Chapter 11B — ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS,
Section 11B — 605 — URINALS
2025 California Building Code (Title 24, Part 2) · 2025 edition · ingested 2026-07-07 · California
Full text via GoCodebook AI
We have the complete 2025 text of this code. Ask a question and get the exact controlling section with a citation.
11B- 605.1 General. Urinals not provided in urinal compartments shall comply with Sections 11B-605.1 through 11B-605.4. Urinals provided in urinal compartments shall comply with Sections 11B-605.1 through 11B-605.5. 11B- 605.2 Height and depth. Urinals shall be the stall-type or the wall-hung type with the rim 17 inches ( 432 mm) maximum above the finish floor or ground. Urinals shall be 13 [1] / 2 inches ( 343 mm) deep minimum measured from the outer face of the urinal rim to the back of the fixture. FIGURE 11B- 605.2—HEIGHT AND DEPTH OF URINALS 11B- 605.3 Clear floor space. A clear floor or…