ACCESSIBLE ROUTES
- Section 11B-207 — ACCESSIBLE MEANS OF EGRESS
- Section 11B-208 — PARKING SPACES
- Section 11B-209 — PASSENGER DROP-OFF AND LOADING ZONES AND BUS…
- Section 11B-210 — STAIRWAYS
- Section 11B-211 — DRINKING FOUNTAINS AND BOTTLE-FILLING STATIONS
- Section 11B-212 — KITCHENS, KITCHENETTES, WET BARS AND SINKS
- Section 11B-213 — TOILET FACILITIES AND BATHING FACILITIES
- Section 11B-214 — WASHING MACHINES AND CLOTHES DRYERS
- Section 11B-215 — FIRE ALARM SYSTEMS AND CARBON MONOXIDE ALARM…
- Section 11B-216 — SIGNS
- Section 11B-217 — TELEPHONES
- Section 11B-218 — TRANSPORTATION FACILITIES
- Section 11B-219 — ASSISTIVE LISTENING SYSTEMS
- Section 11B-220 — AUTOMATIC TELLER MACHINES, FARE MACHINES AND…
- Section 11B-221 — ASSEMBLY AREAS
- Section 11B-222 — DRESSING, FITTING AND LOCKER ROOMS
- Section 11B-223 — MEDICAL CARE AND LONG-TERM CARE FACILITIES
- Section 11B-224 — TRANSIENT LODGING GUEST ROOMS, HOUSING
- Section 11B-225 — STORAGE
- Section 11B-226 — DINING SURFACES AND WORK SURFACES
- Section 11B-227 — SALES AND SERVICE
- Section 11B-228 — DEPOSITORIES, VENDING MACHINES, CHANGE MACHI…
- Section 11B-229 — WINDOWS
- Section 11B-230 — TWO-WAY COMMUNICATION SYSTEMS
- Section 11B-231 — JUDICIAL FACILITIES
- Section 11B-232 — DETENTION FACILITIES AND CORRECTIONAL FACILI…
- Section 11B-233 — PUBLIC HOUSING FACILITIES
- Section 11B-234 — AMUSEMENT RIDES
- Section 11B-235 — RECREATIONAL BOATING FACILITIES
- Section 11B-236 — EXERCISE MACHINES AND EQUIPMENT
- Section 11B-237 — FISHING PIERS AND PLATFORMS
- Section 11B-238 — GOLF FACILITIES
- Section 11B-239 — MINIATURE GOLF FACILITIES
- Section 11B-240 — PLAY AREAS
- Section 11B-241 — SAUNAS AND STEAM ROOMS
- Section 11B-242 — SWIMMING POOLS, WADING POOLS AND SPAS
- Section 11B-243 — SHOOTING FACILITIES WITH FIRING POSITIONS
- Section 11B-244 — RELIGIOUS FACILITIES
- Section 11B-245 — PUBLIC ACCOMMODATIONS LOCATED IN PRIVATE RES…
- Section 11B-246 — OUTDOOR DEVELOPED AREAS
- Section 11B-247 — DETECTABLE WARNINGS AND DETECTABLE DIRECTION…
- Section 11B-248 — COMMON USE AREAS AND EMPLOYEE WORK AREAS
- Section 11B-249 — ADULT CHANGING FACILITIES
- Section 11B-250 — CIRCULATION PATHS
- Section 11B-301 — GENERAL
- Section 11B-302 — FLOOR OR GROUND SURFACES
- Section 11B-303 — CHANGES IN LEVEL
- Section 11B-304 — TURNING SPACE
- Section 11B-305 — CLEAR FLOOR OR GROUND SPACE
- Section 11B-306 — KNEE AND TOE CLEARANCE
- Section 11B-307 — PROTRUDING OBJECTS
- Section 11B-308 — REACH RANGES
- Section 11B-309 — OPERABLE PARTS
- Section 11B-401 — GENERAL
- Section 11B-402 — ACCESSIBLE ROUTES
- Section 11B-403 — W ALKING SURFACES
- Section 11B-404 — DOORS, DOORWAYS AND GATES
- Section 11B-405 — RAMPS
- Section 11B-406 — CURB RAMPS, BLENDED TRANSITIONS AND ISLANDS
- Section 11B-407 — ELEVATORS
- Section 11B-408 — LIMITED-USE/LIMITED-APPLICATION ELEVATORS
- Section 11B-409 — PRIVATE RESIDENCE ELEVATORS
- Section 11B-410 — PLATFORM LIFTS
- Section 11B-411 — DESTINATION-ORIENTED ELEVATORS
- Section 11B-501 — GENERAL
- Section 11B-502 — PARKING SPACES
- Section 11B-503 — PASSENGER DROP-OFF AND LOADING ZONES
- Section 11B-504 — STAIRWAYS
- Section 11B-505 — HANDRAILS
- Section 11B-601 — GENERAL
- Section 11B-602 — DRINKING FOUNTAINS AND BOTTLE-FILLING STATIONS
- Section 11B-603 — TOILET AND BATHING ROOMS
- Section 11B-604 — WATER CLOSETS AND TOILET COMPARTMENTS
- Section 11B-605 — URINALS
- Section 11B-606 — LAVATORIES AND SINKS
- Section 11B-607 — BATHTUBS
- Section 11B-608 — SHOWER COMPARTMENTS
- Section 11B-609 — GRAB BARS
- Section 11B-610 — SEATS
- Section 11B-611 — WASHING MACHINES AND CLOTHES DRYERS
- Section 11B-612 — SAUNAS AND STEAM ROOMS
- Section 11B-701 — GENERAL
- Section 11B-702 — FIRE ALARM SYSTEMS
- Section 11B-703 — SIGNS
- Section 11B-704 — TELEPHONES
- Section 11B-705 — DETECTABLE WARNINGS AND DETECTABLE DIRECTION…
- Section 11B-706 — ASSISTIVE LISTENING SYSTEMS
- Section 11B-707 — AUTOMATIC TELLER MACHINES, FARE MACHINES AND…
- Section 11B-708 — TWO-WAY COMMUNICATION SYSTEMS
- Section 11B-801 — GENERAL
- Section 11B-802 — WHEELCHAIR SPACES, COMPANION SEATS AND DESIG…
- Section 11B-803 — DRESSING, FITTING AND LOCKER ROOMS
- Section 11B-804 — KITCHENS, KITCHENETTES AND WET BARS
- Section 11B-805 — MEDICAL CARE AND LONG-TERM CARE FACILITIES
- Section 11B-806 — TRANSIENT LODGING GUEST ROOMS
- Section 11B-807 — HOLDING CELLS AND HOUSING CELLS
- Section 11B-808 — COURTROOMS
- Section 11B-809 — RESIDENTIAL DWELLING UNITS
- Section 11B-810 — TRANSPORTATION FACILITIES
- Section 11B-811 — STORAGE
- Section 11B-812 — ELECTRIC VEHICLE CHARGING STATIONS
- Section 11B-813 — ADULT CHANGING FACILITIES
- Section 11B-901 — GENERAL
- Section 11B-902 — DINING SURFACES AND WORK SURFACES
- Section 11B-903 — BENCHES
- Section 11B-904 — CHECK-OUT AISLES AND SALES AND SERVICE COUNT…
- Section 11B-1001 — GENERAL
- Section 11B-1002 — AMUSEMENT RIDES
- Section 11B-1003 — RECREATIONAL BOATING FACILITIES
- Section 11B-1004 — EXERCISE MACHINES AND EQUIPMENT
- Section 11B-1005 — FISHING PIERS AND PLATFORMS
- Section 11B-1006 — GOLF FACILITIES
- Section 11B-1007 — MINIATURE GOLF FACILITIES
- Section 11B-1008 — PLAY AREAS
- Section 11B-1009 — SWIMMING POOLS, WADING POOLS AND SPAS
- Section 11B-1010 — SHOOTING FACILITIES WITH FIRING POSITIONS
- Chapter 12 — INTERIOR ENVIRONMENT
- Chapter 13 — ENERGY EFFICIENCY
- Chapter 14 — EXTERIOR WALLS
- Chapter 15 — ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
- Chapter 16 — STRUCTURAL DESIGN
- Chapter 16A — STRUCTURAL DESIGN
- Chapter 17 — SPECIAL INSPECTIONS AND TESTS
- Chapter 17A — SPECIAL INSPECTIONS AND TESTS
- Chapter 18 — SOILS AND FOUNDATIONS
- Chapter 18A — SOILS AND FOUNDATIONS
- Chapter 19 — CONCRETE
- Chapter 19A — CONCRETE
- Chapter 20 — ALUMINUM
- Chapter 21 — MASONRY
- Chapter 21A — MASONRY
- Chapter 22 — STEEL
- Chapter 22A — STEEL
- Chapter 23 — WOOD
- Chapter 24 — GLASS AND GLAZING
- Chapter 25 — GYPSUM PANEL PRODUCTS AND PLASTER
- Chapter 26 — PLASTIC
- Chapter 27 — ELECTRICAL
- Chapter 28 — MECHANICAL SYSTEMS
- Chapter 29 — PLUMBING SYSTEMS
- Chapter 30 — ELEVATORS AND CONVEYING SYSTEMS
- Chapter 31 — SPECIAL CONSTRUCTION
- Chapter 31A — SYSTEMS FOR WINDOW CLEANING OR EXTERIOR BUILDING…
- Chapter 31B — PUBLIC POOLS
- Chapter 31C — RADIATION
- Chapter 31D — FOOD ESTABLISHMENTS
- Chapter 31F — MARINE OIL TERMINALS
- Chapter 32 — ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
- Chapter 33 — SAFEGUARDS DURING CONSTRUCTION
- Chapter 34 — RESERVED
- Chapter 35 — REFERENCED STANDARDS
- Appendix A — EMPLOYEE QUALIFICATIONS
- Appendix B — BOARD OF APPEALS
- Appendix C — GROUP U—AGRICULTURAL BUILDINGS
- Appendix D — FIRE DISTRICTS
- Appendix E — RESERVED
- Appendix F — RODENTPROOFING
- Appendix G — FLOOD-RESISTANT CONSTRUCTION
- Appendix H — SIGNS
- Appendix I — PATIO COVERS
- Appendix J — GRADING
- Appendix K — GROUP R-3 AND GROUP R-3.1 OCCUPANCIES PROTECTED B…
- Appendix L — EARTHQUAKE RECORDING INSTRUMENTATION
- Appendix M — TSUNAMI-GENERATED FLOOD HAZARDS
- Appendix N — REPLICABLE BUILDINGS
- Appendix O — PERFORMANCE-BASED APPLICATION
- Appendix P — SLEEPING LOFTS
- Appendix Q — EMERGENCY HOUSING