Section 11B-404 — DOORS, DOORWAYS AND GATES
2025 California Building Code (Title 24, Part 2) · 2025 edition · updated 2026-07-29 · California
Italicized text is a California amendment to the model code, as printed in the official publication.
11B- 404.1 General. Doors, doorways and gates that are part of an accessible route shall comply with Section 11B- 404 .
Exceptions:
1. Doors, doorways and gates designed to be operated only by security personnel shall not be required to comply with Sections 11B- 404.2.7, 11B- 404.2.8, 11B- 404.2.9, 11B- 404.3.2 and 11B- 404.3.4 through 11B- 404.3.7. A sign visible from the approach side complying with Section 11B-703.5 shall be posted stating “Entry restricted and controlled by security personnel”.
2. At detention and correctional facilities, doors, doorways and gates designed to be operated only by security personnel shall not be required to comply with Sections 11B-404.2.7, 11B-404.2.8, 11B-404.2.9, 11B-404.3.2 and 11B-404.3.4 through 11B- 404.3.7.
11B-50 2025 CALIFORNIA BUILDING CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING
11B- 404.2 Manual doors, doorways and manual gates. Manual doors and doorways and manual gates intended for user passage shall comply with Section 11B- 404.2.
11B- 404.2.1 Revolving doors, gates and turnstiles. Revolving doors, revolving gates and turnstiles shall not be part of an accessible route.
11B- 404.2.2 Double-leaf doors and gates. At least one of the active leaves of doorways with two leaves shall comply with Sections 11B- 404.2.3 and 11B- 404.2.4.
11B- 404.2.3 Clear width. Door openings shall provide a clear width of 32 inches ( 813 mm) minimum. Clear openings of doorways with swinging doors shall be measured between the face of the door and the stop, with the door open 90 degrees. Openings more than 24 inches (610 mm) deep shall provide a clear opening of 36 inches ( 914 mm) minimum. There shall be no projections into the required clear opening width lower than 34 inches ( 864 mm) above the finish floor or ground. Projections into the clear opening width between 34 inches ( 864 mm) and 80 inches ( 2032 mm) above the finish floor or ground shall not exceed 4 inches ( 102 mm).
Exceptions:
In alterations, a projection of [5] / 8 inch ( 15.9 mm) maximum into the required clear width shall be permitted for the latch side stop.
Door closers and door stops shall be permitted to be 78 inches ( 1981 mm) minimum above the finish floor or ground.
FIGURE 11B- 404.2.3—CLEAR WIDTH OF DOORWAYS
11B- 404.2.4 Maneuvering clearances. Minimum maneuvering clearances at doors and gates shall comply with Section 11B- 404.2.4. Maneuvering clearances shall extend the full width of the doorway and the required latch side or hinge side clearance.
Exception: Reserved.
11B-404.2.4.1 Swinging doors and gates. Swinging doors and gates shall have maneuvering clearances complying with Table 11B-404.2.4.1.
TABLE 11B-404.2.4.1—MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES
| TYPE OF USE | TYPE OF USE | MINIMUM MANEUVERING CLEARANCE | MINIMUM MANEUVERING CLEARANCE |
|---|---|---|---|
| Approach direction | Door or gate side | Perpendicular to doorway | Parallel to doorway (beyond latch side unless noted) |
| From front | Pull | 60 inches (1524 mm) | 18 inches (457 mm)5 |
| From front | Push | 48 inches (1219 mm) | 0 inches (0 mm)1 |
| From hinge side | Pull | 60 inches (1524 mm) | 36 inches (914 mm) |
| From hinge side | Push | 44 inches (1118 mm)2 | 22 inches (559 mm)3 |
| From latch side | Pull | 60 inches (1524 mm) | 24 inches (610 mm) |
| From latch side | Push | 44 inches (1118 mm)4 | 24 inches (610 mm) |
| 1. Add 12 inches (305 mm) if closer and latch are provided. 2. Add_4 inches (102 mm)_ if closer and latch are provided. 3. Beyond hinge side. 4. Add_4 inches (102 mm)_ if closer is provided. 5. Add 6 inches (152 mm) at exterior side of exterior doors. |
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING
FIGURE 11B- 404.2.4.1—MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES
11B-52 2025 CALIFORNIA BUILDING CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING
FIGURE 11B- 404.2.4.1—MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES—continued
11B- 404.2.4.2 Doorways without doors or gates, sliding doors and folding doors. Doorways less than 36 inches ( 914 mm) wide without doors or gates, sliding doors or folding doors shall have maneuvering clearances complying with Table 11B- 404.2.4.2.
| TABLE 11B-404.2.4.2—MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS OR GATES, MANUAL SLIDING DOORS and MANUAL FOLDING DOORS |
||
|---|---|---|
| MINIMUM MANEUVERING CLEARANCE | MINIMUM MANEUVERING CLEARANCE | |
| Approach direction | Perpendicular to doorway | Parallel to doorway (beyond stop/latch side unless noted) |
| From front | 48 inches (1219 mm) | 0 inches (0 mm) |
| From side1 | 42 inches (1067 mm) | 0 inches (0 mm) |
| From pocket/hinge side | 42 inches (1067 mm) | 22 inches (559 mm)2 |
| From stop/latch side | 42 inches (1067 mm) | 24 inches (610 mm) |
| 1. Doorway with no door only. 2. Beyond pocket/hinge side. |
FIGURE 11B -404.2.4.2—MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS, SLIDING DOORS, GATES and FOLDING DOORS
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING
11B- 404.2.4.3 Recessed doors and gates. Maneuvering clearances for forward approach shall be provided when any obstruction within 18 inches ( 457 mm) of the latch side at an interior doorway, or within 24 inches (610 mm) of the latch side of an exterior doorway, projects more than 8 inches ( 203 mm) beyond the face of the door, measured perpendicular to the face of the door or gate.
FIGURE 11B-404.2.4.3—MANEUVERING CLEARANCES AT RECESSED DOORS AND GATES
11B- 404.2.4.4 Floor or ground surface. Floor or ground surface within required maneuvering clearances shall comply with Section 11B- 302. Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted.
Exceptions:
Reserved.
Changes in level at thresholds complying with Section 11B- 404.2.5 shall be permitted. 11B- 404.2.5 Thresholds. Thresholds, if provided at doorways, shall be [1] / 2 inch ( 12.7 mm) high maximum. Raised thresholds and changes in level at doorways shall comply with Sections 11B- 302 and 11B- 303 .
Exception: Reserved.
11B- 404.2.6 Doors in series and gates in series. The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches ( 1219 mm) minimum plus the width of doors or gates swinging into the space.
11B-54 2025 CALIFORNIA BUILDING CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING
FIGURE 11B -404.2.6—DOORS IN SERIES AND GATES IN SERIES
11B- 404.2.7 Door and gate hardware. Handles, pulls, latches, locks and other operable parts on doors and gates shall comply with Section 11B- 309.4. Operable parts of such hardware shall be 34 inches ( 864 mm) minimum and 44 inches (1118 mm) maximum above the finish floor or ground. Where sliding doors are in the fully open position, operating hardware shall be exposed and usable from both sides.
Exceptions:
Existing locks shall be permitted in any location at existing glazed doors without stiles, existing overhead rolling doors or grilles and similar existing doors or grilles that are designed with locks that are activated only at the top or bottom rail.
Access gates in barrier walls and fences protecting pools, spas and hot tubs shall be permitted to have operable parts of the release of latch on self-latching devices at 54 inches ( 1372 mm) maximum above the finish floor or ground provided the self-latching devices are not also self-locking devices and operated by means of a key, electronic opener or integral combination lock.
11B- 404.2.8 Closing speed. Door and gate closing speed shall comply with Section 11B- 404.2.8.
11B- 404.2.8.1 Door closers and gate closers. Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum.
11B- 404.2.8.2 Spring hinges. Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum.
11B- 404.2.9 Door and gate opening force. The force for pushing or pulling open a door or gate shall be as follows:
- Interior hinged doors and gates: 5 pounds (22.2 N) maximum.
- Sliding or folding doors: 5 pounds (22.2 N) maximum. 3. Required fire doors: the minimum opening force allowable by the appropriate administrative authority, not to exceed 15 pounds (66.7 N). 4. Exterior hinged doors: 5 pounds (22.2 N) maximum.
These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door or gate in a closed position.
Exception: When, at a single location, one of every eight exterior door leafs, or fraction of eight, is a powered door, other exterior doors at the same location, serving the same interior space, may have a maximum opening force of 8.5 pounds (37.8 N). The powered leaf(s) shall be located closest to the accessible route. a. Powered doors shall comply with Section 11B-404.3. Powered doors shall be fully automatic doors complying with Builders Hardware Manufacturers’ Association (BHMA) A156.10 or low energy operated doors complying with BHMA A156.19.
b. Powered doors serving a building or facility with an occupancy of 150 or more shall be provided with a back-up battery or back-up generator. The back-up power source shall be able to cycle the door a minimum of 100 cycles. c. Powered doors shall be controlled on both the interior and exterior sides of the doors by sensing devices, push plates, vertical actuation bars or other similar operating devices complying with Section 11B-309. At each location where push plates are provided there shall be two push plates; the centerline of one push plate shall be 7 inches (178 mm) minimum and 8 inches (203 mm) maximum above the floor or ground surface and the centerline of the second push plate shall be 30 inches (762 mm) minimum and 44 inches (1118 mm) maximum above
other similar operating devices complying with Section 11B-309._ At each location where push plates are provided there shall be two push plates; the centerline of one push plate shall be 7 inches (178 mm) minimum and 8 inches (203 mm) maximum above the floor or ground surface and the centerline of the second push plate shall be 30 inches (762 mm) minimum and 44 inches (1118 mm) maximum above
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING
the floor or ground surface. Each push plate shall be a minimum of 4 inches (102 mm) diameter or a minimum of 4 inches by 4 inches (102 mm by 102 mm) square and shall display the International Symbol of Accessibility complying with Section 11B-703.7.
At each location where vertical actuation bars are provided the operable portion shall be located so the bottom is 5 inches (127 mm) maximum above the floor or ground surface and the top is 35 inches (889 mm) minimum above the floor or ground surface. The operable portion of each vertical actuation bar shall be a minimum of 2 inches (51 mm) wide and shall display the International Symbol of Accessibility complying with Section 11B-703.7.
Where push plates, vertical actuation bars or other similar operating devices are provided, they shall be placed in a conspic- uous location. A level and clear floor or ground space for forward or parallel approach complying with Section 11B-305 shall be provided, centered on the operating device. Doors shall not swing into the required clear floor or ground space.
d. Signs identifying the accessible entrance required by Section 11B-216.6 shall be placed on, or immediately adjacent to, each powered door. Signs shall be provided in compliance with BHMA A156.10 or BHMA A156.19, as applicable.
e. In addition to the requirements of Item d, where a powered door is provided in buildings or facilities containing assembly occupancies of 300 or more, a sign displaying the International Symbol of Accessibility measuring 6 inches by 6 inches (152 mm by 152 mm), complying with Section 11B-703.7, shall be provided above the door on both the interior and exte- rior sides of each powered door.
11B- 404.2.10 Door and gate surfaces. Swinging door and gate surfaces within 10 inches ( 254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door or gate. Parts creating horizontal or vertical joints in these surfaces shall be within [1] / 16 inch (1.6 mm) of the same plane as the other and be free of sharp or abrasive edges. Cavities created by added kick plates shall be capped.
Exceptions:
Sliding doors shall not be required to comply with Section 11B- 404.2.10.
Tempered glass doors without stiles and having a bottom rail or shoe with the top leading edge tapered at 60 degrees minimum from the horizontal shall not be required to meet the 10 inch ( 254 mm) bottom smooth surface height requirement.
Doors and gates that do not extend to within 10 inches ( 254 mm) of the finish floor or ground shall not be required to comply with Section 11B- 404.2.10.
Reserved.
11B- 404.2.11 Vision lights. Doors, gates and side lights adjacent to doors or gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel located 43 inches ( 1092 mm) maximum above the finish floor.
Exception: Glazing panels with the lowest part more than 66 inches ( 1676 mm) from the finish floor or ground shall not be required to comply with Section 11B- 404.2.11.
11B- 404.3 Automatic and power-assisted doors and gates. Automatic doors and automatic gates shall comply with Section 11B- 404.3. Full-powered automatic doors shall comply with ANSI/BHMA A156.10. Low-energy and power-assisted doors shall comply with ANSI/BHMA A156.19.
11B- 404.3.1 Clear width. Doorways shall provide a clear opening of 32 inches ( 813 mm) minimum in power-on and power-off mode. The minimum clear width for automatic door systems in a doorway shall provide a clear, unobstructed opening of 32 inches (813 mm) with one leaf positioned at an angle of 90 degrees from its closed position.
11B- 404.3.2 Maneuvering clearance. Clearances at power-assisted doors and gates shall comply with Section 11B- 404.2.4. Clearances at automatic doors and gates without standby power and serving an accessible means of egress shall comply with Section 11B- 404.2.4.
Exception: Where automatic doors and gates remain open in the power-off condition, compliance with Section 11B- 404.2.4 shall not be required.
11B- 404.3.3 Thresholds. Thresholds and changes in level at doorways shall comply with Section 11B- 404.2.5.
11B- 404.3.4 Doors in series and gates in series. Doors in series and gates in series shall comply with Section 11B- 404.2.6.
11B- 404.3.5 Controls. Manually operated controls shall comply with Section 11B- 309. The clear floor space adjacent to the control shall be located beyond the arc of the door swing.
11B- 404.3.6 Break out opening. Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches ( 813 mm) minimum when operated in emergency mode.
Exception: Where manual swinging doors and gates comply with Section 11B- 404.2 and serve the same means of egress compliance with Section 11B- 404.3.6 shall not be required.
11B- 404.3.7 Revolving doors, revolving gates and turnstiles. Revolving doors, revolving gates and turnstiles shall not be part of an accessible route.
11B-56 2025 CALIFORNIA BUILDING CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸ Contents — 2025 California Building Code (Title 24, Part 2)
- Chapter 1 — ADMINISTRATION
- Chapter 2 — DEFINITIONS
- Chapter 3 — OCCUPANCY CLASSIFICATION AND USE
- Chapter 4 — SPECIAL DETAILED REQUIREMENTS BASED ON OCCUPANCY A…
- Chapter 5 — GENERAL BUILDING HEIGHTS AND AREAS
- Chapter 6 — TYPES OF CONSTRUCTION
- Chapter 7 — FIRE AND SMOKE PROTECTION FEATURES
- Chapter 7A — MATERIALS AND CONSTRUCTION METHODS FOR EXTERIOR W…
- Chapter 8 — INTERIOR FINISHES
- Chapter 9 — FIRE PROTECTION AND LIFE SAFETY SYSTEMS
- Chapter 10 — MEANS OF EGRESS
- Chapter 11 — RESERVED
- Chapter 11A — HOUSING ACCESSIBILITY
-
▸ Chapter 11B — ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMM…
Overview- Section 11B-101 — PURPOSE
- Section 11B-104 — CONVENTIONS
- Section 11B-105 — REFERENCED STANDARDS
- Section 11B-106 — DEFINITIONS
- Section 11B-201 — APPLICATION
- Section 11B-202 — EXISTING BUILDINGS AND FACILITIES
- Section 11B-203 — GENERAL EXCEPTIONS
- Section 11B-204 — PROTRUDING OBJECTS
- Section 11B-205 — OPERABLE PARTS
- Section 11B-206 — ACCESSIBLE ROUTES
- Section 11B-207 — ACCESSIBLE MEANS OF EGRESS
- Section 11B-208 — PARKING SPACES
- Section 11B-209 — PASSENGER DROP-OFF AND LOADING ZONES AND BUS…
- Section 11B-210 — STAIRWAYS
- Section 11B-211 — DRINKING FOUNTAINS AND BOTTLE-FILLING STATIONS
- Section 11B-212 — KITCHENS, KITCHENETTES, WET BARS AND SINKS
- Section 11B-213 — TOILET FACILITIES AND BATHING FACILITIES
- Section 11B-214 — WASHING MACHINES AND CLOTHES DRYERS
- Section 11B-215 — FIRE ALARM SYSTEMS AND CARBON MONOXIDE ALARM…
- Section 11B-216 — SIGNS
- Section 11B-217 — TELEPHONES
- Section 11B-218 — TRANSPORTATION FACILITIES
- Section 11B-219 — ASSISTIVE LISTENING SYSTEMS
- Section 11B-220 — AUTOMATIC TELLER MACHINES, FARE MACHINES AND…
- Section 11B-221 — ASSEMBLY AREAS
- Section 11B-222 — DRESSING, FITTING AND LOCKER ROOMS
- Section 11B-223 — MEDICAL CARE AND LONG-TERM CARE FACILITIES
- Section 11B-224 — TRANSIENT LODGING GUEST ROOMS, HOUSING
- Section 11B-225 — STORAGE
- Section 11B-226 — DINING SURFACES AND WORK SURFACES
- Section 11B-227 — SALES AND SERVICE
- Section 11B-228 — DEPOSITORIES, VENDING MACHINES, CHANGE MACHI…
- Section 11B-229 — WINDOWS
- Section 11B-230 — TWO-WAY COMMUNICATION SYSTEMS
- Section 11B-231 — JUDICIAL FACILITIES
- Section 11B-232 — DETENTION FACILITIES AND CORRECTIONAL FACILI…
- Section 11B-233 — PUBLIC HOUSING FACILITIES
- Section 11B-234 — AMUSEMENT RIDES
- Section 11B-235 — RECREATIONAL BOATING FACILITIES
- Section 11B-236 — EXERCISE MACHINES AND EQUIPMENT
- Section 11B-237 — FISHING PIERS AND PLATFORMS
- Section 11B-238 — GOLF FACILITIES
- Section 11B-239 — MINIATURE GOLF FACILITIES
- Section 11B-240 — PLAY AREAS
- Section 11B-241 — SAUNAS AND STEAM ROOMS
- Section 11B-242 — SWIMMING POOLS, WADING POOLS AND SPAS
- Section 11B-243 — SHOOTING FACILITIES WITH FIRING POSITIONS
- Section 11B-244 — RELIGIOUS FACILITIES
- Section 11B-245 — PUBLIC ACCOMMODATIONS LOCATED IN PRIVATE RES…
- Section 11B-246 — OUTDOOR DEVELOPED AREAS
- Section 11B-247 — DETECTABLE WARNINGS AND DETECTABLE DIRECTION…
- Section 11B-248 — COMMON USE AREAS AND EMPLOYEE WORK AREAS
- Section 11B-249 — ADULT CHANGING FACILITIES
- Section 11B-250 — CIRCULATION PATHS
- Section 11B-301 — GENERAL
- Section 11B-302 — FLOOR OR GROUND SURFACES
- Section 11B-303 — CHANGES IN LEVEL
- Section 11B-304 — TURNING SPACE
- Section 11B-305 — CLEAR FLOOR OR GROUND SPACE
- Section 11B-306 — KNEE AND TOE CLEARANCE
- Section 11B-307 — PROTRUDING OBJECTS
- Section 11B-308 — REACH RANGES
- Section 11B-309 — OPERABLE PARTS
- Section 11B-401 — GENERAL
- Section 11B-402 — ACCESSIBLE ROUTES
- Section 11B-403 — W ALKING SURFACES
- Section 11B-404 — DOORS, DOORWAYS AND GATES
- Section 11B-405 — RAMPS
- Section 11B-406 — CURB RAMPS, BLENDED TRANSITIONS AND ISLANDS
- Section 11B-407 — ELEVATORS
- Section 11B-408 — LIMITED-USE/LIMITED-APPLICATION ELEVATORS
- Section 11B-409 — PRIVATE RESIDENCE ELEVATORS
- Section 11B-410 — PLATFORM LIFTS
- Section 11B-411 — DESTINATION-ORIENTED ELEVATORS
- Section 11B-501 — GENERAL
- Section 11B-502 — PARKING SPACES
- Section 11B-503 — PASSENGER DROP-OFF AND LOADING ZONES
- Section 11B-504 — STAIRWAYS
- Section 11B-505 — HANDRAILS
- Section 11B-601 — GENERAL
- Section 11B-602 — DRINKING FOUNTAINS AND BOTTLE-FILLING STATIONS
- Section 11B-603 — TOILET AND BATHING ROOMS
- Section 11B-604 — WATER CLOSETS AND TOILET COMPARTMENTS
- Section 11B-605 — URINALS
- Section 11B-606 — LAVATORIES AND SINKS
- Section 11B-607 — BATHTUBS
- Section 11B-608 — SHOWER COMPARTMENTS
- Section 11B-609 — GRAB BARS
- Section 11B-610 — SEATS
- Section 11B-611 — WASHING MACHINES AND CLOTHES DRYERS
- Section 11B-612 — SAUNAS AND STEAM ROOMS
- Section 11B-701 — GENERAL
- Section 11B-702 — FIRE ALARM SYSTEMS
- Section 11B-703 — SIGNS
- Section 11B-704 — TELEPHONES
- Section 11B-705 — DETECTABLE WARNINGS AND DETECTABLE DIRECTION…
- Section 11B-706 — ASSISTIVE LISTENING SYSTEMS
- Section 11B-707 — AUTOMATIC TELLER MACHINES, FARE MACHINES AND…
- Section 11B-708 — TWO-WAY COMMUNICATION SYSTEMS
- Section 11B-801 — GENERAL
- Section 11B-802 — WHEELCHAIR SPACES, COMPANION SEATS AND DESIG…
- Section 11B-803 — DRESSING, FITTING AND LOCKER ROOMS
- Section 11B-804 — KITCHENS, KITCHENETTES AND WET BARS
- Section 11B-805 — MEDICAL CARE AND LONG-TERM CARE FACILITIES
- Section 11B-806 — TRANSIENT LODGING GUEST ROOMS
- Section 11B-807 — HOLDING CELLS AND HOUSING CELLS
- Section 11B-808 — COURTROOMS
- Section 11B-809 — RESIDENTIAL DWELLING UNITS
- Section 11B-810 — TRANSPORTATION FACILITIES
- Section 11B-811 — STORAGE
- Section 11B-812 — ELECTRIC VEHICLE CHARGING STATIONS
- Section 11B-813 — ADULT CHANGING FACILITIES
- Section 11B-901 — GENERAL
- Section 11B-902 — DINING SURFACES AND WORK SURFACES
- Section 11B-903 — BENCHES
- Section 11B-904 — CHECK-OUT AISLES AND SALES AND SERVICE COUNT…
- Section 11B-1001 — GENERAL
- Section 11B-1002 — AMUSEMENT RIDES
- Section 11B-1003 — RECREATIONAL BOATING FACILITIES
- Section 11B-1004 — EXERCISE MACHINES AND EQUIPMENT
- Section 11B-1005 — FISHING PIERS AND PLATFORMS
- Section 11B-1006 — GOLF FACILITIES
- Section 11B-1007 — MINIATURE GOLF FACILITIES
- Section 11B-1008 — PLAY AREAS
- Section 11B-1009 — SWIMMING POOLS, WADING POOLS AND SPAS
- Section 11B-1010 — SHOOTING FACILITIES WITH FIRING POSITIONS
- Chapter 12 — INTERIOR ENVIRONMENT
- Chapter 13 — ENERGY EFFICIENCY
- Chapter 14 — EXTERIOR WALLS
- Chapter 15 — ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
- Chapter 16 — STRUCTURAL DESIGN
- Chapter 16A — STRUCTURAL DESIGN
- Chapter 17 — SPECIAL INSPECTIONS AND TESTS
- Chapter 17A — SPECIAL INSPECTIONS AND TESTS
- Chapter 18 — SOILS AND FOUNDATIONS
- Chapter 18A — SOILS AND FOUNDATIONS
- Chapter 19 — CONCRETE
- Chapter 19A — CONCRETE
- Chapter 20 — ALUMINUM
- Chapter 21 — MASONRY
- Chapter 21A — MASONRY
- Chapter 22 — STEEL
- Chapter 22A — STEEL
- Chapter 23 — WOOD
- Chapter 24 — GLASS AND GLAZING
- Chapter 25 — GYPSUM PANEL PRODUCTS AND PLASTER
- Chapter 26 — PLASTIC
- Chapter 27 — ELECTRICAL
- Chapter 28 — MECHANICAL SYSTEMS
- Chapter 29 — PLUMBING SYSTEMS
- Chapter 30 — ELEVATORS AND CONVEYING SYSTEMS
- Chapter 31 — SPECIAL CONSTRUCTION
- Chapter 31A — SYSTEMS FOR WINDOW CLEANING OR EXTERIOR BUILDING…
- Chapter 31B — PUBLIC POOLS
- Chapter 31C — RADIATION
- Chapter 31D — FOOD ESTABLISHMENTS
- Chapter 31F — MARINE OIL TERMINALS
- Chapter 32 — ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
- Chapter 33 — SAFEGUARDS DURING CONSTRUCTION
- Chapter 34 — RESERVED
- Chapter 35 — REFERENCED STANDARDS
- Appendix A — EMPLOYEE QUALIFICATIONS
- Appendix B — BOARD OF APPEALS
- Appendix C — GROUP U—AGRICULTURAL BUILDINGS
- Appendix D — FIRE DISTRICTS
- Appendix E — RESERVED
- Appendix F — RODENTPROOFING
- Appendix G — FLOOD-RESISTANT CONSTRUCTION
- Appendix H — SIGNS
- Appendix I — PATIO COVERS
- Appendix J — GRADING
- Appendix K — GROUP R-3 AND GROUP R-3.1 OCCUPANCIES PROTECTED B…
- Appendix L — EARTHQUAKE RECORDING INSTRUMENTATION
- Appendix M — TSUNAMI-GENERATED FLOOD HAZARDS
- Appendix N — REPLICABLE BUILDINGS
- Appendix O — PERFORMANCE-BASED APPLICATION
- Appendix P — SLEEPING LOFTS
- Appendix Q — EMERGENCY HOUSING