CALGreen · California Green Building Standards Code (CALGreen)
Energy Efficiency & Electives (Division A5.2)
Division A5.2 compiles voluntary energy-performance options and selectable elective measures (lighting, HVAC controls, renewables, etc.) that projects can use to exceed baseline energy requirements or meet CALGreen Tier criteria.
Last reviewed: July 6, 2026
Overview
Division A5.2 of Appendix A5 collects voluntary energy-efficiency measures and elective options for nonresidential projects — from targeted prescriptive items (outdoor lighting, daylighting power adjustments, service water heating for restaurants, warehouse dock seals, exhaust-air heat recovery) to program-level energy budgets and on-site renewables and green power options. Key provisions include the energy-performance electives in §A5.203.1.1 and the energy-budget options in §A5.203.1.2, which set alternatives to Part 6 compliance for voluntary tiers and enhanced performance.
The division also lists specific elective measures — for example, on-site renewable energy (§A5.211.1), green power (§A5.211.3), controls that reduce energy (§A5.212.1.4), and elevator/escalator energy measures — that can be selected to meet Tier 1 and Tier 2 voluntary requirements. Project teams use these electives to achieve enhanced CALGreen tier status or to exceed mandatory energy standards while documenting chosen measures for verification.
In this section
Code references
Grounded in the retrieved California Green Building Standards Code (CALGreen) — click a citation to read the verbatim passage:
CALGreen § 405.4 High relevance — show source text
- From Division A5.4,
a. Comply with recycled content of 10 percent of materials based on estimated total cost, or use two products from Table A5.405.4 for at least 75 percent by cost in Section A5.405.4. b. Comply with the 65-percent reduction in construction and demolition waste in Section A5.408.3.1. c. Comply with one elective measure selected from this division.
- From Division A5.5,
a. Comply with resilient flooring systems for 90 percent of resilient flooring in Section A5.504.4.7. b. Comply with thermal insulation meeting 2009 CHPS low-emitting materials list in Section A5.504.4.8. c. Comply with one elective measure selected from this division. 6. Comply with one additional elective measure selected from any division.
1 Cool roof is required for compliance with Tiers 1 and 2 and may be used to meet energy standards in Part 6, exceed energy standards and to mitigate heat island effect.
A5.601.3 CALGreen Tier 2.
A5.601.3.1 Prerequisites. To achieve CALGreen tier status, a project must meet all of the mandatory measures in Chapter 5 and, in addition, meet the provisions of this section.
A5.601.3.2 Energy performance. For the purposes of mandatory energy efficiency standards in this code, the California Energy Commission will continue to adopt mandatory standards.
A5.601.3.3 Tier 2. Comply with the energy efficiency requirements in Section A5.203.1.1 and Section A5.203.1.2.2.
A5.601.3.4 Voluntary measures for Tier 2. In addition to the provisions of Sections A5.601.3.1 and A5.601.3.3 above, compliance with the following voluntary measures from Appendix A5 is required for Tier 2:
- From Division A5.1, a. Comply with the designated parking requirements for fuel efficient vehicles for a minimum of 50 percent of parking capacity per Section A5.106.5.1. b. Electric vehicle (EV) charging [N] and Table A5.106.5.3.2 with footnotes. c. Comply with thermal emittance, solar reflectance or SRI values for cool roofs in Section A5.106.11.2 and Table A5.106.11.2.3. [1]
d. Comply with three elective measures selected from this division.
APPENDIX A5-42 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
APPENDIX A5 — NONRESIDENTIAL VOLUNTARY MEASURES
From Division A5.2 comply with TWO of the following:
Outdoor lighting as described in A5.203.1.1.1.
Service water heating in restaurants as described in A5.203.1.1.2.
Warehouse Dock Seal Doors A5.203.1.1.3.
Daylight Design Power Adjustments 5.203.1.1.4.
Exhaust Air Heat Recovery A5.203.1.1.5.
From Division A5.3,
CALGreen § 409.4 High relevance — show source text
Solar access is the ratio of solar insolation including shade to the
solar insolation without shade. Shading from obstructions located on the roof or any other part of the building shall not be included in the determination of annual solar access.
3.
Life cycle assessment compliant with Section A5.409.4 in this code may be substituted for prescriptive measures from Division A5.4.|A5.601.1 Scope. The measures contained in this appendix are not mandatory unless adopted by local government as specified in Section 101.7. The provisions of this section outline means of achieving enhanced construction or reach levels by incorporating addi
2025 CALIFORNIA GREEN BUILDING STANDARDS CODE APPENDIX A5-41
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
APPENDIX A5 — NONRESIDENTIAL VOLUNTARY MEASURES
tional green building measures for newly constructed nonresidential buildings as well as additions and alterations. In order to meet one of the tier levels designers, builders or property owners are required to incorporate additional green building measures necessary to meet the threshold of each level. Refer to the provisions in Section 301.3 for nonresidential additions and alterations scope and application.
A5.601.2 CALGreen Tier 1
A5.601.2.1 Prerequisites. To achieve CALGreen tier status, a project must meet all of the mandatory measures in Chapter 5 and, in addition, meet the provisions of this section.
A5.601.2.2 Energy performance. For the purposes of mandatory energy efficiency standards in this code, the California Energy Commission will continue to adopt mandatory standards.
A5.601.2.3 Tier 1. Comply with the energy efficiency requirements in Section A5.203.1.1 and Section A5.203.1.2.1.
A5.601.2.4 Voluntary measures for Tier 1. In addition to the provisions of Sections A5.601.2.1 and A5.601.2.3 above, compliance with the following voluntary measures from Appendix A5 is required for Tier 1:
- From Division A5.1, a. Comply with the designated parking requirements for high-efficiency vehicles for a minimum of 35 percent of parking capacity per Section A5.106.5.1. b. Electric vehicle (EV) charging [N] and Table A5.106.5.3.1 w/ footnotes. c. Comply with thermal emittance, solar reflectance or SRI values for cool roofs in Section A5.106.11.2 and Table A5.106.11.2.2. [1]
d. Comply with one elective measure selected from this division. 2. From Division A5.2 comply with ONE of the following:
Outdoor lighting as described in A5.203.1.1.1.
Service water heating in restaurants as described in A5.203.1.1.2.
Warehouse Dock Seal Doors A5.203.1.1.3.
Daylight Design Power Adjustments 5.203.1.1.4.
Exhaust Air Heat Recovery A5.203.1.1.5.
From Division A5.3,
a. Comply with the 12-percent reduction for indoor potable water use in Section A5.303.2.3.1. b. Comply with one elective measure selected from this division.
- From Division A5.4,
CALGreen § 106.11 High relevance — show source text
Cool roof with Exceptions,_
Solar reflectance, Thermal emittance, Solar reflectance
index alternative, Verification of compliance|A5.106.11,
A5.106.11.2,
A5.106.11.2.1,
A5.106.11.2.2,
A5.106.11.2.3,
A5.106.11.2.4||||| |(continued)
DIVISION 5.1
Planning and Design
Select Three Electives|Select Three Electives|Elective|Reduction of heat island effect, Shade trees|A5.106.11,
A5.106.11.3||||| |(continued)
DIVISION 5.1
Planning and Design
Select Three Electives|Select Three Electives|Elective|Bird-friendly building design, Required elevation treatment,
Special conditions, Nighttime conditions with Exception,
Systems or operation and maintenance manual|A5.107, A5.107.1,
A5.107.2, A5.107.3,
A5.107.3.1||||| |DIVISION 5.2
Energy
Efficiency
(continued)|DIVISION 5.2
Energy
Efficiency
(continued)|Mandatory|Meet the minimum energy efficiency standard|5.201.1||||| |DIVISION 5.2
Energy
Efficiency
(continued)|DIVISION 5.2
Energy
Efficiency
(continued)|Tier 2
Prerequisite|Energy Performance—outdoor lighting power 90% of Part 6|A5.203.1.1.1||||| |DIVISION 5.2
Energy
Efficiency
(continued)|DIVISION 5.2
Energy
Efficiency
(continued)|Tier 2
Prerequisite|If applicable, service for water heating in restaurants of 8,000
sf or greater|A5.203.1.1.2|||||APPENDIX A5-56 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
APPENDIX A5 — NONRESIDENTIAL VOLUNTARY MEASURES
CHAPTER 5
DIVISIONSCol2 Col3 SECTION TITLE CODE
SECTIONY N O PLAN SHEET,
SPEC OR
ATTACH(continued)
DIVISION 5.2
Energy
Efficiency(continued)
DIVISION 5.2
Energy
EfficiencyTier 2
PrerequisiteEnergy budget 90% or 85% of Part 6 calculated value of
allowance_A5.203.1.2. CALGreen § 5.2 High relevance — show source text
2**
Energy
Efficiency|(continued)
DIVISION 5.2
Energy
Efficiency|Elective|On-site renewable energy (with documentation)|A5.211.1,
A5.211.1.1||||| |(continued)
DIVISION 5.2
Energy
Efficiency|(continued)
DIVISION 5.2
Energy
Efficiency|Elective|Green power|A5.211.3||||| |(continued)
DIVISION 5.2
Energy
Efficiency|(continued)
DIVISION 5.2
Energy
Efficiency|Elective|Elevators with car lights and fan|A5.212.1.1,
A5.212.1.1.1||||| |(continued)
DIVISION 5.2
Energy
Efficiency|(continued)
DIVISION 5.2
Energy
Efficiency|Elective|Escalators|A5.212.1.2||||| |(continued)
DIVISION 5.2
Energy
Efficiency|(continued)
DIVISION 5.2
Energy
Efficiency|Elective|Controls that reduce energy|A5.212.1.4||||| |(continued)
DIVISION 5.2
Energy
Efficiency|(continued)
DIVISION 5.2
Energy
Efficiency|Elective|Steel framing|A5.213.1||||| |DIVISION 5.3
Water
Efficiency and
Conservation
Select Three Electives|DIVISION 5.3
Water
Efficiency and
Conservation
Select Three Electives|Mandatory|Separate meters (new buildings or additions > 50,000 sf
that consume more than 100 gal/day)|5.303.1.1||||| |DIVISION 5.3
Water
Efficiency and
Conservation
Select Three Electives|DIVISION 5.3
Water
Efficiency and
Conservation
Select Three Electives|Mandatory|Separate meters (for tenants in new buildings or additions
that consume more than 1,000 gal/day)|5.303.1.2||||| |DIVISION 5.3
Water
Efficiency and
Conservation
Select Three Electives|**DIVISION 5.CALGreen § 5.2 Medium relevance — show source text
1**
Planning and Design||1 additional Elective from Division A5.1|3 additional Electives from Division A5.1| |DIVISION 5.2
Energy Efficiency|Energy Performance2a, 2b|Outdoor lighting power 90%
of Part 6 allowance|Outdoor lighting power 90%
of Part 6 allowance| |||If applicable, solar water-heating system
with minimum solar savings fraction of 0.15|If applicable, solar water-heating system
with minimum solar savings fraction of 0.15| |||Warehouse door seals|Warehouse door seals| |||Comply with day lighting requirements|Comply with day lighting requirements| |||Exhaust heat recovery|Exhaust heat recovery| |||Energy Budget 95% or 90%
of Part 6 calculated value of allowance|Energy Budget 90% or 85%
of Part 6 calculated value of allowance| |DIVISION 5.3
Water Efficiency
and Conservation|Indoor Water Use|12% Savings|20% Savings| |DIVISION 5.3
Water Efficiency
and Conservation||1 additional Elective from Division A5.3|3 additional Electives from Division A5.3| |DIVISION 5.4
Material Conservation
and Resource Efficiency3|Construction Waste Reduction|At least 65% reduction|At least 80% reduction| |DIVISION 5.4
Material Conservation
and Resource Efficiency3|Recycled Content|Utilize recycled content materials for
10% of total material cost|Utilize recycled content materials for
15% of total material cost| |DIVISION 5.4
Material Conservation
and Resource Efficiency3|Cradle-to-Grave
Whole Building Life Cycle
Assessment|See Section A5.409.1, Section A5.409.2
and Section A5.409.2.3 requirements|See Section A5.409.1, Section A5.409.2
and Section A5.409.2.3 requirements| |DIVISION 5.4
Material Conservation
and Resource Efficiency3|Product GWP compliance –
prescriptive path|See Section A5.409.1, Section A5.409.2
and Section A5.409.2.3 requirements|See Section A5.409.1, Section A5.409.2
and Section A5.409.2.3 requirements| |DIVISION 5.4
Material Conservation
and Resource Efficiency3||1 additional Elective
from Division A5.4|3 additional Electives
from Division A5.4| |DIVISION 5.5
Environmental Quality|Low-VOC Resilient Flooring|90% of flooring meets VOC limits|100% of flooring meets VOC limits1| |DIVISION 5.5
Environmental Quality|Low-VOC Thermal Insulation|Comply with VOC limits|Install no-added formaldehyde
insulation and comply with VOC limits| |DIVISION 5.5
Environmental Quality||1 additional Elective from Division A5.5|3 additional Electives from Division A5.CALGreen § 601.2.4 Medium relevance — show source text
A5.601.2.4 Voluntary measures for Tier 1. In addition to the provisions of Sections A5.601.2.1 and A5.601.2.3 above, compliance with the following voluntary measures from Appendix A5 is required for Tier 1:
- From Division A5.1, a. Comply with the designated parking requirements for high-efficiency vehicles for a minimum of 35 percent of parking capacity per Section A5.106.5.1. b. Electric vehicle (EV) charging [N] and Table A5.106.5.3.1 w/ footnotes. c. Comply with thermal emittance, solar reflectance or SRI values for cool roofs in Section A5.106.11.2 and Table A5.106.11.2.2. [1]
d. Comply with one elective measure selected from this division. 2. From Division A5.2 comply with ONE of the following:
Outdoor lighting as described in A5.203.1.1.1.
Service water heating in restaurants as described in A5.203.1.1.2.
Warehouse Dock Seal Doors A5.203.1.1.3.
Daylight Design Power Adjustments 5.203.1.1.4.
Exhaust Air Heat Recovery A5.203.1.1.5.
From Division A5.3,
a. Comply with the 12-percent reduction for indoor potable water use in Section A5.303.2.3.1. b. Comply with one elective measure selected from this division.
- From Division A5.4,
a. Comply with recycled content of 10 percent of materials based on estimated total cost, or use two products from Table A5.405.4 for at least 75 percent by cost in Section A5.405.4. b. Comply with the 65-percent reduction in construction and demolition waste in Section A5.408.3.1. c. Comply with one elective measure selected from this division.
- From Division A5.5,
a. Comply with resilient flooring systems for 90 percent of resilient flooring in Section A5.504.4.7. b. Comply with thermal insulation meeting 2009 CHPS low-emitting materials list in Section A5.504.4.8. c. Comply with one elective measure selected from this division. 6. Comply with one additional elective measure selected from any division.
1 Cool roof is required for compliance with Tiers 1 and 2 and may be used to meet energy standards in Part 6, exceed energy standards and to mitigate heat island effect.
A5.601.3 CALGreen Tier 2.
A5.601.3.1 Prerequisites. To achieve CALGreen tier status, a project must meet all of the mandatory measures in Chapter 5 and, in addition, meet the provisions of this section.
A5.601.3.2 Energy performance. For the purposes of mandatory energy efficiency standards in this code, the California Energy Commission will continue to adopt mandatory standards.
A5.601.3.3 Tier 2. Comply with the energy efficiency requirements in Section A5.203.1.1 and Section A5.203.1.2.2.
CALGreen § 8-40 Medium relevance — show source text
. . . . . . . . . . . . . 8-40
APPENDIX A4 RESIDENTIAL
VOLUNTARY MEASURES. . . . . . . . . . . . . . . . . APPENDIX A4-3
A4.1 Planning and Design . . . . . . . . . . . . . . . . . APPENDIX A4-3 A4.2 Energy Efficiency . . . . . . . . . . . . . . . . . . . . APPENDIX A4-9 A4.3 Water Efficiency and Conservation . . . APPENDIX A4-13 A4.4 Material Conservation and Resource Efficiency . . . . . . . . . . . . . . . . . . . . . . . . APPENDIX A4-15 A4.5 Environmental Quality . . . . . . . . . . . . . . APPENDIX A4-19 A4.6 Tier 1 and Tier 2 . . . . . . . . . . . . . . . . . . . . APPENDIX A4-21
Division A4.6—Residential Occupancies Application Checklist . . . . . . . . . . . . . APPENDIX A4-23 A4.7 Residential Model Ordinance . . . . . . . . . APPENDIX A4-31
APPENDIX A5 NONRESIDENTIAL
VOLUNTARY MEASURES. . . . . . . . . . . . . . . . . APPENDIX A5-3
A5.1 Planning and Design . . . . . . . . . . . . . . . . . APPENDIX A5-3 A5.2 Energy Efficiency . . . . . . . . . . . . . . . . . . . APPENDIX A5-13 A5.3 Water Efficiency and Conservation . . . APPENDIX A5-19 A5.4 Material Conservation and Resource Efficiency . . . . . . . . . . . . . . . . . . . . . . . . APPENDIX A5-25 A5.5 Environmental Quality . . . . . . . . . . . . . . APPENDIX A5-35 A5.6 Voluntary Tiers . . . . . . . . . . . . . . . . . . . . . APPENDIX A5-41 A5.601 CALGren Tier 1 and Tier 2. . . . . . . . . . APPENDIX A5-41
A5.602 CALGreen Verification Guidelines Mandatory Measures Checklist . . . . . . . . . . . . . . . APPENDIX A5-44
A5.602.1 CALGreen Verification Guidelines
Tier 1 Checklist . . . . . . . . . . . . . . . . . APPENDIX A5-48
A5.602.2 CALGreen Verification Guidelines
Tier 2 Checklist . . . . . . . . . . . . . . . . . APPENDIX A5-55
APPENDIX A6 VOLUNTARY STANDARDS FOR HEALTH
CALGreen § 602.1 Medium relevance — show source text
VOLUNTARY MEASURES. . . . . . . . . . . . . . . . . APPENDIX A5-3
A5.1 Planning and Design . . . . . . . . . . . . . . . . . APPENDIX A5-3 A5.2 Energy Efficiency . . . . . . . . . . . . . . . . . . . APPENDIX A5-13 A5.3 Water Efficiency and Conservation . . . APPENDIX A5-19 A5.4 Material Conservation and Resource Efficiency . . . . . . . . . . . . . . . . . . . . . . . . APPENDIX A5-25 A5.5 Environmental Quality . . . . . . . . . . . . . . APPENDIX A5-35 A5.6 Voluntary Tiers . . . . . . . . . . . . . . . . . . . . . APPENDIX A5-41 A5.601 CALGren Tier 1 and Tier 2. . . . . . . . . . APPENDIX A5-41
A5.602 CALGreen Verification Guidelines Mandatory Measures Checklist . . . . . . . . . . . . . . . APPENDIX A5-44
A5.602.1 CALGreen Verification Guidelines
Tier 1 Checklist . . . . . . . . . . . . . . . . . APPENDIX A5-48
A5.602.2 CALGreen Verification Guidelines
Tier 2 Checklist . . . . . . . . . . . . . . . . . APPENDIX A5-55
APPENDIX A6 VOLUNTARY STANDARDS FOR HEALTH
FACILITIES [OSHPD 1, 2 & 4] . . . . . . . . . . . APPENDIX A6.1-3 A6.1 Site Planning and Design . . . . . . . . . . . APPENDIX A6.1-3 A6.2 Energy Efficiency . . . . . . . . . . . . . . . . . . APPENDIX A6.1-3 A6.4 Material Conservation and Resource Efficiency . . . . . . . . . . . . . APPENDIX A6.1-32 A6.5 Environmental Quality . . . . . . . . . . . . APPENDIX A6.1-33
INDEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INDEX-1
HISTORY NOTE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HIST-1
2025 CALIFORNIA GREEN BUILDING STANDARDS CODE vii
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
viii 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
CALIFORNIA GREEN BUILDING STANDARDS CODE – MATRIX ADOPTION TABLE
CHAPTER 1 – ADMINISTRATION
(Matrix Adoption Tables are nonregulatory, intended only as an aid to the code user. See Chapter 1 for state agency authority and building applications.)
|Adopting
CALGreen § 405.2.2 Medium relevance — show source text
4**
Material
Conservation
and Resource
Efficiency
Select Three Electives
(cont’d)|Select Three Electives
(cont’d)|Elective|Rapidly renewable materials|A5.405.2.2||||| |(continued)
DIVISION 5.4
Material
Conservation
and Resource
Efficiency
Select Three Electives
(cont’d)|Select Three Electives
(cont’d)|Elective|Reused materials (with note)|A5.405.3||||| |(continued)
DIVISION 5.4
Material
Conservation
and Resource
Efficiency
Select Three Electives
(cont’d)|Select Three Electives
(cont’d)|Elective|Cement and concrete: cement|A5.405.5.1||||| |(continued)
DIVISION 5.4
Material
Conservation
and Resource
Efficiency
Select Three Electives
(cont’d)|Select Three Electives
(cont’d)|Elective|Cement and concrete: concrete with SCM & Mix design
equation|A5.405.5.2,
A5.405.5.2.1,
A5.405.5.2.1.1|||||APPENDIX A5-58 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
APPENDIX A5 — NONRESIDENTIAL VOLUNTARY MEASURES
CHAPTER 5 DIVISIONS Col2 Col3 SECTION TITLE CODE
SECTIONY N O PLAN SHEET,
SPEC OR
ATTACH(continued)
DIVISION 5.4
Material
Conservation
and Resource
EfficiencySelect Three
(cont’d)Elective Concrete manufacture, Recycled aggregates A5.405.5.3,
A5.405.5.3.1(continued)
DIVISION 5.4
Material
Conservation
and Resource
EfficiencySelect Three
(cont’d)Elective Concrete manufacture, Mixing water A5.405.5.3,
A5.405.5.3.2(continued)
DIVISION 5.4
Material
Conservation
and Resource
EfficiencySelect Three
(cont’d)Elective Concrete manufacture, High strength concrete A5.405.5.3,
A5.405.5.3.3(continued)
**DIVISION 5.CALGreen § 212.1.4 Medium relevance — show source text
2**
Energy
Efficiency|Elective|Controls that reduce energy|A5.212.1.4||||| |(continued)
DIVISION 5.2
Energy
Efficiency|(continued)
DIVISION 5.2
Energy
Efficiency|Elective|Steel framing|A5.213.1||||| |DIVISION 5.3
Water
Efficiency and
Conservation
Select Three Electives|DIVISION 5.3
Water
Efficiency and
Conservation
Select Three Electives|Mandatory|Separate meters (new buildings or additions > 50,000 sf
that consume more than 100 gal/day)|5.303.1.1||||| |DIVISION 5.3
Water
Efficiency and
Conservation
Select Three Electives|DIVISION 5.3
Water
Efficiency and
Conservation
Select Three Electives|Mandatory|Separate meters (for tenants in new buildings or additions
that consume more than 1,000 gal/day)|5.303.1.2||||| |DIVISION 5.3
Water
Efficiency and
Conservation
Select Three Electives|DIVISION 5.3
Water
Efficiency and
Conservation
Select Three Electives|Tier 2
Prerequisite|Water reduction Tier 2—20% or 25% savings over the
“water use baseline” in Table A5.303.2.2|A5.303.2.3.2
or A5.303.2.3.3||||| |DIVISION 5.3
Water
Efficiency and
Conservation
Select Three Electives|DIVISION 5.3
Water
Efficiency and
Conservation
Select Three Electives|Mandatory|Water closets shall not exceed 1.28 gallons per flush (gpf)|5.303.3.1||||| |DIVISION 5.3
Water
Efficiency and
Conservation
Select Three Electives|DIVISION 5.3
Water
Efficiency and
Conservation
Select Three Electives|Mandatory|Wall-mounted urinals shall not exceed 0.125 gpf|5.303.3.2.1||||| |DIVISION 5.3
Water
Efficiency and
Conservation
Select Three Electives|DIVISION 5.3
Water
Efficiency and
Conservation
Select Three Electives|Mandatory|Floor-mounted urinals shall not exceed 0.CALGreen § 401.1 Medium relevance — show source text
2025 CALIFORNIA GREEN BUILDING STANDARDS CODE APPENDIX A5-23
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
APPENDIX A5-24 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
A5 NONRESIDENTIAL VOLUNTARY MEASURES
DIVISION A5.4 – MATERIAL CONSERVATION AND RESOURCE EFFICIENCY
SECTION A5.401—GENERAL
A5.401.1 Scope. The provisions of this chapter specify the requirements of achieving enhanced compliance with material conservation, resource efficiency, and greenhouse gas (GHG) emissions reduction through reuse of existing building stock and materials; use of recycled, regional, rapidly renewable and certified wood materials; and employment of techniques to reduce pollution through recycling of materials.
SECTION A5.402—DEFINITIONS
A5.402.1 Definitions. The following terms are defined in Chapter 2.
BUILDING COMMISSIONING.
BUY CLEAN CALIFORNIA ACT (BCCA).
CRADLE-TO-GRAVE.
EMBODIED ENERGY.
EUTROPHICATION.
LIFE CYCLE ASSESSMENT (LCA).
LIFE CYCLE INVENTORY (LCI).
OVE.
POSTCONSUMER CONTENT.
PRECONSUMER (or POSTINDUSTRIAL) CONTENT.
RECYCLED CONTENT.
RECYCLED CONTENT VALUE (RCV).
REFERENCE STUDY PERIOD.
TYPE III ENVIRONMENTAL PRODUCT DECLARATION (EPD).
FACTORY-SPECIFIC EPD.
INDUSTRY-WIDE EPD (IW-EPD).
PRODUCT-SPECIFIC EPD.
SECTION A5.403—FOUNDATION SYSTEMS (RESERVED)
SECTION A5.404—EFFICIENT FRAMING TECHNIQUES
A5.404.1 Wood framing. Employ advanced wood framing techniques or OVE, as recommended by the US Department of Energy’s Office of Building Technology, State and Community Programs and as permitted by the enforcing agency.
A5.404.1.1 Structural or fire-resistance integrity. The OVE selected shall not conflict with structural framing methods or firerated assemblies required by the California Building Code.
A5.404.1.2 Framing specifications. Advanced framing techniques include the following:
- Building design using 2-foot modules;
- Spacing wall studs up to 24 inches on center;
- Spacing floor and roof framing members up to 24 inches on center;
- Using 2-stud corner framing and drywall clips or scrap lumber for drywall backing;
- Eliminating solid headers in non-load-bearing walls;
- Using in-line framing, aligning floor, wall and roof framing members vertically for direct transfer of loads; and
- Using single lumber headers and top plates where appropriate.
Note: Additional information can be obtained from the US DOE Energy Efficiency and Renewable Energy (EERE) website.
SECTION A5.405—MATERIAL SOURCES
Frequently asked questions
What does “elective” mean in Division A5.2?
Electives are optional, verifiable measures a project may select from Division A5.2 to gain voluntary CALGreen credit or to satisfy the additional requirements for Tier 1 or Tier 2. Examples and section references are provided so teams can document choices such as outdoor lighting reductions, daylighting power adjustments, or on-site renewable energy.
How does A5.2 interact with the California Energy Code (Part 6)?
Division A5.2 offers voluntary paths that either reduce allowances in Part 6 (energy-budget options) or add prescriptive/technology electives that can exceed baseline Part 6 performance. See §A5.203.1.1 (outdoor lighting and other prescriptive measures) and §A5.203.1.2 (energy-budget percent targets) for the primary interactions.
Which A5.2 sections are most commonly used for Tier 1/2 compliance?
Common choices referenced in the voluntary-tier checklists include §A5.203.1.1 (outdoor lighting and other prescriptive energy measures), §A5.203.1.2 (energy budget targets for Tier performance), and electives like §A5.211.1 (on‑site renewable energy) and §A5.212.1.4 (energy‑reducing controls). These are cited in the Tier checklists in Appendix A5.
More in California Green Building Standards Code (CALGreen)
- Administration (Chapter 1)
- Nonresidential Voluntary Measures (Appendix A5 — divisions A5.1–A5.6, electives & verification)
- Residential Mandatory Measures — Planning & Design; Energy; Water; Materials; Environmental Quality (Chapter 4)
- Definitions (Chapter 2)
- Voluntary Standards for Health Facilities (Appendix A6 / OSHPD guidance)
- Green Building – scope, mixed occupancies, phased projects (Chapter 3)
- Residential Voluntary Measures (Appendix A4 — divisions A4.1–A4.6, tiers & model ordinance)
- Nonresidential Mandatory Measures — Planning & Design; Energy; Water; Materials; Environmental Quality (Chapter 5)
- Compliance verification, construction documents & checklists (Section 102, Chapter 7, Appendix checklists)
- Referenced Organizations and Standards (Chapter 6)
- Voluntary Tiers and CALGreen Tier 1 / Tier 2 (performance tiers, thresholds)
- Installer and Special Inspector Qualifications (Chapter 7)
Ask about the CALGreen
Get cited, plain-English answers on the California Green Building Standards Code (CALGreen) for your project — any code section, any scenario.
Start Free TrialRelated in the CALGreen
Planning & Design (Division A5.1)
Water Efficiency & Material Conservation (Divisions A5.3–A5.4)
Environmental Quality, Voluntary Tiers & Verification (Divisions A5.5–A5.6)
Nonresidential Voluntary Measures (Appendix A5 — divisions A5.1–A5.6, electives & verification)
California Green Building Standards Code (CALGreen)