11B- 219.1 General. Assistive listening systems shall be provided in accordance with Section 11B- 219 and shall comply with Section 11B- 706 .

11B- 219.2 Required systems. An assistive listening system shall be provided in assembly areas, including conference and meeting

rooms.

Exception: This section does not apply to systems used exclusively for paging, background music, or a combination of these two

uses.

11B- 219.3 Receivers. The minimum number of receivers to be provided shall be equal to 4 percent of the total number of seats, but in no case less than two. Twenty-five percent minimum of receivers provided, but no fewer than two, shall be hearing-aid compatible in accordance with Section 11B- 706.3.

Exceptions:

  1. Where a building contains more than one assembly area and the assembly areas required to provide assistive listening systems are under one management, the total number of required receivers shall be permitted to be calculated according to the total number of seats in the assembly areas in the building provided that all receivers are usable with all systems.
  2. Where all seats in an assembly area are served by an induction loop assistive listening system, the minimum number of receivers required by Section 11B- 219.3 to be hearing-aid compatible shall not be required to be provided.

11B-219.4 Location. If the assistive-listening system provided is limited to specific areas or seats, then such areas or seats shall be within a 50-foot (15240 mm) viewing distance of the stage or playing area and shall have a complete view of the stage or playing

area.

11B-219.5 Permanent and portable systems. Permanently installed assistive-listening systems are required in areas if (1) they accom- modate at least 50 persons or if they have audio-amplification systems, and (2) they have fixed seating. If portable assistive-listening systems are used for conference or meeting rooms, the system may serve more than one room. An adequate number of electrical outlets or other supplementary wiring necessary to support a portable assistive-listening system shall be provided.