11B- 1006.1 General. Golf facilities shall comply with Section 11B- 1006 .
11B- 1006.2 Accessible routes. Accessible routes serving teeing grounds, practice teeing grounds, putting greens, practice putting greens, teeing stations at driving ranges, course weather shelters, golf car rental areas, bag drop areas and course toilet rooms shall comply with Division 4 and shall be 48 inches ( 1219 mm) wide minimum. Where handrails are provided, accessible routes shall be 60 inches ( 1524 mm) wide minimum.
Exception: Handrails shall not be required on golf courses. Where handrails are provided on golf courses, the handrails shall not be required to comply with Section 11B- 505 .
11B- 1006.3 Golf car passages. Golf car passages shall comply with Section 11B- 1006.3.
11B- 1006.3.1 Clear width. The clear width of golf car passages shall be 48 inches ( 1219 mm) minimum.
11B- 1006.3.2 Barriers. Where curbs or other constructed barriers prevent golf cars from entering a fairway, openings 60 inches ( 1524 mm) wide minimum shall be provided at intervals not to exceed 75 yards (69 m).
11B- 1006.4 Weather shelters. A clear floor or ground space 60 inches ( 1524 mm) minimum by 96 inches ( 2438 mm) minimum shall be provided within weather shelters.