Skip to content

Chapter 11B — ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING

Section 11B-411 — DESTINATION-ORIENTED ELEVATORS

2025 California Building Code (Title 24, Part 2) · 2025 edition · updated 2026-07-29 · California

Italicized text is a California amendment to the model code, as printed in the official publication.

11B-411.1 General. Destination-oriented elevators shall comply with Section 11B-411 and with ASME A17.1. They shall be passenger elevators as classified by ASME A17.1. Elevator operation shall be automatic.

11B-411.1.1 Floor designations. In facilities served by destination-oriented elevator systems, floor designations shall be numeric char- acters only. Floor designations shall be “one” (1) or “zero” (0) at the main entry level and shall increase by one for each successive higher story or level. The initial floor below the main entry level shall be designated “minus one” (-1) and the designation for each successive lower story or level shall decrease by one. Stories or levels shall not be designated by alphabetic characters.

Exceptions:

1. In existing facilities where new elevators are installed or existing elevators are altered into a destination-oriented elevator system, levels within stories, such as mezzanines located above or below the main entry level shall be permit- ted to be designated with an alpha-numeric character such as “M2”, indicating “mezzanine” and the “story number”, respectively, in which it is located, provided there is no duplication with alpha-numeric designations of elevator cars in the facility.

2. Non-successive floor numbering shall be permitted where a specific floor number is omitted or where a floor is frequented only by service personnel for maintenance, repair or occasional monitoring of equipment.

11B-411.1.2 Car designations. Elevator cars shall be designated with a single alphabetic character. For elevators programmed to the same hall call console or group of hall call consoles, each elevator car shall be designated with a different single alphabetic character.

Exception: Elevator systems with more than 26 elevators shall be permitted to use alpha-numeric designations such as “A1”.

11B-411.2 Elevator landing requirements. Elevator landings shall comply with Section 11B-411.2.

11B-411.2.1 Hall call consoles. Hall call consoles shall comply with Sections 11B-411.2.1 and 11B-309.

11B-411.2.1.1 Location. Hall call consoles shall be wall-mounted. On floors with a building entry, including parking and trans- fer levels, each hoistway entrance shall be adjacent to a hall call console. On other floors, a minimum of one hoistway entrance shall be adjacent to a hall call console.

Exception: Hall call consoles beyond those required by Section 11B-411.2.1.1 shall be permitted to be provided outside the elevator landing and to be wall-mounted, pedestal-mounted or mounted on a kiosk or security turnstile.

11B-68 2025 CALIFORNIA BUILDING CODE

on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING

11B-411.2.1.2 Required features. Hall call consoles shall include a touch screen or keypad with display screen, an accessibility function button and audio output loudspeaker.

11B-411.2.1.2.1 Keypads. Keypads shall be in a 12-key ascending telephone keypad layout. Characters and symbols shall be centered on the corresponding button. The number five key shall have a single raised dot. The dot shall have a base diameter of 0.118 inch (3 mm) minimum and 0.120 inch (3.05 mm) maximum and a height of 0.025 inch (0.6 mm) minimum and 0.037 inch (0.9 mm) maximum. Keypads shall have a star () on the lower left button and a minus sign (-) on the lower right button. From any level above and below the main egress level, when the star button is pressed an elevator shall be dispatched to the main egress level.

11B-411.2.1.2.2 Touch screen. Touch screen display shall comply with Section 11B-411.2.1.2.4.

11B-411.2.1.2.3 Accessibility function button. The accessibility function button shall be identified by the International Symbol of Accessibility and a raised indication. The International Symbol of Accessibility shall comply with Section 11B- 703.7.2.1, and shall be [ 5] / 8 inch (15.9 mm) minimum in height. The indication shall be three raised dots. Each dot shall have a base diameter of 0.059 inch (1.5 mm) minimum and 0.063 inch (1.6 mm) maximum and a height of 0.025 inch (0.6 mm) mini- mum and 0.037 inch (0.9 mm) maximum. The dots shall be spaced [1] / 4 inch (6.4 mm), measured center to center, in the form of an equilateral triangle with a vertex pointing up. The accessibility function button shall not be provided with a key repeat function.

FIGURE 11B-411.2.1.2.3—DESTINATION-ORIENTED ELEVATOR ACCESSIBILITY FUNCTION BUTTON INDICATION

11B-411.2.1.2.4 Display screen. Upon activation of the accessibility function button, the display screen shall display infor- mation including but not limited to, operating instructions, user input confirmation, elevator assignment characters, direction to the assigned elevator and error messages. The display screen shall comply with Section 11B-411.2.1.2.4.

11B-411.2.1.2.4.1 Contrast. Display screens shall provide contrast with light characters and symbols on a dark back- ground or dark characters and symbols on a light background. The background shall be solid and static.

11B-411.2.1.2.4.2 Size. Elevator assignment characters shall be 1 inch high (25 mm) minimum.

11B-411.2.1.2.4.3 Duration. Elevator assignment characters shall be displayed for a minimum of 5 seconds.

11B-411.2.1.2.5 Audio output. Upon activation of the accessibility function button, the audio output shall provide verbal announcements, including but not limited to, operating instructions, user input confirmation, announcement of the eleva- tor assignment characters, direction to the assigned elevator and error messages. Audio output shall be recorded or digitized human speech, and shall be delivered through a loudspeaker. Auditory volume shall be at least 10 dB above ambi- ent sound level, but shall not exceed 80 dB, measured 36 inches (914 mm) in front of the console. At hall call console locations where the ambient sound level varies, auditory volume shall be maintained at the required volume by an auto- matic gain control or shall be set at not less than 75 dB.

11B-411.2.1.3 Arrangement. Hall call console arrangement of required features shall comply with Section 11B-411.2.1.3.

11B-411.2.1.3.1 Keypad call console arrangement. Where keypad call consoles are provided, the display screen shall be located directly above the keypad. The accessibility function button shall be located directly below the keypad at a height of 36 inches (914 mm) to 42 inches (1067 mm) above the finish floor.

11B-411.2.1.3.2 Touch screen call console arrangement. Where touch screen call consoles are provided, the touch screen shall be located directly above the accessibility function button. The accessibility function button shall be located at a height of 36 inches (914 mm) to 42 inches (1067 mm) above the finish floor.

11B-411.2.1.3.3 Proximity of required elements. Required features shall be provided on a hall call console assembly or as individual elements grouped in close proximity.

11B-411.2.1.3.4 Position. Display screens and touch screens shall be positioned so glare is reduced on the screen. Keypads or buttons shall slope away from the user at 15 to 25 degrees from the vertical plane. Touch screens shall be sloped away from the user at 7 to 25 degrees from the vertical plane.

11B-411.2.1.4 Additional features. Hall call console additional features, if provided, shall comply with Sections 11B-309 and 11B-411.2.1.4.

on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING

11B-411.2.1.4.1 Hall call console additional buttons. Hall call console buttons provided in addition to the accessibility function button and keypad buttons shall comply with Section 11B-411.2.1.4.1. Buttons in addition to the accessibility func- tion button are not permitted on hall call consoles using a touch screen.

11B-411.2.1.4.1.1 Arrangement. Buttons shall be arranged in columns to the right of the keypad with a minimum hori- zontal spacing of 1.5 times the horizontal spacing between the numeric keys and with the same vertical spacing as the numeric keys.

11B-411.2.1.4.1.2 Identification. Buttons shall be identified by raised characters and symbols, white on a black back- ground, complying with Section 11B-703.2 and Braille complying with Section 11B-703.3. Identification shall be placed immediately to the left of the control button to which the designation applies.

11B-411.2.1.4.2 Security or access controls. Security or access control system card readers associated with elevator oper- ation shall be in close proximity to each hall call console in a consistent manner throughout the facility.

11B-411.2.1.5 Button requirements. Keypad buttons, the accessibility function button and additional hall call console buttons shall comply with Section 11B-411.2.1.5.

11B-411.2.1.5.1 Size. Buttons shall have square shoulders, be [3] / 4 inch (19.1 mm) minimum in the smallest dimension and shall be raised [1] / 8 inch (3.2 mm) plus or minus [1] / 32 inch (0.8 mm) above the surrounding surface. The buttons shall be acti- vated by a mechanical motion that is detectable.

11B-411.2.1.5.2 Color. Characters and symbols on buttons, where provided, shall be white on a black background.

11B-411.2.1.6 Identification of floors served. In buildings with two or more elevator banks, each serving a different group of specific floors, hall call consoles located on floors with a building entry, including parking and transfer levels, shall be provided with signs complying with Sections 11B-703.2, 11B-703.3 and 11B-703.5 on the surface of or above the hall call console stating “FLOORS n1 – n2,” where n1 – n2 represents the range of floors served. Characters shall be white on a black background. When the accessi- bility function button is pressed, the audio output shall provide a verbal announcement of the floors served by the elevator group.

11B-411.2.1.7 Elevator car assignment. When the accessibility function button is pressed, elevator car assignment shall comply with Section 11B-411.2.1.7.

11B-411.2.1.7.1 Assignment by keypad hall call console. The audio output shall provide verbal instruction for the user to enter a destination floor. The selected destination floor shall be confirmed by verbal announcement and on the display screen. Verbal and visible indication of an invalid input shall be provided. The display screen shall indicate the elevator assignment characters and a verbal announcement shall be made of the assigned elevator responding to the call. Visual and verbal direction to the assigned elevator shall be provided.

elected destination floor shall be confirmed by verbal announcement and on the display_ screen. Verbal and visible indication of an invalid input shall be provided. The display screen shall indicate the elevator assignment characters and a verbal announcement shall be made of the assigned elevator responding to the call. Visual and verbal direction to the assigned elevator shall be provided.

11B-411.2.1.7.2 Assignment by touch screen hall call console. The audio output shall provide verbal instruction for the user to press the accessibility function button as a response to verbal direction in order to select the destination floor. The selected destination floor shall be confirmed by verbal announcement and on the display screen. Verbal and visible indica- tion of an invalid input shall be provided. The display screen shall indicate the elevator assignment characters and a verbal announcement shall be made of the assigned elevator responding to the call. Visual and verbal direction to the assigned elevator shall be provided.

Exception: In addition to assignment by Section 11B-411.2.1.7.2, a verbal announcement providing the user with an option to select an alternative mode of operation shall be permitted. Alternative operation shall be by one of the following options: 1. Virtual keypad. The size of the keypad shall be a nominal 4 inches (102 mm) wide by 5 inches (127 mm) high in a 12-key ascending telephone keypad layout centered in the console. Characters and symbols shall be centered on the corresponding button. Keypads shall have a star () on the lower left button and a minus sign (-) on the lower right button. Operation shall be by contact with the touch screen with a press on the key. The audio output shall provide user input confirmation after each key is pressed. Keys shall not be provided with a key repeat function. From any level above and below the main egress level, when the star button is pressed an elevator shall be dispatched to the main egress level. 2. Gesture-based mode of operation. Operation shall be by contact with the touch screen, without specific contact with an icon, and using established non-proprietary gestures for selection and input, including but not limited to tapping, sliding and tap-hold contact-release to select. The audio output shall provide verbal direction on use of the touch screen, and indication of floor selection options, until assignment to the elevator is given.

by contact with the touch screen, without specific contact_ with an icon, and using established non-proprietary gestures for selection and input, including but not limited to tapping, sliding and tap-hold contact-release to select. The audio output shall provide verbal direction on use of the touch screen, and indication of floor selection options, until assignment to the elevator is given.

11B-411.2.1.7.3 Assignment by security credential. If a security system or other form of access control system is provided, the audio output shall provide a verbal announcement and direction to the location of the access control activation sensor, such as “present security credential at the sensor immediately to the left”. Upon presentation of security credential, the destination floor shall be confirmed by verbal announcement and on the display screen. The display screen shall indicate the elevator assignment characters and a verbal announcement shall be made of the assigned elevator responding to the call. Visual and verbal direction to the assigned elevator shall be provided.

11B-411.2.1.7.4 Adjacency assignment. The system shall assign an elevator car immediately to the left or right of the hall call console.

Exception: The most adjacent elevator serving the selected floor shall be assigned by hall call consoles located outside the elevator landing.

11B-70 2025 CALIFORNIA BUILDING CODE

on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING

11B-411.2.2 Elevator car identification at elevator landings. Elevator car identification shall comply with Section 11B-411.2.2.

11B-411.2.2.1 Visible identification. Above or adjacent to each elevator car entrance there shall be a visible identification fixture with a car designation character. The identification fixture shall be 80 inches (2032 mm) minimum above the finish floor or ground to the bottom of the fixture. The characters on the fixture shall be upper case with a height of 4 inches (102 mm) mini- mum complying with Sections 11B-703.5.1, 11B-703.5.3, 11B-703.5.4, 11B-703.5.7 and 11B-703.5.8.

Exception: Existing buildings shall be permitted to have a visible identification fixture with a car designation character adjacent to each elevator car entrance centered at 72 inches (1829 mm) above the finish floor or ground. The character on the fixture shall be upper case with a height of 2 [1] / 2 inches (64 mm) minimum complying with Sections 11B-703.5.1, 11B- 703.5.3, 11B-703.5.4, 11B-703.5.7 and 11B-703.5.8.

all be permitted to have a visible identification fixture with a car designation character_ adjacent to each elevator car entrance centered at 72 inches (1829 mm) above the finish floor or ground. The character on the fixture shall be upper case with a height of 2 [1] / 2 inches (64 mm) minimum complying with Sections 11B-703.5.1, 11B- 703.5.3, 11B-703.5.4, 11B-703.5.7 and 11B-703.5.8.

11B-411.2.2.2 Verbal identification. When the accessibility function button is pressed, verbal announcement of the car desig- nation shall be provided at the elevator car entrance upon arrival. Audio output shall be recorded or digitized human speech, and shall be delivered through a loudspeaker. The verbal annunciator shall have a frequency of 300 Hz minimum and 3000 Hz maximum. Auditory volume shall be at least 10 dB above ambient sound level, but shall not exceed 80 dB, measured 36 inches (914 mm) in front of the elevator entrance and at 48 inches (1219 mm) above the floor. At elevator entrances where the ambient sound level varies, auditory volume shall be maintained at the required volume by an automatic gain control or shall be set at not less than 75 dB.

11B-411.2.3 Signs on jambs of elevator hoistway entrances. Signs on jambs of elevator hoistway entrances shall comply with Section 11B-411.2.3.

11B-411.2.3.1 Floor designation signs. Floor designation signs complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of elevator hoistway entrances. Signs shall be provided in both raised characters and Braille. Raised characters shall be 2 inches (51 mm) high. A raised star placed to the left of the floor designation, shall be provided on both jambs at the main entry level. The outside diameter of the star shall be 2 inches (51 mm) and all points shall be of equal length. Raised characters, including the star, shall be white on a black background. Braille complying with Section 11B-703.3 shall be placed below the corresponding raised characters and the star. The Braille translation for the star shall be “MAIN”. Applied plates are acceptable if they are permanently fixed to the jamb.

11B-411.2.3.2 Car designation signs. Car designation signs complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of the hoistway immediately below the floor designation. Signs shall be provided in both raised charac- ters and Braille. Raised characters shall be 2 inches (51 mm) high. Raised characters shall be white on a black background. Braille complying with Section 11B-703.3 shall be placed below the corresponding raised characters. Applied plates are accept- able if they are permanently fixed to the jamb.

FIGURE 11B -411.2.3—FLOOR DESIGNATION AND CAR DESIGNATION SIGNS ON JAMBS OF

DESTINATION-ORIENTED ELEVATOR HOISTWAY ENTRANCES

11B-411.3 Elevator door requirements. Hoistway and car doors shall comply with Section 11B-411.3.

11B-411.3.1 Type. Elevator door type shall comply with Section 11B-407.3.1.

11B-411.3.2 Operation. Elevator hoistway and car doors shall open and close automatically.

11B-411.3.3 Reopening device. Elevator doors shall be provided with a reopening device complying with Section 11B-411.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed by an object or person.

11B-411.3.3.1 Height. The height of the reopening device shall comply with Section 11B-407.3.3.1.

11B-411.3.3.2 Contact. The device contact shall comply with Section 11B-407.3.3.2.

11B-411.3.3.3 Duration. The door reopening device duration shall comply with Section 11B-407.3.3.3.

11B-411.3.4 Door delay. Door delay shall comply with Section 11B-407.3.5.

11B-411.3.5 Width. The width of elevator doors shall comply with Table 11B-407.4.1.

on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING

11B-411.4 Elevator car requirements. Elevator cars shall comply with Section 11B-411.4.

11B-411.4.1 Car dimensions. Inside dimensions of elevator cars and clear width of elevator doors shall comply with Section 11B- 407.4.1.

11B-411.4.2 Floor surfaces. Floor surfaces in elevator cars shall comply with Section 11B-407.4.2.

11B-411.4.3 Platform to hoistway clearance. Platform to hoistway clearance shall comply with Section 11B-407.4.3.

11B-411.4.4 Leveling. Elevator car leveling shall comply with Section 11B-407.4.4.

11B-411.4.5 Illumination. The level of illumination at the car controls shall comply with Section 11B-407.4.5.

11B-411.4.6 Elevator car controls. Where provided, elevator car controls shall comply with Sections 11B-411.4.6 and 11B-309.4.

11B-411.4.6.1 Location. Controls shall be located within one of the reach ranges specified in Section 11B-308.

11B-411.4.6.2 Buttons. Car control buttons shall comply with Sections 11B-407.4.6.2.1 and 11B-407.4.6.2.4. The car shall not have non-functional, exposed floor buttons.

11B-411.4.6.3 Emergency controls. Emergency controls shall comply with Section 11B-407.4.6.4.

11B-411.4.7 Designations and indicators of car control buttons. Designations and indicators of car control buttons shall comply with Section 11B-411.4.7.

11B-411.4.7.1 Type. Control button type shall comply with Section 11B-407.4.7.1.1.

11B-411.4.7.2 Location. Raised characters or symbols and Braille designations shall comply with Section 11B-407.4.7.1.2.

11B-411.4.7.3 Symbols. The control button for the emergency stop, alarm, door open, door close and phone shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3.

11B-411.4.7.4 Button spacing. Button spacing shall comply with Section 11B-407.4.7.1.5.

11B-411.4.8 Car position indicators. Audible and visible car position indicators shall be provided in elevator cars.

11B-411.4.8.1 Visible indicators. Visible indicators shall comply with Section 11B-411.4.8.1.

11B-411.4.8.1.1 Size. Characters shall comply with Section 11B-407.4.8.1.1.

11B-411.4.8.1.2 Location. Location of indicators shall comply with Section 11B-407.4.8.1.2.

11B-411.4.8.2 Audible indicators. Audible indicators shall comply with Section 11B-411.4.8.2.

11B-411.4.8.2.1 Signal type. The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop.

11B-411.4.8.2.2 Signal level. The verbal annunciator signal level shall comply with Section 11B-407.4.8.2.2.

11B-411.4.8.2.3 Frequency. The verbal annunciator frequency shall comply with Section 11B-407.4.8.2.3.

11B-411.4.9 Emergency communication. Emergency communication shall comply with Section 11B-407.4.9.

11B-411.4.10 Support rail. Support rails complying with Section 11B-407.4.10 shall be provided on at least one wall of the car.

11B-411.4.11 Floor destination indicators. There shall be on each elevator car door jamb a visual display indicating floor destinations.

11B-411.4.11.1 Height. Floor destination characters shall be 1 inch (25 mm) high minimum complying with Section 11B-703.5.3.

11B-411.4.11.2 Contrast. Visual display shall provide contrast with light characters on a dark background or dark characters on a light background. The background shall be solid and static.

11B-411.4.11.3 Duration. Floor destination characters shall be displayed upon elevator car arrival at the input floor and shall not extinguish until the elevator car arrives at the destination floor.

11B-72 2025 CALIFORNIA BUILDING CODE

on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING

DIVISION 5: GENERAL SITE AND BUILDING ELEMENTS

Get a plain-English answer with a citation back to this text.

Ask AI about this code
Contents — 2025 California Building Code (Title 24, Part 2)
2025 California Building Code (Title 24, Part 2)
  1. Chapter 1 — ADMINISTRATION
  2. Chapter 2 — DEFINITIONS
  3. Chapter 3 — OCCUPANCY CLASSIFICATION AND USE
  4. Chapter 4 — SPECIAL DETAILED REQUIREMENTS BASED ON OCCUPANCY A…
  5. Chapter 5 — GENERAL BUILDING HEIGHTS AND AREAS
  6. Chapter 6 — TYPES OF CONSTRUCTION
  7. Chapter 7 — FIRE AND SMOKE PROTECTION FEATURES
  8. Chapter 7A — MATERIALS AND CONSTRUCTION METHODS FOR EXTERIOR W…
  9. Chapter 8 — INTERIOR FINISHES
  10. Chapter 9 — FIRE PROTECTION AND LIFE SAFETY SYSTEMS
  11. Chapter 10 — MEANS OF EGRESS
  12. Chapter 11 — RESERVED
  13. Chapter 11A — HOUSING ACCESSIBILITY
  14. Chapter 11B — ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMM…
    Overview
    1. Section 11B-101 — PURPOSE
    2. Section 11B-104 — CONVENTIONS
    3. Section 11B-105 — REFERENCED STANDARDS
    4. Section 11B-106 — DEFINITIONS
    5. Section 11B-201 — APPLICATION
    6. Section 11B-202 — EXISTING BUILDINGS AND FACILITIES
    7. Section 11B-203 — GENERAL EXCEPTIONS
    8. Section 11B-204 — PROTRUDING OBJECTS
    9. Section 11B-205 — OPERABLE PARTS
    10. Section 11B-206 — ACCESSIBLE ROUTES
    11. Section 11B-207 — ACCESSIBLE MEANS OF EGRESS
    12. Section 11B-208 — PARKING SPACES
    13. Section 11B-209 — PASSENGER DROP-OFF AND LOADING ZONES AND BUS…
    14. Section 11B-210 — STAIRWAYS
    15. Section 11B-211 — DRINKING FOUNTAINS AND BOTTLE-FILLING STATIONS
    16. Section 11B-212 — KITCHENS, KITCHENETTES, WET BARS AND SINKS
    17. Section 11B-213 — TOILET FACILITIES AND BATHING FACILITIES
    18. Section 11B-214 — WASHING MACHINES AND CLOTHES DRYERS
    19. Section 11B-215 — FIRE ALARM SYSTEMS AND CARBON MONOXIDE ALARM…
    20. Section 11B-216 — SIGNS
    21. Section 11B-217 — TELEPHONES
    22. Section 11B-218 — TRANSPORTATION FACILITIES
    23. Section 11B-219 — ASSISTIVE LISTENING SYSTEMS
    24. Section 11B-220 — AUTOMATIC TELLER MACHINES, FARE MACHINES AND…
    25. Section 11B-221 — ASSEMBLY AREAS
    26. Section 11B-222 — DRESSING, FITTING AND LOCKER ROOMS
    27. Section 11B-223 — MEDICAL CARE AND LONG-TERM CARE FACILITIES
    28. Section 11B-224 — TRANSIENT LODGING GUEST ROOMS, HOUSING
    29. Section 11B-225 — STORAGE
    30. Section 11B-226 — DINING SURFACES AND WORK SURFACES
    31. Section 11B-227 — SALES AND SERVICE
    32. Section 11B-228 — DEPOSITORIES, VENDING MACHINES, CHANGE MACHI…
    33. Section 11B-229 — WINDOWS
    34. Section 11B-230 — TWO-WAY COMMUNICATION SYSTEMS
    35. Section 11B-231 — JUDICIAL FACILITIES
    36. Section 11B-232 — DETENTION FACILITIES AND CORRECTIONAL FACILI…
    37. Section 11B-233 — PUBLIC HOUSING FACILITIES
    38. Section 11B-234 — AMUSEMENT RIDES
    39. Section 11B-235 — RECREATIONAL BOATING FACILITIES
    40. Section 11B-236 — EXERCISE MACHINES AND EQUIPMENT
    41. Section 11B-237 — FISHING PIERS AND PLATFORMS
    42. Section 11B-238 — GOLF FACILITIES
    43. Section 11B-239 — MINIATURE GOLF FACILITIES
    44. Section 11B-240 — PLAY AREAS
    45. Section 11B-241 — SAUNAS AND STEAM ROOMS
    46. Section 11B-242 — SWIMMING POOLS, WADING POOLS AND SPAS
    47. Section 11B-243 — SHOOTING FACILITIES WITH FIRING POSITIONS
    48. Section 11B-244 — RELIGIOUS FACILITIES
    49. Section 11B-245 — PUBLIC ACCOMMODATIONS LOCATED IN PRIVATE RES…
    50. Section 11B-246 — OUTDOOR DEVELOPED AREAS
    51. Section 11B-247 — DETECTABLE WARNINGS AND DETECTABLE DIRECTION…
    52. Section 11B-248 — COMMON USE AREAS AND EMPLOYEE WORK AREAS
    53. Section 11B-249 — ADULT CHANGING FACILITIES
    54. Section 11B-250 — CIRCULATION PATHS
    55. Section 11B-301 — GENERAL
    56. Section 11B-302 — FLOOR OR GROUND SURFACES
    57. Section 11B-303 — CHANGES IN LEVEL
    58. Section 11B-304 — TURNING SPACE
    59. Section 11B-305 — CLEAR FLOOR OR GROUND SPACE
    60. Section 11B-306 — KNEE AND TOE CLEARANCE
    61. Section 11B-307 — PROTRUDING OBJECTS
    62. Section 11B-308 — REACH RANGES
    63. Section 11B-309 — OPERABLE PARTS
    64. Section 11B-401 — GENERAL
    65. Section 11B-402 — ACCESSIBLE ROUTES
    66. Section 11B-403 — W ALKING SURFACES
    67. Section 11B-404 — DOORS, DOORWAYS AND GATES
    68. Section 11B-405 — RAMPS
    69. Section 11B-406 — CURB RAMPS, BLENDED TRANSITIONS AND ISLANDS
    70. Section 11B-407 — ELEVATORS
    71. Section 11B-408 — LIMITED-USE/LIMITED-APPLICATION ELEVATORS
    72. Section 11B-409 — PRIVATE RESIDENCE ELEVATORS
    73. Section 11B-410 — PLATFORM LIFTS
    74. Section 11B-411 — DESTINATION-ORIENTED ELEVATORS
    75. Section 11B-501 — GENERAL
    76. Section 11B-502 — PARKING SPACES
    77. Section 11B-503 — PASSENGER DROP-OFF AND LOADING ZONES
    78. Section 11B-504 — STAIRWAYS
    79. Section 11B-505 — HANDRAILS
    80. Section 11B-601 — GENERAL
    81. Section 11B-602 — DRINKING FOUNTAINS AND BOTTLE-FILLING STATIONS
    82. Section 11B-603 — TOILET AND BATHING ROOMS
    83. Section 11B-604 — WATER CLOSETS AND TOILET COMPARTMENTS
    84. Section 11B-605 — URINALS
    85. Section 11B-606 — LAVATORIES AND SINKS
    86. Section 11B-607 — BATHTUBS
    87. Section 11B-608 — SHOWER COMPARTMENTS
    88. Section 11B-609 — GRAB BARS
    89. Section 11B-610 — SEATS
    90. Section 11B-611 — WASHING MACHINES AND CLOTHES DRYERS
    91. Section 11B-612 — SAUNAS AND STEAM ROOMS
    92. Section 11B-701 — GENERAL
    93. Section 11B-702 — FIRE ALARM SYSTEMS
    94. Section 11B-703 — SIGNS
    95. Section 11B-704 — TELEPHONES
    96. Section 11B-705 — DETECTABLE WARNINGS AND DETECTABLE DIRECTION…
    97. Section 11B-706 — ASSISTIVE LISTENING SYSTEMS
    98. Section 11B-707 — AUTOMATIC TELLER MACHINES, FARE MACHINES AND…
    99. Section 11B-708 — TWO-WAY COMMUNICATION SYSTEMS
    100. Section 11B-801 — GENERAL
    101. Section 11B-802 — WHEELCHAIR SPACES, COMPANION SEATS AND DESIG…
    102. Section 11B-803 — DRESSING, FITTING AND LOCKER ROOMS
    103. Section 11B-804 — KITCHENS, KITCHENETTES AND WET BARS
    104. Section 11B-805 — MEDICAL CARE AND LONG-TERM CARE FACILITIES
    105. Section 11B-806 — TRANSIENT LODGING GUEST ROOMS
    106. Section 11B-807 — HOLDING CELLS AND HOUSING CELLS
    107. Section 11B-808 — COURTROOMS
    108. Section 11B-809 — RESIDENTIAL DWELLING UNITS
    109. Section 11B-810 — TRANSPORTATION FACILITIES
    110. Section 11B-811 — STORAGE
    111. Section 11B-812 — ELECTRIC VEHICLE CHARGING STATIONS
    112. Section 11B-813 — ADULT CHANGING FACILITIES
    113. Section 11B-901 — GENERAL
    114. Section 11B-902 — DINING SURFACES AND WORK SURFACES
    115. Section 11B-903 — BENCHES
    116. Section 11B-904 — CHECK-OUT AISLES AND SALES AND SERVICE COUNT…
    117. Section 11B-1001 — GENERAL
    118. Section 11B-1002 — AMUSEMENT RIDES
    119. Section 11B-1003 — RECREATIONAL BOATING FACILITIES
    120. Section 11B-1004 — EXERCISE MACHINES AND EQUIPMENT
    121. Section 11B-1005 — FISHING PIERS AND PLATFORMS
    122. Section 11B-1006 — GOLF FACILITIES
    123. Section 11B-1007 — MINIATURE GOLF FACILITIES
    124. Section 11B-1008 — PLAY AREAS
    125. Section 11B-1009 — SWIMMING POOLS, WADING POOLS AND SPAS
    126. Section 11B-1010 — SHOOTING FACILITIES WITH FIRING POSITIONS
  15. Chapter 12 — INTERIOR ENVIRONMENT
  16. Chapter 13 — ENERGY EFFICIENCY
  17. Chapter 14 — EXTERIOR WALLS
  18. Chapter 15 — ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
  19. Chapter 16 — STRUCTURAL DESIGN
  20. Chapter 16A — STRUCTURAL DESIGN
  21. Chapter 17 — SPECIAL INSPECTIONS AND TESTS
  22. Chapter 17A — SPECIAL INSPECTIONS AND TESTS
  23. Chapter 18 — SOILS AND FOUNDATIONS
  24. Chapter 18A — SOILS AND FOUNDATIONS
  25. Chapter 19 — CONCRETE
  26. Chapter 19A — CONCRETE
  27. Chapter 20 — ALUMINUM
  28. Chapter 21 — MASONRY
  29. Chapter 21A — MASONRY
  30. Chapter 22 — STEEL
  31. Chapter 22A — STEEL
  32. Chapter 23 — WOOD
  33. Chapter 24 — GLASS AND GLAZING
  34. Chapter 25 — GYPSUM PANEL PRODUCTS AND PLASTER
  35. Chapter 26 — PLASTIC
  36. Chapter 27 — ELECTRICAL
  37. Chapter 28 — MECHANICAL SYSTEMS
  38. Chapter 29 — PLUMBING SYSTEMS
  39. Chapter 30 — ELEVATORS AND CONVEYING SYSTEMS
  40. Chapter 31 — SPECIAL CONSTRUCTION
  41. Chapter 31A — SYSTEMS FOR WINDOW CLEANING OR EXTERIOR BUILDING…
  42. Chapter 31B — PUBLIC POOLS
  43. Chapter 31C — RADIATION
  44. Chapter 31D — FOOD ESTABLISHMENTS
  45. Chapter 31F — MARINE OIL TERMINALS
  46. Chapter 32 — ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
  47. Chapter 33 — SAFEGUARDS DURING CONSTRUCTION
  48. Chapter 34 — RESERVED
  49. Chapter 35 — REFERENCED STANDARDS
  50. Appendix A — EMPLOYEE QUALIFICATIONS
  51. Appendix B — BOARD OF APPEALS
  52. Appendix C — GROUP U—AGRICULTURAL BUILDINGS
  53. Appendix D — FIRE DISTRICTS
  54. Appendix E — RESERVED
  55. Appendix F — RODENTPROOFING
  56. Appendix G — FLOOD-RESISTANT CONSTRUCTION
  57. Appendix H — SIGNS
  58. Appendix I — PATIO COVERS
  59. Appendix J — GRADING
  60. Appendix K — GROUP R-3 AND GROUP R-3.1 OCCUPANCIES PROTECTED B…
  61. Appendix L — EARTHQUAKE RECORDING INSTRUMENTATION
  62. Appendix M — TSUNAMI-GENERATED FLOOD HAZARDS
  63. Appendix N — REPLICABLE BUILDINGS
  64. Appendix O — PERFORMANCE-BASED APPLICATION
  65. Appendix P — SLEEPING LOFTS
  66. Appendix Q — EMERGENCY HOUSING

GoCodebook provides public access, search, citation, multilingual explanation, and practical interpretation of legally adopted building regulations. It is not a substitute for the official ICC or California code publications.