Chapter 11B — ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS,
Section 11B — 306 — KNEE AND TOE CLEARANCE
2025 California Building Code (Title 24, Part 2) · 2025 edition · ingested 2026-07-07 · California
Full text via GoCodebook AI
We have the complete 2025 text of this code. Ask a question and get the exact controlling section with a citation.
11B- 306.1 General. Where space beneath an element is included as part of clear floor or ground space or turning space, the space shall comply with Section 11B- 306. Additional space shall not be prohibited beneath an element but shall not be considered as part of the clear floor or ground space or turning space. 11B- 306.2 — Toe clearance. 11B- 306.2.1 General. Space under an element between the finish floor or ground and 9 inches ( 229 mm) above the finish floor or ground shall be considered toe clearance and shall comply with Section 11B- 306.2. 11B- 306.2.2 Maximum depth. Toe clearance…