CALGreen · California Green Building Standards Code (CALGreen)
Planning & Design (Division A5.1)
Division A5.1 is the Appendix A5 chapter of voluntary planning and design measures that guides site selection, stormwater, parking/EV readiness, light‑pollution and cool‑roof strategies to reduce GHGs and support Tiered CALGreen compliance.
Last reviewed: July 6, 2026
Overview
Division A5.1 is the Planning & Design chapter of Appendix A5 (nonresidential voluntary measures) in the California Green Building Standards Code (CALGreen). It collects site- and land-use–oriented strategies — site selection, community connectivity, transit priority, parking and circulation, stormwater and grading, lighting and heat-island controls, and measures that support reuse and infill — intended to reduce greenhouse gas emissions and improve building performance at the project scale .
A5.1 links directly with Chapter 5 mandatory planning provisions (for example, reuse and deconstruction at §5.105.1–§5.105.2 and stormwater pollution-prevention at §5.106.1–§5.106.2) while also offering voluntary electives and tiered measures such as designated parking and EV readiness/charging (see §5.106.5, §5.106.5.1 and related A5 tables) and cool‑roof requirements (see §A5.106.11.2). These measures are commonly used to meet CALGreen Tier targets and local green‑building objectives .
In this section
Code references
Grounded in the retrieved California Green Building Standards Code (CALGreen) — click a citation to read the verbatim passage:
CALGreen § 5.106.5.3.6 High relevance — show source text
Table 5.106.5.3.6,
5.106.5.3.6.1,
5.106.5.3.6.2 and
5.106.5.3.6.3||||| |DIVISION 5.1
Planning and
Design|Mandatory|Additions or Alterations to existing buildings or parking facili-
ties [A] with Exceptions|5.106.5.4||||| |DIVISION 5.1
Planning and
Design|Mandatory|Existing buildings or parking areas without previously
installed EV capable infrastructure [A]|5.106.5.4.1||||| |DIVISION 5.1
Planning and
Design|Mandatory|Existing buildings or parking areas without previously
installed EV capable infrastructure [A]|5.106.5.4.2||||| |DIVISION 5.1
Planning and
Design|Mandatory|Electric vehicle (EV) charging: medium-duty and heavy-duty [N]|5.106.5.5||||| |DIVISION 5.1
Planning and
Design|Mandatory|Electric vehicle charging readiness requirements for warehouses,
grocery stores and retail stores, office buildings, and manufactur-
ing facilities with planned off-street loading spaces [N]|5.106.5.5.1||||| |DIVISION 5.1
Planning and
Design|Mandatory|Table 5.106.5.5.1|5.106.5.5 and
5.106.5.5.1||||| |DIVISION 5.1
Planning and
Design|Mandatory|Light pollution reduction [N] (with exceptions, notes and table)|5.106.8 through
5.106.8.2||||| |DIVISION 5.1
Planning and
Design|Mandatory|Grading and paving (exception for additions and alterations
not altering the drainage path)|5.106.10||||| |DIVISION 5.2
Energy
Efficiency|Mandatory|Meet the minimum energy efficiency standard|5.201.1|||||APPENDIX A5-44 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
APPENDIX A5 — NONRESIDENTIAL VOLUNTARY MEASURES
CHAPTER 5
DIVISIONSCol2 SECTION TITLE CODE
SECTIONY N/A O PLAN SHEET,
SPEC OR
ATTACHDIVISION 5.3
Water
Efficiency and
ConservationMandatory Separate meters (new buildings or additions > 50,000 sf
that consume more than 100 gal/day)5.303.1.1 **DIVISION 5. CALGreen § 101.7 High relevance — show source text
APPENDIX A5 – NONRESIDENTIAL VOLUNTARY MEASURES
DIVISION A5.1 – PLANNING AND DESIGN
(Matrix Adoption Tables are nonregulatory, intended only as an aid to the code user. See Chapter 1 for state agency authority and building applications.)
Adopting agency BSC BSC-
CGSFM HCD Col6 Col7 DSA Col9 OSHPD Col11 Col12 Col13 Col14 Col15 BSCC DPH AGR DWR CEC CA SL SLC Adopting agency BSC BSC-
CGSFM 1 2 1/AC AC SS 1 1R 2 3 4 5 5 5 5 5 5 5 5 5 Adopt entire CA chapter X Adopt entire chapter as
amended (amended
sections listed below)Adopt only those sections that
are listed belowChapter/Section 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE APPENDIX A5-1
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
APPENDIX A5-2 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
A5 NONRESIDENTIAL VOLUNTARY MEASURES
The measures contained in this appendix are not mandatory unless adopted by a city, county, or city and county as specified in Section 101.7 and provide additional measures that designers, builders and property owners may wish to consider during the planning, design and construction process.
DIVISION A5.1 – PLANNING AND DESIGN
PREFACE
Given that land use and planning are largely regulated locally, cities, counties and cities and counties should consider reducing greenhouse gas emissions associated with development through local land-use practices in conjunction with enforcing the provisions of this code. Specific land use strategies a city, county or city and county may wish to consider include but are not limited to the following:
Site selection. Develop sites for buildings, hardscape, roads or parking areas consistent with the local general plan and regional transportation plan pursuant to SB 375 (Stats. 2008, Ch. 728).
Regional sustainable communities strategy. Site selection and building design and use shall conform the project with the prevailing regional sustainable communities strategy or alternative planning strategy, whichever meets the greenhouse gas target established by the California Air Resources Board pursuant to SB375 (Stats. 2008, Ch. 728), including the general location of uses, residential densities and building intensities.
Transit priority projects. To qualify as a transit priority project, the project shall meet three criteria:
CALGreen § 106.5.5 High relevance — show source text
106.5.5||||| |
DIVISION 5.1
Planning and
Design
(continued)|Mandatory|Electric vehicle charging readiness requirements for warehouses,
grocery stores and retail stores, office buildings, and manufactur-
ing facilities with planned off-street loading spaces [N]|5.106.5.5.1|||||APPENDIX A5-48 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
APPENDIX A5 — NONRESIDENTIAL VOLUNTARY MEASURES
CHAPTER 5
DIVISIONSCol2 Col3 SECTION TITLE CODE
SECTIONY N O PLAN SHEET,
SPEC OR
ATTACH(continued)
DIVISION 5.1
Planning and
Design
Select One Elective(continued)
DIVISION 5.1
Planning and
Design
Select One ElectiveMandatory Table 5.106.5.5.1 5.106.5.5 and
5.106.5.5.1(continued)
DIVISION 5.1
Planning and
Design
Select One Elective(continued)
DIVISION 5.1
Planning and
Design
Select One ElectiveMandatory Light pollution reduction [N] (with exceptions, notes and
table)5.106.8 through
5.106.8.2(continued)
DIVISION 5.1
Planning and
Design
Select One Elective(continued)
DIVISION 5.1
Planning and
Design
Select One ElectiveMandatory Grading and paving (exception for additions and
alterations not altering the drainage path)5.106.10 (continued)
DIVISION 5.1
Planning and
Design
Select One Elective(continued)
DIVISION 5.1
Planning and
Design
Select One ElectiveTier 1
PrerequisiteCool roof (A5.106.11.2.2): SRI 75 when≤_ 2:12, SRI 16 when >_
2:12A5.106.11.2 (continued)
DIVISION 5.1
Planning and
Design
Select One ElectiveSelect One Elective Elective Community connectivity A5.103.1 (continued)
DIVISION 5.1
Planning and
Design
Select One ElectiveSelect One Elective Elective Brownfield or greyfield site redevelopment or infill area
development_A5.103. CALGreen § 8-40 High relevance — show source text
. . . . . . . . . . . . . 8-40
APPENDIX A4 RESIDENTIAL
VOLUNTARY MEASURES. . . . . . . . . . . . . . . . . APPENDIX A4-3
A4.1 Planning and Design . . . . . . . . . . . . . . . . . APPENDIX A4-3 A4.2 Energy Efficiency . . . . . . . . . . . . . . . . . . . . APPENDIX A4-9 A4.3 Water Efficiency and Conservation . . . APPENDIX A4-13 A4.4 Material Conservation and Resource Efficiency . . . . . . . . . . . . . . . . . . . . . . . . APPENDIX A4-15 A4.5 Environmental Quality . . . . . . . . . . . . . . APPENDIX A4-19 A4.6 Tier 1 and Tier 2 . . . . . . . . . . . . . . . . . . . . APPENDIX A4-21
Division A4.6—Residential Occupancies Application Checklist . . . . . . . . . . . . . APPENDIX A4-23 A4.7 Residential Model Ordinance . . . . . . . . . APPENDIX A4-31
APPENDIX A5 NONRESIDENTIAL
VOLUNTARY MEASURES. . . . . . . . . . . . . . . . . APPENDIX A5-3
A5.1 Planning and Design . . . . . . . . . . . . . . . . . APPENDIX A5-3 A5.2 Energy Efficiency . . . . . . . . . . . . . . . . . . . APPENDIX A5-13 A5.3 Water Efficiency and Conservation . . . APPENDIX A5-19 A5.4 Material Conservation and Resource Efficiency . . . . . . . . . . . . . . . . . . . . . . . . APPENDIX A5-25 A5.5 Environmental Quality . . . . . . . . . . . . . . APPENDIX A5-35 A5.6 Voluntary Tiers . . . . . . . . . . . . . . . . . . . . . APPENDIX A5-41 A5.601 CALGren Tier 1 and Tier 2. . . . . . . . . . APPENDIX A5-41
A5.602 CALGreen Verification Guidelines Mandatory Measures Checklist . . . . . . . . . . . . . . . APPENDIX A5-44
A5.602.1 CALGreen Verification Guidelines
Tier 1 Checklist . . . . . . . . . . . . . . . . . APPENDIX A5-48
A5.602.2 CALGreen Verification Guidelines
Tier 2 Checklist . . . . . . . . . . . . . . . . . APPENDIX A5-55
APPENDIX A6 VOLUNTARY STANDARDS FOR HEALTH
CALGreen § 405.4 High relevance — show source text
- From Division A5.4,
a. Comply with recycled content of 10 percent of materials based on estimated total cost, or use two products from Table A5.405.4 for at least 75 percent by cost in Section A5.405.4. b. Comply with the 65-percent reduction in construction and demolition waste in Section A5.408.3.1. c. Comply with one elective measure selected from this division.
- From Division A5.5,
a. Comply with resilient flooring systems for 90 percent of resilient flooring in Section A5.504.4.7. b. Comply with thermal insulation meeting 2009 CHPS low-emitting materials list in Section A5.504.4.8. c. Comply with one elective measure selected from this division. 6. Comply with one additional elective measure selected from any division.
1 Cool roof is required for compliance with Tiers 1 and 2 and may be used to meet energy standards in Part 6, exceed energy standards and to mitigate heat island effect.
A5.601.3 CALGreen Tier 2.
A5.601.3.1 Prerequisites. To achieve CALGreen tier status, a project must meet all of the mandatory measures in Chapter 5 and, in addition, meet the provisions of this section.
A5.601.3.2 Energy performance. For the purposes of mandatory energy efficiency standards in this code, the California Energy Commission will continue to adopt mandatory standards.
A5.601.3.3 Tier 2. Comply with the energy efficiency requirements in Section A5.203.1.1 and Section A5.203.1.2.2.
A5.601.3.4 Voluntary measures for Tier 2. In addition to the provisions of Sections A5.601.3.1 and A5.601.3.3 above, compliance with the following voluntary measures from Appendix A5 is required for Tier 2:
- From Division A5.1, a. Comply with the designated parking requirements for fuel efficient vehicles for a minimum of 50 percent of parking capacity per Section A5.106.5.1. b. Electric vehicle (EV) charging [N] and Table A5.106.5.3.2 with footnotes. c. Comply with thermal emittance, solar reflectance or SRI values for cool roofs in Section A5.106.11.2 and Table A5.106.11.2.3. [1]
d. Comply with three elective measures selected from this division.
APPENDIX A5-42 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
APPENDIX A5 — NONRESIDENTIAL VOLUNTARY MEASURES
From Division A5.2 comply with TWO of the following:
Outdoor lighting as described in A5.203.1.1.1.
Service water heating in restaurants as described in A5.203.1.1.2.
Warehouse Dock Seal Doors A5.203.1.1.3.
Daylight Design Power Adjustments 5.203.1.1.4.
Exhaust Air Heat Recovery A5.203.1.1.5.
From Division A5.3,
CALGreen § 5.508.2 High relevance — show source text
000 square feet or more|5.508.2
through
5.508.2.6.3||||| |||END OF MANDATORY PROVISIONS||||||Documentation Author's / Responsible Designer's Declaration Statement
□ Mandatory: I attest that this mandatory provisions checklist is accurate and complete.Col2 Signature: Signature: Company: Date: Address: License: City/State/Zip: Phone: 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE APPENDIX A5-47
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
APPENDIX A5 — NONRESIDENTIAL VOLUNTARY MEASURES
A5.602.1
CALGreen VERIFICATION GUIDELINES
TIER 1 CHECKLIST
Application: This checklist shall be used for nonresidential projects that meet the following: new construction, or building additions of 1,000 square feet or greater, or building alterations with a permit valuation of $200,000 or more pursuant to Section 301.3, AND are adopting Tier 1 voluntary measures.
Note: All applicable mandatory requirements in Chapter 5 shall be met prior to applying Tier 1 voluntary measures.
Instructions:
Comply with all Tier 1 prerequisite measures from the various categories shown on the table below.
Add a “ Y ” to all mandatory and Tier 1 prerequisite measures in the appropriate columns.
Select the required number of additional electives from those categories shown on the table below and add a “ Y ” on the selected elective and add an “ N ” on the rest.
Count the total number of Tier 1 prerequisite measures plus the additional electives and write down the total number at the end of the checklist. Determine if the required number of Tier 1 measures have been selected to achieve Tier 1 compliance.
Y = Yes (section has been selected and/or included) N = No (section has not been selected and/or included) O = Other (provide explanation)
[N] = New construction pursuant to Section 301.3
[A] = Additions and/or Alterations pursuant to Section 301.3
CHAPTER 5
DIVISIONSCol2 SECTION TITLE CODE
SECTIONY N O PLAN SHEET,
SPEC OR
ATTACHDIVISION 5.1
Planning and
Design
(continued)Mandatory Deconstruction and reuse of existing structures,
Scope with Exception5.105.1 DIVISION 5.1
Planning and
Design
(continued)Mandatory Reuse of existing building & Verification of compliance with note 5.105.2 and 5.105.2.1 DIVISION 5.1
Planning and
Design
(continued)Mandatory Storm water pollution prevention for projects that disturb
less than 1 acre of land5.106.1 through
5.106.2DIVISION 5.1
Planning and
Design
(continued)Mandatory Short-term bicycle parking 5.106.4.1. CALGreen § 602.1 High relevance — show source text
2025 CALIFORNIA GREEN BUILDING STANDARDS CODE APPENDIX A5-39
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
APPENDIX A5-40 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
A5 NONRESIDENTIAL VOLUNTARY MEASURES
DIVISION A5.6 – VOLUNTARY TIERS
SECTION A5.601—CALGreen TIER 1 AND TIER 2 Col2 Col3 Col4 TABLE A5.601 NONRESIDENTIAL BUILDINGS: Green Building Standards Code Proposed Performance Approach
Note: This table is intended only as an aid in illustrating the nonresidential tier structure (Refer to Checklists A5.602, A5.602.1 and A5.602.2 for
CALGreen verification guidelines for Mandatory Checklist, Tier 1 Checklist and Tier 2 Checklist.)TABLE A5.601 NONRESIDENTIAL BUILDINGS: Green Building Standards Code Proposed Performance Approach
Note: This table is intended only as an aid in illustrating the nonresidential tier structure (Refer to Checklists A5.602, A5.602.1 and A5.602.2 for
CALGreen verification guidelines for Mandatory Checklist, Tier 1 Checklist and Tier 2 Checklist.)TABLE A5.601 NONRESIDENTIAL BUILDINGS: Green Building Standards Code Proposed Performance Approach
Note: This table is intended only as an aid in illustrating the nonresidential tier structure (Refer to Checklists A5.602, A5.602.1 and A5.602.2 for
CALGreen verification guidelines for Mandatory Checklist, Tier 1 Checklist and Tier 2 Checklist.)TABLE A5.601 NONRESIDENTIAL BUILDINGS: Green Building Standards Code Proposed Performance Approach
Note: This table is intended only as an aid in illustrating the nonresidential tier structure (Refer to Checklists A5.602, A5.602.1 and A5.602.2 for
CALGreen verification guidelines for Mandatory Checklist, Tier 1 Checklist and Tier 2 Checklist.)CATEGORY ENVIRONMENTAL
PERFORMANCE GOALTIER 1 TIER 2 All Minimum Mandatory
(See Mandatory Checklist)Meet all of the provisions
of Chapter 5 (See Tier 1 Checklist)Meet all of the provisions
of Chapter 5 (See Tier 2 Checklist)DIVISION 5.1
Planning and DesignReuse of existing building See Section A5.105.1 and Section
A5.105.2 requirementsSee Section A5.105.1 and Section
A5.105.2 requirementsDIVISION 5.1
Planning and DesignDesignated Parking for
Fuel Efficient Vehicles
(Tier 1 and Tier 2 only)Approx. 35% of total spaces Approx. 50% of total spaces DIVISION 5.1
Planning and DesignElectric Vehicle Charging Approx. 30% of total spaces Approx. 45% of total spaces **DIVISION 5. CALGreen § 106.9 High relevance — show source text
FEATURE OR MEASURE COMPLIANCE LEVELS Col3 Col4 NOTES FEATURE OR MEASURE Mandatory
CALGreenVOLUNTARY
CALGreenVOLUNTARY
CALGreenVOLUNTARY
CALGreenFEATURE OR MEASURE Mandatory
CALGreenTier 1 Tier 2 Tier 2 DIVISION A6.1 – PLANNING AND DESIGN SECTION Site Development SECTION Site Development SECTION Site Development SECTION Site Development SECTION Site Development **A6.106.9 Building orientation.**Locate and orient the building as follows:
1. When site and location permit, orient the building with the long sides facing north and
south.
2. Protect the building from thermal loss, drafts and degradation of the building envelope
caused by wind and wind-driven materials such as dust. DIVISION A6.2 – ENERGY EFFICIENCY SECTION A6.203 Performance Measures SECTION A6.203 Performance Measures SECTION A6.203 Performance Measures SECTION A6.203 Performance Measures SECTION A6.203 Performance Measures A6.203.1 Energy performance. [OSHPD 1]
**A6.203.1.1 CALGreen Tier 1. [OSHPD 1]**Buildings must comply with the latest edition of
“Savings By Design, Healthcare Modeling Procedures.”
A.5.203.1.2 CALGreen Tier 2. [OSHPD 1] Buildings must exceed the latest edition of “Savings
By Design, Healthcare Modeling Procedures” by 15 percent. SECTION A6.204 Prescriptive Measures **A6.204.1 ENERGY STAR equipment and appliances.**All equipment and appliances provided
by the builder shall be ENERGY STAR labeled if ENERGY STAR is applicable to that equipment
or appliance. A6.204.4 Commissioning. Building commissioning for all building systems covered by T24,
Part 6, process systems and renewable energy systems shall be included in the design and
construction processes of the building project. Commissioning requirements shall include as
a minimum items listed in Section A6.204.4.
**A6.204.4.1 Owner’s Project Requirements (OPR).**Documented before the design phase of
the project begins the OPR shall include items listed in Section A6.204.4.
**A6.204.4.2 Basis of Design (BOD).**A written explanation of how the design of the building
systems meets the OPR shall be completed at the design phase of the building project and
updated periodically to cover the systems listed in Section A6.204.4.2.
**A6.204.4.3 Commissioning plan.CALGreen § 106.5.3.2.1 High relevance — show source text
_
5.106.5.3.2.1,
5.106.5.3.2.2,
5.106.5.3.2.3,
5.106.5.3.2.4,
5.106.5.3.3, 5.106.5.3.4
and 5.106.5.3.5
OR
A5.106.5.3.4,
Table A5.106.5.3.4 Tier
2, 5.106.5.3.3,
5.106.5.3.4, 5.106.5.3.5,
5.106.5.3.6,
5.106.5.3.6.1,
5.106.5.3.2 and
5.106.5.3.6.3||||| |DIVISION 5.1
Planning and
Design
(continued)|Mandatory|Additions or Alterations to existing buildings or parking
facilities [A] with Exceptions|5.106.5.4||||| |DIVISION 5.1
Planning and
Design
(continued)|Mandatory|Existing buildings or parking areas without previously
installed EV capable infrastructure [A].|5.106.5.4.1||||| |DIVISION 5.1
Planning and
Design
(continued)|Mandatory|Existing buildings or parking areas with previously
installed EV capable infrastructure [A].|5.106.5.4.2|||||2025 CALIFORNIA GREEN BUILDING STANDARDS CODE APPENDIX A5-55
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
APPENDIX A5 — NONRESIDENTIAL VOLUNTARY MEASURES
CHAPTER 5
DIVISIONSCol2 Col3 SECTION TITLE CODE
SECTIONY N O PLAN SHEET,
SPEC OR
ATTACH(continued)
DIVISION 5.1
Planning and Design
Select Three Electives(continued)
DIVISION 5.1
Planning and Design
Select Three ElectivesMandatory Electric vehicle (EV) charging: medium-duty and heavy-
duty [N]5.106.5.5 (continued)
DIVISION 5.1
Planning and Design
Select Three Electives(continued)
DIVISION 5.1
Planning and Design
Select Three ElectivesMandatory Electric vehicle charging readiness requirements for ware-
houses, grocery stores and retail stores, office buildings, and
manufacturing facilities with planned off-street loading
spaces [N]5.106.5.5.1 (continued)
DIVISION 5.1
Planning and Design
Select Three Electives(continued)
**DIVISION 5.CALGreen § 5.3.3 High relevance — show source text
5.3.3,_
5.106.5.3.4 and
5.106.5.3.5
OR
A5.106.5.3.2,
Table A5.106.5.3.2
Tier 1, 5.106.5.3.3,
5.106.5.3.4,
5.106.5.3.5, 5.106.5.6,
5.106.5.3.6.1,
5.106.5.3.6.2 and
5.106.5.3.6.3||||| |DIVISION 5.1
Planning and
Design
(continued)|Mandatory|Additions or Alterations to existing buildings or parking facili-
ties [A] with Exceptions|5.106.5.4||||| |DIVISION 5.1
Planning and
Design
(continued)|Mandatory|Existing buildings or parking areas without previously
installed EV capable infrastructure [A].|5.106.5.4.1||||| |DIVISION 5.1
Planning and
Design
(continued)|Mandatory|Existing buildings or parking areas with previously installed
EV capable infrastructure [A].|5.106.5.4.2||||| |DIVISION 5.1
Planning and
Design
(continued)|Mandatory|Electric vehicle (EV) charging: medium-duty and heavy-duty [N]|5.106.5.5||||| |DIVISION 5.1
Planning and
Design
(continued)|Mandatory|Electric vehicle charging readiness requirements for warehouses,
grocery stores and retail stores, office buildings, and manufactur-
ing facilities with planned off-street loading spaces [N]|5.106.5.5.1|||||APPENDIX A5-48 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
APPENDIX A5 — NONRESIDENTIAL VOLUNTARY MEASURES
CHAPTER 5
DIVISIONSCol2 Col3 SECTION TITLE CODE
SECTIONY N O PLAN SHEET,
SPEC OR
ATTACH(continued)
DIVISION 5.1
Planning and
Design
Select One Elective(continued)
DIVISION 5.1
Planning and
Design
Select One ElectiveMandatory Table 5.106.5.5.1 5.106.5.5 and
5.106.5.5.1(continued)
DIVISION 5.1
Planning and
Design
Select One Elective(continued)
**DIVISION 5.CALGreen § 602.1 Medium relevance — show source text
VOLUNTARY MEASURES. . . . . . . . . . . . . . . . . APPENDIX A5-3
A5.1 Planning and Design . . . . . . . . . . . . . . . . . APPENDIX A5-3 A5.2 Energy Efficiency . . . . . . . . . . . . . . . . . . . APPENDIX A5-13 A5.3 Water Efficiency and Conservation . . . APPENDIX A5-19 A5.4 Material Conservation and Resource Efficiency . . . . . . . . . . . . . . . . . . . . . . . . APPENDIX A5-25 A5.5 Environmental Quality . . . . . . . . . . . . . . APPENDIX A5-35 A5.6 Voluntary Tiers . . . . . . . . . . . . . . . . . . . . . APPENDIX A5-41 A5.601 CALGren Tier 1 and Tier 2. . . . . . . . . . APPENDIX A5-41
A5.602 CALGreen Verification Guidelines Mandatory Measures Checklist . . . . . . . . . . . . . . . APPENDIX A5-44
A5.602.1 CALGreen Verification Guidelines
Tier 1 Checklist . . . . . . . . . . . . . . . . . APPENDIX A5-48
A5.602.2 CALGreen Verification Guidelines
Tier 2 Checklist . . . . . . . . . . . . . . . . . APPENDIX A5-55
APPENDIX A6 VOLUNTARY STANDARDS FOR HEALTH
FACILITIES [OSHPD 1, 2 & 4] . . . . . . . . . . . APPENDIX A6.1-3 A6.1 Site Planning and Design . . . . . . . . . . . APPENDIX A6.1-3 A6.2 Energy Efficiency . . . . . . . . . . . . . . . . . . APPENDIX A6.1-3 A6.4 Material Conservation and Resource Efficiency . . . . . . . . . . . . . APPENDIX A6.1-32 A6.5 Environmental Quality . . . . . . . . . . . . APPENDIX A6.1-33
INDEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INDEX-1
HISTORY NOTE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HIST-1
2025 CALIFORNIA GREEN BUILDING STANDARDS CODE vii
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
viii 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
CALIFORNIA GREEN BUILDING STANDARDS CODE – MATRIX ADOPTION TABLE
CHAPTER 1 – ADMINISTRATION
(Matrix Adoption Tables are nonregulatory, intended only as an aid to the code user. See Chapter 1 for state agency authority and building applications.)
|Adopting
CALGreen § 602.2 Medium relevance — show source text
Documentation Author's / Responsible Designer's Declaration Statement
Check the appropriate box(es) for the list below.
□ Mandatory: I attest that the mandatory provisions checklist is accurate and complete.
□ Tier 1 compliant: I attest that the total number of voluntary measures selected meet or exceed the total number required
to achieve Tier 1 compliance.
□ Partial Tier 1 compliant: I attest that the total number of voluntary measures selected do not meet the total number
required to achieve Tier 1 compliance: however, partial Tier 1 compliance has been achieved.Col2 Signature: Company: Date: Address: License: City/State/Zip: Phone: APPENDIX A5-54 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
APPENDIX A5 — NONRESIDENTIAL VOLUNTARY MEASURES
A5.602.2
CALGreen VERIFICATION GUIDELINES
TIER 2 CHECKLIST
Application: This checklist shall be used for nonresidential projects that meet the following: new construction, or building additions of 1,000 square feet or greater, or building alterations with a permit valuation of $200,000 or more pursuant to Section 301.3, AND are adopting Tier 2 voluntary measures.
Note: All applicable mandatory requirements in Chapter 5 shall be met prior to applying Tier 2 voluntary measures.
Instructions:
Comply with all Tier 2 prerequisite measures from the various categories shown on the table below.
Add a “ Y ” to all mandatory and Tier 2 prerequisite measures in the appropriate columns.
Select the required number of additional electives from those categories shown on the table below and add a “ Y ” on the selected elective and add an “ N ” on the rest.
Count the total number of Tier 2 prerequisite measures plus the additional electives and write down the total number at the end of the checklist. Determine if the required number of Tier 2 measures have been selected to achieve Tier 2 compliance.
Y = Yes (section has been selected and/or included) N = No (section has not been selected and/or included) O = Other (provide explanation)
[N] = New construction pursuant to Section 301.3
[A] = Additions and/or Alterations pursuant to Section 301.3
CHAPTER 5
DIVISIONSCol2 SECTION TITLE CODE
SECTIONY N O PLAN SHEET,
SPEC OR
ATTACHDIVISION 5.1
Planning and
Design
(continued)Mandatory Deconstruction and reuse of existing structures,
Scope with Exception5.105.1 DIVISION 5.1
Planning and
Design
(continued)Mandatory Reuse of existing building & Verification of compliance with
note5.105.2 and 5.105.2.1 DIVISION 5.1
Planning and
Design
(continued)Mandatory Storm water pollution prevention for projects that disturb
less than 1 acre of land5.106.1 through
5.106.
Frequently asked questions
Is Division A5.1 mandatory?
No. Division A5.1 contains voluntary, nonresidential measures in Appendix A5 that are not mandatory statewide unless a local jurisdiction chooses to adopt them; however, some related Chapter 5 provisions remain mandatory for applicable projects (see Appendix preface and Chapter 5 checklists) .
Where do I find the EV parking and charging requirements referenced in A5.1?
Look to the Chapter 5 planning sections §5.106.5 and its subparts for the mandatory/utility sections and to the Appendix A5 tables and elective language (A5.106.x series and Tables A5.106.5.3.x) for voluntary readiness, percentage targets and tiered options .
How does A5.1 feed into Tier 1 / Tier 2 CALGreen compliance?
Tier checklists require meeting selected A5.1 measures as prerequisites and electives (for example, designated parking percentages for fuel-efficient vehicles, EV charging readiness/charging and cool‑roof SRI targets are specified as Tier prerequisites or electives), so choosing A5.1 measures is a common path to achieve Tier 1 or Tier 2 status .
More in California Green Building Standards Code (CALGreen)
- Administration (Chapter 1)
- Nonresidential Voluntary Measures (Appendix A5 — divisions A5.1–A5.6, electives & verification)
- Residential Mandatory Measures — Planning & Design; Energy; Water; Materials; Environmental Quality (Chapter 4)
- Definitions (Chapter 2)
- Voluntary Standards for Health Facilities (Appendix A6 / OSHPD guidance)
- Green Building – scope, mixed occupancies, phased projects (Chapter 3)
- Residential Voluntary Measures (Appendix A4 — divisions A4.1–A4.6, tiers & model ordinance)
- Nonresidential Mandatory Measures — Planning & Design; Energy; Water; Materials; Environmental Quality (Chapter 5)
- Compliance verification, construction documents & checklists (Section 102, Chapter 7, Appendix checklists)
- Referenced Organizations and Standards (Chapter 6)
- Voluntary Tiers and CALGreen Tier 1 / Tier 2 (performance tiers, thresholds)
- Installer and Special Inspector Qualifications (Chapter 7)
Ask about the CALGreen
Get cited, plain-English answers on the California Green Building Standards Code (CALGreen) for your project — any code section, any scenario.
Start Free TrialRelated in the CALGreen
Energy Efficiency & Electives (Division A5.2)
Water Efficiency & Material Conservation (Divisions A5.3–A5.4)
Environmental Quality, Voluntary Tiers & Verification (Divisions A5.5–A5.6)
Nonresidential Voluntary Measures (Appendix A5 — divisions A5.1–A5.6, electives & verification)
California Green Building Standards Code (CALGreen)