Skip to content

Los Angeles Municipal Code Part 3D Character Frontage

Los Angeles Municipal Code · 2026-09 edition · updated 2026-10-04 · Los Angeles

Cite as: Los Angeles Municipal Code Part 3D · Text as of 2026-10-04

RULES

Div. 3D.1. Build-To . . . . . . . . . . . . . . . . . . . . . . .3-93

Div. 3D.2. Parking . . . . . . . . . . . . . . . . . . . . . . . 3-93

Div. 3D.3. Landscaping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-93

Div. 3D.4. Ground Floor Elevation . . . . . . . . . . . . . . . . .3-93

Div. 3D.5. Story Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-94
Sec. 3D.5.1. Ground Story Height . . . . . . . . . . . . . . . . . . . .3-94
Sec. 3D.5.2. Upper Story Height . . . . . . . . . . . . . . . . . . . . 3-95

Div. 3D.6. Articulation . . . . . . . . . . . . . . . . . . . . . 3-96
Sec. 3D.6.1. Base, Middle & Top Articulation . . . . . . . . . . . . . . . .3-96
Sec. 3D.6.2. Base-Top Articulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-99
Sec. 3D.6.3. Horizontal Band Articulation . . . . . . . . . . . . . . . . . . . . . . . . .3-102
Sec. 3D.6.4. Vertical Band Articulation . . . . . . . . . . . . . . . . . . . . . . . . . . 3-103
Sec. 3D.6.5. Articulating Elements . . . . . . . . . . . . . . . . . . . 3-105

Div. 3D.7. Features . . . . . . . . . . . . . . . . . . . . . . 3-108
Sec. 3D.7.1. Restricted Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-108

Div. 3D.8. Entrances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-110
Sec. 3D.8.1. Street-Facing Entrance . . . . . . . . . . . . . . . . . . .3-110
Sec. 3D.8.2. Entry Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-111
Sec. 3D.8.3. Focal Entry Feature . . . . . . . . . . . . . . . . . . . . 3-112

Div. 3D.9. Transparency . . . . . . . . . . . . . . . . . . . . 3-116
Sec. 3D.9.1. Ground Story . . . . . . . . . . . . . . . . . . . . . . 3-116
Sec. 3D.9.2. Upper Stories . . . . . . . . . . . . . . . . . . . . . . 3-120

Div. 3D.10. Exterior Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-122
Sec. 3D.10.1. Principal Material Coverage . . . . . . . . . . . . . . . . .3-122
Sec. 3D.10.2. Accessory Material Coverage . . . . . . . . . . . . . . . . 3-124
Sec. 3D.10.3. Exterior Material Options . . . . . . . . . . . . . . . . . . . . . . . . . . .3-126

Div. 3D.11. Roof Design . . . . . . . . . . . . . . . . . . . . . 3-133
Sec. 3D.11.1. Roof Form . . . . . . . . . . . . . . . . . . . . . . . 3-133
Sec. 3D.11.2. Roof Materials . . . . . . . . . . . . . . . . . . . . . . 3-135

Article 3. Frontage | 3-92 Article Publication Update | July 23, 2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Character Frontage Rules Zoning Code Chapter 1A

Div. 3D.1. BUILD-TO

See Div. 3C.1. (Build-To). Div. 3D.2. PARKING

See Div. 3C.2. (Parking). Div. 3D.3. LANDSCAPING

See Div. 3C.3. (Landscaping). Div. 3D.4. GROUND FLOOR ELEVATION

See Sec. 3C.6.2. (Ground Floor Elevation).

Character Frontage Rules | 3-93 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.5. (Story Height) Zoning Code Chapter 1A

Div. 3D.5. STORY HEIGHT

Sec. 3D.5.1. GROUND STORY HEIGHT

For the intent, applicability, standards, measurement, and relief of ground story height see Sec. 3C.6.1. (Ground Story Height).

Sec. 3D.5.1. (Ground Story Height) | 3-94 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.5. (Story Height) Zoning Code Chapter 1A

Exceptions & meaning →

Sec. 3D.5.2. UPPER STORY HEIGHT

Upper story height is defined as the floor-to-floor height of any story of a building located above the ground story.

A. Intent

The intent of the standards of this Section (Upper Story Height) is to ensure upper story spaces and their facades are scaled and proportioned to contribute to the established architectural character of surrounding neighborhoods or districts.

B. Applicability

  1. Upper story height standards apply to new construction of multi-story buildings or structures. When upper story height standards apply, the standards apply to each story located above the ground story and all build-to applicable stories specified by the applied Frontage District (Part 3B.).

C. Standards

All occupiable space located in applicable portions of upper stories shall have a floor-to-floor

height of no less than the upper story height minimum.

D. Measurement

  1. Upper story height is measured vertically from the top of the finished floor to the top of the finished floor above.

  2. Where no story exists above an upper story, upper story height is the shortest vertical distance from the top of the finished floor to the top of the ceiling or roof structure above.

E. Exceptions

Portions of upper stories located beyond the first 15 feet of a frontage applicable facade, measured inward and perpendicular to the facade are not required to meet upper story height standards.

F. Relief

  1. A reduction in required upper story height of up to one foot may be granted in accordance with Sec. 13B.5.2. (Adjustment).

  2. Deviations from upper story height standards may be granted as a variance in accordance with Sec. 13B.5.3. (Variance).

Sec. 3D.5.2. (Upper Story Height) | 3-95 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.6. (Articulation) Zoning Code Chapter 1A

Div. 3D.6. ARTICULATION

Exceptions & meaning →

Sec. 3D.6.1. BASE, MIDDLE & TOP ARTICULATION

The base, middle & top articulation requirement is composed of three separate and coordinated articulating elements designed to visually break a building facade up into three separately legible layers.

A. Intent

The intent of the standards of this Section (Base, Middle & Top Articulation) is to visually break a
building facade up into three separately legible building layers.

B. Applicability

Base, middle & top articulation standards apply to new construction or any exterior modification
when the applied Character Frontage District (Div. 3B.9.) requires base, middle & top articulation
on facades pursuant to Sec. 3A.2.2.B.3. (Frontage Applicable Facades).

C. Standards

1. General

One articulating element option shall be provided for each building layer in accordance with
the building layer standards below.

2. Building Layers

No greater than Top base

2x base storiesMiddle (min.)

1 - 3 Base stories

Street

a. Base

i. The base building layer shall include at least one and no more than three contiguous
stories starting with the ground story and continuing upward.

Sec. 3D.6.1. (Base, Middle & Top Articulation) | 3-96 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.6. (Articulation) Zoning Code Chapter 1A

ii. At least one of the following articulating elements shall be applied along the top of the

base layer, creating a transition between the base and middle layers:

a) Sec. 3D.6.5.C.1. (Material Change);

b) Sec. 3D.6.5.C.2. (Belt Course); or

c) Sec. 3D.6.5.C.3. (Shopfront Cornice).

iii. The articulating element shall extend for the full width of the building and be located

no higher than the top of the uppermost story included in the layer.

b. Middle

i. The middle building layer shall include at least twice as many contiguous stories than the base building layer, starting at the top of the base layer and continuing upward.

ii. At least one of the following articulating elements shall be applied along the top of the
middle layer, creating a transition between the middle and top layers:

a) Sec. 3D.6.5.C.1. (Material Change);or

b) Sec. 3D.6.5.C.2. (Belt Course).

iii. The articulating element shall extend for the full width of the building and be located
no higher than the top of the uppermost story included in the layer.

c. Top

i. The top building layer shall include at least one story and shall not include more stories
than the base building layer.

ii. All stories located in the top building layer shall be contiguous and include, at
minimum, all stories between the top of the middle layer and the top of the highest of
the build-to applicable stories specified by the applied Frontage District (Part 3B.).

iii. A roofline cornice articulating element shall be applied to the top building layer when
the top building layer is the topmost story of the building or the topmost story before a
street step-back. See Sec. 3D.6.5.C.4. (Roofline Cornice).

iv. The roofline cornice shall extend for the full width of the building and be located along
the top of the topmost story included in the building layer.

v. When the top building layer does not include the topmost story of the building or
the topmost story before a street step-back, at least one of the following articulating
elements shall be applied along the top of the top layer, creating a transition between
the top building layer and any story above:

Sec. 3D.6.1. (Base, Middle & Top Articulation) | 3-97 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.6. (Articulation) Zoning Code Chapter 1A

a) Sec. 3D.6.5.C.1. (Material Change); or

b) Sec. 3D.6.5.C.2. (Belt Course).

vi. The articulating element shall extend for the full width of the building and be located

along the top of the topmost story included in the building layer.

D. Measurement

For measurement of stories see Sec. 2C.4.3. (Height in Stories).

E. Exceptions

  1. Where the applied Form District (Part 2B.) requires a street step-back depth of 10 feet or greater, the top building layer may terminate at the topmost story below the street step-back.

No articulating element is required above the top building layer.

  1. When a building is less than five stories, the standards of this Section (Base, Middle & Top Articulation) do not apply, and the standards of Sec. 3D.6.2. (Base-Top Articulation) apply.

F. Relief

  1. Base, middle & top articulation standards may be met through alternative compliance in accordance with Sec. 13B.5.1. (Alternative Compliance).

  2. A deviation from number of stories in building layers of one story may be granted in accordance with Sec. 13B.5.2. (Adjustment).

  3. Deviation from any base, middle & top articulation standard may be granted as a variance in accordance with Sec. 13B.5.3. (Variance).

Sec. 3D.6.1. (Base, Middle & Top Articulation) | 3-98 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.6. (Articulation) Zoning Code Chapter 1A

Exceptions & meaning →

Sec. 3D.6.2. BASE-TOP ARTICULATION

The base-top articulation requirement is composed of two separate and coordinated articulating elements designed to visually break a building facade up into two separately legible layers.

A. Intent

The intent of the standards of this Section (Base-Top Articulation) is to visually break a building
facade up into two separately legible building layers.

B. Applicability

Base-top articulation standards apply to new construction and any exterior modification of a
building or structure possessing five stories or fewer when the applied Character Frontage District
(Div. 3B.9.) requires base-top articulation on all facades pursuant to Sec. 3A.2.2.B.3. (Frontage
Applicable Facades).

C. Standards

1. General

One articulating element option shall be provided for each building layer in accordance with
the building layer standards below. See Sec. 3D.6.5. (Articulating Elements).

2. Building Layers

2x base stories Top (min.)

1 - 3 Base stories

Street

Sec. 3D.6.2. (Base-Top Articulation) | 3-99 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.6. (Articulation) Zoning Code Chapter 1A

a. Base

i. The base building layer shall include between one and three contiguous stories

starting with the ground story and continuing upward.

ii. At least one of the following articulating elements shall be applied along the top of the

base layer, creating a transition between the base and top layers:

a) Sec. 3D.6.5.C.1. (Material Change);

b) Sec. 3D.6.5.C.2. (Belt Course); or

c) Sec. 3D.6.5.C.3. (Shopfront Cornice).

iii. The articulating element shall extend for the full width of the facade and be located no

higher than the top of the uppermost story included in the layer.

b. Top

i. The top building layer shall include at least twice as many stories as the base building

layer and include all remaining above-grade stories not included in the base building layer.

ii. A roofline cornice articulating element shall be applied to the top building layer that is the topmost story of the building or the topmost story before a street step-back. See Sec. 3D.6.5.C.4. (Roofline Cornice).

iii. The roofline cornice shall extend for the full width of the facade and be located along

the top of the topmost story included in the building layer.

iv. When the top building layer does not include the topmost story of the building or

the topmost story before a street step-back, at least one of the following articulating elements shall be applied along the top of the top layer, creating a transition between the top building layer and any story above:

a) Sec. 3D.6.5.C.1. (Material Change); or

b) Sec. 3D.6.5.C.2. (Belt Course).

v. The articulating element shall extend for the full width of the building and be located along the top of the topmost story included in the building layer.

D. Measurement

For measurement of stories see Sec. 2C.4.3. (Height in Stories).

Sec. 3D.6.2. (Base-Top Articulation) | 3-100 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.6. (Articulation) Zoning Code Chapter 1A

E. Exceptions

Where the applied Form District (Part 2B.) requires a street step-back depth of 10 feet or greater, the top building layer may terminate at the topmost story below the street step-back. No articulating element is required above the top building layer.

F. Relief

  1. Base-top articulation standards may be met through alternative compliance in accordance with Sec. 13B.5.1. (Alternative Compliance).

  2. A deviation from number of stories in building layers of one story may be granted in accordance with Sec. 13B.5.2. (Adjustment).

  3. Deviation from any base-top articulation standard may be granted as a variance in accordance with Sec. 13B.5.3. (Variance).

Sec. 3D.6.2. (Base-Top Articulation) | 3-101 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.6. (Articulation) Zoning Code Chapter 1A

Exceptions & meaning →

Sec. 3D.6.3. HORIZONTAL BAND ARTICULATION

Horizontal band articulation is a continuous band of material running horizontally across a facade.

A. Intent

The intent of the standards of this Section (Horizontal Band Articulation) is to separate and align windows on a building facade in a way that contributes to the established architectural character of surrounding neighborhoods or districts.

B. Applicability

Horizontal band articulation standards apply to new construction or an exterior modification

when the applied Character Frontage District (Div. 3B.9.) requires horizontal band articulations on facades pursuant to Sec. 3A.2.2.B.3. (Frontage Applicable Facades).

C. Standards

Horizontal band articulation shall meet the following standards:

  1. Be no less than eight inches in height,

  2. Extend for the full width of the facade, interrupted only by required articulating elements or architectural features. Architectural features that interrupt either required vertical band articulation or required horizontal band articulation shall cover cumulatively no more than 30 percent of the total facade area. A maximum of five architectural features that interrupt required vertical band articulation or horizontal band articulation are allowed on the facade area of any individual building width.

D. Measurement

  1. Horizontal band articulation height is measured vertically from the lowest point to the highest point of a horizontal band articulation meeting the standards above.

  2. The facade area covered by an architectural feature that interrupts horizontal band articulation or vertical band articulation is measured as the area of the smallest rectangle that fully circumscribes the architectural feature.

E. Relief

  1. Horizontal band articulation standards may be met through alternative compliance in accordance with Sec. 13B.5.1. (Alternative Compliance).

  2. A deviation from horizontal band articulation dimensional standards up to 15 percent may be granted in accordance with Sec. 13B.5.2. (Adjustment).

  3. Deviation from any horizontal band articulation standard may be granted as a variance in accordance with Sec. 13B.5.3. (Variance).

Sec. 3D.6.3. (Horizontal Band Articulation) | 3-102 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.6. (Articulation) Zoning Code Chapter 1A

Exceptions & meaning →

Sec. 3D.6.4. VERTICAL BAND ARTICULATION

Vertical band articulation is a continuous band of material running vertically up a facade.

A. Intent

The intent of the standards of this Section (Vertical Band Articulation) is to separate and align windows on a building facade in a way that contributes to the established architectural character of surrounding neighborhoods or districts.

B. Applicability

Vertical band articulation standards apply to new construction or an exterior modification when the applied Character Frontage District (Div 3B.9.) requires vertical band articulations on facades pursuant to Sec. 3A.2.2.B.3. (Frontage Applicable Facades).

C. Standards

Vertical band articulation shall meet the following standards:

  1. Be no less than eight inches in width, and

  2. Extend uninterrupted for the full height of all build-to applicable stories, only interrupted by horizontal band articulation, required articulating elements or architectural features. Architectural features that interrupt either required vertical band articulation or required horizontal band articulation shall cover cumulatively no more than 30 percent of the total facade area. A maximum of five architectural features that interrupt required vertical band articulation or required horizontal band articulation are allowed on the facade of any individual building width.

D. Spacing

  1. Vertical band articulation shall be applied across the full width of a facade separated by no more than the maximum spacing and no less than the minimum spacing specified by the applied Frontage District (Part 3B.).

  2. Vertical band articulation shall also be located at each corner of a building facade.

E. Measurement

  1. Vertical band articulation width is measured parallel to the applicable facade and horizontally from one end of a vertical band meeting the standards above to the opposite end.

  2. Vertical band articulation spacing is measured horizontally and perpendicular to the applicable building facade from edge of vertical band to edge of vertical band.

  3. The facade area covered by an architectural feature that interrupts horizontal band articulation or vertical band articulation is measured as the area of the smallest rectangle that fully circumscribes the architectural feature.

Sec. 3D.6.4. (Vertical Band Articulation) | 3-103 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.6. (Articulation) Zoning Code Chapter 1A

F. Relief

  1. Vertical band articulation standards may be met through alternative compliance in accordance with Sec. 13B.5.1. (Alternative Compliance). 2. A deviation from vertical band articulation dimensional standards up to 15 percent may be granted in accordance with Sec. 13B.5.2. (Adjustment). 3. Deviation from any vertical band articulation standard may be granted as a variance in accordance with Sec. 13B.5.3. (Variance).

Sec. 3D.6.4. (Vertical Band Articulation) | 3-104 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.6. (Articulation) Zoning Code Chapter 1A

Exceptions & meaning →

Sec. 3D.6.5. ARTICULATING ELEMENTS

Articulating elements are permanent architectural details used to embellish a facade design to accentuate an articulation technique or facade composition.

A. Intent

The intent of the standards of this Section (Articulating Elements) is to provide visual interest to
the public realm and break up a building facade with visually separate building layers in a way that
contributes to the established architectural character of surrounding neighborhoods or districts.

B. Applicability

Articulating element standards apply to new construction or an exterior modification when the
applied Character Frontage District (Div. 3B.9.) requires articulating elements on facades pursuant
to Sec. 3A.2.2.B.3 (Frontage Applicable Facades).

C. Articulating Element Options

1. Material Change

a. Standards

i. The principal exterior material applied to the building layer shall be different from the
principal siding treatment applied to the abutting building layers.

ii. The principal exterior material shall be limited to those allowed by the applied
Frontage District (Part 3B.).

iii. One of the following architectural details must be provided between building layers
applying the material change articulating element:

a) A belt course located at the transition from one principal exterior material to the
next. See Paragraph 2. (Belt Course) below; or

b) The building layer applying a material change articulating element shall be
recessed or project from the abutting building layers at least three inches.

b. Measurement

i. In measuring material change, principal exterior materials are considered different if
they are entirely different materials or products having the same base material where
the unit size or finish surface texture is visibly contrasting.

ii. Recessed building layers are measured horizontally from and perpendicular to the
immediately surrounding facade to the outermost point of the recessed building layer
facade.

iii. Projecting building layers are measured horizontally and perpendicular from the
immediately surrounding facade to the innermost point of the projecting building layer
facade.

Sec. 3D.6.5. (Articulating Elements) | 3-105 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.6. (Articulation) Zoning Code Chapter 1A

2. Belt Course

A horizontal course projecting beyond the face of the surrounding building facade often
shaped to mark a division in the facade wall.

a. Standards

A belt course shall meet the following standards:

i. Extend uninterrupted for the full width of the building layer.

ii. Have a consistent profile across the width of the building.

iii. Project a minimum of two inches from the immediately surrounding facade for some
portion of the top two inches and the bottom two inches of the belt course profile,

iv. Have a height of no less than 12 inches if located on the first story. An additional two
inches in height are required for each story that the belt course is located about the
first story. The greatest required minimum height is 48 inches.

b. Measurement

i. Belt course height is measured vertically from the lowest point to the highest point of
the belt course profile meeting the standards in subparagraph a above.

ii. Projection is measured perpendicularly from the immediately surrounding facade to
the outermost point of a belt course meeting the standards in the subparagraph a
above.

3. Shopfront Cornice

A continuous molded projection located above a series of display windows on the ground
story facade.

a. Standards

A shopfront cornice shall meet the following standards:

i. Extend uninterrupted for the width of the building layer.

ii. Project a minimum of four inches from the immediately surrounding facade for some
portion of the top four inches and the bottom four inches of the cornice profile.

iii. Have a height of no less than 12 inches.

b. Measurement

i. Shopfront cornice height is measured vertically from the lowest point to the highest
point of the cornice profile meeting the standards in subparagraph a above.

Sec. 3D.6.5. (Articulating Elements) | 3-106 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.6. (Articulation) Zoning Code Chapter 1A

ii. Projection is measured perpendicularly from the immediately surrounding facade horizontally to the outermost point of a shopfront cornice meeting the standards in the subparagraph a above.

4. Roofline Cornice

A continuous molded projection that crowns a wall, often as part of a parapet.

a. Standards

A roofline cornice shall meet the following standards:

i. Extend uninterrupted for the full width of the building layer.

ii. Project a minimum of four inches from the immediately surrounding facade for some
portion of the top four inches of the cornice profile if located on the first, second or
third stories. An additional two inches of projection are required for each story the
roofline cornice is located above the third story. A minimum projection of at least 36
inches is required.

iii. Have a height of no less than 12 inches if located on the first, second or third story.
An additional two inches in height are required for each story the roofline cornice is
located above the third story. A minimum height of at least 48 inches is required.

b. Measurement

i. Roofline cornice height is measured vertically from the lowest point to the highest
point of the cornice profile meeting the standards above.

ii. Projection is measured perpendicularly from the immediately surrounding facade
horizontally to the outermost point of a roofline cornice meeting the standards in the
subparagraph a above.

D. Measurement

Articulating elements are measured as "provided" or "not provided" based on whether the
applicable building layer facade applies an articulating element meeting the standards above.

E. Relief

1. Articulating elements standards may be met through alternative compliance in accordance
with Sec. 13B.5.1. (Alternative Compliance).

2. A deviation from articulating elements dimensional standards up to 10 percent may be granted
in accordance with Sec. 13B.5.2. (Adjustment).

3. Deviation from any articulating elements standard may be granted as a variance in accordance
with Sec. 13B.5.3. (Variance).

Sec. 3D.6.5. (Articulating Elements) | 3-107 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.7. (Features) Zoning Code Chapter 1A

Div. 3D.7. FEATURES

Exceptions & meaning →

Sec. 3D.7.1. RESTRICTED FEATURES

A. Intent

The intent of the standards of this Section (Restricted Features) is to ensure facades are built in a way that contributes to the established architectural character of surrounding neighborhoods or districts by limiting the use of architectural features that are inappropriate to the historic or desired context.

B. Applicability

This Section (Restricted Features) applies to new construction or an exterior modification when the applied Character Frontage District (Part 3B.) restricts features on any facade pursuant to Sec. 3A.2.2.B.3. (Frontage Applicable Facades).

C. Standards

Where the applied Frontage District (Part 3B.) lists a feature as "prohibited", no applicable facade located on a build-to applicable story specified by the applied Frontage District (Part 3B.) may include any variety of listed feature.

D. Projecting Balcony

An unenclosed occupiable platform, located at an elevation above the ground story, that is fixed to or integrated with an exterior building facade and projects beyond the floor area of the story immediately below. Balconies include protective barriers such as railings or parapets and may be covered or uncovered.

  1. Standards

Where the applied Frontage District (Part 3B.) lists projecting balcony as "prohibited":

a. No feature meeting the definition for projecting balcony above may be included on an applicable facade.

b. Roof terraces that meet the definition of balcony may be allowed provided they are uncovered and do not project beyond the story immediately below.

  1. Measurement

    Projecting balconies are identified as present or absent based on whether an applicable facade includes a projecting balcony as described above.

Sec. 3D.7.1. (Restricted Features) | 3-108 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.7. (Features) Zoning Code Chapter 1A

E. Relief

  1. Deviation from "restricted features" standards may be met through alternative compliance in accordance with Sec. 13B.5.1. (Alternative Compliance).

  2. Deviation from any "restricted features" standards may be granted as a variance in accordance with Sec. 13B.5.3. (Variance).

Sec. 3D.7.1. (Restricted Features) | 3-109 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.8. (Entrances) Zoning Code Chapter 1A

Div. 3D.8. ENTRANCES

Exceptions & meaning →

Sec. 3D.8.1. STREET-FACING ENTRANCE

For the intent, applicability, standards, measurement, and relief of street-facing entrance see Sec. 3C.5.1. (Street-Facing Entrance).

Sec. 3D.8.1. (Street-Facing Entrance) | 3-110 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.8. (Entrances) Zoning Code Chapter 1A

Exceptions & meaning →

Sec. 3D.8.2. ENTRY FEATURE

For the intent, applicability, standards, measurement, and relief of entry features see Sec. 3C.5.2. (Entry Feature).

Sec. 3D.8.2. (Entry Feature) | 3-111 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.8. (Entrances) Zoning Code Chapter 1A

Exceptions & meaning →

Sec. 3D.8.3. FOCAL ENTRY FEATURE

Focal entry feature are improved design standards applied to the primary entrance along the public realm.

A. Intent

The intent of the standards of this Section (Focal Entry Feature) is to establish a hierarchy of entrances on a building facade where a focal entry feature is the visually dominant entrance supported by secondary entrances designed with entry features.

B. Applicability

Focal entry feature standards apply to new construction, a major remodel, or an exterior modification, when the applied Character Frontage District (Part 3B.) requires a focal entry feature.

When the focal entry feature standards apply, the focal entry feature standards apply to ground story, frontage lot line facing facades.

C. Standards

  1. General

    a. Each building width shall provide at least the minimum number of focal entry features specified by the applied Frontage District (Part 3B.).

b. Each required focal entry feature shall meet the standards for one of the focal entry feature options. See Sec. 3D.8.1.C.2. (Focal Entry Feature Options).

c. Required focal entry features shall abut and provide direct access to a street-facing entrance.

d. Required focal entry features shall provide direct access to the public realm associated with the frontage lot line.

e. For building setback encroachment regulations, see Sec. 2C.2.2.E. (Exceptions).

f. For encroachments into the public right-of-way, see Chapter IX. (Building Regulations),

Sec. 91.32. (Encroachments into the Public Right-of-Way)of this Code.

Sec. 3D.8.3. (Focal Entry Feature) | 3-112 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.8. (Entrances) Zoning Code Chapter 1A

  1. Focal Entry Feature Options

    Packages of design standards applied to the primary entrance along the public realm.

a. Archway b. Architrave A curved symmetrical architectural detail spanning an A decorative horizontal band above and connected opening to an exterior space, set behind the primary to vertical bands framing an opening to an exterior facade plane, providing sheltered access to a street- space, set behind the primary facade plane, providing facing entrance. sheltered access to a street-facing entrance.

C C

B A B A

For measurement For measurement DIMENSIONAL STANDARDS DIMENSIONAL STANDARDS see Sec. 3C.5.2.D. see Sec. 3C.5.2.D. A Clear depth (min) 3' A Clear depth (min) 3' B Clear width (min) 8' B Clear width (min) 8' Clear height (min) 9' Clear height (min) 9' Covered entrance Required Covered entrance Required Covered area (min) 100% Covered area (min) 100% C Finished floor elevation (min/max) -2'/5' C Finished floor elevation (min/max) -2'/5' Transparency (min) 80% Transparency (min) 80% Enclosure (max) 75% Enclosure (max) 75%

Sec. 3D.8.3. (Focal Entry Feature) | 3-113 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.8. (Entrances) Zoning Code Chapter 1A

c. Canopy A space that provides sheltered access to an at-grade street-facing entrance with an overhead projecting structure.

C

B A

For measurement

DIMENSIONAL STANDARDS see Sec. 3C.5.2.D. A Clear depth (min) 4' B Clear width (min) 8' Clear height (min) 9' Covered entrance Required Covered area (min) n/a C Finished floor elevation (min/max) -2'/2' Transparency (min) n/a Enclosure (max) 50%

For encroachments into the public right-of-way, see Chapter IX. (Building Regulations), Sec. 91.32. (Encroachments into the Public Right-of-Way) of this Code.

Sec. 3D.8.3. (Focal Entry Feature) | 3-114 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.8. (Entrances) Zoning Code Chapter 1A

D. Measurement

See Sec. 3C.5.2.D. (Measurement).

E. Relief

  1. Deviation from focal entry feature option standards may be granted in accordance with Sec. 13B.5.1. (Alternative Compliance). 2. A deviation from focal entry feature dimensional standard up to 15 percent may be granted in accordance with Sec. 13B.5.2. (Adjustment). 3. Deviation from any entry feature standard may be granted as a variance in accordance with Sec. 13B.5.3. (Variance).

Sec. 3D.8.3. (Focal Entry Feature) | 3-115 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.9. (Transparency) Zoning Code Chapter 1A

Div. 3D.9. TRANSPARENCY

Exceptions & meaning →

Sec. 3D.9.1. GROUND STORY

A. Intent

The intent of the standards of this Section (Ground Story) is to ensure projects are designed with
ground story windows that contribute to the established architectural character of surrounding
neighborhoods or district.

B. Applicability

Ground story transparency standards apply to new construction, a major remodel, or an exterior
modification when the applied Character Frontage District (Div. 3B.9.) requires ground story
transparency on facades pursuant to Sec. 3A.2.2.B.3. (Frontage Applicable Facades) located on the
ground story and pursuant to Sec. 3A.2.2.B.4. (Frontage Applicable Building Depth).

C. Standards

1. General

a. Standards

i. Frontage applicable facades located on the ground story shall provide no less than the
minimum transparency specified in the applied Character Frontage District (Div. 3B.9.).

ii. Frontage applicable facades located on the ground story shall provide no more than
the maximum transparency specified in the applied Character Frontage District (Div.
3B.9.).

iii. All transparent area shall meet the standards of Sec. 3C.4.1.C. (Standards).

b. Measurement

For transparent area measurement, see Sec. 3C.4.1.D. (Measurement).

2. Active Wall Spacing

See Sec. 3C.4.2. (Active Wall Spacing).

3. Window Recession

The depth that a window is set back from the surrounding facade.

a. Standards

All windows on applicable facades shall be recessed at a minimum depth as specified in
the applied Frontage District (Part 3B.).

Sec. 3D.9.1. (Ground Story) | 3-116 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.9. (Transparency) Zoning Code Chapter 1A

b. Measurement

Window recession depth is measured inward from the immediately surrounding facade surface, exclusive of trim or accessory projecting architectural details, to the outermost element of the window assembly.

  1. Bulkhead

A wall located beneath a display window on the ground story facade that elevates a window above the exterior finished grade and the interior finished floor surface.

a. Standards

i. When listed as "required" in the applied Frontage District (Part 3B.), all ground story window openings located on applicable facades shall be located between 18 and 30 inches above the finished floor of the ground story.

ii. Ground story window openings located entirely above another ground story window
may be located greater than 30 inches from the ground story finished floor provided
that no portion of the opening extends beyond the width of the lower window
opening.

Greater than 30”

18” - 30”

b. Measurement

Bulkheads are measured as "provided" or "not provided" based on the compliance of all
applicable windows with the standards above.

5. Symmetrical Lite Pattern

Window panes that are arranged or designed so that the left-side of the window composition
is a mirror image of the right-side of the window composition.

a. Standards

When listed as “required" in the applied Frontage District (Part 3B.), all windows provided
on applicable facades shall meet the following standards:

i. Divided-lite and simulated divided-lite windows shall have a composition of muntins
or grills that display reflective symmetry.

ii. Operable windows shall have sashes that are reflectively symmetrical.

Sec. 3D.9.1. (Ground Story) | 3-117 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.9. (Transparency) Zoning Code Chapter 1A

iii. Window assemblies sharing a window opening shall be composed in a way that
reflective symmetry is displayed over the entirety of the window opening.

b. Measurement

In meeting symmetrical lite pattern standards, if a vertical line can be drawn through
the window opening, and the pattern and shape on both sides of the line appear
approximately identical, the window or windows are considered in compliance with the
symmetrical lite pattern standard.

Line of Symmetry Line of Symmetry

6. Horizontal Sliding Windows

a. Standards

When listed as "prohibited" in the applied Frontage District (Part 3B.), windows provided on applicable facades shall not include sashes that operate left to right or right to left.

b. Measurement

Horizontal sliding windows are identified as either present or absent.

  1. Vinyl Windows

a. Standards

i. When listed as "prohibited" in the applied Frontage District (Part 3B.), window

assemblies provided on applicable facades shall not contain frames, sashes, rails, styles, muntins, mullions, or grills with a vinyl exterior finish.

ii. Other accessory window assembly components may be finished with vinyl products.

b. Measurement

Vinyl windows are identified as either present or absent.

D. Exceptions

Ground story transparency standards do not apply to parking structure facades unless the applied development standards district requires the facade to be wrapped, see Development Standards District (Part 4B.).

Sec. 3D.9.1. (Ground Story) | 3-118 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.9. (Transparency) Zoning Code Chapter 1A

E. Relief

  1. Up to a 15 percent increase to the total allowed ground story transparent area may be granted in accordance with Sec. 13B.5.2. (Adjustment).

  2. A deviation from ground story transparency dimensional standard up to 15 percent may be granted in accordance with Sec. 13B.5.2. (Adjustment).

  3. Deviation from any ground story transparency standard may be granted as a variance in accordance with Sec. 13B.5.3. (Variance).

Sec. 3D.9.1. (Ground Story) | 3-119 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.9. (Transparency) Zoning Code Chapter 1A

Exceptions & meaning →

Sec. 3D.9.2. UPPER STORIES

A. Intent

The intent of the standards of this Section (Upper Stories) is to ensure projects are designed with
upper story windows that contribute to the established architectural character of surrounding
neighborhoods or districts.

B. Applicability

Upper story standards apply to new construction, a major remodel, or an exterior modification
when the applied Character Frontage District (Div. 3B.9.) requires upper story transparency on
facades pursuant to Sec. 3A.2.2.B.3. (Frontage Applicable Facades) and Sec. 3A.2.2.B.4. (Frontage
Applicable Building Depth).

C. Standards

1. General

a. Standards

i. Applicable upper story facades shall provide at least the minimum transparency
specified in the applied Character Frontage District (Div. 3B.9.).

ii. Applicable upper story facades shall provide no more than the maximum transparency
specified in the applied Character Frontage District (Div. 3B.9.).

iii. All transparent area shall meet the standards of Sec. 3C.4.1.C. (Standards).

b. Measurement

See Sec. 3C.4.1.D.2. (Upper Stories).

2. Window Recession

See Sec. 3D.9.1.C.3. (Window Recession).

3. Symmetrical Lite Pattern

See Sec. 3D.9.1.C.5. (Symmetrical Lite Pattern).

4. Sill

The bottommost horizontal exterior surface of a window opening including a ledge or other
architectural detail that projects from the surrounding building facade.

a. Standards

i. When required by the applied Frontage District (Part 3B.), all windows provided on
applicable facades shall include a sill, ledge or comparable architectural detail located
at the bottommost exterior surface of a window opening.

Sec. 3D.9.2. (Upper Stories) | 3-120 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.9. (Transparency) Zoning Code Chapter 1A

ii. Required sills shall project a minimum of one inch beyond the immediately

surrounding building facade.

iii. Required sills shall have a width of no less than the window opening.

b. Measurement

Sills are measured as "provided" or "not provided" based on the compliance of all

applicable windows with the standards of subparagraph a above.

  1. Horizontal Sliding Windows

See Sec. 3D.9.1.C.6. (Horizontal Sliding Windows).

  1. Vinyl Windows

See Sec. 3D.9.1.C.7. (Vinyl Windows).

D. Exceptions

Upper story transparency standards do not apply to parking structure facades unless the applied Development Standards District (Part 4B.) requires the facade to be wrapped.

E. Relief

  1. Up to a 15 percent increase in the total allowed upper story transparent area may be granted in accordance with Sec. 13B.5.2. (Adjustment).

  2. A deviation up to 15 percent from upper story transparency dimensional standards may be granted in accordance with Sec. 13B.5.2. (Adjustment).

  3. Deviation from any upper story transparency standard may be granted as a variance in accordance with Sec. 13B.5.3. (Variance).

Sec. 3D.9.2. (Upper Stories) | 3-121 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.10. (Exterior Materials) Zoning Code Chapter 1A

Div. 3D.10. EXTERIOR MATERIALS

Exceptions & meaning →

Sec. 3D.10.1. PRINCIPAL MATERIAL COVERAGE

Principal material coverage is defined as the building products used as the primary exterior wall finish materials of the exterior building facade.

A. Intent

The intent of the standards of this Section (Principal Material Coverage) is to visually unify the facade with a dominant material and ensure that building facades are finished with materials that contribute to the established architectural character of surrounding neighborhoods or districts.

B. Applicability

Principal material coverage standards apply to new construction, a major remodel, or an exterior modification. When the principal material coverage standards apply, the standards apply to facades pursuant to Sec. 3A.2.2.B.3. (Frontage Applicable Facades) and any build-to applicable story as specified by the applied Character Frontage District (Div. 3B.9.), and any portion of the frontage applicable facade located above the last provided story where the number of stories provided for any building is less than the specified build-to applicable stories.

C. Standards

  1. General

    a. The total percentage of applicable facade area finished in a primary material shall be no less than the minimum principal material coverage specified by the applied Character Frontage District (Div. 3B.9.).

b. Only exterior material options specified by the applied Character Frontage District (Div. 3B.9.) may be used as a primary material.

c. Only one primary material may used to meet the principal material coverage standard.

  1. Exterior Material Options

    a. For exterior material options standards, see Sec. 3D.10.3. (Exterior Material Options).

D. Measurement

  1. Principal material coverage is calculated for each building width separately.

  2. The principal material coverage percentage is the facade area covered in a principal material divided by the total applicable facade area.

  3. The principal material coverage is measured as compliant or non-compliant based on whether it meets the standards and definition of one of the allowed exterior material options specified

by the applied Frontage District (Part 3B.).

Sec. 3D.10.1. (Principal Material Coverage) | 3-122 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.10. (Exterior Materials) Zoning Code Chapter 1A

E. Exceptions

Principal material coverage standards do not apply to windows nor door openings.

F. Relief

  1. Up to a 10 percent reduction to the total required facade area finished in an allowed primary exterior material may be granted in accordance with Sec. 13B.5.2. (Adjustment). 2. Deviation from any principal material coverage standard may be granted as a variance in accordance with Sec. 13B.5.3. (Variance).

Sec. 3D.10.1. (Principal Material Coverage) | 3-123 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.10. (Exterior Materials) Zoning Code Chapter 1A

Exceptions & meaning →

Sec. 3D.10.2. ACCESSORY MATERIAL COVERAGE

Accessory material coverage is defined as the building products used as an exterior wall finish material to accent or support the principal material.

A. Intent

The intent of the standards of this Section (Accessory Material Coverage) is to visually unify
the facade with a consistent material palette and ensure that building facades are finished with
materials that contribute to the established architectural character of surrounding neighborhoods
or districts.

B. Applicability

1. Accessory material coverage standards shall apply to new construction, a major remodel, or
an exterior modification. When the accessory material coverage standards apply, the standards
apply to any facade pursuant to Sec. 3A.2.2.B.3. (Frontage Applicable Facades) and any build-
to applicable story as specified by the applied Character Frontage District (Div. 3.9.), and
any portion of the frontage applicable facade located above the last provided story where
the number of stories provided for any building is less than the specified build-to applicable
stories.

2. All exterior materials cumulatively covering between five percent and 30 percent of the
total applicable facade area are considered an accessory material and shall comply with all
accessory material coverage, exterior material options, and number of accessory material
standards.

C. Standards

1. General

a. The total percentage of applicable facade area finished in an accessory material shall not
exceed the maximum accessory material coverage specified by the applied Character
Frontage District (Div. 3B.9.).

b. Only exterior material options specified by the applied Character Frontage District (Div.
3B.9.) may be used as an accessory material.

2. Exterior Material Options

For exterior material options standards, see Sec. 3D.10.3. (Exterior Material Options).

3. Number of Accessory Materials

Individual accessory materials may not exceed the maximum number of accessory materials
specified by the applied Character Frontage District (Div. 3B.9.).

Sec. 3D.10.2. (Accessory Material Coverage) | 3-124 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.10. (Exterior Materials) Zoning Code Chapter 1A

D. Measurement

  1. Accessory material coverage is calculated for each building width separately.
  1. Accessory material coverage percentage is the facade area covered in the accessory material product divided by the total applicable facade area. 3. Accessory material coverage is measured as compliant or non-compliant based on whether it meets the standards and definition of one of the exterior material options specified by the applied Character Frontage District (Div. 3B.9.).

    E. Exceptions

    Accessory material coverage standards do not apply to windows nor door openings.

    F. Relief

    1. Up to a 10 percent increase in the total allowed facade area finished in a secondary exterior material may be granted in accordance with Sec. 13B.5.2. (Adjustment).

    2. Deviation from any accessory material standard may be granted as a variance in accordance with Sec. 13B.5.3. (Variance).

Sec. 3D.10.2. (Accessory Material Coverage) | 3-125 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.10. (Exterior Materials) Zoning Code Chapter 1A

Exceptions & meaning →

Sec. 3D.10.3. EXTERIOR MATERIAL OPTIONS

Exterior material options is defined as building products allowed for use as primary or accessory exterior wall finish material.

A. Intent

The intent of the standards of this Section is to ensure that building facades are finished with materials that contribute to the established architectural character of surrounding neighborhoods or districts.

B. Applicability

Exterior material options standards apply to all exterior materials provided and shall comply with principal material coverage or accessory material coverage standards as specified by the applied Character Frontage District (Div. 3B.9.).

C. Standards

  1. General

Proposed principal and accessory materials shall meet all standards and definitions of one of the exterior material options specified by the applied Character Frontage District (Div. 3B.9.) to comply with principal material coverage and accessory material coverage standards.

Sec. 3D.10.3. (Exterior Material Options) | 3-126 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.10. (Exterior Materials) Zoning Code Chapter 1A

  1. Exterior Material Options

a. Brickwork b. Stonework Courses of rectangular masonry units made of Stacked rocks quarried and worked into a specific hardened clay, laid with mortar exposed between size and shape for use as a building material. Solid bricks. Examples include solid brick construction, brick stone includes mortar and other products required veneer and thin brick veneer. Other products required for installation that are visually incidental to the stone for installation that are visually incidental to the brick product. Examples include solid stone construction, are also included. stone veneer, and thin stone veneer. Solid stone excludes heavy aggregate concrete, terrazzo, engineered stone products, and comparable materials.

INTENT INTENT To provide structures with a human scale, durability, and To provide structures with a human scale, durability, a connection to local history. The profile of brickwork and a connection to nature and local history. The creates a pattern of channels along the mortar beds profile of stonework provides dynamic shadow line and perpends providing shadow line effects and texture effects relating to the scale of individual stones, helping reflecting the scale of the individual brick units. The size observers to relate to the overall scale of the structure. of the brick units are of a commonly recognized scale The organic textures and deep natural colors of exposed related to its manual assembly which naturally helps stone faces provide observers with a connection to observers relate to the overall scale of the structure and nature. Solid stone assemblies provide lasting durability recognize the building as a result of tangible human against weather and wear, reducing maintenance activities rather than machined or synthetic installations. demands. Used as an exterior building material in some Brick assemblies provide lasting durability against of Los Angeles most treasured historic buildings, solid weather and wear, reducing maintenance demands. stone assemblies connect observers to local history. Used as an exterior building material in some of Los DIMENSIONAL STANDARDS Angeles most treasured historic buildings, brickwork n/a connects observers to local history. DIMENSIONAL STANDARDS i. Individual brick units shall have a height of between 1.5 and 8 inches.

ii. Individual brick units shall have a width of between 3.5 and 16 inches.

Sec. 3D.10.3. (Exterior Material Options) | 3-127 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.10. (Exterior Materials) Zoning Code Chapter 1A

c. Concrete d. Metal A cement based product either poured-in-place or pre- Metal products designed and intended for architectural cast in a form or mold. Concrete includes engineered purposes. Examples include exposed structural steel, masonry products set in resin or cement such as architectural metal panels, and decorative metal terrazzo, terracotta, CMU, breeze block, and exposed products. Other products required for installation that columns and beams. Other products required for are visually incidental to the metal product are also installation that are visually incidental to the concrete included. product are also included. Concrete excludes fiber cement products, brick, EFIS, and stucco.

INTENT INTENT To provide structures with the lasting durability and To provide structures with the lasting durability and a sense of weight and permanence through use of sense of permanence through use of metal. concrete. DIMENSIONAL STANDARDS DIMENSIONAL STANDARDS Not applicable Not applicable

Sec. 3D.10.3. (Exterior Material Options) | 3-128 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.10. (Exterior Materials) Zoning Code Chapter 1A

e. Wood f. Glazed Tile Tree-based products milled into a particular shape and Ceramic tile having porcelain or natural clay body, size for use as an exterior building material. Examples glazed for surfacing walls, typically attached to an include wood panels, structural lumber such as cross exterior wall with mortar and finished by filling joints laminated timber and glulam beams, plank siding, and between tiles with a cement- or resin-based grout shingles. Wood excludes products with exposed faces product. Examples include small or large format tile composed substantially of wood chips, particles, and and structural facing tile. Other products required fibers. Examples include structural composite lumber for installation that are visually subordinate to the like PSL, LSL, and OSL, and composite panel products tile product are also allowed. Glazed tile excludes like OSB, fiberboard, and particleboard. Wood also terracotta and other non-ceramic tile products. excludes faux-wood products such as vinyl, aluminum, and fiber cement siding. Other products required for installation that are visually incidental to the wood product are also included.

INTENT INTENT To provide structures with a connection to nature and To provide structures with a human scale, durability, and local history through use of wood. The organic patterns a connection to local history. The profile of glazed tile and warm natural colors of exposed wood provide assemblies provides a regular pattern of channels along observers with a connection to nature. Used as an grout joints, creating shadow line effects and texture exterior building material in some of Los Angeles most reflecting the scale of the individual tile units. Glazed treasured historic buildings, wood products connect tile assemblies provide lasting durability against weather observers to local history. and wear, reducing maintenance demands. Used as an exterior building material in some of Los AngelesDIMENSIONAL STANDARDS most treasured historic buildings, glazed tile assemblies Not applicable connect observers to local history with their familiar luster and sheen. DIMENSIONAL STANDARDS Not applicable

Sec. 3D.10.3. (Exterior Material Options) | 3-129 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.10. (Exterior Materials) Zoning Code Chapter 1A

g. Horizontal Plank Siding h. Vertical Plank Siding Courses of long, thin horizontal boards, often Courses of long, thin vertical boards, often overlapping overlapping or interlocking horizontally but also or interlocking vertically but also including open joint including open joint systems. Horizontal plank siding systems. Vertical plank siding includes, board and includes clapboard, bevel, lap, weatherboard, shiplap, batten, tongue and groove, shiplap, and rain screen and rain screen siding and may be composed of a siding and may be composed of a wide range of wide range of materials including wood, fiber cement materials including wood, fiber cement products, and products, and vinyl. Horizontal plank cladding excludes vinyl. Vertical plank cladding excludes textured panel textured panel products with unit sizes exceeding 10 products with continuous reveal dimensions greater inches in height regardless of the pattern or texture. than 16 inches in width regardless of the pattern or texture.

INTENT INTENT To provide a human scale to buildings. The profile of To provide a human scale to buildings. The profile the siding assembly creates a pattern of horizontal of the siding assembly creates a pattern of vertical channels providing deep shadow line effects and texture channels providing deep shadow line effects and texture reflecting the scale of the individual board units. The reflecting the scale of the individual board units. The scale of the board units are of a commonly recognized scale of the board units are of a commonly recognized scale related to its manual assembly which naturally scale related to its manual assembly which naturally helps observers to understand and relate to the overall helps observers to understand and relate to the overall scale of the structure and recognize the building as a scale of the structure and recognize the building as a result of tangible human activities rather than machined result of tangible human activities rather than machined or synthetic installations. or synthetic installations. DIMENSIONAL STANDARDS DIMENSIONAL STANDARDS i. Individual board units shall have a height of between i. Individual board units shall have a width of between 1 2 and 10 inches. and 16 inches.

ii. Overlapping or interlocking board units may have a ii. Overlapping or interlocking board units may have a height greater than 10 inches provided no board unit width greater than 16 inches provided no board unit is exposed for a continuous height of more than 10 is exposed for a continuous width of more than 16 inches. inches.

iii. Open joint systems shall not provide a gap greater iii. Open joint systems shall not provide a gap greater than 3/4" between board units. than 3/4" between board units.

Sec. 3D.10.3. (Exterior Material Options) | 3-130 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.10. (Exterior Materials) Zoning Code Chapter 1A

i. Shingle Siding j. Stucco Courses of short, thin building materials, overlapping A building material composed primarily of Portland horizontally. Shingle siding includes square, round, cement, finely ground limestone, sand and water, half-cove, and hexagon, shaped shingles and be applied directly onto a building over a reinforcing base composed of a wide range of materials including mesh. Stucco excludes textured panel products and cedar, cementitious fiberboard, and vinyl. Shingle synthetic stucco such as EIFS, elastomeric stucco, and siding excludes asphalt roofing shingles and textured acrylic stucco. panel products with continuous reveal dimensions greater than 24 inches in width or 12 inches in height regardless of the pattern or texture.

INTENT INTENT To provide a human scale to buildings. The profile of To provide structures with durability and a connection the shingle assembly creates a pattern of vertical and local history. Stucco provides lasting durability against horizontal channels providing deep shadow line effects weather and wear, reducing maintenance demands. and texture reflecting the scale of the individual shingle Used as an exterior building material in some of Los units. The scale of the shingle units are of a commonly Angeles most treasured historic buildings, stucco recognized scale related to its manual assembly which connects observers to local history. naturally helps observers to understand and relate to the DIMENSIONAL STANDARDS overall scale of the structure and recognize the building Not applicable as a result of tangible human activities rather than machined or synthetic installations. DIMENSIONAL STANDARDS i. Individual shingle units shall have a width of between 2 and 24 inches.

ii. Individual shingle units shall have a height of between 2 and 12 inches.

iii. Shingle units may have a width greater than 24 inches or a height greater than 12 inches provided no individual shingle is exposed for a continuous width of more than 24 inches or a continuous height of more than 12 inches.

Sec. 3D.10.3. (Exterior Material Options) | 3-131 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.10. (Exterior Materials) Zoning Code Chapter 1A

D. Measurement

1. The height of individual board, brick, or shingle unit is measured as the greatest dimension
from one end of the unit to the opposite end of the unit, measured vertically and based on the
proposed installation pattern.

2. The width of individual board, brick, or shingle unit is measured as the greatest dimension from
one end of the unit to the opposite end of the unit, measured horizontally and based on the
proposed installation pattern.

3. Exposed width is measured as the largest horizontal dimension of a board or shingle unit that
is uninterrupted by either, another board or shingle covering the first unit, or a gap or break in
the board or shingle unit, for the full height of the unit.

4. Exposed height is measured as the largest vertical dimension of a board or shingle unit that is
uninterrupted by either, another board or shingle covering the first unit, or a gap or break in
the board or shingle unit, for the full height of the unit.

SHINGLE SIDING (SQUARE) VERTICAL PLANK (BOARD & BATTEN)

Total Width

Total Total Width Height
Exposed
Height

Exposed Exposed
Width Width

  1. Gap between board units is measured as the distance between board units at the widest point.

    E. Relief

    1. Deviation from exterior material option standards may be granted in accordance with Sec. 13B.5.1. (Alternative Compliance).

    2. Up to a 10 percent modification to any exterior material option dimensional standard may be granted in accordance with Sec. 13B.5.2. (Adjustment).

    3. Deviation from any exterior material option standard may be granted as a variance in accordance with Sec. 13B.5.3. (Variance).

Sec. 3D.10.3. (Exterior Material Options) | 3-132 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.11. (Roof Design) Zoning Code Chapter 1A

Div. 3D.11. ROOF DESIGN

Exceptions & meaning →

Sec. 3D.11.1. ROOF FORM

Roof form is defined as the shape of the external upper covering of a building, including the frame for supporting the roofing.

A. Intent

The intent of the standards of this Section (Roof Design) is to ensure that building forms contribute to the established architectural character of surrounding neighborhoods or districts.

B. Applicability

  1. Roof form standards apply to new construction, a major remodel, or an exterior modification when the applied Character Frontage District (Div. 3B.9.) requires a primary roof form on any frontage lot line-facing buildings.

  2. A minimum of 70 percent of the total roof area of each applicable building or structure shall meet roof form standards, measured horizontally.

C. Standards

  1. General

    All building and structures shall have a roof form listed as a roof form option in the applied Frontage District (Part 3B.).

  2. Roof Form Options

    a. Flat

    A roof with a maximum pitch of 2:12 (two inch of vertical rise for every 12 inches of horizontal span) or less. Flat roof forms include roofs with parapets up to six feet in height.

D. Measurement

  1. Roof pitch is measured by calculating a roof's vertical rise in inches divided by a foot of its horizontal span and is represented as a ratio.

  2. Roof form is measured as compliant or non-compliant based on whether it meets the standards and definition of one of the roof form options allowed by the applied Frontage District (Part 3B.).

E. Relief

  1. Up to a 10 percent reduction in the total required roof area having an allowed roof form may be granted in accordance with Sec. 13B.5.2. (Adjustment).

Sec. 3D.11.1. (Roof Form) | 3-133 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.11. (Roof Design) Zoning Code Chapter 1A

  1. A deviation from roof form dimensional standard up to 10 percent may be granted in accordance with Sec. 13B.5.2. (Adjustment).

  2. Deviation from any roof form standard may be granted as a variance in accordance with Sec. 13B.5.3. (Variance).

Sec. 3D.11.1. (Roof Form) | 3-134 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025

[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] City of Los Angeles Div. 3D.11. (Roof Design) Zoning Code Chapter 1A

Exceptions & meaning →

Sec. 3D.11.2. ROOF MATERIALS

A. Intent

The intent of the standards of this Section (Roof Materials) is to ensure that a building's roof finishing materials contribute to the established architectural character of surrounding neighborhoods or districts.

B. Applicability

This Section (Roof Materials) applies to new construction, a major remodel, or an exterior modification. When roof materials standards apply, the standards apply to all portions of a required primary roof form pursuant to Sec. 3D.11.1. (Roof Form) on any frontage lot line-facing buildings

on a lot.

C. Standards

Only roof materials specified by the applied Frontage District (Part 3B.) shall be used to finish an applicable roof.

D. Measurement

Roof materials are measured as compliant or non-compliant based on whether all applicable roofs

meet the roof materials standards.

E. Exceptions

Roof material standards do not apply to accessory roof forms.

F. Relief

  1. Up to a 10 percent reduction in the total required roof area finished of an allowed roof material may be granted in accordance with Sec. 13B.5.2. (Adjustment).

  2. Deviation from roof materials standards may be granted as a variance in accordance with Sec. 13B.5.3. (Variance).

Sec. 3D.11.2. (Roof Materials) | 3-135 Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025