Section 1030 of the CFC is hereby adopted in its entirety with the following exceptions, modifications, and additions.

SEC. 57.1030.6.4. DISPLAYS.

In areas used for display of equipment, booths, or similar uses, aisles shall be provided as follows:

  1. Areas containing less than 5,000 square feet of usable floor space shall be provided with 6 feet wide aisles arranged so as not to exceed the distance of travel requirements of this section.

  2. Areas containing 5,000 to 30,000 square feet of usable floor space shall be provided with 8 feet wide aisles arranged so as to not exceed the distance of travel requirements of this section.

  3. Areas containing more than 30,000 square feet of usable floor space shall be provided with 10 feet wide aisles arranged so as to not exceed the distance of travel requirements of this section.

  4. Aisles that are provided for the convenience of persons in attendance and are not required for exit purposes may be reduced below the required aisle width by 2 feet.

Exceptions & meaning →

SEC. 57.1030.13.1.3. SPACING OF TABLES.

Tables shall be arranged so that the seating edges of adjacent tables are not less than 54 inches apart. Rectangular tables arranged to accommodate seating on one side only shall have not less than 36 inches between adjacent table edges.