11B-803 Dressing, Fitting and Locker Rooms — 2025 California Building Code
California Building Code (Title 24, Part 2) · 2025 edition · updated 2026-09-25 · California
CBSC: official editions, supplements and errata
Italicized text is a California amendment to the model code, as printed in the official publication.
Cite as: 2025 California Building Code (Title 24, Part 2) § 11B-803 · Effective January 1, 2026 · Official source: Building Standards Commission
11B- 803.1 General. Dressing, fitting and locker rooms shall comply with Section 11B- 803 .
11B- 803.2 Turning space. Turning space complying with Section 11B- 304 shall be provided within the room.
11B- 803.3 Door swing. Doors shall not swing into the room unless a turning space complying with Section 11B- 304.3 is provided beyond the arc of the door swing.
11B- 803.4 Benches. A bench complying with Section 11B- 903 shall be provided within the room.
11B- 803.5 Coat hooks and shelves. Coat hooks provided within the room shall be located within one of the reach ranges specified in Section 11B- 308. Shelves shall be 40 inches ( 1016 mm) minimum and 48 inches ( 1219 mm) maximum above the finish floor or ground. Coat hooks shall not be located above the bench or other seating in the room.
11B-803.6 Mirrors. Mirrors shall be installed with the bottom edge of the reflecting surface 20 inches (508 mm) maximum above the finish floor or ground. Mirrors shall be full length with a reflective surface 18 inches (457 mm) wide minimum by 54 inches (1372 mm) high minimum and shall be mounted in a position affording a view to a person on the bench as well as to a person in a standing position.
Get a plain-English answer with a citation back to this text.