Section 11B-809 — RESIDENTIAL DWELLING UNITS

2025 California Building Code (Title 24, Part 2) · 2025 edition · updated 2026-07-29 · California

Italicized text is a California amendment to the model code, as printed in the official publication.

11B- 809.1 General. When located within public housing facilities, residential dwelling units shall comply with Section 11B- 809 . Residential dwelling units required to provide mobility features shall comply with Sections 11B-809.1.1 through 11B-809.1.3, and Sections 11B- 809.2 through 11B- 809.4. Residential dwelling units required to provide communication features shall comply with Section 11B- 809.5. Residential dwelling units with adaptable features shall comply with Section 11B-809.6.

11B-809.1.1 Door signal devices. In buildings with three or more residential dwelling units, the primary entry door to the dwelling unit shall be provided with a door buzzer, bell, chime or equivalent. The activating mechanism shall comply with Section 11B-309 and shall be connected to permanent wiring.

11B-809.1.2 Viewing devices. Where primary entry doors to residential dwelling units are provided with a viewing device for a stand- ing person, the primary entry door to a residential dwelling unit with mobility features shall also provide a lower viewing device 42 inches (1067 mm) minimum and 43 inches (1092 mm) maximum above the finish floor or ground, measured to the top of the device. The viewing device shall allow for a minimum 180 degree range of view.

11B-809.1.3 Washing machines and clothes dryers. Where washing machines and clothes dryers are provided in residential dwell- ing units with mobility features, they shall comply with Section 11B-611. Washing machines and clothes dryers shall be front loading and shall be the same or equivalent type as provided in comparable dwelling units not required to provide mobility features.

11B- 809.2 Accessible routes. Accessible routes complying with Division 4 shall be provided within residential dwelling units in accordance with Section 11B-809.2.

Exception: Accessible routes shall not be required to or within unfinished attics or unfinished basements.

11B- 809.2.1 Location. At least one accessible route shall connect all spaces and elements which are a part of the residential dwelling unit. Where only one accessible route is provided, it shall not pass through bathrooms, closets or similar spaces.

11B- 809.2.2 Turning space. All rooms served by an accessible route shall provide a turning space complying with Section 11B- 304 .

Exception: Turning space shall not be required in exterior spaces 30 inches ( 762 mm) maximum in depth or width.

11B- 809.3 Kitchen. Where a kitchen is provided, it shall comply with Section 11B- 804 .

11B- 809.4 Toilet facilities and bathing facilities. At least one bathroom shall comply with Section 11B- 603. No fewer than one of each type of fixture provided within the bathroom shall comply with applicable requirements of Sections 11B- 603 through 11B- 610 . Toilet and bathing fixtures required to comply with Sections 11B- 603 through 11B- 610 shall be located in the same bathroom or toilet and bathing area, such that travel between fixtures does not require travel between other parts of the residential dwelling unit.

11B-809.4.1 Subsequent bathrooms. In residential dwelling units with more than one bathroom, when a bathtub is installed in the first bathroom in compliance with Section 11B-809.4 and a shower compartment is provided in a subsequent bathroom, at least one shower compartment shall comply with Section 11B-608.

11B- 809.5 Residential dwelling units with communication features. Residential dwelling units required to provide communication features shall comply with Section 11B- 809.5.

11B-120 2025 CALIFORNIA BUILDING CODE

on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING

11B- 809.5.1 Building fire alarm system. Where a building fire alarm system is provided, the system wiring shall be extended to a point within the residential dwelling unit in the vicinity of the residential dwelling unit smoke detection system.

11B- 809.5.1.1 Alarm appliances. Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with Chapter 9, Section 907.5.2.3.3.

11B- 809.5.1.2 Activation. All visible alarm appliances provided within the residential dwelling unit for building fire alarm notification shall be activated upon activation of the building fire alarm in the portion of the building containing the residential dwelling unit.

11B- 809.5.2 Residential dwelling unit smoke detection system and carbon monoxide detection system. Residential dwelling unit smoke detection systems shall comply with Chapter 9, Section 907.2.11. Residential dwelling unit carbon monoxide detection systems shall comply with Chapter 4.

11B- 809.5.2.1 Activation. All visible alarm appliances provided within the residential dwelling unit for smoke detection notification shall be activated upon smoke detection. All visible alarm appliances provided within the residential dwelling unit for carbon monoxide detection notification shall be activated upon carbon monoxide detection.

11B- 809.5.3 Interconnection. The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection, building fire alarm activation and carbon monoxide detection.

11B- 809.5.4 Prohibited use. Visible alarm appliances used to indicate residential dwelling unit smoke detection, carbon monox- ide detection or building fire alarm activation shall not be used for any other purpose within the residential dwelling unit.

11B- 809.5.5 Residential dwelling unit primary entrance. Communication features shall be provided at the residential dwelling unit primary entrance complying with Section 11B- 809.5.5.

11B- 809.5.5.1 Notification. A hard-wired electric doorbell shall be provided. A button or switch shall be provided outside the residential dwelling unit primary entrance. Activation of the button or switch shall initiate an audible tone and visible signal within the residential dwelling unit. Where visible doorbell signals are located in sleeping areas, they shall have controls to deactivate the signal.

11B- 809.5.5.2 Identification. A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view.

11B- 809.5.6 Site, building or floor entrance. Where a system, including a closed-circuit system, permitting voice communication between a visitor and the occupant of the residential dwelling unit is provided, the system shall comply with Section 11B- 708.4.

11B-809.6 Residential dwelling units with adaptable features. Residential dwelling units with adaptable features shall comply with Sections 11B-809.7 through 11B-809.12.

11B-809.7 Accessible routes. An accessible route shall be provided complying with Section 11B-809.7. The accessible route shall pass through the primary entry door, through all rooms within the dwelling unit and exterior decks and balconies. The accessible route shall adjoin or overlap clear floor spaces and connect all exterior doors.

Exceptions:

1. An accessible route shall not be required from the interior of the unit into a basement.

2. An accessible route to a garage shall comply with Section 11B-208.3.3. 3. An accessible route shall not be required to rooms or spaces not located on the primary entry level of a multistory dwelling unit.

11B-809.7.1 Width. The clear width for the accessible route shall be 36 inches (914 mm) minimum.

Exception: The clear width shall be permitted to be reduced to 32 inches (813 mm) minimum at doors.

11B-809.7.2 Changes in level. Changes in level shall comply with Sections 11B-303.2 and 11B-303.3. Ramps complying with Section 11B-405, elevators complying with Section 11B-407 or platform lifts complying with Section 11B-410 shall be provided where changes in level exceed [1] / 2 inch (12.7 mm) high.

11B-809.8 Doors. Primary entry doors, required exit doors, secondary exterior doors and interior doors shall comply with Section 11B-809.8. Doors to small mechanical closets specifically dedicated to furnaces or hot water heaters shall not be required to comply with this section.

1. The clear width of doors shall comply with Section 11B-404.2.3.

2. Door hardware shall comply with Section 11B-404.2.7. 3. Door surfaces shall comply with Section 11B-404.2.10.

4. Doors in series shall comply with Section 11B-404.2.6.

11B-809.8.1 Door thresholds. Primary entry doors, required exit doors, and interior doors intended for user passage shall have thresholds complying with Section 11B-404.2.5. Secondary exterior door thresholds, including sliding door tracks, shall be [3] / 4 inch (19.1 mm) high maximum with a 1:2 maximum slope.

11B-809.8.2 Door opening force. Doors shall comply with Section 11B-404.2.9.

Exception: The opening force for primary entry exterior doors and secondary exterior doors shall be 8.5 pounds (38 N) maximum.

on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING

11B-809.8.3 Door maneuvering clearance. Minimum maneuvering clearances at doors shall comply with Section 11B-809.8.3. Maneuvering clearances shall extend the full width of the doorway and the required latch side or hinge side clearance.

1. At the dwelling unit side of the primary entry doors, secondary exterior doors, and required exit doors maneuvering clear- ances shall be 44 inches (1118 mm) minimum in length measured perpendicular to the face of the door in the closed position. The width of the maneuvering clearance shall extend 18 inches (457 mm) beyond the strike edge at the pull side of the door.

2. At interior doors maneuvering clearances shall be 42 inches (1067 mm) minimum in length on both sides of the door measured perpendicular to the face of the door in the closed position. A 39-inch (991 mm) minimum length is allowed at interior doors when a clear opening width of 34 inches (864 mm) minimum is provided. The width of the maneuvering clear- ance shall extend 18 inches (457 mm) beyond the strike edge at the pull side of the door.

11B-809.8.3.1 Floor or ground surface. Floor or ground surface within required maneuvering clearances shall not have slopes exceeding 1:48.

Exceptions: The floor or landing at primary entry doors, required exit doors and secondary exit doors where a change in eleva- tion occurs between the interior and the exterior surface of the floor or landing, shall comply with the following:

1. Exterior landings of impervious construction (e.g., concrete, brick, flagstone) serving primary entry doors and required exit doors are limited to not more than [1] / 2 inch (12.7 mm) of change in height between floor surfaces. Changes in level shall comply with Section 11B-809.7.2.

2. Exterior landings of pervious construction (e.g., wood decking with spaces) shall be the same level as the interior landing, except that secondary exterior doors may have no more than [1] / 2 inch (12.7 mm) of change in height between floor surfaces. Changes in level shall comply with Section 11B-809.7.2.

3. Secondary exterior doors onto decks, patios or balcony surfaces constructed of impervious materials (e.g., concrete, brick, flagstone) may have a maximum change in height from the interior landing of 4 inches (102 mm). Changes in height greater than [1] / 2 inch (12.7 mm) shall be accomplished by means of a ramp complying with Section 11B-405 or by means of a platform constructed to the level of the floor as illustrated in Figure 11B-809.8.3.1(3).

FIGURE 11B-809.8.3.1(3)—PLATFORM AT SECONDARY EXTERIOR DOOR

4. Secondary exterior doors onto decks, patios or balcony surfaces constructed of impervious materials (e.g., concrete, brick, flagstone) may have a maximum change in height from the interior landing of 1 inch (25 mm), provided a ramp with a maximum slope of 1:8 is permanently installed as illustrated in Figure 11B-809.8.3.1(4).

FIGURE 11B-809.8.3.1(4)—RAMP AT SECONDARY EXTERIOR DOOR

11B-122 2025 CALIFORNIA BUILDING CODE

on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING

11B-809.8.4 Door signal devices. Every primary entrance to a residential dwelling unit with adaptable features shall be provided with a door buzzer, bell, chime or equivalent. The activating mechanism shall be mounted 48 inches (1219 mm) maximum above the floor and connected to permanent wiring.

11B-809.9 Kitchens. Kitchens shall be on an accessible route and shall comply with this section .

11B-809.9.1 Clear floor space. Clear floor spaces 30 inches (762 mm) by 48 inches (1219 mm), with centerlines aligned with the centerline of the work surface, appliance, sink or fixture, shall be provided in the following locations: 1. For a parallel approach at the range. 2. For parallel or forward approach at a cooktop. 3. For a parallel or forward approach to the sink and to the work surface required by Sections 11B-809.9.3 and 11B-809.9.4. 4. For a parallel or forward approach to all other fixtures or appliances.

11B-809.9.2 Clear width. Kitchens shall have a minimum clear width measured between any cabinet, work surface or the face of any appliance (excluding handles and controls) and the opposing cabinet, work surface, appliance or wall as follows: a. U-shaped kitchens, designed with parallel approach at a sink, range, cooktop or other fixtures and appliances located at the base of the U without knee and toe clearance, shall provide a clear width of 60 inches (1524 mm) minimum. b. U-shaped kitchens, with a cooktop, sink or work surface located at the base of the U, that provides knee and toe space complying Sections 11B-809.9.3 and 11B-809.9.4 to allow for a forward approach, shall provide a clear width of 48 inches (1219 mm) minimum. c. All other kitchen designs shall provide a clear width of 48 inches (1219 mm) minimum.

FIGURE 11B-809.9.2 —CLEAR WIDTH AT KITCHENS

11B-809.9.3 Removable base cabinets. Knee and toe space complying with Section 11B-306 shall be provided at sinks and work surfaces required to comply with Section 11B-809.9.4.

Exception: Removable base cabinets shall be permitted under sinks and work surfaces provided that all of the following condi- tions are met:

a) base cabinets can be removed without the use of specialized tools or knowledge; b) the finish floor extends under the base cabinet; and c) the walls behind and surrounding the base cabinets are finished.

on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING

11B-809.9.4 Work surfaces. Work surfaces shall be 36 inches (914 mm) maximum above the finish floor with minimum lengths at the following locations as required by this section:

1. Linear length of 30 inches (762 mm) minimum for installation of a sink.

2. Linear length of 30 inches (762 mm) minimum for work surfaces.

3. A sink and work surface in a single integral unit 60 inches (1524 mm) minimum in length, is permitted.

11B-809.9.5 Lower shelving. Lower shelving and/or drawer space shall be provided at a height of 48 inches (1219 mm) maximum above the finish floor.

11B-809.9.6 Controls. Controls for faucets shall comply with Section 11B-309.1. Hand-operated metering faucets shall remain open for 10 seconds minimum.

11B-809.9.7 Exposed pipes and surfaces. Exposed water supply and drain pipes under sinks and lavatories shall comply with Section 11B-606.5.

11B-809.10 Bathrooms and powder rooms.

11B-809.10.1 General. All bathrooms on an accessible route within residential dwelling units with adaptable features shall comply with Sections 11B-809.7, 11B-809.8, 11B-809.10.5.2, 11B-809.10.6.4, 11B-809.10.7.3 and 11B-809.12.

11B-809.10.2 Number of complying bathrooms and fixtures. One bathroom and one fixture of each type within the dwelling unit shall be designed to comply with the following:

1. Maneuvering space in bathrooms shall comply with Section 11B-809.10.4.

2. Bathtubs shall comply with Section 11B-809.10.5.

3. Showers shall comply with Section 11B-809.10.6.

4. Water closets shall comply with Section 11B-809.10.7.

5. Lavatories, vanities, mirrors and towel bars shall comply with Section 11B-809.10.8. When two or more lavatories are provided, at least one shall comply with Section 11B-809.10.8.

6. Where both a tub and shower are provided in the bathroom, at least one shall be made accessible. Where two or more bath- rooms are provided, when a bathtub is installed in the first bathroom in compliance with Section 11B-809.10.5 and a shower compartment is provided in a subsequent bathroom, at least one shower compartment shall comply with Section 11B- 809.10.6.

11B-809.10.3 Powder rooms. Powder rooms shall be designed to comply with Sections 11B-809.7, 11B-809.8, 11B-809.10.7.3 and 11B-809.12. When the powder room is the only toilet facility located on an accessible level it shall, in addition, comply with Sections 11B-809.10.4, 11B-809.10.7 and 11B-809.10.8.

11B-809.10.4 Sufficient maneuvering space. Where doors swing into the bathrooms or powder rooms required to comply with Section 11B-809.10, a clear maneuvering space of 30 inches (762 mm) by 48 inches (1219 mm) minimum shall be provided outside the arc of the door swing. The clear maneuvering space shall be permitted to include knee and toe clearance under bathroom fixtures. Doors shall be permitted to encroach into the clear floor space or clearance for fixtures where clear maneuvering space is provided outside the arc of the door swing. A turning space is not required within the room.

11B-809.10.5 Bathtubs. Bathtubs required by Section 11B-809.10 shall comply with this section.

11B-809.10.5.1 Clear floor space. A clear floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be located with the long edge of the clear floor space parallel to the side of the bathtub or bathtub-shower combination. Controls shall be located on the wall at the foot of the bathtub. The edge of the clear floor space shall be flush with the control wall surface. The area under a lavatory, located at the control end of the tub, shall be permitted to encroach on the clear floor space provided the lavatory is 19 inches (483 mm) maximum in depth, and knee and toe clearance complying with Section 11B-306 is provided. Cabinets under lavatories and toilets shall not encroach on the clear floor space.

11B-809.10.5.2 Reinforcement for grab bars. Reinforcement for grabs bars shall comply with the following:

1. Where bathtubs are installed without surrounding walls reinforcement shall be provided for floor-mounted grab bars.

2. Where bathtubs are installed with surrounding walls, grab bar reinforcement shall be installed as follows:

a. At the control end wall and head end wall, between 30 inches (762 mm) maximum to 38 inches (965 mm) minimum above the finish floor, extending 28 inches (711 mm) minimum from the front edge of the bathtub to the back wall of the bathtub. The grab bar reinforcement shall be 8 inches (203 mm) minimum in height.

b. At the back wall, from 5 inches (127 mm) maximum above the bathtub rim to 38 inches (965 mm) minimum above the finish floor. Grab bar backing shall be installed horizontally to permit the installation of a 48-inch (1219 mm) grab bar with each end 6 inches (152 mm) maximum from the end walls of the bathtub.

11B-124 2025 CALIFORNIA BUILDING CODE

on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING

FIGURE 11B-809.10.5.2—REINFORCEMENT FOR GRAB BARS

11B-809.10.5.3 Controls. Controls and operating mechanisms shall comply with Section 11B-309.4.

Exception: Shower spray units are not required in bathtubs.

11B-809.10.5.4 Bathtub enclosures. Doors and panels of bathtub enclosures shall be constructed from approved, shatter- resistant materials. Hinged doors shall open outward. Glazing used in doors and panels of bathtub enclosures shall be fully tempered, laminated safety glass or approved plastic. When glass is used, it shall be [1] / 8 -inch (3.2 mm) thick minimum when fully tempered, or [1] / 4 -inch (6.4 mm) thick minimum when laminated, and shall pass the test requirements of this part, Chapter 24 Glass and Glazing. Plastics used in doors and panels of bathtub enclosures shall be of a shatter-resistant type.

11B-809.10.6 Showers. Showers required by Section 11B-809.10 shall comply with this section.

11B-809.10.6.1 Size. When one or more shower stalls are provided within the same dwelling unit, at least one shower stall shall comply with one of the following: 1. A transfer type shower compartment 36 inches (914 mm) wide by 36 inches (914 mm) deep, clear inside dimensions measured at center points of opposing sides, with an entrance opening 36 inches (914 mm) wide; or 2. A shower stall 30 inches (762 mm) deep minimum by 60 inches (1524 mm) wide minimum with an entrance opening 60 inches (1524 mm) minimum. A water closet shall be permitted to project 12 inches (305 mm) maximum into the opening provided that 36 inches (914 mm) minimum clear space is maintained between the water closet and the shower wall as illustrated in Figure 11B-809.10.6.1; or 3. A shower stall 36 inches (914 mm) deep by 60 inches (1524 mm) wide minimum with an entrance 36 inches (914 mm) mini- mum when a wall is installed on the opening side.

FIGURE 11B-809.10.6.1—SHOWERS

11B-809.10.6.2 Slope. The slope of the shower floor shall be [1] / 2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain. The floor surfaces shall be of Carborundum, grit-faced tile or of material providing equivalent slip resistance.

11B-809.10.6.3 Clearance. A clearance of 36 inches (914 mm) wide minimum by 48 inches (1219 mm) long minimum measured from the control wall shall be provided outside the shower as illustrated in Figure 11B-809.10.6.3.

on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING

FIGURE 11B-809.10.6.3 TRANSFER TYPE SHOWER CLEARANCE

11B-809.10.6.4 Reinforcement for grab bars. Reinforcement for grabs bars shall comply with the following: Continuous rein- forcement shall be installed in the walls of showers 30 inches (762 mm) maximum to 38 inches (965 mm) minimum above the finish floor. The grab bar reinforcement shall be 8 inches (203 mm) minimum in height. Glass-walled shower stalls shall provide rein- forcement for installation of floor-mounted or ceiling-mounted grab bars.

FIGURE 11B-809.10.6.4—REINFORCEMENT FOR GRAB BARS

11B-809.10.6.5 Thresholds. Where provided thresholds shall be 2 inches (51 mm) maximum in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from the horizontal). Thresholds [1] / 2 inch (12.7 mm) or less in height shall have a beveled or sloped angle not exceeding 1 unit vertical in 1 unit horizontal (45 degrees from the horizontal).

11B-809.10.6.6 Controls. Controls and operating mechanisms shall comply with Section 11B-309.4.

11B-809.10.6.7 Shower enclosures. Doors and panels of shower enclosures shall comply with Section 11B-809.10.5.4.

11B-809.10.7 Water closets. Water closets required by Section 11B-809.10 shall comply with this section.

11B-809.10.7.1 Floor space. The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicu- lar to the side wall. A floor space 48 inches (1219 mm) wide minimum by 36 inches (914 mm) deep minimum shall be provided in front of the water closet.

Exception: The 48-inch (1219 mm) minimum clear width may be reduced to 36 inches (914 mm) minimum for lavatories, cabi- nets, wing walls or privacy walls located immediately adjacent to a water closet which extend 24 inches (610 mm) maximum in depth.

11B-126 2025 CALIFORNIA BUILDING CODE

on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING

FIGURE 11B-809.10.7.1—FLOOR SPACE

11B-809.10.7.2 Location. Water closets shall be located within bathrooms in a manner that permits a grab bar to be installed on at least one side of the fixture. The centerline of the water closet shall be 17 inches (432 mm) minimum to 18 inches (457 mm) maxi- mum from a wall or partition that is 54 inches (1372 mm) minimum in length. In locations where water closets are adjacent to other walls, vanities, lavatories or bathtubs, the centerline of the fixture shall be 18 inches (457 mm) minimum from the obstacle.

11B-809.10.7.3 Reinforcement for grab bars. Reinforcement for grabs bars shall comply with the following:

1. Where water closets are not placed adjacent to a side wall capable of accommodating a grab bar, the bathroom shall have provisions for installation of floor-mounted, foldaway or similar alternative grab bars.

2. Where water closets are placed adjacent to a side wall, reinforcement shall be installed on both sides or one side and the back. Where reinforcement is installed at the back, it shall be installed between 30 inches (762 mm) maximum and 38 inches (965 mm) minimum above the finish floor. The grab bar reinforcement shall be 8 inches (203 mm) minimum in height. The backing shall be 40 inches (1016 mm) minimum in length.

aced adjacent to a side wall, reinforcement shall be installed on both sides or one side and the_ back. Where reinforcement is installed at the back, it shall be installed between 30 inches (762 mm) maximum and 38 inches (965 mm) minimum above the finish floor. The grab bar reinforcement shall be 8 inches (203 mm) minimum in height. The backing shall be 40 inches (1016 mm) minimum in length.

3. Where the water closet is located adjacent to lavatories, cabinets, wing walls or privacy walls, the grab bar reinforce- ment shall be 36 inches (914 mm) in length. Reinforcement installed at the side wall of the water closet shall be between 30 inches (762 mm) minimum to 38 inches (965 mm) maximum above the finish floor. The reinforcement shall be 10 inches (254 mm) maximum from the rear wall and shall extend 30 inches (762 mm) minimum in front of the water closet. The grab bar reinforcement shall be 8 inches (203 mm) minimum in height.

FIGURE 11B-809.10.7.3—REINFORCEMENT FOR GRAB BARS

11B-809.10.7.4 Seat height. Water closet seats shall be 15 inches (381 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat above the finish floor.

11B-809.10.7.5 Controls. Controls shall be mounted 44 inches (1118 mm) maximum above the finish floor. The force required to activate controls shall be 5 pounds (22.2 N) maximum.

11B-809.10.8 Lavatories, vanities, mirrors and towel bars. Bathrooms or powder rooms required to comply with Section 11B- 809.10 shall provide lavatories complying with this section . Where mirrors or towel bars are provided, no less than one of each shall comply with this section.

11B-809.10.8.1 Location. Lavatories without base cabinets shall be installed with the centerline 18 inches (457 mm) minimum from an adjoining wall or fixture to allow for forward approach. Lavatories with base cabinets shall be installed with the centerline 24 inches (610 mm) minimum from an adjoining wall or fixture to allow for a parallel approach. The top of the lavatory rim shall be 34 inches (864 mm) maximum above the finished floor.

11B-809.10.8.2 Floor space. A floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be provided centered on the lavatory.

on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING

11B-809.10.8.3 Cabinets . Cabinets shall be removable without the use of specialized knowledge and/or tools. The finished floor shall extend to the wall under the lavatory.

11B-809.10.8.4 Knee and toe clearance. Knee and toe clearance shall be provided and comply with Section 11B-306.

11B-809.10.8.5 Plumbing protection. Plumbing protection shall comply with Section 11B-809.9.7.

11B-809.10.8.6 Controls. Faucet controls and operating mechanisms shall comply with Section 11B-309.4.

11B-809.10.8.7 Mirrors and towel bars. Where mirrors are provided the bottom edge of the reflective surface shall be 40 inches (1016 mm) maximum above the finish floor. Where towel bars are provided, they shall be installed 40 inches (1016 mm) maximum above the finish floor to the top of the bar.

11B-809.11 Washing machines and clothes dryers. Where washing machines and clothes dryers are provided in residential dwelling units with adaptable features, one of each type shall be provided.

11B-809.12 Electrical receptacles, controls and switches. Electrical receptacles on branch circuits of 30 amperes or less, communica- tion system receptacles, controls and switches shall be located as follows:

1. Where there is no obstruction, 48 inches (1219 mm) maximum measured from the top of the receptacle box and 15 inches (381 mm) minimum measured from the bottom of the receptacle box to the finish floor.

2. Where the reach is over an obstruction, electrical receptacles, controls and switches shall comply with Sections 11B-308.3 and 11B-309.2.

3. When the reach is over a kitchen work surface and base cabinet, the work surface shall be 36 inches (914 mm) maximum above the finish floor and 25 [1] / 2 inches (650 mm) maximum in depth. The base cabinet shall be 24 inches (610 mm) maximum in depth. 4. Where receptacles are provided in a kitchen at a corner work surface, one receptacle shall be located 36 inches (915 mm) from either wall at the inside corner.

Exceptions:

a. Electrical receptacles installed as part of permanently installed baseboard heaters.

b. Electrical receptacles in floors adjacent to sliding panels or walls.

c. Baseboard electrical receptacles in relocatable partitions, window walls or other electrical convenience floor outlets.

d. Appliances (e.g., stoves, dishwashers, range hoods, microwave ovens and similar appliances) which have controls located on the appliance.

e. Electrical receptacles dedicated to specific appliances.

f. Circuit breakers.

FIGURE 11B-809.12—ELECTRICAL RECEPTACLES AT CORNER WORKSURFACES

Get a plain-English answer with a citation back to this text.

Ask AI about this code
Contents — 2025 California Building Code (Title 24, Part 2)
2025 California Building Code (Title 24, Part 2)
  1. Chapter 1 — ADMINISTRATION
  2. Chapter 2 — DEFINITIONS
  3. Chapter 3 — OCCUPANCY CLASSIFICATION AND USE
  4. Chapter 4 — SPECIAL DETAILED REQUIREMENTS BASED ON OCCUPANCY A…
  5. Chapter 5 — GENERAL BUILDING HEIGHTS AND AREAS
  6. Chapter 6 — TYPES OF CONSTRUCTION
  7. Chapter 7 — FIRE AND SMOKE PROTECTION FEATURES
  8. Chapter 7A — MATERIALS AND CONSTRUCTION METHODS FOR EXTERIOR W…
  9. Chapter 8 — INTERIOR FINISHES
  10. Chapter 9 — FIRE PROTECTION AND LIFE SAFETY SYSTEMS
  11. Chapter 10 — MEANS OF EGRESS
  12. Chapter 11 — RESERVED
  13. Chapter 11A — HOUSING ACCESSIBILITY
  14. Chapter 11B — ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMM…
    Overview
    1. Section 11B-101 — PURPOSE
    2. Section 11B-104 — CONVENTIONS
    3. Section 11B-105 — REFERENCED STANDARDS
    4. Section 11B-106 — DEFINITIONS
    5. Section 11B-201 — APPLICATION
    6. Section 11B-202 — EXISTING BUILDINGS AND FACILITIES
    7. Section 11B-203 — GENERAL EXCEPTIONS
    8. Section 11B-204 — PROTRUDING OBJECTS
    9. Section 11B-205 — OPERABLE PARTS
    10. Section 11B-206 — ACCESSIBLE ROUTES
    11. Section 11B-207 — ACCESSIBLE MEANS OF EGRESS
    12. Section 11B-208 — PARKING SPACES
    13. Section 11B-209 — PASSENGER DROP-OFF AND LOADING ZONES AND BUS…
    14. Section 11B-210 — STAIRWAYS
    15. Section 11B-211 — DRINKING FOUNTAINS AND BOTTLE-FILLING STATIONS
    16. Section 11B-212 — KITCHENS, KITCHENETTES, WET BARS AND SINKS
    17. Section 11B-213 — TOILET FACILITIES AND BATHING FACILITIES
    18. Section 11B-214 — WASHING MACHINES AND CLOTHES DRYERS
    19. Section 11B-215 — FIRE ALARM SYSTEMS AND CARBON MONOXIDE ALARM…
    20. Section 11B-216 — SIGNS
    21. Section 11B-217 — TELEPHONES
    22. Section 11B-218 — TRANSPORTATION FACILITIES
    23. Section 11B-219 — ASSISTIVE LISTENING SYSTEMS
    24. Section 11B-220 — AUTOMATIC TELLER MACHINES, FARE MACHINES AND…
    25. Section 11B-221 — ASSEMBLY AREAS
    26. Section 11B-222 — DRESSING, FITTING AND LOCKER ROOMS
    27. Section 11B-223 — MEDICAL CARE AND LONG-TERM CARE FACILITIES
    28. Section 11B-224 — TRANSIENT LODGING GUEST ROOMS, HOUSING
    29. Section 11B-225 — STORAGE
    30. Section 11B-226 — DINING SURFACES AND WORK SURFACES
    31. Section 11B-227 — SALES AND SERVICE
    32. Section 11B-228 — DEPOSITORIES, VENDING MACHINES, CHANGE MACHI…
    33. Section 11B-229 — WINDOWS
    34. Section 11B-230 — TWO-WAY COMMUNICATION SYSTEMS
    35. Section 11B-231 — JUDICIAL FACILITIES
    36. Section 11B-232 — DETENTION FACILITIES AND CORRECTIONAL FACILI…
    37. Section 11B-233 — PUBLIC HOUSING FACILITIES
    38. Section 11B-234 — AMUSEMENT RIDES
    39. Section 11B-235 — RECREATIONAL BOATING FACILITIES
    40. Section 11B-236 — EXERCISE MACHINES AND EQUIPMENT
    41. Section 11B-237 — FISHING PIERS AND PLATFORMS
    42. Section 11B-238 — GOLF FACILITIES
    43. Section 11B-239 — MINIATURE GOLF FACILITIES
    44. Section 11B-240 — PLAY AREAS
    45. Section 11B-241 — SAUNAS AND STEAM ROOMS
    46. Section 11B-242 — SWIMMING POOLS, WADING POOLS AND SPAS
    47. Section 11B-243 — SHOOTING FACILITIES WITH FIRING POSITIONS
    48. Section 11B-244 — RELIGIOUS FACILITIES
    49. Section 11B-245 — PUBLIC ACCOMMODATIONS LOCATED IN PRIVATE RES…
    50. Section 11B-246 — OUTDOOR DEVELOPED AREAS
    51. Section 11B-247 — DETECTABLE WARNINGS AND DETECTABLE DIRECTION…
    52. Section 11B-248 — COMMON USE AREAS AND EMPLOYEE WORK AREAS
    53. Section 11B-249 — ADULT CHANGING FACILITIES
    54. Section 11B-250 — CIRCULATION PATHS
    55. Section 11B-301 — GENERAL
    56. Section 11B-302 — FLOOR OR GROUND SURFACES
    57. Section 11B-303 — CHANGES IN LEVEL
    58. Section 11B-304 — TURNING SPACE
    59. Section 11B-305 — CLEAR FLOOR OR GROUND SPACE
    60. Section 11B-306 — KNEE AND TOE CLEARANCE
    61. Section 11B-307 — PROTRUDING OBJECTS
    62. Section 11B-308 — REACH RANGES
    63. Section 11B-309 — OPERABLE PARTS
    64. Section 11B-401 — GENERAL
    65. Section 11B-402 — ACCESSIBLE ROUTES
    66. Section 11B-403 — W ALKING SURFACES
    67. Section 11B-404 — DOORS, DOORWAYS AND GATES
    68. Section 11B-405 — RAMPS
    69. Section 11B-406 — CURB RAMPS, BLENDED TRANSITIONS AND ISLANDS
    70. Section 11B-407 — ELEVATORS
    71. Section 11B-408 — LIMITED-USE/LIMITED-APPLICATION ELEVATORS
    72. Section 11B-409 — PRIVATE RESIDENCE ELEVATORS
    73. Section 11B-410 — PLATFORM LIFTS
    74. Section 11B-411 — DESTINATION-ORIENTED ELEVATORS
    75. Section 11B-501 — GENERAL
    76. Section 11B-502 — PARKING SPACES
    77. Section 11B-503 — PASSENGER DROP-OFF AND LOADING ZONES
    78. Section 11B-504 — STAIRWAYS
    79. Section 11B-505 — HANDRAILS
    80. Section 11B-601 — GENERAL
    81. Section 11B-602 — DRINKING FOUNTAINS AND BOTTLE-FILLING STATIONS
    82. Section 11B-603 — TOILET AND BATHING ROOMS
    83. Section 11B-604 — WATER CLOSETS AND TOILET COMPARTMENTS
    84. Section 11B-605 — URINALS
    85. Section 11B-606 — LAVATORIES AND SINKS
    86. Section 11B-607 — BATHTUBS
    87. Section 11B-608 — SHOWER COMPARTMENTS
    88. Section 11B-609 — GRAB BARS
    89. Section 11B-610 — SEATS
    90. Section 11B-611 — WASHING MACHINES AND CLOTHES DRYERS
    91. Section 11B-612 — SAUNAS AND STEAM ROOMS
    92. Section 11B-701 — GENERAL
    93. Section 11B-702 — FIRE ALARM SYSTEMS
    94. Section 11B-703 — SIGNS
    95. Section 11B-704 — TELEPHONES
    96. Section 11B-705 — DETECTABLE WARNINGS AND DETECTABLE DIRECTION…
    97. Section 11B-706 — ASSISTIVE LISTENING SYSTEMS
    98. Section 11B-707 — AUTOMATIC TELLER MACHINES, FARE MACHINES AND…
    99. Section 11B-708 — TWO-WAY COMMUNICATION SYSTEMS
    100. Section 11B-801 — GENERAL
    101. Section 11B-802 — WHEELCHAIR SPACES, COMPANION SEATS AND DESIG…
    102. Section 11B-803 — DRESSING, FITTING AND LOCKER ROOMS
    103. Section 11B-804 — KITCHENS, KITCHENETTES AND WET BARS
    104. Section 11B-805 — MEDICAL CARE AND LONG-TERM CARE FACILITIES
    105. Section 11B-806 — TRANSIENT LODGING GUEST ROOMS
    106. Section 11B-807 — HOLDING CELLS AND HOUSING CELLS
    107. Section 11B-808 — COURTROOMS
    108. Section 11B-809 — RESIDENTIAL DWELLING UNITS
    109. Section 11B-810 — TRANSPORTATION FACILITIES
    110. Section 11B-811 — STORAGE
    111. Section 11B-812 — ELECTRIC VEHICLE CHARGING STATIONS
    112. Section 11B-813 — ADULT CHANGING FACILITIES
    113. Section 11B-901 — GENERAL
    114. Section 11B-902 — DINING SURFACES AND WORK SURFACES
    115. Section 11B-903 — BENCHES
    116. Section 11B-904 — CHECK-OUT AISLES AND SALES AND SERVICE COUNT…
    117. Section 11B-1001 — GENERAL
    118. Section 11B-1002 — AMUSEMENT RIDES
    119. Section 11B-1003 — RECREATIONAL BOATING FACILITIES
    120. Section 11B-1004 — EXERCISE MACHINES AND EQUIPMENT
    121. Section 11B-1005 — FISHING PIERS AND PLATFORMS
    122. Section 11B-1006 — GOLF FACILITIES
    123. Section 11B-1007 — MINIATURE GOLF FACILITIES
    124. Section 11B-1008 — PLAY AREAS
    125. Section 11B-1009 — SWIMMING POOLS, WADING POOLS AND SPAS
    126. Section 11B-1010 — SHOOTING FACILITIES WITH FIRING POSITIONS
  15. Chapter 12 — INTERIOR ENVIRONMENT
  16. Chapter 13 — ENERGY EFFICIENCY
  17. Chapter 14 — EXTERIOR WALLS
  18. Chapter 15 — ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
  19. Chapter 16 — STRUCTURAL DESIGN
  20. Chapter 16A — STRUCTURAL DESIGN
  21. Chapter 17 — SPECIAL INSPECTIONS AND TESTS
  22. Chapter 17A — SPECIAL INSPECTIONS AND TESTS
  23. Chapter 18 — SOILS AND FOUNDATIONS
  24. Chapter 18A — SOILS AND FOUNDATIONS
  25. Chapter 19 — CONCRETE
  26. Chapter 19A — CONCRETE
  27. Chapter 20 — ALUMINUM
  28. Chapter 21 — MASONRY
  29. Chapter 21A — MASONRY
  30. Chapter 22 — STEEL
  31. Chapter 22A — STEEL
  32. Chapter 23 — WOOD
  33. Chapter 24 — GLASS AND GLAZING
  34. Chapter 25 — GYPSUM PANEL PRODUCTS AND PLASTER
  35. Chapter 26 — PLASTIC
  36. Chapter 27 — ELECTRICAL
  37. Chapter 28 — MECHANICAL SYSTEMS
  38. Chapter 29 — PLUMBING SYSTEMS
  39. Chapter 30 — ELEVATORS AND CONVEYING SYSTEMS
  40. Chapter 31 — SPECIAL CONSTRUCTION
  41. Chapter 31A — SYSTEMS FOR WINDOW CLEANING OR EXTERIOR BUILDING…
  42. Chapter 31B — PUBLIC POOLS
  43. Chapter 31C — RADIATION
  44. Chapter 31D — FOOD ESTABLISHMENTS
  45. Chapter 31F — MARINE OIL TERMINALS
  46. Chapter 32 — ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
  47. Chapter 33 — SAFEGUARDS DURING CONSTRUCTION
  48. Chapter 34 — RESERVED
  49. Chapter 35 — REFERENCED STANDARDS
  50. Appendix A — EMPLOYEE QUALIFICATIONS
  51. Appendix B — BOARD OF APPEALS
  52. Appendix C — GROUP U—AGRICULTURAL BUILDINGS
  53. Appendix D — FIRE DISTRICTS
  54. Appendix E — RESERVED
  55. Appendix F — RODENTPROOFING
  56. Appendix G — FLOOD-RESISTANT CONSTRUCTION
  57. Appendix H — SIGNS
  58. Appendix I — PATIO COVERS
  59. Appendix J — GRADING
  60. Appendix K — GROUP R-3 AND GROUP R-3.1 OCCUPANCIES PROTECTED B…
  61. Appendix L — EARTHQUAKE RECORDING INSTRUMENTATION
  62. Appendix M — TSUNAMI-GENERATED FLOOD HAZARDS
  63. Appendix N — REPLICABLE BUILDINGS
  64. Appendix O — PERFORMANCE-BASED APPLICATION
  65. Appendix P — SLEEPING LOFTS
  66. Appendix Q — EMERGENCY HOUSING

GoCodebook provides public access, search, citation, multilingual explanation, and practical interpretation of legally adopted building regulations. It is not a substitute for the official ICC or California code publications.