Chapter 5 — WATER HEATERS

510.2 Multiple Appliance Vent Table 510.2(1) throughTable 510.2(9).

California Plumbing Code (Title 24, Part 5) · 2019 edition · updated 2026-09-10 · California

Italicized text is a California amendment to the model code, as printed in the official publication.

Venting Table 510.2(1) through Table 510.2(9) shall not be used where obstructions are installed in

509.6.1, and where vents terminate in accordance with Section 509.6.1(2), the outdoor portion of the vent shall be enclosed as required by this paragraph for vents not considered to be exposed to the outdoors, or such venting system shall be engineered. A Type B vent passing through an unventilated enclosure or chase insulated to a value of not less than R-8 shall not be considered to be exposed to the outdoors. Table 510.1.2(3) in combination with Table 510.1.2(6) shall be used for clay-tile-lined exterior masonry chimneys, provided all of the following requirements are met: (1) The vent connector is Type B double wall. (2) The vent connector length is limited to 18 inches per

inch (18 mm/mm) of vent connector diameter.

(2) The vent connector length is limited to 18 inches per

inch (18 mm/mm) of vent connector diameter. (3) The appliance is draft hood-equipped. (4) The input rating is less than the maximum capacity

given in Table 510.1.2(3).

(4) The input rating is less than the maximum capacity

given in Table 510.1.2(3). (5) For a water heater, the outdoor design temperature

shall be not less than 5°F (-15°C).

(5) For a water heater, the outdoor design temperature

shall be not less than 5°F (-15°C). (6) For a space-heating appliance, the input rating is

greater than the minimum capacity given by Table

(6) For a space-heating appliance, the input rating is

greater than the minimum capacity given by Table 510.1.2(6). [NFPA 54:13.1.11] 510.1.11 Corrugated Vent Connector Size. Corrugated vent connectors shall not be smaller than the listed appliance categorized vent diameter, flue collar diameter, or draft hood outlet diameter. [NFPA 54:13.1.12] 510.1.12 Upsizing. Vent connectors shall not be upsized more than two sizes exceeding the listed appliance categorized vent diameter, flue collar diameter, or draft hood outlet diameter. [NFPA 54:13.1.13] 510.1.13 Single Run of Vent. In a single run of vent or vent connector, more than one diameter and type shall be permitted to be used, provided that the sizes and types are permitted by the tables. [NFPA 54:13.1.14] 510.1.14 Interpolation. Interpolation shall be permitted in calculating capacities for vent dimensions that fall between table entries. [NFPA 54:13.1.15] 510.1.15 Extrapolation. Extrapolation beyond the table entries shall not be permitted. [NFPA 54:13.1.16] 510.1.16 Engineering Methods. For vent heights lower than 6 feet (1829 mm) and higher than shown in the tables, engineering methods shall be used to calculate vent capacities. [NFPA 54:13.1.17] 510.1.17 Height Entries. Where the actual height of a vent falls between entries in the height column of the applicable table in Table 510.1.2(1) through Table 510.1.2(6), one of the following shall be used: (1) Interpolation. (2) The lower appliance input rating shown in the table

entries for FAN Max and NAT Max column values;

2019 CALIFORNIA PLUMBING CODE 103

WATER HEATERS any other purpose or distributed to any other persons or parti es.

the venting system. The installation of vents serving listed appliances with vent dampers shall be in accordance with the appliance manufacturer’s instructions or in accordance with the following: (1) The maximum capacity of the vent connector shall be

determined using the NAT Max column.

(1) The maximum capacity of the vent connector shall be

determined using the NAT Max column. (2) The maximum capacity of the vertical vent or chimney

shall be determined using the FAN + NAT column when

utilizing the shortest possible route. Connectors with longer horizontal lengths than those listed in Table 510.2.1 are permitted under the following conditions: (1) The maximum capacity (FAN Max or NAT Max) of

the vent connector shall be reduced 10 percent for

(2) The maximum capacity of the vertical vent or chimney

shall be determined using the FAN + NAT column when the second appliance is a fan-assisted appliance, or the NAT + NAT column when the second appliance is equipped with a draft hood. (3) The minimum capacity shall be determined as if the

appliance were a fan-assisted appliance, as follows:

The minimum capacity shall be determined as if the

appliance were a fan-assisted appliance, as follows: (a) The minimum capacity of the vent connector shall

be determined using the FAN Min column.

(a) The minimum capacity of the vent connector shall

be determined using the FAN Min column. (b) The FAN + FAN column shall be used when the sec ond appliance is a fan-assisted appliance, and the

(b) The FAN + FAN column shall be used when the sec ond appliance is a fan-assisted appliance, and the FAN + NAT column shall be used when the second appliance is equipped with a draft hood, to determine whether the vertical vent or chimney configuration is not permitted (NA). Where the vent configuration is NA, the vent configuration shall not be permitted and an alternative venting configuration shall be utilized. [NFPA 54:13.2.1] 510.2.1 Vent Connector Maximum Length. The maximum vent connector horizontal length shall be 18 inches per inch (18 mm/mm) of connector diameter as shown in Table 510.2.1, or as permitted by Section 510.2.2. [NFPA 54:13.2.2]

(1) The maximum capacity (FAN Max or NAT Max) of

the vent connector shall be reduced 10 percent for each additional multiple of the length listed in Table 510.2.1. For example, the maximum length listed for a 4 inch (100 mm) connector is 6 feet (1829 mm). With a connector length greater than 6 feet (1829 mm) but not exceeding 12 feet (3658 mm), the maximum capacity must be reduced by 10 percent (0.90 x maximum vent connector capacity). With a connector length greater than 12 feet (3658 mm) but not exceeding 18 feet (5486 mm), the maximum capacity shall be reduced by 20 percent (0.80 x maximum vent capacity). (2) For a connector serving a fan-assisted appliance, the

length greater than 6 feet (1829 mm) but not exceeding 12 feet (3658 mm), the maximum capacity must be reduced by 10 percent (0.90 x maximum vent connector capacity). With a connector length greater than 12 feet (3658 mm) but not exceeding 18 feet (5486 mm), the maximum capacity shall be reduced by 20 percent (0.80 x maximum vent capacity). (2) For a connector serving a fan-assisted appliance, the

minimum capacity (FAN Min) of the connector shall

TABLE 510.2.1 VENT CONNECTOR MAXIMUM LENGTH

[NFPA 54: TABLE 13.2.2]

CONNECTOR DIAMETER
(inches)
MAXIMUM CONNECTOR
HORIZONTAL LENGTH
(feet)
12
12
12
12




Length.510.2.2 Vent Connector Exceeding Maximum The vent connector shall be routed to the vent

(2) For a connector serving a fan-assisted appliance, the

minimum capacity (FAN Min) of the connector shall be determined by referring to the corresponding single appliance table. For Type B double-wall connectors, Table 510.1.2(1) shall be used. For single-wall connectors, Table 510.1.2(2) shall be used. The height (H) and lateral (L) shall be measured according to the procedures for a single appliance vent, as if the other appliances were not present. [NFPA 54:13.2.3] 510.2.3 Vent Connector Manifold. Where the vent connectors are combined prior to entering the vertical portion of the common vent to form a common vent manifold, the size of the common vent manifold and the common vent shall be determined by applying a 10 percent reduction (0.90 x maximum common vent capacity) to the common vent capacity part of the common vent tables. The length of the common vent manifold ( LM ) shall not exceed 18 inches per inch (18 mm/mm) of common vent diameter ( D ). [NFPA 54:13.2.4] 510.2.4 Vent Offset. Where the common vertical vent is offset, the maximum capacity of the common vent shall be reduced in accordance with Section 510.2.5, and the horizontal length of the common vent offset shall not exceed 18 inches per inch (18 mm/mm) of common vent diameter ( D ). Where multiple offsets occur in a common vent, the total horizontal length of offsets combined shall not exceed 18 inches per inch (18 mm/mm) of the common vent diameter. [NFPA 54:13.2.5] 510.2.5 Elbow Reduction. For each elbow up to and including 45 degrees (0.79 rad) in the common vent, the maximum common vent capacity listed in the venting tables shall be reduced by 5 percent. For each elbow exceeding 45 degrees (0.79 rad) up to and including 90 degrees (1.57 rad), the maximum common vent capacity listed in the venting tables shall be reduced by 10 percent. [NFPA 54:13.2.6] 510.2.6 Elbows in Connectors. The vent connector capacities listed in the common vent sizing tables include allowance for two 90 degree (1.57 rad) elbows. For each additional elbow up to and including 45 degrees (0.79 rad), the maximum vent connector capacity listed in the

104 2019 CALIFORNIA PLUMBING CODE

WATER HEATERS

diameter of the segment in which the offset is located. (3) For the segment of the common vertical vent con taining the offset, the common vent capacity listed in

»
» » » »

(3) For the segment of the common vertical vent con taining the offset, the common vent capacity listed in the common venting tables shall be reduced by 20 percent (0.80 x maximum common vent capacity). (4) A multistory common vent shall not be reduced in

size above the offset. [NFPA 54:13.2.17]

« « « «
»
» » » »

venting tables shall be reduced by 5 percent. For each elbow greater than 45 degrees (0.79 rad) up to and including 90 degrees (1.57 rad), the maximum vent connector capacity listed in the venting tables shall be reduced by 10 percent. [NFPA 54:13.2.7] 510.2.7 Common Vent Minimum Size. The crosssectional area of the common vent shall be equal to or greater than the cross-sectional area of the largest connector. [NFPA 54:13.2.8] 510.2.8 Tee and Wye Fittings. Tee and wye fittings connected to a common gas vent shall be considered as part of the common gas vent and constructed of materials consistent with that of the common gas vent. [NFPA 54:13.2.9] 510.2.9 Size of Fittings. At the point where tee or wye fittings connect to a common gas vent, the opening size of the fitting shall be equal to the size of the common vent. Such fittings shall not be prohibited from having reduced size openings at the point of connection of appliance gas vent connectors. [NFPA 54:13.2.10] 510.2.10 High-Altitude Installations. Sea level input ratings shall be used where determining maximum capacity for high-altitude installation. Actual input (derated for altitude) shall be used for determining minimum capacity for high-altitude installation. [NFPA 54:13.2.11] 510.2.11 Connector Rise. The connector rise ( R ) for each appliance connector shall be measured from the draft hood outlet or flue collar to the centerline where the vent gas streams come together. [NFPA 54:13.2.12] 510.2.12 Vent Height. For multiple appliances located on one floor, the total height ( H ) shall be measured from the highest draft hood outlet or flue collar up to the level of the outlet of the common vent. [NFPA 54:13.2.13] 510.2.13 Multistory Installations. For multistory installations, the total height ( H ) for each segment of the system shall be the vertical distance between the highest draft hood outlet or flue collar entering that segment and the centerline of the next higher interconnection tee.

e highest draft hood outlet or flue collar up to the level of the outlet of the common vent. [NFPA 54:13.2.13] 510.2.13 Multistory Installations. For multistory installations, the total height ( H ) for each segment of the system shall be the vertical distance between the highest draft hood outlet or flue collar entering that segment and the centerline of the next higher interconnection tee.

[NFPA 54:13.2.14] 510.2.14 Size of Vents for Multistory Installa- tions. The size of the lowest connector and of the vertical vent leading to the lowest interconnection of a multistory system shall be in accordance with Table 510.1.2(1) or Table 510.1.2(2) for available total height (H) up to the lowest interconnection. [NFPA 54:13.2.15] 510.2.15 Vent Type Multistory Installations. Where used in multistory systems, vertical common vents shall be Type B double-wall and shall be installed with a listed vent cap. [NFPA 54:13.2.16] 510.2.16 Offsets in Multistory Installations. Offsets in multistory common vent systems shall be limited to a single offset in each system, and systems with an offset shall comply with the following: (1) The offset angle shall not exceed 45 degrees (0.79

rad) from vertical.

(1) The offset angle shall not exceed 45 degrees (0.79

rad) from vertical. (2) The horizontal length of the offset shall not exceed

18 inches per inch (18 mm/mm) of common vent

The horizontal length of the offset shall not exceed

18 inches per inch (18 mm/mm) of common vent

(4) A multistory common vent shall not be reduced in

size above the offset. [NFPA 54:13.2.17] 510.2.17 Vertical Vent Size Limitation. Where two or more appliances are connected to a vertical vent or chimney, the flow area of the largest section of vertical vent or chimney shall not exceed seven times the smallest listed appliance categorized vent areas, flue collar area, or draft hood outlet area unless designed in accordance with approved engineering methods. [NFPA 54:13.2.18] 510.2.18 Multiple Input Ratings. For appliances with more than one input rate, the minimum vent connector capacity (FAN Min) determined from the tables shall be less than the lowest appliance input rating, and the maximum vent connector capacity (FAN Max or NAT Max) determined from the table shall exceed the highest appliance input rating. [NFPA 54:13.2.19] 510.2.19 Corrugated Metallic Chimney LinerReduction. Listed corrugated metallic chimney liner systems in masonry chimneys shall be sized by using Table 510.2(1) or Table 510.2(2) for Type B vents, with the maximum capacity reduced by 20 percent (0.80 x maximum capacity) and the minimum capacity as shown in Table 510.2(1) or Table 510.2(2). Corrugated metallic liner systems installed with bends or offsets shall have their maximum capacity further reduced in accordance with Section 510.2.5 and Section 510.2.6. The 20 percent reduction for corrugated metallic chimney liner systems includes an allowance for one long radius 90 degree (1.57 rad) turn at the bottom of the liner. [NFPA 54:13.2.20] 510.2.20 Chimneys and Vents. Table 510.2(1) through Table 510.2(5) shall be used only for chimneys and vents not exposed to the outdoors below the roof line. A Type B vent or listed chimney lining system passing through an unused masonry chimney flue shall not be considered to be exposed to the outdoors. A Type B vent passing through an unventilated enclosure or chase insulated to a value of not less than R-8 shall not be considered to be exposed to the outdoors. Where vents extend outdoors above the roof more than 5 feet (1524 mm) higher than required by Table 509.6.1, and where vents terminate in accordance with Section 509.6.1(2), the outdoor portion of the vent shall be enclosed as required by this section for vents not considered to be exposed to the outdoors, or such venting system shall be engineered. Table 510.2(6) through Table 510.2(9) shall be used for clay-tile-lined exterior masonry chimneys, provided all the following conditions are met: (1) The vent connector is Type B double-wall. (2) At least one appliance is draft hood-equipped.

2019 CALIFORNIA PLUMBING CODE 105

WATER HEATERS any other purpose or distributed to any other persons or parti es.

WATER HEATERS any other purpose

(3) The combined appliance input rating is less than the

maximum capacity given by Table 510.2(6) (for

«

(3) The combined appliance input rating is less than the

maximum capacity given by Table 510.2(6) (for NAT + NAT) or Table 510.2(8) (for FAN + NAT). (4) The input rating of each space-heating appliance is

greater than the minimum input rating given by

(2) The lower appliance input rating shown in the table

entries for FAN Max and NAT Max column values;

510.2.27 Height Entries. Where the actual height of a vent falls between entries in the height column of the applicable table in Table 510.2(1) through Table 510.2(9), one of the following shall be used: (1) Interpolation.

» »

(4) The input rating of each space-heating appliance is

greater than the minimum input rating given by Table 510.2(7) (for NAT + NAT) or Table 510.2(9) (for FAN + NAT). (5) The vent connector sizing is in accordance with

Table 510.2(3). [NFPA 54:13.2.22]

(5) The vent connector sizing is in accordance with

Table 510.2(3). [NFPA 54:13.2.22] 510.2.21 Vent Connector Sizing. Vent connectors shall not be increased more than two sizes greater than the listed appliance categorized vent diameter, flue collar diameter, or draft hood outlet diameter. Vent connectors for draft hood-equipped appliances shall not be smaller than the draft hood outlet diameter. Where a vent connector size(s) determined from the tables for fanassisted appliance(s) is smaller than the flue collar diameter, the use of the smaller size(s) shall be permitted provided that the installation complies with all of the following conditions: (1) Vent connectors for fan-assisted appliance flue col lars 12 inches (300 mm) in diameter or smaller are

The lower appliance input rating shown in the table

entries for FAN Max and NAT Max column values; and the higher appliance input rating for the FAN Min column values. [NFPA 54:13.2.30]

(1) Vent connectors for fan-assisted appliance flue col lars 12 inches (300 mm) in diameter or smaller are not reduced by more than one table size [e.g., 12 inches to 10 inches (300 mm to 250 mm) is a one size reduction] and those larger than 12 inches (300 mm) in diameter are not reduced more than two table sizes [e.g., 24 inches to 20 inches (600 mm to 500 mm) is a two size reduction]. (2) The fan-assisted appliance(s) is common vented

with a draft hood-equipped appliance(s).

(2) The fan-assisted appliance(s) is common vented

with a draft hood-equipped appliance(s). (3) The vent connector has a smooth interior wall.

[NFPA 54:13.2.24]

»
»
» »

(3) The vent connector has a smooth interior wall.

[NFPA 54:13.2.24] 510.2.22 Combination of Pipe Types and Sizes. All combinations of pipe sizes, single-wall metal pipe, and double-wall metal pipe shall be allowed within any connector run(s) or within the common vent, provided ALL of the appropriate tables permit ALL of the desired sizes and types of pipe, as if they were used for the entire length of the subject connector or vent. Where singlewall and Type B double-wall metal pipes are used for vent connectors within the same venting system, the common vent shall be sized using Table 510.2(2) or Table 510.2(4) as appropriate. [NFPA 54:13.2.25] Where a table permits more than one diameter of pipe to 510.2.23 Multiple Connector and Vent Sizes. be used for a connector or vent, the permitted sizes shall be permitted to be used. [NFPA 54:13.2.26] 510.2.24 Interpolation. Interpolation shall be permitted in calculating capacities for vent dimensions that fall between table entries. [NFPA 54:13.2.27] 510.2.25 Extrapolation. Extrapolation beyond the table entries shall not be permitted. [NFPA 54:13.2.28] 510.2.26 Engineering Methods. For vent heights lower than 6 feet (1829 mm) and higher than shown in the tables, engineering methods shall be used to calculate vent capacities. [NFPA 54:13.2.29]

106 2019 CALIFORNIA PLUMBING CODE

WATER HEATERS

FIGURE 510.1.10 RANGE OF WINTER DESIGN TEMPERATURES USED IN ANALYZING EXTERIOR MASONRY CHIMNEYS IN THE UNITED STATES

«

[NFPA 54: FIGURE F.2.4]

FIGURE 510.1.10 RANGE OF WINTER DESIGN TEMPERATURES USED IN ANALYZING EXTERIOR MASONRY CHIMNEYS IN THE UNITED STATES

2019 CALIFORNIA PLUMBING CODE 107

WATER HEATERS any other purpose or distributed to any other persons or parti es.

TABLE 510.1.2(1) TYPE B DOUBLE-WALL GAS VENT [NFPA 54: TABLE 13.1(a)]*
**NUMBER OF APPLIANCES: ** **NUMBER OF APPLIANCES: ** **NUMBER OF APPLIANCES: ** **NUMBER OF APPLIANCES: ** **NUMBER OF APPLIANCES: ** **NUMBER OF APPLIANCES: ** SINGLE SINGLE SINGLE SINGLE SINGLE SINGLE
**APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** CATEGORY I CATEGORY I CATEGORY I CATEGORY I CATEGORY I CATEGORY I
**APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** CONNECTED DIRECTLY TO VENT CONNECTED DIRECTLY TO VENT CONNECTED DIRECTLY TO VENT CONNECTED DIRECTLY TO VENT CONNECTED DIRECTLY TO VENT CONNECTED DIRECTLY TO VENT
VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch)
3 3 3 4 4 4 5 5 5 6 6 6 7 7 7
APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR
HEIGHT
H
(feet)
LATERAL
L
(feet)

FAN FAN NAT FAN FAN NAT FAN FAN NAT FAN FAN NAT FAN FAN NAT
HEIGHT
H
(feet)
LATERAL
L
(feet)

Min

Max

Max

Min

Max

Max

Min

Max

Max

Min

Max

Max

Min

Max

Max

6
0
2
4
6

0
13
21
25

78
51
49
46

46
36
34
32

0
18
30
36

152
97
94
91

86
67
64
61

0
27
39
47

251
157
153
149

141
105
103
100

0
32
50
59

375
232
227
223

205
157
153
149

0
44
66
78

524
321
316
310

285
217
211
205

8
0
2
5
8

0
12
23
28

84
57
53
49

50
40
38
35

0
16
32
39

165
109
103
98

94
75
71
66

0
25
42
51

276
178
171
164

155
120
115
109

0
28
53
64

415
263
255
247

235
180
173
165

0
42
70
84

583
365
356
347

320
247
237
227

10
0
2
5
10

0
12
23
30

88
61
57
51

53
42
40
36

0
17
32
41

175
118
113
104

100
81
77
70

0
23
41
54

295
194
187
176

166
129
124
115

0
26
52
67

447
289
280
267

255
195
188
175

0
40
68
88

631
402
392
376

345
273
263
245

15
0
2
5
10
15

0
11
22
29
35

94
69
65
59
53

58
48
45
41
37

0
15
30
40
48

191
136
130
121
112

112
93
87
82
76

0
20
39
51
61

327
226
219
206
195

187
150
142
135
128

0
22
49
64
76

502
339
330
315
301

285
225
217
208
198

0
38
64
84
98

716
475
463
445
429

390
316
300
288
275

TABLE 510.1.2(1) TYPE B DOUBLE-WALL GAS VENT [NFPA 54: TABLE 13.1(a)]*
20
0
2
5
10
15
20

0
10
21
28
34
48

97
75
71
64
58
52

61
51
48
44
40
35

0
14
29
38
46
55

202
149
143
133
124
116

119
100
96
89
84
78

0
18
38
50
59
69

349
250
242
229
217
206

202
166
160
150
142
134

0
20
47
62
73
84

540
377
367
351
337
322

307
249
241
228
217
206

0
33
62
81
94
107

776
531
519
499
481
464

430
346
337
321
308
295

30
0
2
5
10
15
20
30

0
9
21
27
33
56
NA

100
81
77
70
64
58
NA

64
56
54
50
NA
NA
NA

0
13
28
37
44
53
73

213
166
160
150
141
132
113

128
112
108
102
96
90
NA

0
14
36
48
57
66
88

374
283
275
262
249
237
214

220
185
176
171
163
154
NA

0
18
45
59
70
80
104

587
432
421
405
389
374
346

336
280
273
261
249
237
219

0
27
58
77
90
102
131

853
613
600
580
560
542
507

475
394
385
371
357
343
321

50
0
2
5
10
15
20
30

0
8
20
26
59
NA
NA

101
86
82
76
70
NA
NA

67
61
NA
NA
NA
NA
NA

0
11
27
35
42
50
69

216
183
177
168
158
149
131

134
122
119
114
NA
NA
NA

0
14
35
45
54
63
84

397
320
312
299
287
275
250

232
206
200
190
180
169
NA

0
15
43
56
66
76
99

633
497
487
471
455
440
410

363
314
308
298
288
278
259

0
22
55
73
85
97
123

932
715
702
681
662
642
605

518
445
438
426
413
401
376

100
0
2
5
10
15
20
30
50
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
0
10
26
33
40
47
NA
NA
218
194
189
182
174
166
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
0
12
33
43
50
59
78
NA
407
354
347
335
321
311
290
NA
NA
NA
NA
NA
NA
NA
NA
NA
0
13
40
53
62
71
92
147
665
566
557
542
528
513
483
428
400
375
369
361
353
344
NA
NA
0
18
52
68
80
90
115
180
997
831
820
801
782
763
726
651
560
510
504
493
482
471
449
405
  • NA: Not applicable.

  • NA: Not applicable.

108 2019 CALIFORNIA PLUMBING CODE

WATER HEATERS

TABLE 510.1.2(1) TYPE B DOUBLE-WALL GAS VENT [NFPA 54: TABLE 13.1(a)] (continued)
**NUMBER OF APPLIANCES: ** **NUMBER OF APPLIANCES: ** **NUMBER OF APPLIANCES: ** **NUMBER OF APPLIANCES: ** **NUMBER OF APPLIANCES: ** **NUMBER OF APPLIANCES: ** SINGLE SINGLE SINGLE SINGLE SINGLE SINGLE
**APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** CATEGORY I CATEGORY I CATEGORY I CATEGORY I CATEGORY I CATEGORY I
**APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** CONNECTED DIRECTLY TO VENT CONNECTED DIRECTLY TO VENT CONNECTED DIRECTLY TO VENT CONNECTED DIRECTLY TO VENT CONNECTED DIRECTLY TO VENT CONNECTED DIRECTLY TO VENT
VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch)
8 8 8 9 9 9 10 10 10 12 12 12 14 14 14
APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR
HEIGHT
H
(feet)
LATERAL
L
(feet)

FAN FAN NAT FAN FAN NAT FAN FAN NAT FAN FAN NAT FAN FAN NAT
HEIGHT
H
(feet)
LATERAL
L
(feet)

Min

Max

Max

Min

Max

Max

Min

Max

Max

Min

Max

Max

Min

Max

Max

6
0
2
4
6

0
53
79
93

698
425
419
413

370
285
279
273

0
63
93
110

897
543
536
530

470
370
362
354

0
75
110
128

1121
675
668
661

570
455
445
435

0
103
147
171

1645
982
975
967

850
650
640
630

0
138
191
219

2267
1346
1338
1330

1170
890
880
870

8
0
2
5
8

0
50
83
99

780
483
473
463

415
322
313
303

0
60
99
117

1006
619
607
596

537
418
407
396

0
71
115
137

1261
770
758
746

660
515
503
490

0
98
154
180

1858
1124
1110
1097

970
745
733
720

0
130
199
231

2571
1543
1528
1514

1320
1020
1010
1000

10
0
2
5
10

0
48
81
104

847
533
522
504

450
355
346
330

0
57
95
122

1096
684
671
651

585
457
446
427

0
68
112
142

1377
852
839
817

720
560
547
525

0
93
149
187

2036
1244
1229
1204

1060
850
829
795

0
124
192
238

2825
1713
1696
1669

1450
1130
1105
1080

15
0
2
5
10
15

0
45
76
99
115

970
633
620
600
580

525
414
403
386
373

0
53
90
116
134

1263
815
800
777
755

682
544
529
507
491

0
63
105
135
155

1596
1019
1003
977
953

840
675
660
635
610

0
86
140
177
202

2380
1495
1476
1446
1418

1240
985
967
936
905

0
114
182
227
257

3323
2062
2041
2009
1976

1720
1350
1327
1289
1250

TABLE 510.1.2(1) TYPE B DOUBLE-WALL GAS VENT [NFPA 54: TABLE 13.1(a)] (continued)
20
0
2
5
10
15
20

0
41
73
95
111
125

1057
711
697
675
654
634

575
470
460
443
427
410

0
50
86
112
129
145

1384
917
902
877
853
830

752
612
599
576
557
537

0
59
101
130
150
167

1756
1150
1133
1105
1078
1052

930
755
738
710
688
665

0
81
135
172
195
217

2637
1694
1674
1641
1609
1578

1350
1100
1079
1045
1018
990

0
107
174
220
248
273

3701
2343
2320
2282
2245
2210

1900
1520
1498
1460
1425
1390

30
0
2
5
10
15
20
30

0
33
69
91
105
119
149

1173
826
811
788
765
743
702

650
535
524
507
490
473
444

0
42
82
107
124
139
171

1548
1072
1055
1028
1002
977
929

855
700
688
668
648
628
594

0
54
96
125
143
160
195

1977
1351
1332
1301
1272
1243
1189

1060
865
851
829
807
784
745

0
74
127
164
187
207
246

3004
2004
1981
1944
1908
1873
1807

1550
1310
1289
1254
1220
1185
1130

0
98
164
209
237
260
305

4252
2786
2759
2716
2674
2633
2555

2170
1800
1775
1733
1692
1650
1585

50
0
2
5
10
15
20
30

0
26
65
86
100
113
141

1297
975
960
935
911
888
844

708
615
605
589
572
556
522

0
33
77
101
117
131
161

1730
1276
1259
1230
1203
1176
1125

952
813
798
773
747
722
670

0
41
90
118
136
151
183

2231
1620
1600
1567
1536
1505
1446

1195
1010
996
972
948
924
876

0
66
118
154
177
195
232

3441
2431
2406
2366
2327
2288
2214

1825
1513
1495
1466
1437
1408
1349

0
86
151
196
222
244
287

4934
3409
3380
3332
3285
3239
3150

2550
2125
2102
2064
2026
1987
1910

100
0
2
5
10
15
20
30
50
0
21
60
80
93
105
131
197
1411
1155
1141
1118
1095
1073
1029
944
770
700
692
679
666
653
627
575
0
25
71
94
109
122
149
217
1908
1536
1519
1492
1465
1438
1387
1288
1040
935
926
910
895
880
849
787
0
30
82
108
126
141
170
241
2491
1975
1955
1923
1892
1861
1802
1688
1310
1170
1159
1142
1124
1107
1071
1000
0
44
107
142
163
181
215
292
3925
3027
3002
2961
2920
2880
2803
2657
2050
1820
1803
1775
1747
1719
1663
1550
0
72
136
180
206
226
265
350
5729
4313
4282
4231
4182
4133
4037
3856
2950
2550
2531
2500
2469
2438
2375
2250

2019 CALIFORNIA PLUMBING CODE 109

WATER HEATERS any other purpose or distributed to any other persons or parti es.

TABLE 510.1.2(1) TYPE B DOUBLE-WALL GAS VENT [NFPA 54: TABLE 13.1(a)] (continued)

NUMBER OF APPLIANCES: SINGLE
**APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** CATEGORY I CATEGORY I CATEGORY I CATEGORY I CATEGORY I CATEGORY I
**APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** CONNECTED DIRECTLY TO VENT CONNECTED DIRECTLY TO VENT CONNECTED DIRECTLY TO VENT CONNECTED DIRECTLY TO VENT CONNECTED DIRECTLY TO VENT CONNECTED DIRECTLY TO VENT
VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch)
16 16 16 18 18 18 20 20 20 22 22 22 24 24 24
APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR
HEIGHT
H
(feet)
LATERAL
L
(feet)

FAN FAN NAT FAN FAN NAT FAN FAN NAT FAN FAN NAT FAN FAN NAT
HEIGHT
H
(feet)
LATERAL
L
(feet)

Min

Max

Max

Min

Max

Max

Min

Max

Max

Min

Max

Max

Min

Max

Max

6
0
2
4
6

0
178
242
276

2983
1769
1761
1753

1530
1170
1160
1150

0
225
300
341

3802
2250
2242
2235

1960
1480
1475
1470

0
296
390
437

4721
2782
2774
2767

2430
1850
1835
1820

0
360
469
523

5737
3377
3370
3363

2950
2220
2215
2210

0
426
555
618

6853
4030
4023
4017

3520
2670
2660
2650

8
0
2
5
8

0
168
251
289

3399
2030
2013
2000

1740
1340
1330
1320

0
212
311
354

4333
2584
2563
2552

2220
1700
1685
1670

0
278
398
450

5387
3196
3180
3163

2750
2110
2090
2070

0
336
476
537

6555
3882
3863
3850

3360
2560
2545
2530

0
401
562
630

7838
4634
4612
4602

4010
3050
3040
3030

10
0
2
5
10

0
161
243
298

3742
2256
2238
2209

1925
1480
1461
1430

0
202
300
364

4782
2868
2849
2818

2450
1890
1871
1840

0
264
382
459

5955
3556
3536
3504

3050
2340
2318
2280

0
319
458
546

7254
4322
4301
4268

3710
2840
2818
2780

0
378
540
641

8682
5153
5132
5099

4450
3390
3371
3340

15
0
2
5
10
15

0
147
229
283
318

4423
2719
2696
2659
2623

2270
1770
1748
1712
1675

0
186
283
346
385

5678
3467
3442
3402
3363

2900
2260
2235
2193
2150

0
239
355
432
479

7099
4304
4278
4234
4192

3620
2800
2777
2739
2700

0
290
426
510
564

8665
5232
5204
5159
5115

4410
3410
3385
3343
3300

0
346
501
599
665

10 393
6251
6222
6175
6129

5300
4080
4057
4019
3980

20
0
2
5
10
15
20

0
139
219
273
306
335

4948
3097
3071
3029
2988
2948

2520
2000
1978
1940
1910
1880

0
175
270
334
372
404

6376
3955
3926
3880
3835
3791

3250
2570
2544
2500
2465
2430

0
220
337
413
459
495

7988
4916
4885
4835
4786
4737

4060
3200
3174
3130
3090
3050

0
269
403
489
541
585

9785
5983
5950
5896
5844
5792

4980
3910
3880
3830
3795
3760

0
321
475
573
631
689

11 753
7154
7119
7063
7007
6953

6000
4700
4662
4600
4575
4550

NUMBER OF APPLIANCES: SINGLE
30
0
2
5
10
15
20
30

0
127
206
259
292
319
369

5725
3696
3666
3617
3570
3523
3433

2920
2380
2350
2300
2250
2200
2130

0
159
252
316
354
384
440

7420
4734
4701
4647
4594
4542
4442

3770
3050
3020
2970
2920
2870
2785

0
199
312
386
431
467
540

9341
5900
5863
5803
5744
5686
5574

4750
3810
3783
3739
3695
3650
3565

0
241
373
456
507
548
635

11 483
7194
7155
7090
7026
6964
6842

5850
4650
4622
4574
4527
4480
4375

0
285
439
535
590
639
739

13 848
8617
8574
8505
8437
8370
8239

7060
5600
5552
5471
5391
5310
5225

50
0
2
5
10
15
20
30

0
113
191
243
274
300
347

6711
4554
4520
4464
4409
4356
4253

3440
2840
2813
2767
2721
2675
2631

0
141
234
295
330
361
412

8774
5864
5826
5763
5701
5641
5523

4460
3670
3639
3585
3534
3481
3431

0
171
283
355
396
433
494

11 129
7339
7295
7224
7155
7086
6953

5635
4630
4597
4542
4511
4479
4421

0
209
336
419
465
506
577

13 767
8980
8933
8855
8779
8704
8557

6940
5695
5654
5585
5546
5506
5444

0
251
394
491
542
586
672

16 694
10 788
10 737
10 652
10 570
10 488
10 328

8430
6860
6818
6749
6710
6670
6603

100
0
2
5
10
15
20
30
50
0
95
172
223
252
277
319
415
7914
5834
5797
5737
5678
5619
5505
5289
4050
3500
3475
3434
3392
3351
3267
3100
0
120
208
268
304
330
378
486
10 485
7591
7548
7478
7409
7341
7209
6956
5300
4600
4566
4509
4451
4394
4279
4050
0
138
245
318
358
387
446
572
13 454
9577
9528
9447
9367
9289
9136
8841
6700
5800
5769
5717
5665
5613
5509
5300
0
169
293
374
418
452
514
659
16 817
11 803
11 748
11 658
11 569
11 482
11 310
10 979
8600
7200
7162
7100
7037
6975
6850
6600
0
204
341
436
487
523
592
752

20 578
14 264
14 204
14 105
14 007
13 910
13 720
13 354
10 300
8800
8756
8683
8610
8537
8391
8100

110 2019 CALIFORNIA PLUMBING CODE

WATER HEATERS

TABLE 510.1.2(2) TYPE B DOUBLE-WALL GAS VENT [NFPA 54: TABLE 13.1(b)]*
**NUMBER OF APPLIANCES: ** **NUMBER OF APPLIANCES: ** **NUMBER OF APPLIANCES: ** **NUMBER OF APPLIANCES: ** **NUMBER OF APPLIANCES: ** **NUMBER OF APPLIANCES: ** SINGLE SINGLE SINGLE SINGLE SINGLE SINGLE
**APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** CATEGORY I CATEGORY I CATEGORY I CATEGORY I CATEGORY I CATEGORY I
**APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR
VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch)
3 3 3 4 4 4 5 5 5 6 6 6 7 7 7
APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR
HEIGHT
H
(feet)
LATERAL
L
(feet)

FAN FAN NAT FAN FAN NAT FAN FAN NAT FAN FAN NAT FAN FAN NAT
HEIGHT
H
(feet)
LATERAL
L
(feet)

Min

Max

Max

Min

Max

Max

Min

Max

Max

Min

Max

Max

Min

Max

Max

6
0
2
4
6

38
39
NA
NA

77
51
NA
NA

45
36
33
31

59
60
74
83

151
96
92
89

85
66
63
60

85
85
102
114

249
156
152
147

140
104
102
99

126
123
146
163

373
231
225
220

204
156
152
148

165
159
187
207

522
320
313
307

284
213
208
203

8
0
2
5
8

37
39
NA
NA

83
56
NA
NA

50
39
37
33

58
59
77
90

164
108
102
95

93
75
69
64

83
83
107
122

273
176
168
161

154
119
114
107

123
121
151
175

412
261
252
243

234
179
171
163

161
155
193
223

580
363
352
342

319
246
235
225

10
0
2
5
10

37
39
52
NA

87
61
56
NA

53
41
39
34

57
59
76
97

174
117
111
100

99
80
76
68

82
82
105
132

293
193
185
171

165
128
122
112

120
119
148
188

444
287
277
261

254
194
186
171

158
153
190
237

628
400
388
369

344
272
261
241

15
0
2
5
10
15

36
38
51
NA
NA

93
69
63
NA
NA

57
47
44
39
NA

56
57
75
95
NA

190
136
128
116
NA

111
93
86
79
72

80
80
102
128
158

325
225
216
201
186

186
149
140
131
124

116
115
144
182
220

499
337
326
308
290

283
224
217
203
192

153
148
182
228
272

713
473
459
438
418

388
314
298
284
269

20
0
2
5
10
15
20

35
37
50
NA
NA
NA

96
74
68
NA
NA
NA

60
50
47
41
NA
NA

54
56
73
93
NA
NA

200
148
140
129
NA
NA

118
99
94
86
80
NA

78
78
100
125
155
186

346
248
239
223
208
192

201
165
158
146
136
126

114
113
141
177
216
254

537
375
363
344
325
306

306
248
239
224
210
196

149
144
178
222
264
309

772
528
514
491
469
448

428
344
334
316
301
285

TABLE 510.1.2(2) TYPE B DOUBLE-WALL GAS VENT [NFPA 54: TABLE 13.1(b)]*
30
0
2
5
10
15
20
30

34
37
49
NA
NA
NA
NA

99
80
74
NA
NA
NA
NA

63
56
52
NA
NA
NA
NA

53
55
72
91
115
NA
NA

211
164
157
144
131
NA
NA

127
111
106
98
NA
NA
NA

76
76
98
122
151
181
NA

372
281
271
255
239
223
NA

219
183
173
168
157
NA
NA

110
109
136
171
208
246
NA

584
429
417
397
377
357
NA

334
279
271
257
242
228
NA

144
139
171
213
255
298
389

849
610
595
570
547
524
477

472
392
382
367
349
333
305

50
0
2
5
10
15
20
30

33
36
48
NA
NA
NA
NA

99
84
80
NA
NA
NA
NA

66
61
NA
NA
NA
NA
NA

51
53
70
89
112
NA
NA

213
181
174
160
148
NA
NA

133
121
117
NA
NA
NA
NA

73
73
94
118
145
176
NA

394
318
308
292
275
257
NA

230
205
198
186
174
NA
NA

105
104
131
162
199
236
315

629
495
482
461
441
420
376

361
312
305
292
280
267
NA

138
133
164
203
244
285
373

928
712
696
671
646
622
573

515
443
435
420
405
389
NA

100
0
2
5
10
15
20
30
50
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
49
51
67
85
132
NA
NA
NA
214
192
186
175
162
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
69
70
90
113
138
168
231
NA
403
351
342
324
310
295
264
NA
NA
NA
NA
NA
NA
NA
NA
NA
100
98
125
153
188
224
301
NA
659
563
551
532
511
487
448
NA
395
373
366
354
343
NA
NA
NA
131
125
156
191
230
270
355
540
991
828
813
789
764
739
685
584
555
508
501
486
473
458
NA
NA
  • NA: Not applicable.

  • NA: Not applicable.

2019 CALIFORNIA PLUMBING CODE 111

WATER HEATERS any other purpose or distributed to any other persons or parti es.

TABLE 510.1.2(2) TYPE B DOUBLE-WALL GAS VENT [NFPA 54: TABLE 13.1(b)] (continued)*

NUMBER OF APPLIANCES: SINGLE
**APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** CATEGORY I CATEGORY I CATEGORY I CATEGORY I CATEGORY I
**APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR
VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch) VENT DIAMETER – D (inch)
8 8 8 9 9 9 10 10 10 12 12 12
APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR
HEIGHT
H
(feet)
LATERAL
L
(feet)

FAN FAN NAT FAN FAN NAT FAN FAN NAT FAN FAN NAT
HEIGHT
H
(feet)
LATERAL
L
(feet)

Min

Max

Max

Min

Max

Max

Min

Max

Max

Min

Max

Max

6
0
2
4
6

211
201
237
263

695
423
416
409

369
284
277
271

267
251
295
327

894
541
533
526

469
368
360
352

371
347
409
449

1118
673
664
656

569
453
443
433

537
498
584
638

1639
979
971
962

849
648
638
627

8
0
2
5
8

206
197
245
280

777
482
470
458

414
321
311
300

258
246
305
344

1002
617
604
591

536
417
404
392

360
339
418
470

1257
768
754
740

658
513
500
486

521
486
598
665

1852
1120
1104
1089

967
743
730
715

10
0
2
5
10

202
193
241
296

844
531
518
497

449
354
344
325

253
242
299
363

1093
681
667
643

584
456
443
423

351
332
409
492

1373
849
834
808

718
559
544
520

507
475
584
688

2031
1242
1224
1194

1057
848
825
788

15
0
2
5
10
15

195
187
231
284
334

966
631
616
592
568

523
413
400
381
367

244
232
287
349
404

1259
812
795
768
742

681
543
526
501
484

336
319
392
470
540

1591
1015
997
966
937

838
673
657
628
601

488
457
562
664
750

2374
1491
1469
1433
1399

1237
983
963
928
894

20
0
2
5
10
15
20

190
182
224
277
325
374

1053
708
692
666
640
616

573
468
457
437
419
400

238
227
279
339
393
448

1379
914
896
866
838
810

750
611
596
570
549
526

326
309
381
457
526
592

1751
1146
1126
1092
1060
1028

927
754
734
702
677
651

473
443
547
646
730
808

2631
1689
1665
1626
1587
1550

1346
1098
1074
1037
1005
973

30
0
2
5
10
15
20
30

184
175
215
265
312
360
461

1168
823
806
777
750
723
670

647
533
521
501
481
461
426

229
219
269
327
379
433
541

1542
1069
1049
1017
985
955
895

852
698
684
662
638
615
574

312
296
366
440
507
570
704

1971
1346
1324
1287
1251
1216
1147

1056
863
846
821
794
768
720

454
424
524
620
702
780
937

2996
1999
1971
1927
1884
1841
1759

1545
1308
1283
1243
1205
1166
1101

NUMBER OF APPLIANCES: SINGLE
50
0
2
5
10
15
20
30

176
168
204
253
299
345
442

1292
971
953
923
894
866
809

704
613
602
583
562
543
502

220
209
257
313
363
415
521

1724
1273
1252
1217
1183
1150
1086

948
811
795
765
736
708
649

295
280
347
418
481
544
674

2223
1615
1591
1551
1512
1473
1399

1189
1007
991
963
934
906
848

428
401
496
589
668
741
892

3432
2426
2396
2347
2299
2251
2159

1818
1509
1490
1455
1421
1387
1318

100
0
2
5
10
15
20
30
50
166
158
194
238
281
325
418
617
1404
1152
1134
1104
1075
1046
988
866
765
698
688
672
656
639
NA
NA
207
196
240
293
342
391
491
711
1900
1532
1511
1477
1443
1410
1343
1205
1033
933
921
902
884
864
824
NA
273
259
322
389
447
507
631
895
2479
1970
1945
1905
1865
1825
1747
1591
1300
1168
1153
1133
1110
1087
1041
NA
395
371
460
547
618
690
834
1138
3912
3021
2990
2938
2888
2838
2739
2547
2042
1817
1796
1763
1730
1696
1627
1489
  • NA: Not applicable.

  • NA: Not applicable.

112 2019 CALIFORNIA PLUMBING CODE

WATER HEATERS

TABLE 510.1.2(3) MASONRY CHIMNEY [NFPA 54: TABLE 13.1(c)]*

NUMBER OF APPLIANCES: SINGLE
**APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** CATEGORY I CATEGORY I CATEGORY I CATEGORY I CATEGORY I CATEGORY I
**APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR
TYPE B DOUBLE-WALL CONNECTOR DIAMETER – D (inch)
TO BE USED WITH CHIMNEY AREAS WITHIN THE SIZE LIMITS AT BOTTOM
3 3 3 4 4 4 5 5 5 6 6 6 7 7 7
APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR
HEIGHT
H
(feet)
LATERAL
L
(feet)

FAN FAN NAT FAN FAN NAT FAN FAN NAT FAN FAN NAT FAN FAN NAT
HEIGHT
H
(feet)
LATERAL
L
(feet)

Min

Max

Max

Min

Max

Max

Min

Max

Max

Min

Max

Max

Min

Max

Max

6
2
5

NA
NA

NA
NA

28
25

NA
NA

NA
NA

52
49

NA
NA

NA
NA

86
82

NA
NA

NA
NA

130
117

NA
NA

NA
NA

180
165

8
2
5
8

NA
NA
NA

NA
NA
NA

29
26
24

NA
NA
NA

NA
NA
NA

55
52
48

NA
NA
NA

NA
NA
NA

93
88
83

NA
NA
NA

NA
NA
NA

145
134
127

NA
NA
NA

NA
NA
NA

198
183
175

10
2
5
10

NA
NA
NA

NA
NA
NA

31
28
25

NA
NA
NA

NA
NA
NA

61
57
50

NA
NA
NA

NA
NA
NA

103
96
87

NA
NA
NA

NA
NA
NA

162
148
139

NA
NA
NA

NA
NA
NA

221
204
191

15
2
5
10
15

NA
NA
NA
NA

NA
NA
NA
NA

35
35
28
NA

NA
NA
NA
NA

NA
NA
NA
NA

67
62
55
48

NA
NA
NA
NA

NA
NA
NA
NA

114
107
97
89

NA
NA
NA
NA

NA
NA
NA
NA

179
164
153
141

53
NA
NA
NA

475
NA
NA
NA

250
231
216
201

NUMBER OF APPLIANCES: SINGLE
20
2
5
10
15
20

NA
NA
NA
NA
NA

NA
NA
NA
NA
NA

38
36
NA
NA
NA

NA
NA
NA
NA
NA

NA
NA
NA
NA
NA

74
68
60
NA
NA

NA
NA
NA
NA
NA

NA
NA
NA
NA
NA

124
116
107
97
83

NA
NA
NA
NA
NA

NA
NA
NA
NA
NA

201
184
172
159
148

51
80
NA
NA
NA

522
503
NA
NA
NA

274
254
237
220
206

30
2
5
10
15
20
30

NA
NA
NA
NA
NA
NA

NA
NA
NA
NA
NA
NA

41
NA
NA
NA
NA
NA

NA
NA
NA
NA
NA
NA

NA
NA
NA
NA
NA
NA

82
76
67
NA
NA
NA

NA
NA
NA
NA
NA
NA

NA
NA
NA
NA
NA
NA

137
128
115
107
91
NA

NA
NA
NA
NA
NA
NA

NA
NA
NA
NA
NA
NA

216
198
184
171
159
NA

47
75
NA
NA
NA
NA

581
561
NA
NA
NA
NA

303
281
263
243
227
188

50 2
5
10
15
20
30
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
92
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
161
151
138
127
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
251
230
215
199
185
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
351
323
304
282
264
NA
Minimum
internal area of
chimney
(square inches)
Minimum
internal area of
chimney
(square inches)
12 12 12 19 19 19 28 28 28 38 38 38 50 50 50
Maximum
internal area of
chimney
(square inches)
Maximum
internal area of
chimney
(square inches)
Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.
Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.
Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.
Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.
Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.
Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.
Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.
Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.
Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.
Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.
Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.
Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.
Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.
Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.
Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.
  • NA: Not applicable.

2019 CALIFORNIA PLUMBING CODE 113

WATER HEATERS any other purpose or distributed to any other persons or parti es.

TABLE 510.1.2(3) MASONRY CHIMNEY [NFPA 54: TABLE 13.1(c)] (continued)*

NUMBER OF APPLIANCES: SINGLE
**APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** CATEGORY I CATEGORY I CATEGORY I CATEGORY I CATEGORY I
**APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR
TYPE B DOUBLE-WALL CONNECTOR DIAMETER – D (inch)
TO BE USED WITH CHIMNEY AREAS WITHIN THE SIZE LIMITS AT BOTTOM
8 8 8 9 9 9 10 10 10 12 12 12
APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR
HEIGHT
H
(feet)
LATERAL
L
(feet)

FAN FAN NAT FAN FAN NAT FAN FAN NAT FAN FAN NAT
HEIGHT
H
(feet)
LATERAL
L
(feet)

Min

Max

Max

Min

Max

Max

Min

Max

Max

Min

Max

Max

6
2
5

NA
NA

NA
NA

247
231

NA
NA

NA
NA

320
298

NA
NA

NA
NA

401
376

NA
NA

NA
NA

581
561

8
2
5
8

NA
NA
NA

NA
NA
NA

266
247
239

84
NA
NA

590
NA
NA

350
328
318

100
149
173

728
711
695

446
423
410

139
201
231

1024
1007
990

651
640
623

10
2
5
10

68
NA
NA

519
NA
NA

298
277
263

82
124
155

655
638
610

388
365
347

98
146
182

810
791
762

491
466
444

136
196
240

1144
1124
1093

724
712
668

15
2
5
10
15

64
99
126
NA

613
594
565
NA

336
313
296
281

77
118
148
171

779
759
727
698

441
416
394
375

92
139
173
198

968
946
912
880

562
533
567
485

127
186
229
259

1376
1352
1315
1280

841
828
777
742

20
2
5
10
15
20

61
95
122
NA
NA

678
658
627
NA
NA

375
350
332
314
296

73
113
143
165
186

867
845
811
780
750

491
463
440
418
397

87
133
167
191
214

1083
1059
1022
987
955

627
597
566
541
513

121
179
221
251
277

1548
1523
1482
1443
1406

953
933
879
840
807

30
2
5
10
15
20
30

57
90
115
NA
NA
NA

762
741
709
NA
NA
NA

421
393
373
353
332
288

68
106
135
156
176
NA

985
962
927
893
860
NA

558
526
500
476
450
416

81
125
158
181
203
249

1240
1216
1176
1139
1103
1035

717
683
648
621
592
555

111
169
210
239
264
318

1793
1766
1721
1679
1638
1560

1112
1094
1025
981
940
877

NUMBER OF APPLIANCES: SINGLE
50
2
5
10
15
20
30
51
83
NA
NA
NA
NA
840
819
NA
NA
NA
NA
477
445
424
400
376
327
61
98
126
146
165
NA
1106
1083
1047
1010
977
NA
633
596
567
539
511
468
72
116
147
170
190
233
1413
1387
1347
1307
1269
1196
812
774
733
702
669
623
99
155
195
222
246
295
2080
2052
2006
1961
1916
1832
1243
1225
1147
1099
1050
984
Minimum
internal area of
chimney
(square inches)
Minimum
internal area of
chimney
(square inches)
63 63 63 78 78 78 95 95 95 132 132 132

Maximum
internal area of
chimney
(square inches)

Maximum
internal area of
chimney
(square inches)

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.
  • NA: Not applicable.

  • NA: Not applicable.

114 2019 CALIFORNIA PLUMBING CODE

WATER HEATERS

TABLE 510.1.2(4) MASONRY CHIMNEY [NFPA 54: TABLE 13.1(d)]*

NUMBER OF APPLIANCES: SINGLE
**APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** CATEGORY I CATEGORY I CATEGORY I CATEGORY I CATEGORY I CATEGORY I
**APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR
SINGLE-WALL METAL CONNECTOR DIAMETER– D (inch)
TO BE USED WITH CHIMNEY AREAS WITHIN THE SIZE LIMITS AT BOTTOM
3 3 3 4 4 4 5 5 5 6 6 6 7 7 7
APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR
HEIGHT
H
(feet)
LATERAL
L
(feet)

FAN FAN NAT FAN FAN NAT FAN FAN NAT FAN FAN NAT FAN FAN NAT
HEIGHT
H
(feet)
LATERAL
L
(feet)

Min

Max

Max

Min

Max

Max

Min

Max

Max

Min

Max

Max

Min

Max

Max

6
2
5

NA
NA

NA
NA

28
25

NA
NA

NA
NA

52
48

NA
NA

NA
NA

86
81

NA
NA

NA
NA

130
116

NA
NA

NA
NA

180
164

8
2
5
8

NA
NA
NA

NA
NA
NA

29
26
23

NA
NA
NA

NA
NA
NA

55
51
47

NA
NA
NA

NA
NA
NA

93
87
82

NA
NA
NA

NA
NA
NA

145
133
126

NA
NA
NA

NA
NA
NA

197
182
174

10
2
5
10

NA
NA
NA

NA
NA
NA

31
28
24

NA
NA
NA

NA
NA
NA

61
56
49

NA
NA
NA

NA
NA
NA

102
95
86

NA
NA
NA

NA
NA
NA

161
147
137

NA
NA
NA

NA
NA
NA

220
203
189

15
2
5
10
15

NA
NA
NA
NA

NA
NA
NA
NA

35
32
27
NA

NA
NA
NA
NA

NA
NA
NA
NA

67
61
54
46

NA
NA
NA
NA

NA
NA
NA
NA

113
106
96
87

NA
NA
NA
NA

NA
NA
NA
NA

178
163
151
138

166
NA
NA
NA

473
NA
NA
NA

249
230
214
198

NUMBER OF APPLIANCES: SINGLE
20
2
5
10
15
20

NA
NA
NA
NA
NA

NA
NA
NA
NA
NA

38
35
NA
NA
NA

NA
NA
NA
NA
NA

NA
NA
NA
NA
NA

73
67
59
NA
NA

NA
NA
NA
NA
NA

NA
NA
NA
NA
NA

123
115
105
95
80

NA
NA
NA
NA
NA

NA
NA
NA
NA
NA

200
183
170
156
144

163
NA
NA
NA
NA

520
NA
NA
NA
NA

273
252
235
217
202

30
2
5
10
15
20
30

NA
NA
NA
NA
NA
NA

NA
NA
NA
NA
NA
NA

41
NA
NA
NA
NA
NA

NA
NA
NA
NA
NA
NA

NA
NA
NA
NA
NA
NA

81
75
66
NA
NA
NA

NA
NA
NA
NA
NA
NA

NA
NA
NA
NA
NA
NA

136
127
113
105
88
NA

NA
NA
NA
NA
NA
NA

NA
NA
NA
NA
NA
NA

215
196
182
168
155
NA

158
NA
NA
NA
NA
NA

578
NA
NA
NA
NA
NA

302
279
260
240
223
182

50
2
5
10
15
20
30
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
91
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
160
149
136
124
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
250
228
212
195
180
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
350
321
301
278
258
NA
Minimum
internal area of
chimney
(square inches)
Minimum
internal area of
chimney
(square inches)
12 12 12 19 19 19 28 28 28 38 38 38 50 50 50

Maximum
internal area of
chimney
(square inches)

Maximum
internal area of
chimney
(square inches)

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.
  • NA: Not applicable.

  • NA: Not applicable.

2019 CALIFORNIA PLUMBING CODE 115

WATER HEATERS any other purpose or distributed to any other persons or parti es.

TABLE 510.1.2(4) MASONRY CHIMNEY [NFPA 54: TABLE 13.1(d)] (continued)*

NUMBER OF APPLIANCES: SINGLE
**APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** CATEGORY I CATEGORY I CATEGORY I CATEGORY I CATEGORY I
**APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR
SINGLE-WALL METAL CONNECTOR DIAMETER – D (inch)
TO BE USED WITH CHIMNEY AREAS WITHIN THE SIZE LIMITS AT BOTTOM
8 8 8 9 9 9 10 10 10 12 12 12
APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR
HEIGHT
H
(feet)
LATERAL
L
(feet)

FAN FAN NAT FAN FAN NAT FAN FAN NAT FAN FAN NAT
HEIGHT
H
(feet)
LATERAL
L
(feet)

Min

Max

Max

Min

Max

Max

Min

Max

Max

Min

Max

Max

6
2
5

NA
NA

NA
NA

247
230

NA
NA

NA
NA

319
297

NA
NA

NA
NA

400
375

NA
NA

NA
NA

580
560

8
2
5
8

NA
NA
NA

NA
NA
NA

265
246
237

NA
NA
NA

NA
NA
NA

349
327
317

382
NA
NA

725
NA
NA

445
422
408

549
673
747

1021
1003
985

650
638
621

10
2
5
10

216
NA
NA

518
NA
NA

297
276
261

271
334
NA

654
635
NA

387
364
345

373
459
547

808
789
758

490
465
441

536
657
771

1142
1121
1088

722
710
665

15
2
5
10
15

211
261
NA
NA

611
591
NA
NA

335
312
294
278

264
325
392
452

776
755
722
692

440
414
392
372

362
444
531
606

965
942
907
873

560
531
504
481

520
637
749
841

1373
1348
1309
1272

840
825
774
738

20
2
5
10
15
20

206
255
312
NA
NA

675
655
622
NA
NA

374
348
330
311
292

258
317
382
442
NA

864
842
806
773
NA

490
461
437
414
392

252
433
517
591
663

1079
1055
1016
979
944

625
594
562
539
510

508
623
733
823
911

1544
1518
1475
1434
1394

950
930
875
835
800

NUMBER OF APPLIANCES: SINGLE
30
2
5
10
15
20
30

200
245
300
NA
NA
NA

759
737
703
NA
NA
NA

420
391
370
349
327
281

249
306
370
428
NA
NA

982
958
920
884
NA
NA

556
524
496
471
445
408

340
417
500
572
643
NA

1237
1210
1168
1128
1089
NA

715
680
644
615
585
544

489
600
708
798
883
1055

1789
1760
1713
1668
1624
1539

1110
1090
1020
975
932
865

50
2
5
10
15
20
30
191
NA
NA
NA
NA
NA
837
NA
NA
NA
NA
NA
475
442
420
395
370
318
238
293
355
NA
NA
NA
1103
1078
1038
NA
NA
NA
631
593
562
533
504
458
323
398
447
546
616
NA
1408
1381
1337
1294
1251
NA
810
770
728
695
660
610
463
571
674
761
844
1009
2076
2044
1994
1945
1898
1805
1240
1220
1140
1090
1040
970
Minimum
internal area of
chimney
(square inches)
Minimum
internal area of
chimney
(square inches)
63 63 63 78 78 78 95 95 95 132 132 132

Maximum
internal area of
chimney
(square inches)

Maximum
internal area of
chimney
(square inches)

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.

Seven times the listed appliance categorized vent area, flue collar area, or draft hood outlet areas.
  • NA: Not applicable.

  • NA: Not applicable.

116 2019 CALIFORNIA PLUMBING CODE

WATER HEATERS

TABLE 510.1.2(5) SINGLE-WALL METAL PIPE OR TYPE B ASBESTOS-CEMENT VENT [NFPA 54: TABLE 13.1(e)]*

NUMBER OF APPLIANCES: SINGLE
**APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** DRAFT HOOD-EQUIPPED DRAFT HOOD-EQUIPPED DRAFT HOOD-EQUIPPED
**APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** CONNECTED DIRECTLY TO PIPE OR VENT CONNECTED DIRECTLY TO PIPE OR VENT CONNECTED DIRECTLY TO PIPE OR VENT
DIAMETER – D (inch)
TO BE USED WITH CHIMNEY AREAS WITHIN THE SIZE LIMITS AT BOTTOM
3 4 5 6 7 8 10 12
HEIGHT
H
(feet)
LATERAL
L
(feet)

APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR
HEIGHT
H
(feet)
LATERAL
L
(feet)

MAXIMUM APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR















MAXIMUM APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR















MAXIMUM APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR















MAXIMUM APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR















MAXIMUM APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR















MAXIMUM APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR















MAXIMUM APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR















MAXIMUM APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR















6
0
2
5

39
31
28

70
55
51

116
94
88

170
141
128

232
194
177

312
260
242

500
415
390

750
620
600

8
0
2
5
10

42
32
29
24

76
61
56
49

126
102
95
86

185
154
141
131

252
210
194
180

340
284
264
250

542
451
430
406

815
680
648
625

10
0
2
5
10
15

45
35
32
27
NA

84
67
61
54
46

138
111
104
94
84

202
168
153
143
130

279
233
215
200
186

372
311
289
274
258

606
505
480
455
432

912
760
724
700
666

15
0
2
5
10
15
20

49
39
35
30
NA
NA

91
72
67
58
50
NA

151
122
110
103
93
82

223
186
170
158
144
132

312
260
240
223
207
195

420
350
325
308
291
273

684
570
540
514
488
466

1040
865
825
795
760
726

20
0
2
5
10
15
20

53
42
38
32
NA
NA

101
80
74
65
55
NA

163
136
123
115
104
91

252
210
192
178
163
149

342
286
264
246
228
214

470
392
364
345
326
306

770
641
610
571
550
525

1190
990
945
910
870
832

30
0
2
5
10
15
20
30

56
44
NA
NA
NA
NA
NA

108
84
78
68
NA
NA
NA

183
148
137
125
113
99
NA

276
230
210
196
177
163
NA

384
320
296
274
258
240
192

529
441
410
388
366
344
295

878
730
694
656
625
596
540

1370
1140
1080
1050
1000
960
890

50
0
2
5
10
15
20
30
NA
NA
NA
NA
NA
NA
NA
120
95
NA
NA
NA
NA
NA
210
171
159
146
NA
NA
NA
310
260
234
221
200
185
NA
443
370
342
318
292
276
222
590
492
474
456
407
384
330
980
820
780
730
705
670
605
1550
1290
1230
1190
1130
1080
1010
  • NA: Not applicable.

  • NA: Not applicable.

2019 CALIFORNIA PLUMBING CODE 117

WATER HEATERS any other purpose or distributed to any other persons or parti es.

TABLE 510.1.2(6) EXTERIOR MASONRY CHIMNEY [NFPA 54: TABLE 13.1(f)] 1, 2

NUMBER OF APPLIANCES: SINGLE
**APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** NAT NAT NAT
**APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR
MINIMUM ALLOWABLE INPUT RATING OF SPACE-HEATING APPLIANCE IN THOUSANDS OF BTU PER HOUR
VENT HEIGHT
H
(feet)
INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches)
VENT HEIGHT
H
(feet)
12 19 28
38
50
63
78 113
6
8
10
15
20
30
50
Local 99% winter design temperature: 37°F or greater















Local 99% winter design temperature: 37°F or greater















Local 99% winter design temperature: 37°F or greater















Local 99% winter design temperature: 37°F or greater















Local 99% winter design temperature: 37°F or greater















Local 99% winter design temperature: 37°F or greater















Local 99% winter design temperature: 37°F or greater















Local 99% winter design temperature: 37°F or greater















6
8
10
15
20
30
50
0
0
0
NA
NA
NA
NA
0
0
0
0
NA
NA
NA

0
0
0
0
123
NA
NA

0
0
0
0
190
NA
NA

0
0
0
0
249
NA
NA

0
0
0
0
184
393
NA
0
0
0
0
0
334
NA
0
0
0
0
0
0
579
6
8
10
15
20
30
50
Local 99% winter design temperature: 27°F to 36°F















Local 99% winter design temperature: 27°F to 36°F















Local 99% winter design temperature: 27°F to 36°F















Local 99% winter design temperature: 27°F to 36°F















Local 99% winter design temperature: 27°F to 36°F















Local 99% winter design temperature: 27°F to 36°F















Local 99% winter design temperature: 27°F to 36°F















Local 99% winter design temperature: 27°F to 36°F















6
8
10
15
20
30
50
0
0
0
NA
NA
NA
NA
0
0
51
NA
NA
NA
NA

68
82
97
NA
NA
NA
NA

116
127
141
NA
NA
NA
NA

156
167
183
233
NA
NA
NA

180
187
201
253
307
419
NA
212
214
225
274
330
445
NA
266
263
265
305
362
485
763
6
8
10
15
20
30
50
Local 99% winter design temperature: 17°F to 26°F















Local 99% winter design temperature: 17°F to 26°F















Local 99% winter design temperature: 17°F to 26°F















Local 99% winter design temperature: 17°F to 26°F















Local 99% winter design temperature: 17°F to 26°F















Local 99% winter design temperature: 17°F to 26°F















Local 99% winter design temperature: 17°F to 26°F















Local 99% winter design temperature: 17°F to 26°F















6
8
10
15
20
30
50
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA

NA
NA
NA
NA
NA
NA
NA

NA
NA
NA
NA
NA
NA
NA

NA
197
214
NA
NA
NA
NA

215
226
245
296
352
NA
NA
259
264
278
331
387
507
NA
349
352
358
398
457
581
NA
NUMBER OF APPLIANCES: SINGLE
6
8
10
15
20
30
50
Local 99% winter design temperature: 5°F to 16°F















Local 99% winter design temperature: 5°F to 16°F















Local 99% winter design temperature: 5°F to 16°F















Local 99% winter design temperature: 5°F to 16°F















Local 99% winter design temperature: 5°F to 16°F















Local 99% winter design temperature: 5°F to 16°F















Local 99% winter design temperature: 5°F to 16°F















Local 99% winter design temperature: 5°F to 16°F















6
8
10
15
20
30
50
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA

NA
NA
NA
NA
NA
NA
NA

NA
NA
NA
NA
NA
NA
NA

NA
NA
NA
NA
NA
NA
NA

NA
NA
289
NA
NA
NA
NA
NA
312
331
393
450
NA
NA
416
423
430
485
547
682
972
6
8
10
15
20
30
50
Local 99% winter design temperature: -10°F to 4°F















Local 99% winter design temperature: -10°F to 4°F















Local 99% winter design temperature: -10°F to 4°F















Local 99% winter design temperature: -10°F to 4°F















Local 99% winter design temperature: -10°F to 4°F















Local 99% winter design temperature: -10°F to 4°F















Local 99% winter design temperature: -10°F to 4°F















Local 99% winter design temperature: -10°F to 4°F















6
8
10
15
20
30
50
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA


NA
NA
NA
NA
NA
NA
NA


NA
NA
NA
NA
NA
NA
NA


NA
NA
NA
NA
NA
NA
NA


NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
484
494
513
586
650
805
1003
Local 99% winter design temperature: -11°F or lower
Not recommended for any vent configurations

Notes: 1 See Figure 510.1.10 for a map showing local 99 percent winter design temperatures in the United States. 2 NA: Not applicable.

118 2019 CALIFORNIA PLUMBING CODE

WATER HEATERS

TABLE 510.2(1) TYPE B DOUBLE-WALL VENT [NFPA 54: TABLE 13.2(a)]*

NUMBER OF APPLIANCES: TWO OR MORE
**APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** CATEGORY I CATEGORY I CATEGORY I CATEGORY I CATEGORY I CATEGORY I
**APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR
VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY
TYPE B DOUBLE-WALL VENT AND CONNECTOR DIAMETER – D (inch)
3 3 3 4 4 4 5 5 5 6 6 6 7 7 7
APPLIANCE INPUT RATING LIMITS IN THOUSANDS OF BTU PER HOUR
VENT
HEIGHT
H
(feet)
CONNECTOR
RISE
R
(feet)

FAN FAN NAT FAN FAN NAT FAN FAN NAT FAN FAN NAT FAN FAN NAT
VENT
HEIGHT
H
(feet)
CONNECTOR
RISE
R
(feet)

Min

Max

Max

Min

Max

Max

Min

Max

Max

Min

Max

Max

Min

Max

Max

6
1
2
3

22
23
24

37
41
44

26
31
35

35
37
38

66
75
81

46
55
62

46
48
49

106
121
132

72
86
96

58
60
62

164
183
199

104
124
139

77
79
82

225
253
275

142
168
189

8
1
2
3

22
23
24

40
44
47


27
32
36

35
36
37

72
80
87

48
57
64

49
51
53

114
128
139

76
90
101

64
66
67

176
195
210

109
129
145

84
86
88

243
269
290

148
175
198

10
1
2
3

22
23
24

43
47
50

28
33
37

34
36
37

78
86
92

50
59
67

49
51
52

123
136
146

78
93
104

65
67
69

189
206
220

113
134
150

89
91
94

257
282
303

154
182
205

15
1
2
3

21
22
24

50
53
55

30
35
40

33
35
36

89
96
102

53
63
71

47
49
51

142
153
163

83
99
111

64
66
68

220
235
248

120
142
160

88
91
93

298
320
339

163
193
218

NUMBER OF APPLIANCES: TWO OR MORE
20
1
2
3

21
22
23

54
57
60

31
37
42

33
34
35

99
105
110

56
66
74

46
48
50

157
167
176

87
104
116

62
64
66

246
259
271

125
149
168

86
89
91

334
354
371

171
202
228

30
1
2
3

20
21
22

62
64
66

33
39
44

31
33
34

113
118
123

59
70
79

45
47
48

181
190
198

93
110
124

60
62
64

288
299
309

134
158
178

83
85
88

391
408
423

182
215
242

50
1
2
3

19
21
22

71
73
75

36
43
48

30
32
33

133
137
141

64
76
86

43
45
46

216
223
229

101
119
134

57
59
61

349
358
366

145
172
194

78
81
83

477
490
502

197
234
263

100 1
2
3
18
19
20
82
83
84
37
44
50
28
30
31
158
161
163
66
79
89
40
42
44
262
267
272
104
123
138
53
55
57
442
447
452
150
178
200
73
75
78
611
619
627
204
242
272
50 100 2 3 21 22 64 66 39 44 33 34 118 123 70 79 47 48 190 198 110 124 62 64 299 309 158 178 85 88 408 423 215 242 1 2 3 19 21 22 71 73 75 36 43 48 30 32 33 133 137 141 64 76 86 43 45 46 216 223 229 101 119 134 57 59 61 349 358 366 145 172 194 78 81 83 477 490 502 197 234 263 1 2 3 18 19 20 82 83 84 37 44 50 28 30 31 158 161 163 66 79 89 40 42 44 262 267 272 104 123 138 53 55 57 442 447 452 150 178 200 73 75 78 611 619 627 204 242 272
COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY
TYPE B DOUBLE-WALL COMMON VENT DIAMETER – D (inch)
4 4 4 5 5 5 6 6 6 7 7 7
COMBINED APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR
VENT
HEIGHT
H
(feet)

FAN
+FAN

FAN
+NAT

NAT
+NAT

FAN
+FAN

FAN
+NAT

NAT
+NAT

FAN
+FAN

FAN
+NAT

NAT
+NAT

FAN
+FAN

FAN
+NAT

NAT
+NAT


6
8
10
15
20
30
50
100

92
101
110
125
136
152
167
175

81
90
97
112
123
138
153
163

65
73
79
91
102
118
134
NA

140
155
169
195
215
244
279
311

116
129
141
164
183
210
244
277

103
114
124
144
160
185
214
NA

204
224
243
283
314
361
421
489

161
178
194
228
255
297
353
421

147
163
178
206
229
266
310
NA

309
339
367
427
475
547
641
751
248
275
299
352
394
459
547
658
200
223
242
280
310
360
423
479
  • NA: Not applicable.

  • NA: Not applicable.

2019 CALIFORNIA PLUMBING CODE 119

WATER HEATERS any other purpose or distributed to any other persons or parti es.

TABLE 510.2(1) TYPE B DOUBLE-WALL VENT [NFPA 54: TABLE 13.2(a)] (continued)

NUMBER OF APPLIANCES: TWO OR MORE
**APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** CATEGORY I CATEGORY I CATEGORY I CATEGORY I CATEGORY I
**APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR
VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY
TYPE B DOUBLE-WALL VENT AND CONNECTOR DIAMETER – D (inch)
8 8 8 9 9 9 10 10 10
APPLIANCE INPUT RATING LIMITS IN THOUSANDS OF BTU PER HOUR
VENT
HEIGHT
H
(feet)
CONNECTOR
RISE
R
(feet)

FAN FAN NAT FAN FAN NAT FAN FAN NAT
VENT
HEIGHT
H
(feet)
CONNECTOR
RISE
R
(feet)

Min

Max

Max

Min

Max

Max

Min

Max

Max

6
1
2
3

92
95
97

296
333
363

185
220
248

109
112
114

376
424
463

237
282
317

128
131
134

466
526
575

289
345
386

8
1
2
3

100
103
105

320
356
384

194
230
258

118
121
123

408
454
492

248
294
330

138
141
143

507
564
612

303
358
402

10
1
2
3

106
109
111

341
374
402

200
238
268

125
128
131

436
479
515

257
305
342

146
149
152

542
596
642

314
372
417

15
1
2
3

110
112
115

389
419
445

214
253
286

134
137
140

493
532
565

273
323
365

162
165
167

609
658
700

333
394
444

20
1
2
3

107
110
113

436
463
486

224
265
300

131
134
137

552
587
618

285
339
383

158
161
164

681
725
764

347
414
466

30
1
2
3

103
105
108

512
535
555

238
282
317

125
129
132

649
679
706

305
360
405

151
155
158

802
840
874

372
439
494

50
1
2
3

97
100
103

627
645
661

257
306
343

120
123
126

797
820
842

330
392
441

144
148
151

984
1014
1043

403
478
538

100 1
2
3
91
94
97
810
822
834
266
316
355
112
115
118
1038
1054
1069
341
405
455
135
139
142
1285
1306
1327
417
494
555

120 2019 CALIFORNIA PLUMBING CODE

WATER HEATERS

TABLE 510.2(1) TYPE B DOUBLE-WALL VENT [NFPA 54: TABLE 13.2(a)] (continued)*

NUMBER OF APPLIANCES: TWO OR MORE
**APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** CATEGORY I CATEGORY I CATEGORY I CATEGORY I CATEGORY I
**APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR
VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY
TYPE B DOUBLE-WALL VENT AND CONNECTOR DIAMETER – D (inch)
12 12 12 14 14 14 16 16 16 18 18 18
APPLIANCE INPUT RATING LIMITS IN THOUSANDS OF BTU PER HOUR
VENT
HEIGHT
H
(feet)
CONNECTOR
RISE
R
(feet)

FAN FAN NAT FAN FAN NAT FAN FAN NAT FAN FAN NAT
VENT
HEIGHT
H
(feet)
CONNECTOR
RISE
R
(feet)

Min

Max

Max

Min

Max

Max

Min

Max

Max

Min

Max

Max

6
2
4
6

174
180
NA

764
897
NA

496
616
NA

223
230
NA

1046
1231
NA

653
827
NA

281
287
NA

1371
1617
NA

853
1081
NA

346
352
NA

1772
2069
NA

1080
1370
NA

8
2
4
6

186
192
198

822
952
1050

516
644
772

238
244
252

1126
1307
1445

696
884
1072

298
305
313

1478
1719
1902

910
1150
1390

365
372
380

1920
2211
2434

1150
1460
1770

10
2
4
6

196
201
207

870
997
1095

536
664
792

249
256
263

1195
1371
1509

730
924
1118

311
318
325

1570
1804
1989

955
1205
1455

379
387
395

2049
2332
2556

1205
1535
1865

15
2
4
6

214
221
228

967
1085
1181

568
712
856

272
279
286

1334
1499
1632

790
1006
1222

336
344
351

1760
1978
2157

1030
1320
1610

408
416
424

2317
2579
2796

1305
1665
2025

20
2
4
6

223
230
237

1051
1162
1253

596
748
900

291
298
307

1443
1597
1726

840
1064
1288

357
365
373

1911
2116
2287

1095
1395
1695

430
438
450

2533
2778
2984

1385
1765
2145

30
2
4
6

216
223
231

1217
1316
1400

632
792
952

286
294
303

1664
1802
1920

910
1160
1410

367
376
384

2183
2366
2524

1190
1510
1830

461
474
485

2891
3110
3299

1540
1920
2340

50
2
4
6

206
213
221

1479
1561
1631

689
860
1031

273
281
290

2023
2139
2242

1007
1291
1575

350
359
369

2659
2814
2951

1315
1685
2055

435
447
461

3548
3730
3893

1665
2135
2605

NUMBER OF APPLIANCES: TWO OR MORE
100 2
4
6
192
200
208
1923
1984
2035
712
888
1064
254
263
272
2644
2731
2811
1050
1346
1642
326
336
346
3490
3606
3714
1370
1760
2150
402
414
426
4707
4842
4968
1740
2220
2700
50 100 4 6 223 231 1316 1400 792 952 294 303 1802 1920 1160 1410 376 384 2366 2524 1510 1830 474 485 3110 3299 1920 2340 2 4 6 206 213 221 1479 1561 1631 689 860 1031 273 281 290 2023 2139 2242 1007 1291 1575 350 359 369 2659 2814 2951 1315 1685 2055 435 447 461 3548 3730 3893 1665 2135 2605 2 4 6 192 200 208 1923 1984 2035 712 888 1064 254 263 272 2644 2731 2811 1050 1346 1642 326 336 346 3490 3606 3714 1370 1760 2150 402 414 426 4707 4842 4968 1740 2220 2700
COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY
TYPE B DOUBLE-WALL COMMON VENT DIAMETER – D (inch)
12 12 12 14 14 14 16 16 16 18 18 18
COMBINED APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR
VENT
HEIGHT
H
(feet)

FAN
+FAN

FAN
+NAT

NAT
+NAT

FAN
+FAN

FAN
+NAT

NAT
+NAT

FAN
+FAN

FAN
+NAT

NAT
+NAT

FAN
+FAN

FAN
+NAT

NAT
+NAT


6
8
10
15
20
30
50
100

900
994
1076
1247
1405
1658
2024
2569

696
773
841
986
1116
1327
1640
2131

588
652
712
825
916
1025
1280
1670

1284
1423
1542
1794
2006
2373
2911
3732

990
1103
1200
1410
1588
1892
2347
3076

815
912
995
1158
1290
1525
1863
2450

1735
1927
2093
2440
2722
3220
3964
5125

1336
1491
1625
1910
2147
2558
3183
4202

1065
1190
1300
1510
1690
1990
2430
3200

2253
2507
2727
3184
3561
4197
5184
6749
1732
1936
2113
2484
2798
3326
4149
5509
1345
1510
1645
1910
2140
2520
3075
4050
  • NA: Not applicable.

  • NA: Not applicable.

2019 CALIFORNIA PLUMBING CODE 121

WATER HEATERS any other purpose or distributed to any other persons or parti es.

TABLE 510.2(1) TYPE B DOUBLE-WALL VENT [NFPA 54: TABLE 13.2(a)] (continued)*

NUMBER OF APPLIANCES: TWO OR MORE
**APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** CATEGORY I CATEGORY I CATEGORY I CATEGORY I
**APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR
VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY
TYPE B DOUBLE-WALL VENT AND CONNECTOR DIAMETER – D (inch)
20 20 20 22 22 22 24 24 24
APPLIANCE INPUT RATING LIMITS IN THOUSANDS OF BTU PER HOUR
VENT
HEIGHT
H
(feet)
CONNECTOR
RISE
R
(feet)

FAN FAN NAT FAN FAN NAT FAN FAN NAT
VENT
HEIGHT
H
(feet)
CONNECTOR
RISE
R
(feet)

Min

Max

Max

Min

Max

Max

Min

Max

Max

6
2
4
6

NA
NA
NA

NA
NA
NA

NA
NA
NA

NA
NA
NA

NA
NA
NA

NA
NA
NA

NA
NA
NA

NA
NA
NA

NA
NA
NA

8
2
4
6

NA
471
478

NA
2737
3018

NA
1800
2180

NA
560
568

NA
3319
3665

NA
2180
2640

NA
662
669

NA
3957
4373

NA
2590
3130

10
2
4
6

NA
486
494

NA
2887
3169

NA
1890
2290

NA
581
589

NA
3502
3849

NA
2280
2760

NA
686
694

NA
4175
4593

NA
2710
3270

15
2
4
6

NA
523
533

NA
3197
3470

NA
2060
2510

NA
624
634

NA
3881
4216

NA
2490
3030

NA
734
743

NA
4631
5035

NA
2960
3600

20
2
4
6

NA
554
567

NA
3447
3708

NA
2180
2650

NA
661
671

NA
4190
4511

NA
2630
3190

NA
772
785

NA
5005
5392

NA
3130
3790

30
2
4
6

NA
619
632

NA
3840
4080

NA
2365
2875

NA
728
741

NA
4861
4976

NA
2860
3480

NA
847
860

NA
5606
5961

NA
3410
4150

50
2
4
6

NA
580
594

NA
4601
4808

NA
2633
3208

NA
709
724

NA
5569
5826

NA
3185
3885

NA
851
867

NA
6633
6943

NA
3790
4620

100 2
4
6
NA
523
539
NA
5982
6143
NA
2750
3350
NA
639
654
NA
7254
7453
NA
3330
4070
NA
769
786
NA
8650
8892
NA
3950
4810
  • NA: Not applicable.

  • NA: Not applicable.

122 2019 CALIFORNIA PLUMBING CODE

WATER HEATERS

TABLE 510.2(2) TYPE B DOUBLE-WALL VENT [NFPA 54: TABLE 13.2(b)]*

NUMBER OF APPLIANCES: TWO OR MORE
**APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** CATEGORY I CATEGORY I CATEGORY I CATEGORY I CATEGORY I CATEGORY I
**APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR
VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY
SINGLE-WALL METAL VENT CONNECTOR DIAMETER – D (inch)
3 3 3 4 4 4 5 5 5 6 6 6 7 7 7
APPLIANCE INPUT RATING LIMITS IN THOUSANDS OF BTU PER HOUR
VENT
HEIGHT
H
(feet)
CONNECTOR
RISE
R
(feet)

FAN FAN NAT FAN FAN NAT FAN FAN NAT FAN FAN NAT FAN FAN NAT
VENT
HEIGHT
H
(feet)
CONNECTOR
RISE
R
(feet)

Min

Max

Max

Min

Max

Max

Min

Max

Max

Min

Max

Max

Min

Max

Max

6
1
2
3

NA
NA
NA

NA
NA
NA

26
31
34

NA
NA
NA

NA
NA
NA

46
55
62

NA
NA
121

NA
NA
131

71
85
95

NA
168
175

NA
182
198

102
123
138

207
215
222

223
251
273

140
167
188

8
1
2
3

NA
NA
NA

NA
NA
NA

27
32
35

NA
NA
NA

NA
NA
NA

48
57
64

NA
125
130

NA
126
138

75
89
100

NA
184
191

NA
193
208

106
127
144

226
234
241

240
266
287

145
173
197

10
1
2
3

NA
NA
NA

NA
NA
NA

28
33
36

NA
84
89

NA
85
91

50
59
67

119
124
129

121
134
144

77
91
102

182
189
197

186
203
217

110
132
148

240
248
257

253
278
299

150
183
203

15
1
2
3

NA
NA
NA

NA
NA
NA

29
34
39

79
83
87

87
94
100

52
62
70

116
121
127

138
150
160

81
97
109

177
185
193

214
230
243

116
138
157

238
246
255

291
314
333

158
189
215

NUMBER OF APPLIANCES: TWO OR MORE
20
1
2
3

49
52
55

56
59
62

30
36
40

78
82
87

97
103
107

54
64
72

115
120
125

152
163
172

84
101
113

175
182
190

238
252
264

120
144
164

233
243
252

325
346
363

165
197
223

30
1
2
3

47
51
54

60
62
64

31
37
42

77
81
85

110
115
119

57
67
76

112
117
122

175
185
193

89
106
120

169
177
185

278
290
300

129
152
172

226
236
244

380
397
412

175
208
235

50
1
2
3

46
49
52

69
71
72

34
40
45

75
79
83

128
132
136

60
72
82

109
114
119

207
215
221

96
113
123

162
170
178

336
345
353

137
164
186

217
226
235

460
473
486

188
223
252

100 1
2
3
45
48
51
79
80
81
34
41
46
71
75
79
150
153
157
61
73
85
104
110
114
249
255
260
98
115
129
153
160
168
424
428
433
140
167
190
205
212
222
585
593
603
192
228
256
50 100 2 3 51 54 62 64 37 42 81 85 115 119 67 76 117 122 185 193 106 120 177 185 290 300 152 172 236 244 397 412 208 235 1 2 3 46 49 52 69 71 72 34 40 45 75 79 83 128 132 136 60 72 82 109 114 119 207 215 221 96 113 123 162 170 178 336 345 353 137 164 186 217 226 235 460 473 486 188 223 252 1 2 3 45 48 51 79 80 81 34 41 46 71 75 79 150 153 157 61 73 85 104 110 114 249 255 260 98 115 129 153 160 168 424 428 433 140 167 190 205 212 222 585 593 603 192 228 256
COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY
TYPE B DOUBLE-WALL COMMON VENT DIAMETER – D (inch)
4 4 4 5 5 5 6 6 6 7 7 7
COMBINED APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR
VENT
HEIGHT
H
(feet)

FAN
+FAN

FAN
+NAT

NAT
+NAT

FAN
+FAN

FAN
+NAT

NAT
+NAT

FAN
+FAN

FAN
+NAT

NAT
+NAT

FAN
+FAN

FAN
+NAT

NAT
+NAT

6
8
10
15
20
30
50
100
NA
NA
NA
121
131
145
159
166
78
87
94
108
118
132
145
153
64
71
76
88
98
113
128
NA
NA
NA
163
189
208
236
268
297
113
126
137
159
177
202
233
263
99
111
120
140
156
180
208
NA
200
218
237
275
305
350
406
469
158
173
189
221
247
286
337
398
144
159
174
200
223
257
296
NA
304
331
357
416
463
533
622
726
244
269
292
343
383
446
529
633
196
218
236
274
302
349
410
464
  • NA: Not applicable.

  • NA: Not applicable.

2019 CALIFORNIA PLUMBING CODE 123

WATER HEATERS any other purpose or distributed to any other persons or parti es.

TABLE 510.2(2) TYPE B DOUBLE-WALL VENT [NFPA 54: TABLE 13.2(b)] (continued)
**NUMBER OF APPLIANCES: ** **NUMBER OF APPLIANCES: ** **NUMBER OF APPLIANCES: ** **NUMBER OF APPLIANCES: ** TWO OR MORE TWO OR MORE TWO OR MORE TWO OR MORE
**APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** CATEGORY I CATEGORY I CATEGORY I CATEGORY I
**APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR
VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY
SINGLE-WALL METAL VENT CONNECTOR DIAMETER – D (inch)
8 8 8 9 9 9 10 10 10
APPLIANCE INPUT RATING LIMITS IN THOUSANDS OF BTU PER HOUR
VENT
HEIGHT
H
(feet)
CONNECTOR
RISE
R
(feet)

FAN FAN NAT FAN FAN NAT FAN FAN NAT
VENT
HEIGHT
H
(feet)
CONNECTOR
RISE
R
(feet)

Min

Max

Max

Min

Max

Max

Min

Max

Max

6
1
2
3

262
271
279

293
331
361

183
219
247

325
334
344

373
422
462

234
281
316

447
458
468

463
524
574

286
344
385

8
1
2
3

285
293
302


316
353
381

191
228
256

352
360
370

403
450
489

244
292
328

481
492
501

502
560
609

299
355
400

10
1
2
3

302
311
320

335
369
398

196
235
265

372
381
391

429
473
511

252
302
339

506
517
528

534
589
637

308
368
413

15
1
2
3

312
321
331

380
411
438

208
248
281

397
407
418

482
522
557

266
317
360

556
568
579

596
646
690

324
387
437

20
1
2
3

306
317
326

425
453
476

217
259
294

390
400
412

538
574
607

276
331
375

546
558
570

664
709
750

336
403
457

30
1
2
3

296
307
316

497
521
542

230
274
309

378
389
400

630
662
690

294
349
394

528
541
555

779
819
855

358
425
482

50
1
2
3

284
294
304

604
623
640

245
293
331

364
376
387

768
793
816

314
375
423

507
520
535

951
983
1013

384
458
518

100 1
2
3
269
279
289
774
788
801
249
299
339
345
358
368
993
1011
1027
321
383
431
476
490
506
1236
1259
1280
393
469
527
50 100 2 3 307 316 521 542 274 309 389 400 662 690 349 394 541 555 819 855 425 482 1 2 3 284 294 304 604 623 640 245 293 331 364 376 387 768 793 816 314 375 423 507 520 535 951 983 1013 384 458 518 1 2 3 269 279 289 774 788 801 249 299 339 345 358 368 993 1011 1027 321 383 431 476 490 506 1236 1259 1280 393 469 527
COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY
TYPE B DOUBLE-WALL COMMON VENT DIAMETER – D (inch)
8 8 8 9 9 9 10 10 10
COMBINED APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR
VENT
HEIGHT
H
(feet)

FAN
+FAN

FAN
+NAT

NAT
+NAT

FAN
+FAN

FAN
+NAT

NAT
+NAT

FAN
+FAN

FAN
+NAT

NAT
+NAT

6
8
10
15
20
30
50
100
398
436
467
544
606
703
833
999
310
342
369
434
487
570
686
846
257
285
309
357
395
459
535
606
541
592
638
738
824
958
1139
1378
429
473
512
599
673
790
954
1185
332
373
398
456
512
593
689
780
665
730
787
905
1013
1183
1418
1741
515
569
617
718
808
952
1157
1459
407
460
487
553
626
723
838
948

124 2019 CALIFORNIA PLUMBING CODE

WATER HEATERS

TABLE 510.2(3) MASONRY CHIMNEY [NFPA 54: TABLE 13.2(c)]*

NUMBER OF APPLIANCES: TWO OR MORE
**APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** CATEGORY I CATEGORY I CATEGORY I CATEGORY I CATEGORY I CATEGORY I
**APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR
VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY
TYPE B DOUBLE-WALL VENT CONNECTOR DIAMETER – D (inch)
3 3 3 4 4 4 5 5 5 6 6 6 7 7 7
APPLIANCE INPUT RATING LIMITS IN THOUSANDS OF BTU PER HOUR
VENT
HEIGHT
H
(feet)
CONNECTOR
RISE
R
(feet)

FAN FAN NAT FAN FAN NAT FAN FAN NAT FAN FAN NAT FAN FAN NAT
VENT
HEIGHT
H
(feet)
CONNECTOR
RISE
R
(feet)

Min

Max

Max

Min

Max

Max

Min

Max

Max

Min

Max

Max

Min

Max

Max

6
1
2
3

24
26
27

33
43
49

21
28
34

39
41
42

62
79
92

40
52
61

52
53
55

106
133
155

67
85
97

65
67
69

194
230
262

101
124
143

87
89
91

274
324
369

141
173
203

8
1
2
3

24
26
27

39
47
52

22
29
34

39
40
42

72
87
97

41
53
62

55
57
59

117
140
159

69
86
98

71
73
75

213
246
269

105
127
145

94
97
99

304
350
383

148
179
206

10
1
2
3

24
26
27

42
50
55

22
29
35

38
40
41

80
93
105

42
54
63

55
57
58

130
153
170

71
87
100

74
76
78

232
261
284

108
129
148

101
103
106

324
366
397

153
184
209

15
1
2
3

24
25
26

48
55
59

23
31
35

38
39
41

93
105
115

44
55
64

54
56
57

154
174
189

74
89
102

72
74
76

277
299
319

114
134
153

100
103
105

384
419
448

164
192
215

NUMBER OF APPLIANCES: TWO OR MORE
20
1
2
3

24
25
26

52
58
63

24
31
35

37
39
40

102
114
123

46
56
65

53
55
57

172
190
204

77
91
104

71
73
75

313
335
353

119
138
157

98
101
104

437
467
493

173
199
222

30
1
2
3

24
25
26

54
60
64

25
32
36

37
38
40

111
122
131

48
58
66

52
54
56

192
208
221

82
95
107

69
72
74

357
376
392

127
145
163

96
99
101

504
531
554

187
209
233

50
1
2
3

23
24
26

51
59
64

25
32
36

36
37
39

116
127
135

51
61
69

51
53
55

209
225
237

89
102
115

67
70
72

405
421
435

143
161
180

92
95
98

582
604
624

213
235
260

100 1
2
3
23
24
25
46
53
59
24
31
35
35
37
38
108
120
130
50
60
68
49
51
53
208
224
237
92
105
118
65
67
69
428
444
458
155
174
193
88
92
94
640
660
679
237
260
285
50 100 2 3 25 26 60 64 32 36 38 40 122 131 58 66 54 56 208 221 95 107 72 74 376 392 145 163 99 101 531 554 209 233 1 2 3 23 24 26 51 59 64 25 32 36 36 37 39 116 127 135 51 61 69 51 53 55 209 225 237 89 102 115 67 70 72 405 421 435 143 161 180 92 95 98 582 604 624 213 235 260 1 2 3 23 24 25 46 53 59 24 31 35 35 37 38 108 120 130 50 60 68 49 51 53 208 224 237 92 105 118 65 67 69 428 444 458 155 174 193 88 92 94 640 660 679 237 260 285
COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY
MINIMUM INTERNAL AREA OF MASONRY CHIMNEY FLUE (square inches)
12 12 12 19 19 19 28 28 28 38 38 38 50 50 50
COMBINED APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR
VENT
HEIGHT
H
(feet)

FAN
+FAN

FAN
+NAT

NAT
+NAT

FAN
+FAN

FAN
+NAT

NAT
+NAT

FAN
+FAN

FAN
+NAT

NAT
+NAT

FAN
+FAN

FAN
+NAT

NAT
+NAT

FAN
+FAN

FAN
+NAT

NAT
+NAT

6
8
10
15
20
30
50
100
NA
NA
NA
NA
NA
NA
NA
NA
74
80
84
NA
NA
NA
NA
NA
25
28
31
36
41
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
119
130
138
152
NA
NA
NA
NA
46
53
56
67
75
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
178
193
207
233
250
270
NA
NA
71
82
90
106
122
137
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
257
279
299
334
368
404
NA
NA
103
119
131
152
172
198
NA
NA
NA
NA
NA
523
565
615
NA
NA
351
384
409
467
508
564
620
NA
143
163
177
212
243
278
328
348
  • NA: Not applicable.

  • NA: Not applicable.

2019 CALIFORNIA PLUMBING CODE 125

WATER HEATERS any other purpose or distributed to any other persons or parti es.

TABLE 510.2(3) MASONRY CHIMNEY [NFPA 54: TABLE 13.2(c)] (continued)*

NUMBER OF APPLIANCES: TWO OR MORE
**APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** CATEGORY I CATEGORY I CATEGORY I CATEGORY I
**APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR
VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY
TYPE B DOUBLE-WALL VENT CONNECTOR DIAMETER – D (inch)
8 8 8 9 9 9 10 10 10
APPLIANCE INPUT RATING LIMITS IN THOUSANDS OF BTU PER HOUR
VENT
HEIGHT
H
(feet)
CONNECTOR
RISE
R
(feet)

FAN FAN NAT FAN FAN NAT FAN FAN NAT
VENT
HEIGHT
H
(feet)
CONNECTOR
RISE
R
(feet)

Min

Max

Max

Min

Max

Max

Min

Max

Max

6
1
2
3

104
107
109

370
436
491

201
232
270

124
127
129

479
562
633

253
300
349

145
148
151

599
694
795

319
378
439

8
1
2
3

113
116
119

414
473
517

210
240
276

134
137
139

539
615
672

267
311
358

156
160
163

682
776
848

335
394
452

10
1
2
3

120
123
126

444
498
540

216
247
281

142
145
147

582
652
705

277
321
366

165
168
171

739
825
893

348
407
463

15
1
2
3

125
128
131

511
558
597

229
260
292

153
156
159

658
718
760

297
339
382

184
187
190

824
900
960

375
432
486

20
1
2
3

123
126
129

584
625
661

239
270
301

150
153
156

752
805
851

312
354
396

180
184
187

943
1011
1067

397
452
505

30
1
2
3

119
122
125

680
715
746

255
287
317

145
149
152

883
928
968

337
378
418

175
179
182

1115
1171
1220

432
484
535

50
1
2
3

115
118
121

798
827
854

294
326
357

140
143
147

1049
1085
1118

392
433
474

168
172
176

1334
1379
1421

506
558
611

100 1
2
3
109
113
116
907
933
956
334
368
399
134
138
141
1222
1253
1282
454
497
540
161
165
169
1589
1626
1661
596
651
705
50 100 2 3 122 125 715 746 287 317 149 152 928 968 378 418 179 182 1171 1220 484 535 1 2 3 115 118 121 798 827 854 294 326 357 140 143 147 1049 1085 1118 392 433 474 168 172 176 1334 1379 1421 506 558 611 1 2 3 109 113 116 907 933 956 334 368 399 134 138 141 1222 1253 1282 454 497 540 161 165 169 1589 1626 1661 596 651 705
COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY
MINIMUM INTERNAL AREA OF MASONRY CHIMNEY FLUE (square inches)
63 63 63 78 78 78 113 113 113
COMBINED APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR
VENT
HEIGHT
H
(feet)

FAN
+FAN

FAN
+NAT

NAT
+NAT

FAN
+FAN

FAN
+NAT

NAT
+NAT

FAN
+FAN

FAN
+NAT

NAT
+NAT

6
8
10
15
20
30
50
100
NA
NA
606
682
742
816
879
NA
458
501
538
611
668
747
831
NA
188
218
236
283
325
381
461
499
NA
724
776
874
955
1062
1165
NA
582
636
686
781
858
969
1089
NA
246
278
302
365
419
496
606
669
1041
1144
1226
1374
1513
1702
1905
2053
853
937
1010
1156
1286
1473
1692
1921
NA
408
454
546
648
749
922
1058
  • NA: Not applicable.

  • NA: Not applicable.

126 2019 CALIFORNIA PLUMBING CODE

WATER HEATERS

TABLE 510.2(4) MASONRY CHIMNEY [NFPA 54: TABLE 13.2(d)]*

NUMBER OF APPLIANCES: TWO OR MORE
**APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** CATEGORY I CATEGORY I CATEGORY I CATEGORY I CATEGORY I CATEGORY I
**APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR
VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY
SINGLE-WALL METAL VENT CONNECTOR DIAMETER– D (inch)
3 3 3 4 4 4 5 5 5 6 6 6 7 7 7
APPLIANCE INPUT RATING LIMITS IN THOUSANDS OF BTU PER HOUR
VENT
HEIGHT
H
(feet)
CONNECTOR
RISE
R
(feet)

FAN FAN NAT FAN FAN NAT FAN FAN NAT FAN FAN NAT FAN FAN NAT
VENT
HEIGHT
H
(feet)
CONNECTOR
RISE
R
(feet)

Min

Max

Max

Min

Max

Max

Min

Max

Max

Min

Max

Max

Min

Max

Max

6
1
2
3

NA
NA
NA

NA
NA
NA

21
28
34

NA
NA
NA

NA
NA
NA

39
52
61

NA
NA
134

NA
NA
153

66
84
97

179
186
193

191
227
258

100
123
142

231
239
247

271
321
365

140
172
202

8
1
2
3

NA
NA
NA

NA
NA
NA

21
28
34

NA
NA
NA

NA
NA
NA

40
52
62

NA
137
143

NA
139
156

68
85
98

195
202
210

208
240
264

103
125
145

250
258
266

298
343
376

146
177
205

10
1
2
3

NA
NA
NA

NA
NA
NA

22
29
34

NA
NA
97

NA
NA
102

41
53
62

130
136
143

151
150
166

70
86
99

202
210
217

225
255
277

106
128
147

267
276
284

316
358
389

151
181
207

15
1
2
3

NA
NA
NA

NA
NA
NA

23
30
34

NA
92
96

NA
103
112

43
54
63

129
135
141

151
170
185

73
88
101

199
207
215

271
295
315

112
132
151

268
277
286

376
411
439

161
189
213

NUMBER OF APPLIANCES: TWO OR MORE
20
1
2
3

NA
NA
NA

NA
NA
NA

23
30
35

87
91
96

99
111
119

45
55
64

128
134
140

167
185
199

76
90
103

197
205
213

303
325
343

117
136
154

265
274
282

425
455
481

169
195
219

30
1
2
3

NA
NA
NA

NA
NA
NA

24
31
35

86
91
95

108
119
127

47
57
65

126
132
138

187
203
216

80
93
105

193
201
209

347
366
381

124
142
160

259
269
277

492
518
540

183
205
229

50
1
2
3

NA
NA
NA

NA
NA
NA

24
31
35

85
89
94

113
123
131

50
60
68

124
130
136

204
218
231

87
100
112

188
196
205

392
408
422

139
158
176

252
262
271

567
588
607

208
230
255

100 1
2
3
NA
NA
NA
NA
NA
NA
23
30
34
84
88
93
104
115
124
49
59
67
122
127
133
200
215
228
89
102
115
182
190
199
410
425
438
151
169
188
243
253
262
617
636
654
232
254
279
50 100 2 3 NA NA NA NA 31 35 91 95 119 127 57 65 132 138 203 216 93 105 201 209 366 381 142 160 269 277 518 540 205 229 1 2 3 NA NA NA NA NA NA 24 31 35 85 89 94 113 123 131 50 60 68 124 130 136 204 218 231 87 100 112 188 196 205 392 408 422 139 158 176 252 262 271 567 588 607 208 230 255 1 2 3 NA NA NA NA NA NA 23 30 34 84 88 93 104 115 124 49 59 67 122 127 133 200 215 228 89 102 115 182 190 199 410 425 438 151 169 188 243 253 262 617 636 654 232 254 279
COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY COMMON VENT CAPACITY
MINIMUM INTERNAL AREA OF MASONRY CHIMNEY FLUE (square inches)
12 12 12 19 19 19 28 28 28 38 38 38 50 50 50
COMBINED APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR
VENT
HEIGHT
H
(feet)

FAN
+FAN

FAN
+NAT

NAT
+NAT

FAN
+FAN

FAN
+NAT

NAT
+NAT

FAN
+FAN

FAN
+NAT

NAT
+NAT

FAN
+FAN

FAN
+NAT

NAT
+NAT

FAN
+FAN

FAN
+NAT

NAT
+NAT

6
8
10
15
20
30
50
100
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
25
28
31
36
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
118
128
136
NA
NA
NA
NA
NA
45
52
56
66
74
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
176
190
205
230
247
NA
NA
NA
71
81
89
105
120
135
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
255
276
295
335
362
398
NA
NA
102
118
129
150
170
195
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
348
380
405
400
503
558
612
NA
142
162
175
210
240
275
325
NA
  • NA: Not applicable.

  • NA: Not applicable.

2019 CALIFORNIA PLUMBING CODE 127

WATER HEATERS any other purpose or distributed to any other persons or parti es.

TABLE 510.2(4) MASONRY CHIMNEY [NFPA 54: TABLE 13.2(d)] (continued)*

NUMBER OF APPLIANCES: TWO OR MORE
**APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** **APPLIANCE TYPE: ** CATEGORY I CATEGORY I CATEGORY I CATEGORY I
**APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR SINGLE-WALL METAL CONNECTOR
VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY VENT CONNECTOR CAPACITY
SINGLE-WALL METAL VENT CONNECTOR DIAMETER – D (inch)
8 8 8 9 9 9 10 10 10
APPLIANCE INPUT RATING LIMITS IN THOUSANDS OF BTU PER HOUR
VENT
HEIGHT
H
(feet)
CONNECTOR
RISE
R
(feet)

FAN FAN NAT FAN FAN NAT FAN FAN NAT
VENT
HEIGHT
H
(feet)
CONNECTOR
RISE
R
(feet)

Min

Max

Max

Min

Max

Max

Min

Max

Max

6
1
2
3

292
301
309

366
432
491

200
231
269

362
373
381

474
557
634

252
299
348

499
509
519

594
696
793

316
376
437

8
1
2
3

313
323
332

407
465
509

207
238
274

387
397
407

530
607
663

263
309
356

529
540
551

672
766
838

331
391
450

10
1
2
3

333
343
352

434
489
530

213
244
279

410
420
430

571
640
694

273
317
363

558
569
580

727
813
880

343
403
459

15
1
2
3

349
359
368

502
548
586

225
256
289

445
456
466

646
706
755

291
334
378

623
634
646

808
884
945

366
424
479

20
1
2
3

345
355
365

569
610
644

235
266
298

439
450
461

734
787
831

306
348
391

614
627
639

921
986
1042

387
443
496

30
1
2
3

338
348
358

665
699
729

250
282
312

430
442
452

864
908
946

330
372
412

600
613
626

1089
1145
1193

421
473
524

50
1
2
3

328
339
349

778
806
831

287
320
351

417
429
440

1022
1058
1090

383
425
466

582
596
610

1302
1346
1386

492
545
597

100 1
2
3
315
326
337
875
899
921
328
361
392
402
415
427
1181
1210
1238
444
488
529
560
575
589
1537
1570
1604
580
634
687
  • NA: Not applicable.

  • NA: Not applicable.

128 2019 CALIFORNIA PLUMBING CODE

WATER HEATERS

TABLE 510.2(5) SINGLE-WALL METAL PIPE OR TYPE B ASBESTOS-CEMENT VENT [NFPA 54: TABLE 13.2(e)]*

NUMBER OF APPLIANCES: TWO OR MORE
**APPLIANCE TYPE: ** DRAFT HOOD-EQUIPMENT DRAFT HOOD-EQUIPMENT DRAFT HOOD-EQUIPMENT
**APPLIANCE VENT CONNECTION: ** DIRECT TO PIPE OR VENT DIRECT TO PIPE OR VENT DIRECT TO PIPE OR VENT
VENT CONNECTOR CAPACITY
VENT CONNECTOR DIAMETER – D (inch) VENT CONNECTOR DIAMETER – D (inch)
TOTAL VENT CONNECTOR CONNECTOR 3 4
5
6
7 8
HEIGHT
H
(feet)
6-8
15
30
and up
RISE
R
(feet)
1
2
3
1
2
3
1
2
3
21
28
34
23
30
35
25
31
36
APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR
40
53
61
68
86
98
102
124
147
146
178
204
44
56
64
77
92
102
117
134
155
179
194
216
49
58
68
84
97
107
129
145
164
190
211
232
APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR
40
53
61
68
86
98
102
124
147
146
178
204
44
56
64
77
92
102
117
134
155
179
194
216
49
58
68
84
97
107
129
145
164
190
211
232
205
235
275
240
265
298
270
295
321
COMMON VENT CAPACITY
COMMON VENT DIAMETER – D (inch)
TOTAL VENT 4 5 6
7
8
10 12
HEIGHT
H
(feet)
6
8
10
15
20
30
50
48
55
59
71
80
NA
NA
COMBINED
78
89
95
115
129
147
NA
COMBINED
78
89
95
115
129
147
NA
** APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR**
111
128
136
168
186
215
NA
155
175
190
228
260
300
360
205
234
250
305
340
400
490
320
365
395
480
550
650
810
** APPLIANCE INPUT RATING IN THOUSANDS OF BTU PER HOUR**
111
128
136
168
186
215
NA
155
175
190
228
260
300
360
205
234
250
305
340
400
490
320
365
395
480
550
650
810
NA
505
560
690
790
940
1190
  • NA: Not applicable.

  • NA: Not applicable.

TABLE 510.2(6) EXTERIOR MASONRY CHIMNEY [NFPA 54: TABLE 13.2(f)]*

NUMBER OF APPLIANCES: TWO OR MORE
**APPLIANCE TYPE: ** **APPLIANCE TYPE: ** NAT + NAT NAT + NAT NAT + NAT
**APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR
COMBINED APPLIANCE MAXIMUM INPUT RATING IN THOUSANDS OF BTU PER HOUR
VENT HEIGHT
H
(feet)

INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches)
VENT HEIGHT
H
(feet)

12

19

28

38

50

63

78

113

6
8
10
15
20
30
50
100
25
28
31
NA
NA
NA
NA
NA
46
53
56
67
NA
NA
NA
NA
71
82
90
106
NA
NA
NA
NA
103
119
131
152
NA
NA
NA
NA
143
163
177
212
NA
NA
NA
NA
188
218
236
283
325
NA
NA
NA
246
278
302
365
419
496
NA
NA
NA
408
454
546
648
749
922
NA
  • NA: Not applicable.

  • NA: Not applicable.

2019 CALIFORNIA PLUMBING CODE 129

WATER HEATERS any other purpose or distributed to any other persons or parti es.

TABLE 510.2(7) EXTERIOR MASONRY CHIMNEY [NFPA 54: TABLE 13.2(g)]1, 2 2
**NUMBER OF APPLIANCES: ** **NUMBER OF APPLIANCES: ** TWO OR MORE TWO OR MORE TWO OR MORE
**APPLIANCE TYPE: ** **APPLIANCE TYPE: ** NAT + NAT NAT + NAT NAT + NAT
**APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR
MINIMUM ALLOWABLE INPUT RATING OF SPACE-HEATING APPLIANCE IN THOUSANDS OF BTU PER HOUR
VENT HEIGHT
H
(feet)
INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches)
VENT HEIGHT
H
(feet)
12 19
28
38
50
63
78 113


















6
8
10
15
20
30
50
100
0
0
0
NA
NA
NA
NA
NA

0
0
0
0
NA
NA
NA
NA

0
0
0
0
NA
NA
NA
NA

0
0
0
0
NA
NA
NA
NA

0
0
0
0
NA
NA
NA
NA

0
0
0
0
184
393
NA
NA
0
0
0
0
0
334
NA
NA
NA
0
0
0
0
0
579
NA


















6
8
10
15
20
30
50
100
0
0
0
NA
NA
NA
NA
NA

0
0
51
NA
NA
NA
NA
NA

68
82
NA
NA
NA
NA
NA
NA

NA
NA
NA
NA
NA
NA
NA
NA

NA
NA
NA
NA
NA
NA
NA
NA

180
187
201
253
307
NA
NA
NA
212
214
225
274
330
445
NA
NA
NA
263
265
305
362
485
763
NA


















6
8
10
15
20
30
50
100
NA
NA
NA
NA
NA
NA
NA
NA

NA
NA
NA
NA
NA
NA
NA
NA

NA
NA
NA
NA
NA
NA
NA
NA

NA
NA
NA
NA
NA
NA
NA
NA

NA
NA
NA
NA
NA
NA
NA
NA

NA
NA
NA
NA
NA
NA
NA
NA
NA
264
278
331
387
NA
NA
NA
NA
352
358
398
457
581
862
NA


















TABLE 510.2(7) EXTERIOR MASONRY CHIMNEY [NFPA 54: TABLE 13.2(g)]1, 2 2
6
8
10
15
20
30
50
100
NA
NA
NA
NA
NA
NA
NA
NA

NA
NA
NA
NA
NA
NA
NA
NA


NA
NA
NA
NA
NA
NA
NA
NA


NA
NA
NA
NA
NA
NA
NA
NA


NA
NA
NA
NA
NA
NA
NA
NA


NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
430
485
547
682
NA
NA
Local 99% winter design temperature: 4°F or lower
Not recommended for any vent configurations

Notes: 1 See Figure 510.1.10 for a map showing local 99 percent winter design temperatures in the United States. 2 NA: Not applicable.

130 2019 CALIFORNIA PLUMBING CODE

WATER HEATERS

TABLE 510.2(8) EXTERIOR MASONRY CHIMNEY [NFPA 54: TABLE 13.2(h)]*

**NUMBER OF APPLIANCES: ** **NUMBER OF APPLIANCES: ** TWO OR MORE TWO OR MORE TWO OR MORE
**APPLIANCE TYPE: ** **APPLIANCE TYPE: ** FAN + NAT FAN + NAT FAN + NAT
**APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR
COMBINED APPLIANCE MAXIMUM INPUT RATING IN THOUSANDS OF BTU PER HOUR
VENT HEIGHT
H
(feet)

INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches)
VENT HEIGHT
H
(feet)

12

19

28

38

50

63

78

113

6
8
10
15
20
30
50
100
74
80
84
NA
NA
NA
NA
NA
119
130
138
152
NA
NA
NA
NA
178
193
207
233
250
NA
NA
NA
257
279
299
334
368
404
NA
NA
351
384
409
467
508
564
NA
NA
458
501
538
611
668
747
831
NA
582
636
686
781
858
969
1089
NA
853
937
1010
1156
1286
1473
1692
1921
  • NA: Not applicable.

  • NA: Not applicable.

2019 CALIFORNIA PLUMBING CODE 131

WATER HEATERS any other purpose or distributed to any other persons or parti es.

TABLE 510.2(9) EXTERIOR MASONRY CHIMNEY [NFPA 54: TABLE 13.2(i)]1, , 2
**NUMBER OF APPLIANCES: ** **NUMBER OF APPLIANCES: ** TWO OR MORE TWO OR MORE TWO OR MORE
**APPLIANCE TYPE: ** **APPLIANCE TYPE: ** FAN + NAT FAN + NAT FAN + NAT
**APPLIANCE VENT CONNECTION: ** **APPLIANCE VENT CONNECTION: ** TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR TYPE B DOUBLE-WALL CONNECTOR
MINIMUM ALLOWABLE INPUT RATING OF SPACE-HEATING APPLIANCE IN THOUSANDS OF BTU PER HOUR
VENT HEIGHT
H
(feet)
INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches) INTERNAL AREA OF CHIMNEY (square inches)
VENT HEIGHT
H
(feet)
12 19
28
38
50
63
78 113


















6
8
10
15
20
30
50
100
0
0
0
NA
NA
NA
NA
NA

0
0
0
0
NA
NA
NA
NA

0
0
0
0
123
NA
NA
NA

0
0
0
0
190
334
NA
NA

0
0
0
0
249
398
NA
NA

0
0
0
0
184
393
714
NA
0
0
0
0
0
334
707
NA
0
0
0
0
0
0
579
1600


















6
8
10
15
20
30
50
100
0
0
0
NA
NA
NA
NA
NA

0
0
51
111
NA
NA
NA
NA

68
82
97
142
187
NA
NA
NA

116
127
141
183
230
330
NA
NA

156
167
183
233
284
319
NA
NA

180
187
201
253
307
419
672
NA
212
214
225
274
330
445
705
NA
266
263
265
305
362
485
763
1554


















6
8
10
15
20
30
50
100
0
52
NA
NA
NA
NA
NA
NA

55
74
90
NA
NA
NA
NA
NA

99
111
125
167
212
NA
NA
NA

141
154
169
212
258
362
NA
NA

182
197
214
263
316
429
NA
NA

215
226
245
296
352
470
723
NA
259
264
278
331
387
507
766
NA
349
352
358
398
457
581
862
1669


















TABLE 510.2(9) EXTERIOR MASONRY CHIMNEY [NFPA 54: TABLE 13.2(i)]1, , 2
6
8
10
15
20
30
50
100
NA
NA
NA
NA
NA
NA
NA
NA

78
94
111
NA
NA
NA
NA
NA

121
135
149
193
NA
NA
NA
NA

166
182
198
247
293
377
NA
NA

214
230
250
305
360
450
NA
NA

252
269
289
346
408
531
797
NA
301
312
331
393
450
580
853
NA
416
423
430
485
547
682
972
1833


















6
8
10
15
20
30
50
100
NA
NA
NA
NA
NA
NA
NA
NA

NA
NA
NA
NA
NA
NA
NA
NA


145
159
175
NA
NA
NA
NA
NA


196
213
231
283
333
NA
NA
NA


249
269
292
351
408
NA
NA
NA


296
320
339
404
468
603
NA
NA
349
371
397
457
528
667
955
NA
484
494
513
586
650
805
1003
NA
Local 99% winter design temperature: -11°F or lower
Not recommended for any vent configurations

Notes: 1 See Figure 510.1.10 for a map showing local 99 percent winter design temperatures in the United States. 2 NA: Not applicable.

132 2019 CALIFORNIA PLUMBING CODE

CALIFORNIA PLUMBING CODE – MATRIX ADOPTION TABLE

Get a plain-English answer with a citation back to this text.

Ask AI about this code
Contents — California Plumbing Code (Title 24, Part 5)
California Plumbing Code (Title 24, Part 5)
  1. Chapter 1 — GENERAL CODE PROVISIONS
  2. Chapter 2 — DEFINITIONS
  3. Chapter 3 — GENERAL REGULATIONS
  4. Chapter 4 — PLUMBING FIXTURES AND FIXTURE FITTINGS
  5. Chapter 5 — WATER HEATERS
    Overview
    1. 501.0 General.501.1 Applicability. The regulations of this cha…
    2. 503.2 Final Water Heater Inspection. This inspection
    3. 504.2 Vent. Water heaters of other than the direct-vent type
    4. 504.3 Clearance. The clearance requirements for water
    5. 504.4 Pressure-Limiting Devices. A water heater installation s…
    6. 504.5 Temperature-Limiting Devices. A water heater
    7. 504.6 Temperature, Pressure, and Vacuum Relief
    8. 505.2 Safety Devices. Storage-type water heaters and hot
    9. 505.3 Oil-Fired Water Heaters. Oil-fired water heaters
    10. 505.4 Indirect-Fired Water Heaters. Indirect-fired water
    11. 506.0 Air for Combustion and Ventilation.506.1 General. Air fo…
    12. 506.2 Indoor Combustion Air. The required volume of
    13. 506.4 Outdoor Combustion Air. Outdoor combustion air
    14. 506.3 Indoor Opening Size and Location. Openings
    15. 506.8 Louvers, Grilles, and Screens. The required size
    16. 506.5 Combination Indoor and Outdoor CombustionAir. The use of…
    17. 506.9 Combustion Air Ducts. Combustion air ducts shall
    18. 506.6 Engineered Installations. Engineered combustion
    19. 506.7 Mechanical Combustion Air Supply. Where
    20. 507.2 Seismic Provisions. Water heaters shall be
    21. 507.3 Appliance Support. Appliances and equipment shall
    22. 507.4 Ground Support. A water heater supported from the
    23. 507.5 Drainage Pan. Where a water heater is located in an
    24. 507.6 Added or Converted Equipment or Appliances. When additio…
    25. 507.7 Types of Gases. The appliance shall be connected to
    26. 507.8 Safety Shutoff Devices for Unlisted LP-GasAppliance Used…
    27. 507.9 Use of Air or Oxygen Under Pressure. Where air
    28. 507.10 Protection of Gas Appliances from Fumes orGases other t…
    29. 507.11 Process Air. In addition to air needed for combustion i…
    30. 507.12 Flammable Vapors. Appliances shall not be
    31. 507.13 Installation in Residential Garages. Appliances
    32. 507.14 Installation in Commercial Garages. Appliances
    33. 507.15 Installation in Aircraft Hangars. Heaters in aircraft h…
    34. 507.16 Venting of Flue Gases. Appliances shall be vented
    35. 507.17 Extra Device or Attachment. No device or attachment sha…
    36. 507.18 Adequate Capacity of Piping. When additional
    37. 507.19 Avoiding Strain on Gas Piping. Appliances shall
    38. 507.20 Gas Appliance Pressure Regulators. Where the
    39. 507.21 Venting of Gas Appliance Pressure Regula-tors. Venting …
    40. 507.22 Bleed Lines for Diaphragm-Type Valves. Bleed
    41. 507.23 Combination of Appliances and Equipment. A
    42. 507.24 Installation Instructions. The installing agency
    43. 507.25 Protection of Outdoor Appliances. Appliances
    44. 507.26 Accessibility for Service. Appliances shall be
    45. 507.27 Clearance to Combustible Materials. Appliances and thei…
    46. 508.0 Appliances on Roofs.508.1 General. Appliances on roofs s…
    47. 508.2 Installation of Appliances on Roofs. Appliances
    48. 508.3 Appliances on Roofs. Appliances located on roofs
    49. 508.4 Appliances in Attics and Under-Floor Spaces.
    50. 509.2 Connection to Venting Systems. Except as permitted in Se…
    51. 509.3 Design and Construction. Venting systems shall
    52. 509.4 Type of Venting System to be Used. The type of
    53. 509.5 Masonry, Metal, and Factory-Built Chimneys.
    54. 509.6 Gas Vents. The installation of gas vents shall meet
    55. 509.7 Single-Wall Metal Pipe. Single-wall metal pipe
    56. 509.8 Through-the-Wall Vent Termination. A mechanical draft ve…
    57. 509.9 Condensation Drain. Provision shall be made to
    58. 509.11 Vent Connectors for Category II, Category III,
    59. 509.12 Draft Hoods and Draft Controls. Vented appliances shall…
    60. 509.15 Obstructions. Devices that retard the flow of vent
    61. 509.13 Manually Operated Dampers. A manually operated damper s…
    62. 509.14 Automatically Operated Vent Dampers. An
    63. 510.1 Single Appliance Vent Table 510.1.2(1) through
    64. 510.2 Multiple Appliance Vent Table 510.2(1) throughTable 510.…
  6. Chapter 6 — WATER SUPPLY AND DISTRIBUTION
  7. Chapter 7 — SANITARY DRAINAGE
  8. Chapter 8 — INDIRECT WASTES
  9. Chapter 9 — VENTS
  10. Chapter 10 — TRAPS AND INTERCEPTORS
  11. Chapter 11 — STORM DRAINAGE
  12. Chapter 12 — FUEL GAS PIPING
  13. Chapter 13 — HEALTH CARE FACILITIES AND MEDICAL GAS AND MEDICA…
  14. Chapter 14 — FIRESTOP PROTECTION
  15. Chapter 15 — ALTERNATE WATER SOURCES FOR NONPOTABLE APPLICATIONS
  16. Chapter 16 — NONPOTABLE RAINWATER CATCHMENT SYSTEMS
  17. Chapter 17 — REFERENCED STANDARDS
  18. Appendix A — RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYS…
  19. Appendix B — EXPLANATORY NOTES ON COMBINATION WASTE AND VENT S…
  20. Appendix C — ALTERNATE PLUMBING SYSTEMS
  21. Appendix D — SIZING STORM WATER DRAINAGE SYSTEMS
  22. Appendix E — MANUFACTURED/MOBILE HOME PARKS AND RECREATIONAL V…
  23. Appendix F — FIREFIGHTER BREATHING AIR REPLENISHMENT SYSTEMS
  24. Appendix G — SIZING OF VENTING SYSTEMS
  25. Appendix H — PRIVATE SEWAGE DISPOSAL SYSTEMS
  26. Appendix I — INSTALLATION STANDARD FOR PEX TUBING SYSTEMS FOR …
  27. Appendix J — COMBINATION OF INDOOR AND OUTDOOR COMBUSTION AND …
  28. Appendix K — POTABLE RAINWATER CATCHMENT SYSTEMS
  29. Appendix L — SUSTAINABLE PRACTICES
  30. Appendix M — PEAK WATER DEMAND CALCULATOR

GoCodebook provides public access, search, citation, multilingual explanation, and practical interpretation of legally adopted building regulations. It is not a substitute for the official ICC or California code publications.