Chapter 4 — PLUMBING FIXTURES AND FIXTURE FITTINGS

2025 California Plumbing Code (Title 24, Part 5) · 2025 edition · updated 2026-07-27 · California

Italicized text is a California amendment to the model code, as printed in the official publication.

(Matrix Adoption Tables are non-regulatory, intended only as an aid to the code user. See Chapter 1 for state agency authority and building applications.)

Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
BSC BSC-
CG
SFM HCD DSA OSHPD BSCC DPH AGR DWR CEC CA SL SLC
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
BSC BSC-
CG
SFM 1 2 1-AC AC ** SS** SS/CC 1 1R 2 3 4 5 6 6 6 6 6 6 6 6 6
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X X X X X X X X X X X X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X X X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X X X X X X X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
BSC BSC-
CG
SFM HCD DSA OSHPD BSCC DPH AGR DWR CEC CA SL SLC
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
BSC BSC-
CG
SFM HCD DSA OSHPD BSCC DPH AGR DWR CEC CA SL SLC
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
BSC BSC-
CG
SFM HCD DSA OSHPD BSCC DPH AGR DWR CEC CA SL SLC
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X X X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X X X X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
BSC BSC-
CG
SFM HCD DSA OSHPD BSCC DPH AGR DWR CEC CA SL SLC
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
Note Under Chapter Title
401.3
403.1
403.2
403.3
407.2
407.2.1
407.2.2
407.2.3
407.2.4
407.2.4.1
408.3
408.3.1
408.3.2
408.6
408.7 Exception 1
411.2
411.2.2
411.2.2.1
411.2.3
411.2.4
412.1
412.1.1
412.1.2
412.1.3
412.1.4.1
413.2
415.1
417.1.1
417.1.2
420.2.1
420.2.2
X

), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.

CALIFORNIA PLUMBING CODE – MATRIX ADOPTION TABLE

CHAPTER 4 - PLUMBING FIXTURES AND FIXTURE FITTINGS (continued) (Matrix Adoption Tables are non-regulatory, intended only as an aid to the code user. See Chapter 1 for state agency authority and building applications.)

Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
422.1
422.1 Exception
Table 422.1
422.1.1
422.1.3
422.1.4
422.2
422.2 Exceptions
422.2 Exception (4)
422.3.1 & Exception
422.4
422.5
422.6 Exception (3)
422.7 Exception (2)
422.8
422.9
422.10
422.11
Table 4-1
Table 4-2
Table 4-3
Table 4-4
BSC BSC-
CG
SFM HCD DSA OSHPD BSCC DPH AGR DWR CEC CA SL SLC
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
422.1
422.1 Exception
Table 422.1
422.1.1
422.1.3
422.1.4
422.2
422.2 Exceptions
422.2 Exception (4)
422.3.1 & Exception
422.4
422.5
422.6_Exception (3)
422.7_Exception (2)

422.8
422.9
422.10
422.11
Table 4-1
Table 4-2
Table 4-3
Table 4-4
BSC BSC-
CG
SFM 1 2 1-AC AC ** SS** SS/CC 1 1R 2 3 4 5 6 6 6 6 6 6 6 6 6
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
422.1
422.1 Exception
Table 422.1
422.1.1
422.1.3
422.1.4
422.2
422.2 Exceptions
422.2 Exception (4)
422.3.1 & Exception
422.4
422.5
422.6_Exception (3)
422.7_Exception (2)

422.8
422.9
422.10
422.11
Table 4-1
Table 4-2
Table 4-3
Table 4-4
X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
422.1
422.1 Exception
Table 422.1
422.1.1
422.1.3
422.1.4
422.2
422.2 Exceptions
422.2 Exception (4)
422.3.1 & Exception
422.4
422.5
422.6_Exception (3)
422.7_Exception (2)

422.8
422.9
422.10
422.11
Table 4-1
Table 4-2
Table 4-3
Table 4-4
X X X X X X X X X X X X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
422.1
422.1 Exception
Table 422.1
422.1.1
422.1.3
422.1.4
422.2
422.2 Exceptions
422.2 Exception (4)
422.3.1 & Exception
422.4
422.5
422.6_Exception (3)
422.7_Exception (2)

422.8
422.9
422.10
422.11
Table 4-1
Table 4-2
Table 4-3
Table 4-4
X X X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
422.1
422.1 Exception
Table 422.1
422.1.1
422.1.3
422.1.4
422.2
422.2 Exceptions
422.2 Exception (4)
422.3.1 & Exception
422.4
422.5
422.6_Exception (3)
422.7_Exception (2)

422.8
422.9
422.10
422.11
Table 4-1
Table 4-2
Table 4-3
Table 4-4
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
422.1
422.1 Exception
Table 422.1
422.1.1
422.1.3
422.1.4
422.2
422.2 Exceptions
422.2 Exception (4)
422.3.1 & Exception
422.4
422.5
422.6_Exception (3)
422.7_Exception (2)

422.8
422.9
422.10
422.11
Table 4-1
Table 4-2
Table 4-3
Table 4-4
X X X X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
422.1
422.1 Exception
Table 422.1
422.1.1
422.1.3
422.1.4
422.2
422.2 Exceptions
422.2 Exception (4)
422.3.1 & Exception
422.4
422.5
422.6_Exception (3)
422.7_Exception (2)

422.8
422.9
422.10
422.11
Table 4-1
Table 4-2
Table 4-3
Table 4-4
X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
422.1
422.1 Exception
Table 422.1
422.1.1
422.1.3
422.1.4
422.2
422.2 Exceptions
422.2 Exception (4)
422.3.1 & Exception
422.4
422.5
422.6_Exception (3)
422.7_Exception (2)

422.8
422.9
422.10
422.11
Table 4-1
Table 4-2
Table 4-3
Table 4-4
X X X X X X X X X X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
422.1
422.1 Exception
Table 422.1
422.1.1
422.1.3
422.1.4
422.2
422.2 Exceptions
422.2 Exception (4)
422.3.1 & Exception
422.4
422.5
422.6_Exception (3)
422.7_Exception (2)

422.8
422.9
422.10
422.11
Table 4-1
Table 4-2
Table 4-3
Table 4-4
X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
422.1
422.1 Exception
Table 422.1
422.1.1
422.1.3
422.1.4
422.2
422.2 Exceptions
422.2 Exception (4)
422.3.1 & Exception
422.4
422.5
422.6 Exception (3)
422.7 Exception (2)
422.8
422.9
422.10
422.11
Table 4-1
Table 4-2
Table 4-3
Table 4-4
BSC BSC-
CG
SFM HCD DSA OSHPD BSCC DPH AGR DWR CEC CA SL SLC
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
422.1
422.1 Exception
Table 422.1
422.1.1
422.1.3
422.1.4
422.2
422.2 Exceptions
422.2 Exception (4)
422.3.1 & Exception
422.4
422.5
422.6_Exception (3)
422.7_Exception (2)

422.8
422.9
422.10
422.11
Table 4-1
Table 4-2
Table 4-3
Table 4-4
X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
422.1
422.1 Exception
Table 422.1
422.1.1
422.1.3
422.1.4
422.2
422.2 Exceptions
422.2 Exception (4)
422.3.1 & Exception
422.4
422.5
422.6_Exception (3)
422.7_Exception (2)

422.8
422.9
422.10
422.11
Table 4-1
Table 4-2
Table 4-3
Table 4-4
X X X X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
422.1
422.1 Exception
Table 422.1
422.1.1
422.1.3
422.1.4
422.2
422.2 Exceptions
422.2 Exception (4)
422.3.1 & Exception
422.4
422.5
422.6_Exception (3)
422.7_Exception (2)

422.8
422.9
422.10
422.11
Table 4-1
Table 4-2
Table 4-3
Table 4-4
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
422.1
422.1 Exception
Table 422.1
422.1.1
422.1.3
422.1.4
422.2
422.2 Exceptions
422.2 Exception (4)
422.3.1 & Exception
422.4
422.5
422.6_Exception (3)
422.7_Exception (2)

422.8
422.9
422.10
422.11
Table 4-1
Table 4-2
Table 4-3
Table 4-4
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
422.1
422.1 Exception
Table 422.1
422.1.1
422.1.3
422.1.4
422.2
422.2 Exceptions
422.2 Exception (4)
422.3.1 & Exception
422.4
422.5
422.6_Exception (3)
422.7_Exception (2)

422.8
422.9
422.10
422.11
Table 4-1
Table 4-2
Table 4-3
Table 4-4
X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
422.1
422.1 Exception
Table 422.1
422.1.1
422.1.3
422.1.4
422.2
422.2 Exceptions
422.2 Exception (4)
422.3.1 & Exception
422.4
422.5
422.6_Exception (3)
422.7_Exception (2)

422.8
422.9
422.10
422.11
Table 4-1
Table 4-2
Table 4-3
Table 4-4
X X X X X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
422.1
422.1 Exception
Table 422.1
422.1.1
422.1.3
422.1.4
422.2
422.2 Exceptions
422.2 Exception (4)
422.3.1 & Exception
422.4
422.5
422.6_Exception (3)
422.7_Exception (2)

422.8
422.9
422.10
422.11
Table 4-1
Table 4-2
Table 4-3
Table 4-4
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
422.1
422.1 Exception
Table 422.1
422.1.1
422.1.3
422.1.4
422.2
422.2 Exceptions
422.2 Exception (4)
422.3.1 & Exception
422.4
422.5
422.6_Exception (3)
422.7_Exception (2)

422.8
422.9
422.10
422.11
Table 4-1
Table 4-2
Table 4-3
Table 4-4
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
422.1
422.1 Exception
Table 422.1
422.1.1
422.1.3
422.1.4
422.2
422.2 Exceptions
422.2 Exception (4)
422.3.1 & Exception
422.4
422.5
422.6_Exception (3)
422.7_Exception (2)

422.8
422.9
422.10
422.11
Table 4-1
Table 4-2
Table 4-3
Table 4-4
X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
422.1
422.1 Exception
Table 422.1
422.1.1
422.1.3
422.1.4
422.2
422.2 Exceptions
422.2 Exception (4)
422.3.1 & Exception
422.4
422.5
422.6 Exception (3)
422.7 Exception (2)
422.8
422.9
422.10
422.11
Table 4-1
Table 4-2
Table 4-3
Table 4-4
BSC BSC-
CG
SFM HCD DSA OSHPD BSCC DPH AGR DWR CEC CA SL SLC
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
422.1
422.1 Exception
Table 422.1
422.1.1
422.1.3
422.1.4
422.2
422.2 Exceptions
422.2 Exception (4)
422.3.1 & Exception
422.4
422.5
422.6_Exception (3)
422.7_Exception (2)

422.8
422.9
422.10
422.11
Table 4-1
Table 4-2
Table 4-3
Table 4-4
X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
422.1
422.1 Exception
Table 422.1
422.1.1
422.1.3
422.1.4
422.2
422.2 Exceptions
422.2 Exception (4)
422.3.1 & Exception
422.4
422.5
422.6_Exception (3)
422.7_Exception (2)

422.8
422.9
422.10
422.11
Table 4-1
Table 4-2
Table 4-3
Table 4-4
X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
422.1
422.1 Exception
Table 422.1
422.1.1
422.1.3
422.1.4
422.2
422.2 Exceptions
422.2 Exception (4)
422.3.1 & Exception
422.4
422.5
422.6_Exception (3)
422.7_Exception (2)

422.8
422.9
422.10
422.11
Table 4-1
Table 4-2
Table 4-3
Table 4-4
X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
422.1
422.1 Exception
Table 422.1
422.1.1
422.1.3
422.1.4
422.2
422.2 Exceptions
422.2 Exception (4)
422.3.1 & Exception
422.4
422.5
422.6_Exception (3)
422.7_Exception (2)

422.8
422.9
422.10
422.11
Table 4-1
Table 4-2
Table 4-3
Table 4-4
X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
422.1
422.1 Exception
Table 422.1
422.1.1
422.1.3
422.1.4
422.2
422.2 Exceptions
422.2 Exception (4)
422.3.1 & Exception
422.4
422.5
422.6_Exception (3)
422.7_Exception (2)

422.8
422.9
422.10
422.11
Table 4-1
Table 4-2
Table 4-3
Table 4-4
X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
422.1
422.1 Exception
Table 422.1
422.1.1
422.1.3
422.1.4
422.2
422.2 Exceptions
422.2 Exception (4)
422.3.1 & Exception
422.4
422.5
422.6_Exception (3)
422.7_Exception (2)

422.8
422.9
422.10
422.11
Table 4-1
Table 4-2
Table 4-3
Table 4-4
X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
422.1
422.1 Exception
Table 422.1
422.1.1
422.1.3
422.1.4
422.2
422.2 Exceptions
422.2 Exception (4)
422.3.1 & Exception
422.4
422.5
422.6_Exception (3)
422.7_Exception (2)

422.8
422.9
422.10
422.11
Table 4-1
Table 4-2
Table 4-3
Table 4-4
X X X X X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
422.1
422.1 Exception
Table 422.1
422.1.1
422.1.3
422.1.4
422.2
422.2 Exceptions
422.2 Exception (4)
422.3.1 & Exception
422.4
422.5
422.6_Exception (3)
422.7_Exception (2)

422.8
422.9
422.10
422.11
Table 4-1
Table 4-2
Table 4-3
Table 4-4
X
Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
422.1
422.1 Exception
Table 422.1
422.1.1
422.1.3
422.1.4
422.2
422.2 Exceptions
422.2 Exception (4)
422.3.1 & Exception
422.4
422.5
422.6_Exception (3)
422.7_Exception (2)

422.8
422.9
422.10
422.11
Table 4-1
Table 4-2
Table 4-3
Table 4-4
X

This state agency does not adopt sections identified with the following symbol: The Office of the State Fire Marshal’s adoption of this chapter or individual sections is applicable to structures regulated by other state agencies pursuant to Section 1.11.0.

58 2025 CALIFORNIA PLUMBING CODE

), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.

CHAPTER 4

PLUMBING FIXTURES AND FIXTURE FITTINGS

Note: In addition to the requirements of this chapter, buildings or facilities where accessibility is required for applications listed in California Code of Regulations, Title 24, Part 2 (California Building Code), Chapter 1, Section 1.9.1 regulated by the Division of the State Architect–Access Compliance shall also comply with Title 24, Part 2, Chapter 11A or 11B, as applicable under authority cited by CA Government Code Section 4450 and in reference cited by CA Government Code Sections 4450 through 4461, 12955.1(c), and CA Health and Safety Code Sections 18949.1, 19952 through 19959.

401.0 General.

401.1 Applicability. This chapter shall govern the materials

and installation of plumbing fixtures, including faucets and fixture fittings, and the minimum number of plumbing fixtures required based on occupancy.

401.2 Quality of Fixtures.

Plumbing fixtures shall be constructed of dense, durable, non-absorbent materials and shall have smooth, impervious surfaces, free from unnecessary concealed fouling surfaces.

401.3 Water-Conserving Fixtures and Fittings.

Note 1: [BSC-CG & DSA-SS] Flow rates for specified plumbing fixtures for mandatory nonresidential construction are contained in Chapter 5, Division 5.3 of the California Green Building Standards Code (Part 11, Title 24, Califor- nia Code of Regulations - CALGreen). Scoping provisions applicable to nonresidential additions and alterations are contained in Section 301.3 of CALGreen. Note 2: [BSC-CG] On and after January 1, 2014, certain commercial real property, as defined in Civil Code Section 1101.3, shall have its noncompliant plumbing fixtures replaced with appropriate water-conserving plumbing fix- tures under specific circumstances. See Civil Code Section

1101.1 et seq. for definitions, types of commercial real prop-

erty affected, effective dates, circumstances necessitating replacement of noncompliant plumbing fixtures, and duties and responsibilities for ensuring compliance.

[HCD-1] All noncompliant plumbing fixtures in any residen- tial real property shall be replaced with water-conserving plumbing fixtures. Plumbing fixture replacement is required prior to issuance of a certificate of final completion, certificate of occupancy, or final permit approval by the local building department. See Civil Code Section 1101.1, et seq., for the def- inition of a noncompliant plumbing fixture, types of residential buildings affected and other important enactment dates. Note 3: [OSHPD 1, 2, 3 & 4] Also refer to Title 20, Cali- fornia Code of Regulations, Division 2, Chapter 4, Article 4, Section 1605.3 (i). Note 4: Appliance Efficiency Regulations – Water Effi- ciency. [CEC] Where California law in Title 20 Sections 1601 et seq. applying to water-using appliances sold or offered for sale within the state specifies a lower maximum flow rate than specified in Section 407.2, 408.3, or 411.2, the lower maximum flow rate shall be required.

402.0 Installation.

402.1 Cleaning. Plumbing fixtures shall be installed in a

manner to afford easy access for repairs and cleaning. Pipes from fixtures shall be run to the nearest wall.

402.2 Joints. Where a fixture comes in contact with the wall

or floor, the joint between the fixture and the wall or floor shall be made watertight.

402.3 Securing Fixtures. Floor-outlet or floor-mounted

fixtures shall be rigidly secured to the drainage connection and to the floor, where so designed, by screws or bolts of copper, copper alloy, or other equally corrosion-resistant material.

402.4 Wall-Hung Fixtures. Wall-hung fixtures shall be

rigidly supported by metal supporting members so that no strain is transmitted to the connections. Floor-affixed supports for off-the-floor plumbing fixtures for public use shall comply with ASME A112.6.1M. Framing-affixed supports for off-thefloor water closets with concealed tanks shall comply with ASME A112.6.2. Flush tanks and similar appurtenances shall be secured by approved non-corrosive screws or bolts.

402.5 Setting.

Fixtures shall be set level and in proper alignment with reference to adjacent walls. No water closet or bidet shall be set closer than 15 inches (381 mm) from its center to a side wall or obstruction or closer than 30 inches (762 mm) center to center to a similar fixture. The clear space in front of a water closet, lavatory, or bidet shall be not less than 24 inches (610 mm). No urinal shall be set closer than 12 inches (305 mm) from its center to a side wall or partition or closer than 24 inches (610 mm) center to center.

Exception: The installation of paper dispensers or accessibility grab bars shall not be considered obstructions.

402.6 Flanged Fixture Connections.

Fixture connections between drainage pipes and water closets, floor outlet service sinks and urinals shall be made using an approved copper alloy, hard lead, ABS, PVC, or iron flanges caulked, soldered, solvent cemented; rubber compression gaskets; or screwed to the drainage pipe. The connection shall be bolted with an approved gasket, washer, or setting compound between the fixture and the connection. The bottom of the flange shall be set on the top of the finished floor.

Wall-mounted water closet fixtures shall be securely bolted to an approved carrier fitting. The approved carrier fitting shall be securely attached to the structure. The connecting pipe between the carrier fitting and the fixture shall be an approved material and designed to accommodate an adequately sized gasket. Gasket material shall be neoprene, felt, or similar approved types.

402.6.1 Closet Rings (Closet Flanges). Closet rings (closet flanges) for water closets or similar fixtures shall be of an approved type and shall be copper alloy, copper, hard lead, cast-iron, galvanized malleable iron,

), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.

PLUMBING FIXTURES AND FIXTURE FITTINGS

ABS, PVC, or other approved materials. Closet rings (closet flanges) shall be approximately 7 inches (178 mm) in diameter and, where installed, shall, together with the soil pipe, present a 1 [1] ⁄ 2 inch (38 mm) wide flange or face to receive the fixture gasket or closet seal.

Caulked-on closet rings (closet flanges) shall be not less than [1] ⁄ 4 of an inch (6.4 mm) thick and not less than 2 inches (51 mm) in overall depth.

Closet rings (closet flanges) shall be burned or soldered to lead bends or stubs, shall be caulked to cast-iron soil pipe, shall be solvent cemented to ABS and PVC, and shall be screwed or fastened in an approved manner to other materials.

Closet bends or stubs shall be cut-off to present a smooth surface even with the top of the closet ring before the rough inspection is called.

Closet rings (closet flanges) shall be adequately designed and secured to support fixtures connected thereto.

402.6.2 Securing Closet Flanges. Closet screws, bolts, washers, and similar fasteners shall be of copper alloy, copper, or other listed equally corrosion-resistant materials. Screws and bolts shall be of a size and number to properly support the fixture installed. 402.6.3 Securing Floor-Mounted, Back-Outlet Water Closet Bowls. Floor-mounted, back-outlet water closet bowls shall be set level with an angle of 90 degrees (1.57 rad) between the floor and wall at the centerline of the fixture outlet. The floor and wall shall have a flat mounting surface not less than 5 inches (127 mm) to the right and left of the fixture outlet centerline. The closet flange shall be secured to the wall mounting surface. Offset, eccentric, or reducing closet flanges shall not be permitted with these fixtures.

h an angle of 90 degrees (1.57 rad) between the floor and wall at the centerline of the fixture outlet. The floor and wall shall have a flat mounting surface not less than 5 inches (127 mm) to the right and left of the fixture outlet centerline. The closet flange shall be secured to the wall mounting surface. Offset, eccentric, or reducing closet flanges shall not be permitted with these fixtures.

The fixture shall be secured to the wall outlet flange or drainage connection and the floor by corrosion-resistant screws or bolts.

402.7 Supply Fittings. The supply lines and fittings for

every plumbing fixture shall be so installed as to prevent backflow in accordance with Chapter 6.

402.8 Installation. Fixtures shall be installed in accordance

with the manufacturer’s installation instructions.

402.9 Design and Installation of Plumbing Fixtures.

Plumbing fixtures shall be installed in accordance with the manufacturer’s installation instructions. The means of backflow prevention shall not be compromised by the designated fixture fitting mounting surface.

402.10 Slip Joint Connections.

Fixtures having concealed slip joint connections shall be provided with an access panel or utility space not less than 12 inches (305 mm) in its least dimension and so arranged without obstructions as to make such connections accessible for inspection and repair.

402.11 Future Fixtures. Where provisions are made for the

future installation of fixtures, those provided for shall be considered in determining the required sizes of the drain and water supply piping. Construction for future installations shall be terminated with a plugged fitting or fittings. Where the plugged

fitting is at the point where the trap of a fixture is installed, the plumbing system for such fixture shall be complete and be in accordance with the plumbing requirements of this code.

403.0 Accessible Plumbing Facilities.

403.1 General. Where accessible facilities are required in

applicable building regulations, the facilities shall be installed in accordance with those regulations. [HCD 1-AC] For spe- cific requirements regarding accommodations for persons with disabilities, see Chapter 11A of the California Building Code.

403.2 Fixtures and Fixture Fittings for Persons with

Disabilities. Plumbing fixtures and fixture fittings for persons with disabilities shall be in accordance with ICC A117.1 and the applicable standards referenced in Chapter 4. [HCD 1-AC] Specific requirements regarding accommodations for persons with disabilities are contained in Chapter 11A of the California Building Code.

403.3 Exposed Pipes and Surfaces. Water supply and

drainpipes under accessible lavatories and sinks shall be insulated or otherwise be configured to protect against contact. Protectors, insulators, or both shall comply with ASME A112.18.9 or ASTM C1822. [HCD 1-AC] Specific requirements regard- ing accommodations for persons with disabilities are contained in Chapter 11A of the California Building Code.

404.0 Waste Fittings and Overflows.

404.1 Waste Fittings. Waste fittings shall comply with

ASME A112.18.2/CSA B125.2, ASTM F409 or Table 701.2 for aboveground drainage piping and fittings.

404.2 Overflows.

Where a fixture is provided with an overflow, the overflow shall comply with Section 404.2.1 or Section 404.2.2.

404.2.1 Sinks, Lavatories, and Bathtubs. The waste shall be so arranged that the standing water in the fixture shall not rise in the overflow where the stopper is closed or remain in the overflow where the fixture is empty. The overflow pipe from a fixture shall be connected to the house or inlet side of the fixture trap.

404.2.2 Water Closets and Urinals. Overflows on flush tanks shall be permitted to discharge into the water closets or urinals served by them.

405.0 Prohibited Fixtures.

405.1 Prohibited Water Closets. Water closets having an

invisible seal or an unventilated space or having walls which are not thoroughly washed at each discharge shall be prohibited. A water closet that might permit siphonage of the contents of the bowl back into the tank shall be prohibited.

405.2 Prohibited Urinals. Trough urinals and urinals with

an invisible seal shall be prohibited.

405.3 Miscellaneous Fixtures. Fixed wooden, or tile wash

sinks for domestic use shall not be installed in a building designed or used for human habitation. No sheet metal-lined wooden bathtub shall be installed or reconnected. No dry or chemical closet (toilet) shall be installed in a building used for human habitation unless first approved by the Health Officer.

60 2025 CALIFORNIA PLUMBING CODE

), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.

PLUMBING FIXTURES AND FIXTURE FITTINGS

406.0 Special Fixtures and Specialties.

406.1 Water and Waste Connections.

Baptisteries, ornamental and lily ponds, aquaria, ornamental fountain basins, and similar fixtures and specialties requiring water, waste connections, or both shall be submitted for approval to the Authority Having Jurisdiction prior to installation.

406.2 Special Use Sinks. Restaurant kitchen and other

special use sinks shall be permitted to be made of approvedtype bonderized and galvanized sheet steel of not less than No. 16 U.S. gauge (0.0635 inches) (1.6 mm). Sheet-metal plumbing fixtures shall be adequately designed, constructed, and braced in an approved manner to accomplish their intended purpose.

406.3 Special Use Fixtures. Special use fixtures shall be

made of one of the following:

(1) Soapstone

(2) Chemical stoneware

(3) Copper-based alloy

(4) Nickel-based alloy

(5) Corrosion-resistant steel

(6) Other materials suited for the intended use of the fixture

406.4 Zinc Alloy Components. Zinc alloy components

shall comply with applicable nationally recognized standards and shall be used in accordance with their listing.

407.0 Lavatories.

407.1 Application. Lavatories shall comply with ASME

A112.19.1/CSA B45.2, ASME A112.19.2/CSA B45.1, ASME A112.19.3/CSA B45.4, ASME A112.19.12, CSA B45.5/IAPMO Z124, CSA B45.8/IAPMO Z403, CSA B45.11/IAPMO Z401 or CSA B45.12/IAPMO Z402. Group wash fixtures shall comply with the requirements of Section 401.2. Every 20 inches (508 mm) of rim space of a group wash fixture shall be considered as one lavatory for determining the number of lavatories required in accordance with Table 422.1. Lavatory assemblies with automatic soap dispensers, faucets, or hand dryers shall comply with IAPMO IGC 127.

407.2 Water Consumption. The maximum water flow rate

of faucets shall comply with Section 407.2.1 through Section 407.2.4 .

407.2.1 Public Lavatory Faucets . The maximum flow rate for public lavatory faucets shall not exceed 0.5 gpm at 60 psi (1.9 L/m at 414 kPa).

407.2.2 Residential Lavatory Faucets. [HCD 1] The maximum flow rate of residential lavatory faucets shall not exceed 1.2 gallons (4.54 L) per minute at 60 psi. The minimum flow rate of residential lavatory faucets shall not be less than 0.8 gallons (3.03 L) per minute at 20 psi.

407.2.3 Lavatory Faucets in Common and Public Use Areas. [HCD 1 & HCD 2] The maximum flow rate of lavatory faucets, installed in common and public use areas (outside of dwellings or sleeping units) in residen- tial buildings, shall not exceed 0.5 gallons (1.89 L) per minute at 60 psi.

407.2.4 Metering Faucets. Metered faucets shall deliver a maximum of 0.2 gallons ( 0.76 L) per metering cycle.

407.2.4.1 Metering Faucets. [BSC-CG & DSA- SS] Metering Faucets shall not deliver more than 0.20 gallons (0.76 L) per cycle in compliance with Chapter 5, Division 5.3 of the California Green Building Standards Code (CALGreen).

407.3 Limitation of Hot Water Temperature for Public

Lavatories. Hot water delivered from public-use lavatories shall be limited to a maximum temperature of 120°F (49°C). The maximum temperature shall be regulated by one of the following means:

(1) A limiting device conforming to either ASSE 1070/ASME A112.1070/CSA B125.70, or

(2) A water heater conforming to ASSE 1084.

407.4 Transient Public Lavatories.

Self-closing or metering faucets shall be installed on lavatories intended to serve the transient public, such as those in, but not limited to service stations, train stations, airports, restaurants, and convention halls.

407.5 Waste Outlet. Lavatories shall have a waste outlet

and fixture tailpiece not less than 1 [1] ⁄ 4 inches (32 mm) in diameter. Continuous wastes and fixture tailpieces shall be constructed from the materials specified in Section 701.4. Waste outlets shall be provided with an approved stopper or strainer.

407.6 Overflow. Where overflows are provided, they shall

be installed in accordance with Section 404.2.

408.0 Showers.

408.1 Application. Manufactured shower receptors and

shower bases shall comply with ASME A112.19.1/CSA B45.2, ASME A112.19.2/CSA B45.1, ASME A112.19.3/CSAB45.4, CSA B45.12/IAPMO Z402, or CSA B45.5/IAPMO Z124. Prefabricated shower enclosures shall comply with IAPMO IGC 154.

408.2 Tileable Shower Receptors.

Tileable shower receptors and shower kits shall comply with IAPMO PS 106.

408.3 Water Consumption. Showerheads shall have a «

maximum flow rate of not more than 1.8 gpm at 80 psi ( 6.81 L/m at 552 kPa). Body sprays shall have a flow rate of not more than 1.8 gpm at 80 psi ( 6.81 L/m at 552 kPa). [HCD 1] Residential showerheads shall comply with Division 4.3 of the California Green Building Standards Code (CALGreen). Residential body sprays shall comply with the showerhead requirements in Division 4.3 of CALGreen. [BSC-CG & DSA-SS] Nonresidential body sprays shall comply with the showerhead requirements in Division 5.3 of CALGreen.

408.3.1 Single Showerhead. [BSC-CG & DSA-SS] Showerheads shall have a maximum flow rate of not more than 1.8 gallons (6.81 L) per minute at 80 psi. Showerheads shall be certified to the performance crite- ria of the U.S. EPA WaterSense Specification for Show- erheads in compliance with Chapter 5, Division 5.3. of the California Green Building Standards Code (CAL- Green).

), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.

PLUMBING FIXTURES AND FIXTURE FITTINGS

«

«

«

408.6 Finished Curb or Threshold. Where a shower

receptor has a finished dam, curb, or threshold, it shall be not less than 1 inch (25.4 mm) lower than the sides and back of such receptor. In no case, shall a dam or threshold be less than 2 inches (51 mm) or exceeding 9 inches (229 mm) in depth where measured from the top of the dam or threshold to the top of the drain. Each such receptor shall be provided with a nailing flange either integral or field installed in accordance with the manufacturer’s installation instructions. The flange shall be watertight and extend vertically not less than 1 inch (25.4 mm) above the top of the sides of the receptor. The finished floor of the receptor shall slope uniformly from the sides towards the drain not less than [1] ⁄ 8 inch per foot (10.4 mm/m), nor more than [1] ⁄ 2 inch per foot (41.6 mm/m).

Thresholds shall be of sufficient width to accommodate a minimum 22 inch (559 mm) door. Shower doors shall open so as to maintain not less than a 22 inch (559 mm) unobstructed opening for egress. Where there is a shower without a threshold, the floor space within the same room shall be considered a wet location and shall comply with the requirements of the California Building Code, California Residential Code, and California Electrical Code .

Exceptions:

(1) Showers in accordance with Section 403.2.

(2) A cast-iron shower receptor flange shall be not less than 0.3 of an inch (7.62 mm) in height.

(3) For flanges not used as a means of securing, the sealing flange shall be not less than 0.3 of an inch (7.62 mm) in height.

408.7 Shower Compartments. Shower compartments

shall have a finished interior in accordance with the following: (1) Not less than 1024 square inches (0.6606 m [2] ).

(2) Be capable of encompassing a 30 inch (762 mm) circle.

The minimum required area and dimensions shall be measured at a height equal to the top of the threshold and a point tangent to its centerline. The area and dimensions shall be maintained to a point of not less than 70 inches (1778 mm) above the shower drain outlet with no protrusions other than the fixture valve or valves, showerheads, soap dishes, shelves, and safety grab bars, or rails. Fold-down seats in accessible shower stalls shall be permitted to protrude into the 30 inch (762 mm) circle.

Exceptions:

(1) Showers that are designed to be in accordance with Chapter 11A of the California Building Code .

(2) The minimum required area and dimension shall not apply for a shower receptor having overall dimensions of not less than 30 inches (762 mm) in width and 60 inches (1524 mm) in length.

408.8 Lining for Showers and Receptors. Shower

receptors built on-site shall be watertight and shall be constructed from approved-type dense, nonabsorbent, and noncorrosive materials. Each such receptor shall be adequately reinforced, shall be provided with an approved flanged floor drain designed to make a watertight joint on the floor, and shall have smooth, impervious, and durable surfaces.

»

»

»

»

408.3.2 Multiple Showerheads Serving One Shower. [BSC-CG & DSA-SS] When a shower is served by more than one showerhead, the combined flow rate of all showerheads and/or other shower outlets controlled by a single valve shall not exceed 1.8 gallons (6.81 L) per minute at 80 psi, or the shower shall be designed to allow only one shower outlet to be in operation at a time in com- pliance with Chapter 5, Division 5.3 of the California Green Building Standards Code (CALGreen).

Note: A hand-held shower shall be considered a show-

erhead.

408.4 Individual Shower and Tub-Shower Combina-

tion Control Valves. Showers and tub-shower combinations shall be provided with individual control valves of the pressure balance, thermostatic, or combination pressure balance/thermostatic mixing valve type that provide scald and thermal shock protection for the rated flow rate of the installed showerhead. These valves shall be installed at the point of use and comply with ASSE 1016/ASME A112.1016/CSA B125.16 or ASME A112.18.1/CSA B125.1.

408.4.1 Gang Showers. Where gang showers are supplied with a single temperature-controlled water supply pipe, it shall be controlled by a mixing valve that complies with ASSE 1069.

408.4.2 Temperature Limiting. The maximum water temperature discharging from an individual showerhead shall be limited to 120°F (49°C) by one of the following methods:

(1) A shower or tub/shower combination valve conforming to ASSE 1016/ASME A112.1016/CSA B125.16 where either:

(a) The valve is field-adjusted to the required maximum temperature, or

(b) The handle position, stop, or temperature limiting control is set in accordance with the manufacturer’s instructions to the required maximum temperature.

(2) For gang showers supplied by a single water supply pipe, a mixing valve that conforms to ASSE 1069 that is field-adjusted to the required maximum temperature.

408.4.3 Temperature-Actuated, Flow-Reduction Devices for Individual Fixture Fittings. Temperature-actuated, flow-reduction devices, where installed for individual fixture fittings, shall comply with ASSE 1062. Such devices shall not be used alone as a substitute for the balanced pressure, thermostatic or combination shower valves requirements or as a substitute for bathtub or whirlpool tub water temperature-limiting valves requirements.

408.5 Waste Outlet. Showers shall have a waste outlet and

fixture tailpiece not less than 2 inches (50 mm) in diameter. Fixture tailpieces shall be constructed from the materials specified in Section 701.2 for drainage piping. Strainers serving shower drains shall comply with ASME A112.18.2/CSA B125.2.

62 2025 CALIFORNIA PLUMBING CODE

), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.

PLUMBING FIXTURES AND FIXTURE FITTINGS

shall be insulated from conducting substances, other than the connecting drain, by 15 pound (6.8 kg) asphalt felt or an equivalent. Sheet lead shall be joined by burning. 408.8.4 Sheet Copper. Sheet copper shall comply with ASTM B152 and shall weigh not less than 12 ounces per square foot (oz/ft [2] ) (3.7 kg/m [2] ) or No. 24 B & S Gauge (0.02 inches) (0.51 mm). The copper sheet shall be insulated from conducting substances, other than the connecting drain, by 15 pound (6.8 kg) asphalt felt or an equivalent. Sheet copper shall be joined by brazing or soldering. 408.8.5 Tests for Shower Receptors. Shower receptors shall be tested for watertightness by filling with water to a depth of not less than 2 inches (51 mm) for not less than 15 minutes. Where no threshold is present, a 2 inch (51 mm) barrier shall be temporarily constructed for testing. The test plug shall be so placed that both upper and under sides of the subpan shall be subjected to the test at the point where it is clamped to the drain.

408.9 Public Shower Floors. Floors of public shower

rooms shall have a nonskid surface and shall be drained in such a manner that wastewater from one bather shall not pass over areas occupied by other bathers. Gutters in public or gang shower rooms shall have rounded corners for easy cleaning and shall be sloped not less than 2 percent toward drains. Drains in gutters shall be spaced at a maximum of 8 feet (2438 mm) from sidewalls nor more than 16 feet (4877 mm) apart.

408.10 Location of Valves and Heads. Control valves

and showerheads shall be located on the sidewall of shower compartments or otherwise arranged so that the showerhead does not discharge directly at the entrance to the compartment so that the bather can adjust the valves before stepping into the shower spray.

408.11 Water Supply Riser. A water supply riser from the

shower valve to the showerhead outlet, whether exposed or not, shall be securely attached to the structure.

409.0 Bathtubs and Whirlpool Bathtubs.

409.1 Application. Bathtubs shall comply with ASME

A112.19.1/CSA B45.2, ASME A112.19.2/CSA B45.1, ASME A112.19.3/CSA B45.4, CSA B45.5/IAPMO Z124, or CSA B45.12/IAPMO Z402. Whirlpool bathtubs shall comply with ASME A112.19.7/CSA B45.10. Pressure sealed doors within a bathtub or whirlpool bathtub enclosure shall comply with ASME A112.19.15.

409.2 Waste Outlet. Bathtubs and whirlpool bathtubs shall

have a waste outlet and fixture tailpiece not less than 1 [1] ⁄ 2 inches (40 mm) in diameter. Fixture tailpieces shall be constructed from the materials specified in Section 701.2 for drainage piping. Waste outlets shall be provided with an approved stopper or strainer.

409.3 Overflow. Where overflows are provided, they shall

be installed in accordance with Section 404.2.

409.4 Limitation of Hot Water Temperature in Bath-

tubs and Whirlpool Bathtubs. The maximum hot water temperature discharging from the bathtub and whirlpool bathtub filler shall be limited to 120°F (49°C). The maximum temperature shall be regulated by one of the following means:

«

«

«

«

«

»

»

»

Shower receptors shall have the subfloor and rough side of walls to a height of not less than 3 inches (76 mm) above the top of the finished dam or threshold shall be first lined with sheet plastic, lead, or copper, or shall be lined with other durable and watertight materials. Showers that are provided with a built in place, permanent seat or seating area that is located within the shower enclosure, shall be first lined with sheet plastic, lead, copper, or shall be lined with other durable and watertight materials that extend not less than 3 inches (76 mm) above horizontal surfaces of the seat or the seating area. Lining materials shall be pitched [1] ⁄ 4 inch per foot (20.8 mm/m) to weep holes in the subdrain of a smooth and solidly formed subbase. Such lining materials shall extend upward on the rough jambs of the shower opening to a point not less than 3 inches (76 mm) above the horizontal surfaces of the seat or the seating area, the top of the finished dam or threshold and shall extend outward over the top of the permanent seat, permanent seating area, or rough threshold and be turned over and fastened on the outside face of both the permanent seat, permanent seating area, or rough threshold and the jambs. Nonmetallic shower subpans or linings shall be permitted to be built up on the job site of not less than three layers of standard grade 15 pound (6.8 kg) asphalt impregnated roofing felt. The bottom layer shall be fitted to the formed subbase and each succeeding layer thoroughly hot-mopped to that below. Corners shall be carefully fitted and shall be made strong and watertight by folding or lapping, and each corner shall be reinforced with suitable webbing hot-mopped in place. Folds, laps, and reinforcing webbing shall extend not less than 4 inches (102 mm) in all directions from the corner, and webbing shall be of approved type and mesh, producing a tensile strength of not less than 50 pounds per square foot (lb/ft [2] ) (244 kg/m [2] ) in either direction. Nonmetallic shower subpans or linings shall be permitted to consist of multilayers of other approved equivalent materials suitably reinforced and carefully fitted in place on the job site as elsewhere required in this section.

er, and webbing shall be of approved type and mesh, producing a tensile strength of not less than 50 pounds per square foot (lb/ft [2] ) (244 kg/m [2] ) in either direction. Nonmetallic shower subpans or linings shall be permitted to consist of multilayers of other approved equivalent materials suitably reinforced and carefully fitted in place on the job site as elsewhere required in this section.

Linings shall be properly recessed and fastened to the approved backing so as not to occupy the space required for the wall covering, and shall not be nailed or perforated at a point that is less than 1 inch (25.4 mm) above the finished dam or threshold. An approved type subdrain shall be installed with a shower subpan or lining. Each such subdrain shall be of the type that sets flush with the subbase and shall be equipped with a clamping ring or other device to make a tight connection between the lining and the drain. The subdrain shall have weep holes into the waste line. The weep holes located in the subdrain clamping ring shall be protected from clogging. 408.8.1 PVC Sheets. Plasticized polyvinyl chloride (PVC) sheets shall conform to ASTM D4551. Sheets shall be joined by solvent cementing in accordance with the manufacturer’s installation instructions.

408.8.2 Chlorinated Polyethylene (CPE) Sheets. Nonplasticized chlorinated polyethylene sheets shall conform to ASTM D4068. The liner shall be joined in accordance with the manufacturer’s installation instructions.

408.8.3 Sheet Lead. Sheet lead shall weigh not less than 4 lb/ft [2] (19.5 kg/m [2] ) and shall be coated with an asphalt paint or other approved coating. The lead sheet

), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.

PLUMBING FIXTURES AND FIXTURE FITTINGS

411.2.1 Dual Flush Water Closets. Dual flush water closets shall comply with ASME A112.19.14. The effective flush volume for dual flush water closets shall be defined as the composite, average flush volume of two reduced flushes and one full flush.

411.2.2 Flushometer Valve Activated Water Clos-

ets. Flushometer valve activated water closets shall have a maximum flush volume of 1.28 gallons ( 4.8 Lpf) of water per flush.

411.2.2.1 Flushometer Valve Activated Water Closets. [BSC-CG & DSA-SS] Flushometer valve activated water closets shall have a maximum flush volume of 1.28 gallons (4.8 L) per flush in accordance with ASME A112.19.2/CSA B45.1.

411.2.3 Performance. [HCD 1 & HCD 2] Water clos- ets installed in residential occupancies shall meet or exceed the minimum performance criteria developed for certification of high-efficiency toilets under the WaterSense program sponsored by the U.S. Environ- mental Protection Agency (EPA).

411.2.4 Water Closets. [BSC-CG & DSA-SS] The effective flush volume of all water closets shall not exceed 1.28 gallons (4.8 L) per flush. Tank-type water closets shall be certified to the performance criteria of the U.S. EPA WaterSense Specification for Tank-Type Toilets in compliance with Chapter 5, Division 5.3. of the California Green Building Standards Code (CALGreen).

411.3 Water Closet Seats.

Water closet seats shall be properly sized for the water closet bowl type, and shall be of smooth, non-absorbent material. Seats, for public use, shall be of the elongated type and either of the open front type or have an automatic seat cover dispenser. Water closet seats shall be provided with or without covers. Plastic seats shall comply with IAPMO/ANSI Z124.5.

411.4 Personal Hygiene Devices. Water closets with

integral personal hygiene devices shall comply with ASME A112.4.2/CSA B45.16.

412.0 Urinals.

412.1 Application. Urinals shall comply with ASME

A112.19.2/CSA B45.1, ASME A112.19.19, or CSA B45.5/IAPMO Z124. Wall-mounted urinals shall have an average water consumption not to exceed 0.125 gallons (0.47 L) per flush. Other urinals shall have an average water con- sumption not to exceed 0.5 gallons (1.89 L) per flush.

412.1.1 Wall-Mounted Urinals. [BSC-CG & DSA- SS] The effective flush volume of wall-mounted urinals shall not exceed 0.125 gallons (0.47 L) per flush in com- pliance with Chapter 5, Division 5.3, of the California Green Building Standards Code (CALGreen).

412.1.2 Floor-Mounted Urinals. [BSC-CG & DSA- SS] The effective flush volume of floor-mounted or other urinals shall not exceed 0.5 gallons (1.89 L) per flush in compliance with Chapter 5, Division 5.3, of the California Green Building Standards Code (CALGreen).

»

(1) A limiting device conforming to either ASSE 1070/ASME A112.1070/CSA B125.70 or CSA B125.3.

(2) A water heater conforming to ASSE 1084.

409.5 Backflow Protection. The water supply to a bathtub

and whirlpool bathtub filler valve shall be protected by an air gap or in accordance with Section 417.0.

409.6 Installation and Access. Bathtubs and whirlpool

bathtubs shall be installed in accordance with the manufac turer’s installation instructions. Access openings shall be of a size and opening to permit the removal and replacement of the circulation pump.

Whirlpool pump access located in the crawl space shall be located not more than 20 feet (6096 mm) from an access door, trap door, or crawl hole.

The circulation pump shall be located above the crown weir of the trap.

The pump and the circulation piping shall be self-draining to minimize water retention.

409.6.1 Suction Fittings. Suction fittings on whirlpool bathtubs shall comply with ASME A112.19.7/CSA B45.10.

409.6.2 Flexible PVC Hoses and Tubing. Flexible PVC hoses and tubing intended to be used on whirlpool bathtub water circulation systems or pneumatic systems shall comply with IAPMO/ANSI Z1033.

410.0 Bidets.

410.1 Application. Bidets shall comply with ASME

A112.19.2/CSA B45.1 or ASME A112.19.3/CSA B45.4.

410.2 Backflow Protection. The water supply to the bidet

shall be protected by an air gap or in accordance with Section 603.3.2, Section 603.3.5, or Section 603.3.6.

410.3 Limitation of Water Temperature in Bidets. The

maximum hot water temperature discharging from a bidet shall be limited to 110°F (43°C). The maximum temperature shall be regulated by one of the following means:

(1) A limiting device conforming to either ASSE 1070/ASME A112.1070/CSA B125.70 or CSA B125.3.

(2) A water heater conforming to ASSE 1084.

411.0 Water Closets.

411.1 Application. Water closets shall comply with ASME

A112.19.2/CSA B45.1, ASME A112.19.3/CSA B45.4, or CSA B45.5/IAPMO Z124. Water closet bowls for public use shall be of the elongated type. In nurseries, schools, and other similar places where plumbing fixtures are provided for the use of children less than 6 years of age, water closets shall be of a size and height suitable for children’s use.

411.2 Water Consumption. The effective flush volume of

all water closets shall not exceed 1.28 gallons (4.8 L) per flush when tested in accordance with ASME A112.19.2/CSA

B45.1 .

64 2025 CALIFORNIA PLUMBING CODE

), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.

PLUMBING FIXTURES AND FIXTURE FITTINGS

412.1.3 Nonwater Urinals. Nonwater urinals shall have a liquid barrier sealant to maintain a trap seal. Nonwater urinals shall permit the uninhibited flow of waste through the urinal to the sanitary drainage system. Nonwater urinals shall be cleaned and maintained in accor dance with the manufacturer’s instructions after

installation. Where nonwater urinals are installed, not less than one water supplied fixture rated at not less than 1 water supply fixture unit (WSFU) shall be installed upstream on the same drain line to facilitate drain line flow and rinsing. Where nonwater urinals are installed, they shall have a water distribution line rough-in to each individual urinal location to allow for the installation of an approved backflow prevention device in the event of a retrofit. For additional information, see Health and Safety Code Section 17921.4.

412.1.4 Nonwater Urinals with Drain Cleansing Action. Nonwater urinals with drain cleansing action shall comply with ASME A112.19.19 and shall be cleaned, maintained and installed in accordance with the manufacturer’s installation instructions.

412.1.4.1 [BSC-CG]. Where approved, nonwater urinals with drain cleansing action shall be in com- pliance with Chapter 5, Division A5.3 of the Cali- fornia Green Building Standards Code (CALGreen).

412.2 Backflow Protection. A water supply to a urinal

shall be protected by an approved-type vacuum breaker or other approved backflow prevention device in accordance with Section 603.5.

413.0 Flushing Devices.

413.1 Where Required. Each water closet, urinal, clinical

sink, or other plumbing fixture that depends on trap siphonage to discharge its waste contents shall be provided with a flushometer valve, flushometer tank, or flush tank designed and installed so as to supply water in sufficient quantity and rate of flow to flush the contents of the fixture to which it is connected, to cleanse the fixture, and to refill the fixture trap, without excessive water use. Flushing devices shall comply with the antisiphon requirements in accordance with Section 603.5.

413.2 Flushometer Valves. Flushometer valves and

flushometer tanks shall comply with ASSE 1037/ASME A112.1037/CSA B125.37, and shall be installed in accordance with Section 603.5.1. No manually controlled flushometer valve shall be used to flush more than one urinal, and each such urinal flushometer valve shall be an approved, self-closing type discharging a predetermined quantity of water. Flushometers shall be installed so that they will be accessible for repair. Flushometer valves shall not be used where the water pressure is insufficient to operate them properly. Where the valve is operated, it shall complete the cycle of operation automatically, opening fully, and closing positively under the line water pressure. Each flushometer shall be provided with a means for regulating the flow through it.

[OSPHD 1, 2, 3, 4 & 5] Sensor operated flush valves shall be capable of functioning during loss of normal power.

413.3 Flush Tanks. Flush tanks for manual flushing shall

be equipped with a flush valve that complies with ASME A112.19.5/CSA B45.15 and an antisiphon fill valve (ballcock) that complies with ASSE 1002/ASME A112.1002/CSA B125.12 and installed in accordance with Section 603.5.2.

413.4 Water Supply for Flush Tanks.

An adequate quantity of water shall be provided to flush and clean the fixture served. The water supply for flushing tanks and flushometer tanks equipped for manual flushing shall be controlled by a float valve or other automatic device designed to refill the tank after each discharge and to shut completely off the water flow to the tank where the tank is filled to operational capacity. Provision shall be made to automatically supply water to the fixture to refill the trap seal after each flushing.

413.5 Overflows in Flush Tanks.

Flush tanks shall be provided with overflows discharging into the water closet or urinal connected thereto. Overflows supplied as original parts with the fixture shall be of sufficient size to prevent tank flooding at the maximum rate at which the tank is supplied with water under normal operating conditions and where installed in accordance with the manufacturer’s installation instructions.

414.0 Dishwashing Machines.

414.1 Application. Domestic dishwashing machines shall

comply with UL 749. Domestic dishwashing machines containing sanitation features shall comply with NSF/ANSI 184 and UL 749.

Commercial dishwashing machines shall comply with NSF/ANSI 3 and UL 921.

414.2 Backflow Protection. The water supply connection

to a commercial dishwashing machine shall be protected by an air gap or a backflow prevention device in accordance with Section 603.3.2, Section 603.3.5, Section 603.3.6, or that complies with ASSE 1004.

414.3 Drainage Connection. Domestic dishwashing

machines shall discharge indirectly through an air gap fitting in accordance with Section 807.3 into a waste receptor, a wye branch fitting on the tailpiece of a kitchen sink, or dishwasher connection of a food waste disposer. Commercial dishwashing machines shall discharge indirectly through an air break in accordance with Section 807.1, or by a direct connection in accordance with Section 704.3.

414.4 Lead Content. Dishwashing machines shall comply

with the lead content requirements of Section 604.2.

415.0 Drinking Fountains.

415.1 Application. Drinking fountains shall be self-closing

and comply with ASME A112.19.1/CSA B45.2, ASME A112.19.2/CSA B45.1, or ASME A112.19.3/CSA B45.4. Drinking fountains and bottle filling stations shall also comply with NSF/ANSI/CAN 61. Permanently installed electric water coolers and bottle filling stations shall also comply with UL 399.

[HCD 1] Drinking fountains shall be installed and so regu- lated that a jet of water extending at least 2 inches (51 mm) in height from the water orifice shall be constantly available. The orifice shall not be accessible to the mouth of the drinker nor subject to immersion.

), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.

PLUMBING FIXTURES AND FIXTURE FITTINGS

415.2 Drinking Fountain Alternatives. Where food is

consumed indoors, water stations shall be permitted to be substituted for drinking fountains. Bottle filling stations shall be permitted to be substituted for drinking fountains up to 50 percent of the requirements for drinking fountains. Drinking fountains shall not be required for an occupant load of 30 or less.

415.3 Drainage Connection. Drinking fountains shall be

permitted to discharge directly into the drainage system or indirectly through an air break in accordance with Section 809.1.

415.4 Location. Drinking fountains shall not be installed in

toilet rooms.

416.0 Emergency Eyewash and Shower Equipment.

416.1 Application. Emergency eyewash and shower equipment shall comply with ISEA Z358.1.

416.2 Water Supply. Emergency eyewash and shower

equipment shall not be limited in the water supply flow rates. Where hot and cold water is supplied to an emergency shower or eyewash station, the temperature of the water supply shall be controlled by a temperature actuated mixing valve complying with ASSE 1071. Where water is supplied directly to an emergency shower or eyewash station from a water heater, the water heater shall comply with ASSE 1085. The flow rate, discharge pattern, and temperature of flushing fluids shall be provided in accordance with ISEA Z358.1.

416.3 Installation.

Emergency eyewash and shower equipment shall be installed in accordance with the manufacturer’s

installation instructions.

416.4 Location.

Emergency eyewash and shower equipment shall be located on the same level as the hazard and accessible for immediate use. The path of travel shall be free of obstructions and shall be clearly identified with signage.

416.5 Drain. A drain shall not be required for emergency

eyewash or shower equipment. Where a drain is provided, the discharge shall be in accordance with Section 811.0.

417.0 Faucets and Fixture Fittings.

417.1 Application. Faucets and fixture fittings shall comply

with ASME A112.18.1/CSA B125.1. Fixture fittings covered under the scope of NSF/ANSI/CAN 61 shall comply with the requirements of NSF/ANSI/CAN 61. 417.1.1 Wash Fountains. [BSC-CG & DSA-SS] Wash fountains shall have a maximum flow rate of not more than 1.8 gallons (6.81 L) per minute/20 [rim space (inches) at 60 psi] in compliance with Chapter 5, Divi- sion 5.3 of the California Green Building Standards Code (CALGreen). 417.1.2 Metering Faucets for Wash Fountains.

[BSC-CG & DSA-SS] Metering faucets for wash foun- tains shall have a maximum flow rate of not more than 0.20 gallons (0.76 L) per cycle/20 [rim space (inches) at 60 psi] in compliance with Chapter 5, Division 5.3 of the California Green Building Standards Code (CALGreen).

417.2 Deck Mounted Bath/Shower Valves. Deck

mounted bath/shower transfer valves with integral backflow protection shall comply with ASME A112.18.1/CSA B125.1.

This shall include handheld showers, and other bathing appliances mounted on the deck of bathtubs or other bathing appliances that incorporate a hose or pull out feature.

417.3 Handheld Showers. Handheld showers shall comply

with ASME A112.18.1/CSA B125.1. Handheld showers with integral backflow protection shall comply with ASME A112.18.1/CSA B125.1 or shall have a backflow prevention device that complies with ASME A112.18.3 or ASSE 1014.

417.4 Faucets and Fixture Fittings with Hose Con-

nected Outlets. Faucets and fixture fittings with pull out spout shall comply with ASME A112.18.1/CSA B125.1. Faucets and fixture fittings with pull out spouts with integral backflow protection shall comply with ASME A112.18.1/CSA B125.1 or shall have a backflow preventer device that complies with ASME A112.18.3.

417.5 Separate Controls for Hot and Cold Water.

Where two separate handles control the hot and cold water, the left-hand control of the faucet where facing the fixture fitting outlet shall control the hot water. Faucets and diverters shall be connected to the water distribution system so that hot water corresponds to the left side of the fixture fitting.

Single-handle mixing valves installed in showers and tub-shower combinations shall have the flow of hot water corresponding to the markings on the fixture fitting.

417.6 Low-Pressure Water Dispenser. Beverage faucets

shall comply with ASME A112.18.1/CSA B125.1. Electrically heated or cooled water dispensers shall comply with ASSE 1023.

417.7 Head Shampoo Sink Faucets. Head shampoo sink

faucets shall be supplied with hot water that is limited to not more than 120°F (49°C). Each faucet shall have integral check valves to prevent crossover flow between the hot and cold water supply connections. The means for regulating the maximum temperature shall be in accordance with one of the following:

(1) A limiting device conforming to ASSE 1070/ASME A112.1070/CSA B125.70.

(2) A water heater conforming to ASSE 1084.

(3) A temperature-actuated, flow-reduction device conforming to ASSE 1062.

417.8 Footbaths and Pedicure Baths.

The water supplied to specialty plumbing fixtures, such as pedicure chairs having an integral foot bathtub and footbaths, shall be limited to not more than 120ºF (49ºC) by a water-temperaturelimiting device that conforms to ASSE 1070/ASME A112.1070/CSA B125.70 or by a water heater complying with ASSE 1084.

418.0 Floor Drains.

418.1 Application. Floor drains shall comply with ASME

A112.3.1, ASME A112.6.3, or CSA B79.

418.2 Strainer. Floor drains shall be considered plumbing

fixtures and each such drain shall be provided with an approved-type strainer having a waterway equivalent to the area of the tailpiece. Floor drains shall be of an approved type and shall provide a watertight joint on the floor.

66 2025 CALIFORNIA PLUMBING CODE

), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.

PLUMBING FIXTURES AND FIXTURE FITTINGS

418.3 Location of Floor Drains. Floor drains shall be

installed in the following areas: (1) Toilet rooms containing two or more water closets or a combination of one water closet and one urinal, except in a dwelling unit. (2) Commercial kitchens and in accordance with Section 704.3.

(3) Laundry rooms in commercial buildings and common laundry facilities in multi-family dwelling buildings. (4) Boiler rooms.

418.4 Food Storage Areas. Where drains are provided in

storerooms, walk-in freezers, walk-in coolers, refrigerated equipment, or other locations where food is stored, such drains shall have indirect waste piping. Separate waste pipes shall be run from each food storage area, each with an indirect connection to the building sanitary drainage system. Traps shall be provided in accordance with Section 801.3.2 of this code and shall be vented.

Indirect drains shall be permitted to be located in freezers or other spaces where freezing temperatures are maintained, provided that traps, where supplied, shall be located where the seal will not freeze. Otherwise, the floor of the freezer shall be sloped to a floor drain located outside of the storage compartment.

418.5 Floor Slope. Floors shall be sloped to floor drains.

419.0 Food Waste Disposers.

419.1 Application. Food waste disposal units shall comply

with UL 430. Residential food waste disposers shall also comply with ASSE 1008.

419.2 Drainage Connection. Approved wye or other

directional-type branch fittings shall be installed in continuous wastes connecting or receiving the discharge from a food waste disposer. No dishwasher drain shall be connected to a sink tailpiece, continuous waste, or trap on the discharge side of a food waste disposer.

419.3 Water Supply. A cold water supply shall be provided

for food waste disposers. Such connection to the water supply shall be protected by an air gap or backflow prevention device in accordance with Section 603.2.

420.0 Sinks.

420.1 Application. Sinks shall comply with ASME

A112.19.1/CSA B45.2, ASME A112.19.2/CSA B45.1, ASME A112.19.3/CSA B45.4, CSA B45.5/IAPMO Z124, CSA B45.8/IAPMO Z403, or CSA B45.12/IAPMO Z402. Moveable sink systems shall comply with ASME A112.19.12. Sink assemblies with automatic soap dispensers, faucets, or hand dryers shall comply with IAPMO IGC 127.

420.2 Water Consumption.

Sink faucets shall have a maximum flow rate of not more than 2.2 gpm at 60 psi (8.3 L/m at 414 kPa).

Exceptions: (1) Clinical sinks (2) Laundry sinks (3) Service sinks

420.2.1 Kitchen Faucets. [BSC-CG & DSA-SS] Kitchen faucets shall have a maximum flow rate of not more than 1.8 gallons (6.81 L) per minute at 60 psi (414 kPa). Kitchen faucets may temporarily increase the flow above the maximum rate, but not to exceed 2.2 gallons (8.3 L) per minute at 60 psi (414 kPa), and must default to a maximum flow rate of 1.8 gallons (6.81 L) per minute at 60 psi (414 kPa) in compliance with Chapter 5, Division 5.3 of the California Green Building Stan- dards Code (CALGreen). 420.2.2 Kitchen Faucets. [HCD 1] The maximum flow rate of kitchen faucets shall not exceed 1.8 gallons (6.81 L) per minute at 60 psi (414 kPa). Kitchen faucets may temporarily increase the flow above the maximum rate, but not to exceed 2.2 gallons (8.32 L) per minute at 60 psi (414 kPa), and must default to a maximum flow rate of 1.8 gallons (6.81 L) per minute at 60 psi (414 kPa) in com- pliance with Chapter 4, Division 4.3 or Chapter 5, Divi- sion 5.3 of the California Green Building Standards Code (CALGreen), as applicable. Note: Where faucets meeting the maximum flow rate of 1.8 gpm (6.81 L) are unavailable, aerators or other means may be used to achieve reduction.

420.3 Pre-Rinse Spray Valve. Commercial food service

pre-rinse spray valves shall have a maximum flow rate in accordance with Table 420.3 and shall be equipped with an integral automatic shutoff.

TABLE 420.3

COMMERCIAL PRE-RINSE SPRAY VALVE MAXIMUM FLOW RATE

PRODUCT CLASS BY SPRAY FORCE MAXIMUM FLOW RATE,
GPM

Product Class 1 (≤ 5.0 ounces-force)
1.00


Product Class 2 (> 5.0 ounces-force and
≤ 8.0 ounces-force)
1.20

Product Class 3 (> 8.0 ounces-force)
1.28

For SI units: 1 gallon per minute = 3.785 L/min, 1 ounce-force = 0.278 N

420.4 Waste Outlet. Kitchen and laundry sinks shall have

a waste outlet and fixture tailpiece not less than 1 [1] ⁄ 2 inches (40 mm) in diameter. Service sinks shall have a waste outlet and fixture tailpiece not less than 2 inches (50 mm) in diameter. Fixture tailpieces shall be constructed from the materials specified in Section 701.2 for drainage piping. Waste outlets shall be provided with an approved strainer.

421.0 Floor Sinks.

421.1 Application. Floor sinks shall comply with ASME

A112.6.7.

421.2 Strainers. The waste outlet of a floor sink shall be

provided with an approved strainer or grate that is removable and accessible.

422.0 Minimum Number of Required Fixtures.

422.1 Fixture Count. Plumbing fixtures shall be provided

for the type of building occupancy and in the minimum number shown in Table 422.1. The total occupant load and occu

TABLE 420.3

COMMERCIAL PRE-RINSE SPRAY VALVE MAXIMUM FLOW RATE

For SI units: 1 gallon per minute = 3.785 L/min, 1 ounce-force = 0.278 N

<

), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.

PLUMBING FIXTURES AND FIXTURE FITTINGS

Exceptions [Not adopted for OSHPD 1, 2, 3, 4 & 5] : (1) Residential installations. (2) In occupancies with a total occupant load of 10 or less, including customers and employees, one toilet facility, designed for use by no more than one person at a time, shall be permitted for use by both sexes. (3) In business and mercantile occupancies with a total occupant load of 50 or less including customers and employees, one toilet facility, designed for use by no more than one person at a time, shall be permitted for use by both sexes. (4) Separate facilities shall not be required where rooms have fixtures designed for use by both sexes and the water closets are installed in privacy compartments. Urinals shall be located in a privacy compartment [BSC & DSA-SS] , as defined, or separate private area and be visually separated from the remainder of the room. Water closet and urinal compartments shall comply with sections 422.6 and 422.7 respectively. 422.2.1 Single Use Facilities. Single use toilet facilities, bathing facilities, and family or assisted use toilet facilities shall be identified with signage indicating use by either sex. 422.2.2 Family or Assisted-Use Toilet Facilities. Where a separate toilet facility is required for each sex, and each toilet facility is required to have only one water closet, two family or assisted-use toilet facilities shall be permitted in place of the required separate toilet facilities.

422.3 Fixture Requirements for Special Occupancies.

Additional fixtures shall be permitted to be required where unusual environmental conditions or referenced activities are encountered. In food preparation areas, fixture requirements shall be permitted to be dictated by health codes. 422.3.1 [OSHPD 1, 2, 3, 4, 5 & 6] Separate toilet facil- ities shall be provided for the use of patients, staff per- sonnel and visitors.

Exceptions: (1) For Primary Care Clinics where a facility contains no more than three examination and/or treatment rooms, the patient toilet shall be permitted to serve waiting areas. (2) For public waiting areas with an occupant load of 10 or less, one toilet facility, designed for use by no more than one person at a time, shall be permitted for use by both sexes.

422.4 Toilet Facilities Serving Employees and Cus-

tomers. [Not adopted for OSHPD 1, 2, 3, 4 & 5] Each building or structure shall be provided with toilet facilities for employees and customers. Requirements for customers and employees shall be permitted to be met with a single set of restrooms accessible to both groups. Required toilet facilities for employees and customers located in shopping malls or centers shall be permitted to be met by providing a centrally located toilet facility accessible to several stores. The maximum travel distance from entry to any store to the toilet facility shall not exceed 300 feet (91 440 mm). Required toilet facilities for employees and customers in other than shopping malls or centers shall have a maximum travel distance not to exceed 500 feet (152 m).

»

pancy classification shall be determined in accordance with the California Building Code . Occupancy classification not shown in Table 422.1 shall be considered separately by the Authority Having Jurisdiction.

[OSHPD 1, 2, 3, 4 & 5] Plumbing fixtures shall be provided in the minimum number shown in Table 4-2.

Exception: [BSC & DSA-SS] Using occupancy classifica- tion, described as function of space, determine occupant load factor from Table 4-1 Occupant Load Factor, of this chapter.

422.1.1 Fixture Calculations. The minimum number of fixtures shall be calculated at 50 percent male and 50 percent female based on the total occupant load. Where information submitted indicates a difference in the distribution

of the sexes such information shall be used to determine the number of fixtures for each sex. Once the occupancy load and occupancy are determined, Table 422.1 shall be applied to determine the minimum number of plumbing fixtures required. Where applying the fixture ratios in Table 422.1 results in fractional numbers, such numbers shall be rounded to the next whole number. For multiple occupancies, fractional numbers shall be first summed and then rounded to the next whole number. For toilet facilities designed for use by all genders, the minimum number of fixtures shall be the aggregate calculated at 50 percent female and 50 percent male in accordance with Table 422.1. Where all-gender fixtures are provided in addition to separate men’s and women’s facilities, those fixtures shall be included in determining the number of fixtures provided in an occupancy. [BSC & DSA-SS] The substitution of a water closet for each urinal shall be permitted provided the total number of fixtures installed complies with Table 422.1. 422.1.2 Single Use, Family or Assisted-Use Toilet, and Bathing Facilities. Where single use, family or assisted-use toilet, and bathing rooms are required, in applicable building regulations, the facilities shall be installed in accordance with those regulations. Fixtures located in single use, family or assisted-use, and bathing room facilities shall contribute to the total number of required fixtures in accordance with Section 422.1.

ilet,** and Bathing Facilities. Where single use, family or assisted-use toilet, and bathing rooms are required, in applicable building regulations, the facilities shall be installed in accordance with those regulations. Fixtures located in single use, family or assisted-use, and bathing room facilities shall contribute to the total number of required fixtures in accordance with Section 422.1.

422.1.3 [DSA-AC] Effective January 1, 1990, in new construction and those existing facilities which occu- pancy type are listed in Tables 422.1 and 4-4 for public use, which apply for permit to undertake construction, structural alterations, repairs or improvement which exceed 50 percent of the square footage of the entire facility, shall install water closets, urinals, lavatories and drinking fountains as stipulated in Tables 422.1 and 4-4 for public use. Community and/or municipal parks with a bleacher capacity not exceeding 500 seats shall be exempt from the requirements of this section and Tables

422.1 and 4-4. Each bathroom shall comply with Part 2,

Chapter 11A and 11B of the California Building Code.

422.1.4 [OSHPD 1, 2, 3, 4 & 5] OSHPD facilities shall also comply with requirements of the California Building Code, Sections 1224, 1225, 1226, 1227 and 1228.

422.2 Separate Facilities. Separate toilet facilities shall

be provided for each sex.

68 2025 CALIFORNIA PLUMBING CODE

), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.

PLUMBING FIXTURES AND FIXTURE FITTINGS

422.4.1 Access to Toilet Facilities. In multi-story buildings, accessibility to the required toilet facilities shall not exceed one vertical story. Access to the required toilet facilities for customers shall not pass through areas designated as for employee use only such as kitchens, food preparation areas, storage rooms, closets, or similar spaces. Toilet facilities accessible only to private offices shall not be counted to determine compliance with this section.

422.5 Toilet Facilities for Workers. Toilet facilities shall

be provided and maintained in a sanitary condition for the use of workers during construction.

422.6 Water Closet Compartment. Public water closets

shall occupy a separate compartment with walls or partitions and a door enclosing the fixtures to ensure privacy. Partitions for water closets located in separate gender toilet or bathrooms shall comply with the Type B security requirements of IAPMO Z124.10. Partitions for water closets located in all gender toilet or bathrooms shall comply with the Type A security requirements of IAPMO Z124.10.

Exceptions:

(1) Water closet compartments shall not be required in a single-occupant toilet room having a lockable door.

(2) Toilet rooms in day care facilities having more than one water closets shall be permitted to have one water closet without an enclosing compartment. (3) [BSC & DSA-SS]. Type A Security Requirements of IAPMO Z124.10 in all gender toilet or bathrooms shall not be allowed. Compartments for water closets located in all-gender multi-user bathrooms shall be privacy com- partments, as defined. Each compartment door shall be lockable from the inside of the compartment, with a door locking device that is readily distinguishable as locked from the outside of the compartment. Privacy compart- ments and doors which are not full height or floor to ceil- ing may be permitted by the enforcing agency.

422.7 Urinal Partitions. Each urinal shall be separated with

walls or partitions to provide privacy. The horizontal dimension between walls or partitions at each urinal shall comply with Section 402.5. Partitions for urinals shall comply with the Type C security requirements of IAPMO Z124.10. Walls or partitions shall extend from not less than 12 inches (305 mm) above the finished floor to not less than 60 inches (1524 mm) above the finished floor. Walls shall extend outward from the wall surface not less than 18 inches (457 mm). Urinals located in all gender toilet rooms shall be visually separated from the remainder of the room or each urinal shall be installed in a privacy compartment complying with Type A security requirements of IAPMO Z124.10.

Exceptions:

(1) Urinal partitions shall not be required in a single occupant or family/assisted-use toilet room with a lockable door.

(2) [BSC & DSA-SS]. Type A Security Requirements of IAPMO Z124.10 in all gender toilet rooms shall not be allowed. Urinals in all gender toilet rooms not located in a separate private area shall be privacy compartments, as defined. Each compartment door shall be lockable

from the inside of the compartment, with a door locking device that is readily distinguishable as locked from the outside of the compartment. Privacy compartments and doors which are not full height or floor to ceiling may be permitted by the enforcing agency.

422.8 Cosmetology. [CA] Each school shall provide pub-

lic toilet rooms for each sex on the licensed premises in accor- dance with the California Plumbing Code, Table 422.1.

422.9 Cosmetology Establishments. [CA] Each estab-

lishment where hairdressing services are performed shall pro- vide at least one public toilet room located on the premises in accordance with the California Plumbing Code, Table 422.1.

422.10 Commissaries Serving Mobile Food Prepara-

tion Units. [DPH] Commissaries serving mobile food preparation units shall have at least one hose bib. The hose bib shall be supplied with hot and cold water and be provided with a single spout, a backflow-preventer device and shall be located on the premises of the establishment.

422.11 Employee Lavatories in Food Establishments.

[DPH] Employee lavatories installed in food establishments shall be equipped with an approved single spout capable of providing tempered (100ºF - 115ºF) (37.8ºC - 46.1ºC) run- ning water.

Note: This requirement applies only to commissaries serving mobile food preparation units.

), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.

PLUMBING FIXTURES AND FIXTURE FITTINGS

TABLE 422.1 MINIMUM PLUMBING FACILITIES [1]

Each building shall be provided with sanitary facilities, including provisions for persons with disabilities as prescribed by the Department Having Jurisdiction [8] . Table 422.1 applies to new buildings, additions to a building, and changes of occupancy or type in an existing building resulting in increased occupant

load.

For requirements for persons with disabilities, Chapter 11A or 11B of the California Building Code shall be used .

[BSC & DSA-SS] The total occupant load shall be determined in accordance with the California Building Code or Table 4-1 Occupant Load Factor.

Exceptions: (1) [HCD 1-AC & HCD 2] For applications listed in Sections 1.8.2.1.2 and 1.8.2.1.3 regulated by the Department of Housing and Community Development, each building shall be provided with sanitary facilities, including provisions for persons with disabilities as prescribed by the Department. Covered mul- tifamily dwellings required to be accessible to persons with disabilities shall comply with Chapter 11A of the California Building Code. Permanent build- ings in mobilehome parks and special occupancy parks required to be accessible by persons with disabilities, shall comply with Chapter 11B of the California Building Code. (2) [HCD 1] For limited density owner-built rural dwelling sanitary facilities, the type, design and number of facilities as required and approved by the local health official shall be provided to the dwelling sites. It shall not be required that such facilities be located within the dwelling.

persons with disabilities, shall comply with Chapter 11B of the_ California Building Code. (2) [HCD 1] For limited density owner-built rural dwelling sanitary facilities, the type, design and number of facilities as required and approved by the local health official shall be provided to the dwelling sites. It shall not be required that such facilities be located within the dwelling.

TYPE OF
OCCUPANCY2
WATER CLOSETS
(FIXTURES PER PERSON)3
URINALS
(FIXTURES
PER
PERSON)4
LAVATORIES
(FIXTURES PER PERSON)5
BATHTUBS
OR
SHOWERS
(FIXTURES
PER
PERSON)
DRINKING
FOUNTAINS/
FACILITIES
(FIXTURES
PER
PERSON)
OTHER6, 7
A-1 Assembly occupancy
(fixed or permanent seat-
ing)- theaters, concert
halls, and auditoriums
Male
1: 1-100
2: 101-200
3: 201-400
Female
1: 1-25
2: 26-50
3: 51-100
4: 101-200
6: 201-300
8: 301-400
Male
1: 1-200
2: 201-300
3: 301-400
4: 401-600
Male
1: 1-200
2: 201-400
3: 401-600
4: 601-750
Female
1: 1-100
2: 101-200
4: 201-300
5: 301-500
6: 501-750
––
1: 1-250
2: 251-500
3: 501-750
1 service
sink or
laundry sink
A-1 Assembly occupancy
(fixed or permanent seat-
ing)- theaters, concert
halls, and auditoriums
Over 400, add 1 fixture for
each additional 500 males
and 1 fixture for each
additional 125 females.
Over 400, add 1 fixture for
each additional 500 males
and 1 fixture for each
additional 125 females.
Over 600,
add 1 fixture
for each
additional
300 males.
Over 750, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
Over 750, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
Over 750, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
Over 750,
add 1 fixture
for each
additional
500 persons.
Over 750,
add 1 fixture
for each
additional
500 persons.
A-2 Assembly occu-
pancy- restaurants, pubs,
lounges, nightclubs and
banquet halls
Male
1: 1-50
2: 51-150
3: 151-300
4: 301-400
Female
1: 1-25
2: 26-50
3: 51-100
4: 101-200
6: 201-300
8: 301-400
Male
1: 1-200
2: 201-300
3: 301-400
4: 401-600
Male
1: 1-150
2: 151-200
3: 201-400
Female
1: 1-150
2: 151-200
4: 201-400
––
1: 1-250
2: 251-500
3: 501-750
1 service
sink or
laundry sink
A-2 Assembly occu-
pancy- restaurants, pubs,
lounges, nightclubs and
banquet halls
Over 400, add 1 fixture for
each additional 250 males
and 1 fixture for each 125
females.
Over 400, add 1 fixture for
each additional 250 males
and 1 fixture for each 125
females.
Over 600,
add 1 fixture
for each
additional
300 males.
Over 400, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females
Over 400, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females
Over 400, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females
Over 750,
add 1 fixture
for each
additional
500 persons.
Over 750,
add 1 fixture
for each
additional
500 persons.
A-3 Assembly occupancy
(typical without fixed or
permanent seating)-
arcades, places of wor-
ship, museums, libraries,
lecture halls, gymnasiums
(without spectator seat-
ing), indoor pools (with-
out spectator seating)
Male
1: 1-100
2: 101-200
3: 201-400
Female
1: 1-25
2: 26-50
3: 51-100
4: 101-200
6: 201-300
8: 301-400
Male
1: 1-100
2: 101-200
3: 201-400
4: 401-600
Male
1: 1-200
2: 201-400
3: 401-600
4: 601-750
Female
1: 1-100
2: 101-200
4: 201-300
5: 301-500
6: 501-750
––
1: 1-250
2: 251-500
3: 501-750
1 service
sink or
laundry sink
A-3 Assembly occupancy
(typical without fixed or
permanent seating)-
arcades, places of wor-
ship, museums, libraries,
lecture halls, gymnasiums
(without spectator seat-
ing), indoor pools (with-
out spectator seating)
Over 400, add 1 fixture for
each additional 500 males
and 1 fixture for each
additional 125 females.
Over 400, add 1 fixture for
each additional 500 males
and 1 fixture for each
additional 125 females.
Over 600,
add 1 fixture
for each
additional
300 males.
Over 750, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
Over 750, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
Over 750, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
Over 750,
add 1 fixture
for each
additional
500 persons.
Over 750,
add 1 fixture
for each
additional
500 persons.

70 2025 CALIFORNIA PLUMBING CODE

), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.

PLUMBING FIXTURES AND FIXTURE FITTINGS

TABLE 422.1 MINIMUM PLUMBING FACILITIES [1] (continued)

TYPE OF
OCCUPANCY2
WATER CLOSETS
(FIXTURES PER PERSON)3
URINALS
(FIXTURES
PER
PERSON)4
LAVATORIES
(FIXTURES PER PERSON)5
BATHTUBS
OR
SHOWERS
(FIXTURES
PER
PERSON)
DRINKING
FOUNTAINS/
FACILITIES
(FIXTURES
PER
PERSON)
OTHER6, 7
A-4 Assembly occupancy
(indoor activities or sport-
ing events with spectator
seating)- swimming
pools, skating rinks, are-
nas, and gymnasiums
Male
1: 1-100
2: 101-200
3: 201-400
Female
1: 1-25
2: 26-50
3: 51-100
4: 101-200
6: 201-300
8: 301-400
Male
1: 1-100
2: 101-200
3: 201-400
4: 401-600
Male
1: 1-200
2: 201-400
3: 401-750
Female
1: 1-100
2: 101-200
4: 201-300
5: 301-500
6: 501-750
–– 1: 1-250
2: 251-500
3: 501-750
1 service
sink or
laundry sink
A-4 Assembly occupancy
(indoor activities or sport-
ing events with spectator
seating)- swimming
pools, skating rinks, are-
nas, and gymnasiums
Over 400, add 1 fixture for
each additional 500 males
and 1 fixture for each addi-
tional 125 females.
Over 400, add 1 fixture for
each additional 500 males
and 1 fixture for each addi-
tional 125 females.
Over 600,
add 1 fixture
for each
additional
300 males.
Over 750, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
Over 750, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
Over 750, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
Over 750,
add 1 fixture
for each
additional
500 persons.
Over 750,
add 1 fixture
for each
additional
500 persons.
A-5Assembly occupancy
(outdoor activities or
sporting events)- amuse-
ment parks, grandstands
and stadiums
Male
1: 1-100
2: 101-200
3: 201-400
Female
1: 1-25
2: 26-50
3: 51-100
4: 101-200
6: 201-300
8: 301-400
Male
1: 1-100
2: 101-200
3: 201-400
4: 401-600
Male
1: 1-200
2: 201-400
3: 401-750
Female
1: 1-100
2: 101-200
4: 201-300
5: 301-500
6: 501-750
–– 1: 1-250
2: 251-500
3: 501-750
1 service
sink or
laundry sink
A-5Assembly occupancy
(outdoor activities or
sporting events)- amuse-
ment parks, grandstands
and stadiums
Over 400, add 1 fixture for
each additional 500 males
and 1 fixture for each addi-
tional 125 females.
Over 400, add 1 fixture for
each additional 500 males
and 1 fixture for each addi-
tional 125 females.
Over 600,
add 1 fixture
for each
additional
300 males.
Over 750, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
Over 750, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
Over 750, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
Over 750,
add 1 fixture
for each
additional
500 persons.
Over 750,
add 1 fixture
for each
additional
500 persons.
B Business occupancy
(office, professional or
service type transactions)-
banks, vet clinics, hospi-
tals, car wash, banks,
beauty salons, ambulatory
health care facilities, laun-
dries and dry cleaning,
educational institutions
(above high school), or
training facilities not
located within school, post
offices and printing shops
Male
1: 1-50
2: 51-100
3: 101-200
4: 201-400
Female
1: 1-15
2: 16-30
3: 31-50
4: 51-100
8: 101-200
11: 201-400
Male
1: 1-100
2: 101-200
3: 201-400
4: 401-600
Male
1: 1-75
2: 76-150
3: 151-200
4: 201-300
5: 301-400
Female
1: 1-50
2: 51-100
3: 101-150
4: 151-200
5: 201-300
6: 301-400
–– 1 per 150 1 service
sink or
laundry sink
B Business occupancy
(office, professional or
service type transactions)-
banks, vet clinics, hospi-
tals, car wash, banks,
beauty salons, ambulatory
health care facilities, laun-
dries and dry cleaning,
educational institutions
(above high school), or
training facilities not
located within school, post
offices and printing shops
Over 400, add 1 fixture
for each additional 500
males and 1 fixture for
each additional 150
females.
Over 400, add 1 fixture
for each additional 500
males and 1 fixture for
each additional 150
females.
Over 600,
add 1 fixture
for each
additional
300 males.
Over 400, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
Over 400, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
Over 400, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
Over 400, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
Over 400, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
E Educational occupancy-
private or public schools
Male
1 per 50
Female
1 per 30
Male
1 per 100
Male
1 per 40
Female
1 per 40
–– 1 per 150 1 service
sink or
laundry sink
F1, F2 Factory or Indus-
trial occupancy-fabricat-
ing or assembly work
Male
1: 1-50
2: 51-75
3: 76-100
Female
1: 1-50
2: 51-75
3: 76-100
–– Male
1: 1-50
2: 51-75
3: 76-100
Female
1: 1-50
2: 51-75
3: 76-100
1 shower for
each 15
persons
exposed to
excessive
heat or to
skin con-
tamination
with poison-
ous, infec-
tious or
irritating
material
1: 1-250
2: 251-500
3: 501-750
1 service
sink or
laundry sink
TYPE OF
OCCUPANCY2
WATER CLOSETS
(FIXTURES PER PERSON)3
URINALS
(FIXTURES
PER
PERSON)4
LAVATORIES
(FIXTURES PER PERSON)5
BATHTUBS
OR
SHOWERS
(FIXTURES
PER
PERSON)
DRINKING
FOUNTAINS/
FACILITIES
(FIXTURES
PER
PERSON)
OTHER6, 7
F1, F2 Factory or Indus-
trial occupancy-fabricat-
ing or assembly work
Over 100, add 1 fixture
for each additional 40 per-
sons.
Over 100, add 1 fixture
for each additional 40 per-
sons.
–– Over 100, add 1 fixture for
each additional 40 per-
sons.
Over 100, add 1 fixture for
each additional 40 per-
sons.
Over 100, add 1 fixture for
each additional 40 per-
sons.
Over 750,
add 1 fixture
for each
additional
500 persons.
Over 750,
add 1 fixture
for each
additional
500 persons.

), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.

PLUMBING FIXTURES AND FIXTURE FITTINGS

TABLE 422.1

MINIMUM PLUMBING F FACILITIES1 (continued)
TYPE OF
OCCUPANCY2
TYPE OF
OCCUPANCY2
WATER CLOSETS
(FIXTURES PER PERSON)3
WATER CLOSETS
(FIXTURES PER PERSON)3
URINALS
(FIXTURES
PER
PERSON)4
LAVATORIES
(FIXTURES PER PERSON)5
LAVATORIES
(FIXTURES PER PERSON)5
BATHTUBS
OR
SHOWERS
(FIXTURES
PER
PERSON)
DRINKING
FOUNTAINS/
FACILITIES
(FIXTURES
PER
PERSON)
OTHER6, 7
I-1 Institutional occu-
pancy (houses more than
16 persons on a 24-hour
basis)- substance abuse
centers, assisted living,
group homes, or residen-
tial facilities
I-1 Institutional occu-
pancy (houses more than
16 persons on a 24-hour
basis)- substance abuse
centers, assisted living,
group homes, or residen-
tial facilities
Male
1 per 15
Female
1 per 15
–– Male
1 per 15
Female
1 per 15
1 per 8 1 per 150 1 service
sink or
laundry sink
I-2 Institu-
tional occu-
pancy-medi
cal, psychi-
atric, surgi-
cal or
nursing
homes
Hospitals
and nursing
homes-indi-
vidual
rooms and
ward room
1 per room 1 per room –– 1 per room 1 per room 1 per room 1 per 150 1 service
sink or
laundry sink
I-2 Institu-
tional occu-
pancy-medi
cal, psychi-
atric, surgi-
cal or
nursing
homes
Hospitals
and nursing
homes-indi-
vidual
rooms and
ward room
1 per 8 patients 1 per 8 patients –– 1 per 10 patients 1 per 10 patients 1 per 20
patients
1 per 20
patients
1 per 20
patients
I-2 Institu-
tional occu-
pancy-medi
cal, psychi-
atric, surgi-
cal or
nursing
homes
Hospital
Waiting or
Visitor
Rooms
1 per room 1 per room –– 1 per room 1 per room –– 1 per room ––
I-2 Institu-
tional occu-
pancy-medi
cal, psychi-
atric, surgi-
cal or
nursing
homes
Employee
Use
Male
1: 1-15
2: 16-35
3: 36-55
Female
1: 1-15
3: 16-35
4: 36-55
–– Male
1 per 40
Female
1 per 40
–– –– ––
I-2 Institu-
tional occu-
pancy-medi
cal, psychi-
atric, surgi-
cal or
nursing
homes
Employee
Use
Over 55, add 1 fixture for
each additional 40 persons.
Over 55, add 1 fixture for
each additional 40 persons.
Over 55, add 1 fixture for
each additional 40 persons.
Over 55, add 1 fixture for
each additional 40 persons.
Over 55, add 1 fixture for
each additional 40 persons.
Over 55, add 1 fixture for
each additional 40 persons.
Over 55, add 1 fixture for
each additional 40 persons.
Over 55, add 1 fixture for
each additional 40 persons.
I-3Institu-
tional occu-
pancy
(houses
more than 5
people)
Prisons 1 per cell 1 per cell –– 1 per cell 1 per cell 1 per 20 1 per cell
block/floor
––
I-3Institu-
tional occu-
pancy
(houses
more than 5
people)
Correctional
facilities or
juvenile
center
1 per 8 1 per 8 –– 1 per 10 1 per 10 1 per 8 1 per floor 1 service
sink or
laundry sink
I-3Institu-
tional occu-
pancy
(houses
more than 5
people)
Employee
Use
Male
1: 1-15
2: 16-35
3: 36-55
Female
1: 1-15
3: 16-35
4: 36-55
–– Male
1 per 40
Female
1 per 40
–– 1 per 150 ––
I-3Institu-
tional occu-
pancy
(houses
more than 5
people)
Employee
Use
Over 55, add 1 fixture for
each additional 40 persons.
Over 55, add 1 fixture for
each additional 40 persons.
Over 55, add 1 fixture for
each additional 40 persons.
Over 55, add 1 fixture for
each additional 40 persons.
Over 55, add 1 fixture for
each additional 40 persons.
Over 55, add 1 fixture for
each additional 40 persons.
Over 55, add 1 fixture for
each additional 40 persons.
Over 55, add 1 fixture for
each additional 40 persons.
I-4Institutional occu-
pancy (any age that
receives care for less than
24 hours)
I-4Institutional occu-
pancy (any age that
receives care for less than
24 hours)
Male
1: 1-15
2: 16-35
3: 36-55
Female
1: 1-15
3: 16-35
4: 36-55
–– Male
1 per 40
Female
1 per 40
–– 1 per 150 1 service
sink or
laundry sink
I-4Institutional occu-
pancy (any age that
receives care for less than
24 hours)
I-4Institutional occu-
pancy (any age that
receives care for less than
24 hours)
Over 55, add 1 fixture for
each additional 40 per-
sons.
Over 55, add 1 fixture for
each additional 40 per-
sons.
Over 55, add 1 fixture for
each additional 40 per-
sons.
Over 55, add 1 fixture for
each additional 40 per-
sons.
Over 55, add 1 fixture for
each additional 40 per-
sons.
Over 55, add 1 fixture for
each additional 40 per-
sons.
Over 55, add 1 fixture for
each additional 40 per-
sons.
Over 55, add 1 fixture for
each additional 40 per-
sons.
M Mercantile occupancy
(the sale of merchandise
and accessible to the pub-
lic)
M Mercantile occupancy
(the sale of merchandise
and accessible to the pub-
lic)
Male
1: 1-100
2: 101-200
3: 201-400
Female
1: 1-100
2: 101-200
4: 201-300
6: 301-400
Male
0: 1-200
1: 201-400
Male
1: 1-200
2: 201-400
Female
1: 1-200
2: 201-300
3: 301-400
–– 1: 1-250
2: 251-500
3: 501-750
1 service
sink or
laundry sink
MINIMUM PLUMBING F FACILITIES1 (continued)
M Mercantile occupancy
(the sale of merchandise
and accessible to the pub-
lic)
M Mercantile occupancy
(the sale of merchandise
and accessible to the pub-
lic)
Over 400, add 1 fixture for
each additional 500 males
and 1 fixture for each 200
females.
Over 400, add 1 fixture for
each additional 500 males
and 1 fixture for each 200
females.
Over 400,
add 1 fixture
for each
additional
500 males.
Over 400, add 1 fixture for
each additional 500 males
and 1 fixture for each 400
females.
Over 400, add 1 fixture for
each additional 500 males
and 1 fixture for each 400
females.
–– Over 750,
add 1 fixture
for each
additional
500 persons.
––

72 2025 CALIFORNIA PLUMBING CODE

), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.

PLUMBING FIXTURES AND FIXTURE FITTINGS

TABLE 422.1

MINIMUM PLUMBING F FACILITIES1 (continued)
TYPE OF
OCCUPANCY2
TYPE OF
OCCUPANCY2
WATER CLOSETS
(FIXTURES PER PERSON)3
WATER CLOSETS
(FIXTURES PER PERSON)3
URINALS
(FIXTURES
PER
PERSON)4
LAVATORIES
(FIXTURES PER PERSON)5
LAVATORIES
(FIXTURES PER PERSON)5
BATHTUBS
OR
SHOWERS
(FIXTURES
PER
PERSON)
DRINKING
FOUNTAINS/
FACILITIES
(FIXTURES
PER
PERSON)
OTHER6, 7
R-1 Residential occu-
pancy (minimal stay)-
hotels, motels, bed and
breakfast homes
R-1 Residential occu-
pancy (minimal stay)-
hotels, motels, bed and
breakfast homes
1 per sleeping room 1 per sleeping room –– 1 per sleeping room 1 per sleeping room 1 per sleep-
ing room
–– 1 service sink
or
laundry sink
R-2 Resi-
dential
occupancy
(long-term
or perma-
nent)
Dormitories Male
1 per 10
Female
1 per 8
Male
1 per 25
Male
1 per 12
Female
1 per 12
1 per 8 1 per 150 1 service
sink or
laundry sink
R-2 Resi-
dential
occupancy
(long-term
or perma-
nent)
Dormitories Add 1 fixture for each
additional 25 males and 1
fixture for each additional
20 females.
Add 1 fixture for each
additional 25 males and 1
fixture for each additional
20 females.
Over 150,
add 1 fixture
for each
additional
50 males.
Add 1 fixture for each
additional 20 males and 1
fixture for each additional
15 females.
Add 1 fixture for each
additional 20 males and 1
fixture for each additional
15 females.
Add 1 fixture for each
additional 20 males and 1
fixture for each additional
15 females.
Add 1 fixture for each
additional 20 males and 1
fixture for each additional
15 females.
Add 1 fixture for each
additional 20 males and 1
fixture for each additional
15 females.
R-2 Resi-
dential
occupancy
(long-term
or perma-
nent)
Employee
Use
Male
1: 1-15
2: 16-35
3: 36-55
Female
1: 1-15
3: 16-35
4: 36-55
–– Male
1 per 40
Female
1 per 40
–– –– ––
R-2 Resi-
dential
occupancy
(long-term
or perma-
nent)
Employee
Use
Over 55, add 1 fixture for
each additional 40 persons
Over 55, add 1 fixture for
each additional 40 persons
Over 55, add 1 fixture for
each additional 40 persons
Over 55, add 1 fixture for
each additional 40 persons
Over 55, add 1 fixture for
each additional 40 persons
Over 55, add 1 fixture for
each additional 40 persons
Over 55, add 1 fixture for
each additional 40 persons
Over 55, add 1 fixture for
each additional 40 persons
R-2 Resi-
dential
occupancy
(long-term
or perma-
nent)
Apartment
house/unit
1 per apartment 1 per apartment –– 1 per apartment 1 per apartment 1 per
apartment
–– 1 kitchen sink
per apartment.
1 laundry sink
or 1 automatic
clothes washer
connection
per unit or 1
laundry sink or
1 automatic
clothes washer
connection for
each 12 units
R-3 Residential occu-
pancy (long-term or per-
manent in nature) for
more than 5 but does not
exceed 16 occupants)
R-3 Residential occu-
pancy (long-term or per-
manent in nature) for
more than 5 but does not
exceed 16 occupants)
Male
1 per 10
Female
1 per 8
–– Male
1 per 12
Female
1 per 12
1 per 8 1 per 150 1 service
sink or
laundry sink
R-3 Residential occu-
pancy (long-term or per-
manent in nature) for
more than 5 but does not
exceed 16 occupants)
R-3 Residential occu-
pancy (long-term or per-
manent in nature) for
more than 5 but does not
exceed 16 occupants)
Add 1 fixture for each
additional 25 males and 1
fixture for each additional
20 females.
Add 1 fixture for each
additional 25 males and 1
fixture for each additional
20 females.
Add 1 fixture for each
additional 25 males and 1
fixture for each additional
20 females.
Add 1 fixture for each
additional 20 males and 1
fixture for each additional
15 females.
Add 1 fixture for each
additional 20 males and 1
fixture for each additional
15 females.
Add 1 fixture for each
additional 20 males and 1
fixture for each additional
15 females.
Add 1 fixture for each
additional 20 males and 1
fixture for each additional
15 females.
Add 1 fixture for each
additional 20 males and 1
fixture for each additional
15 females.
R-3 Residential occu-
pancy (one and two fam-
ily dwellings)
R-3 Residential occu-
pancy (one and two fam-
ily dwellings)
1 per one and two family
dwelling
1 per one and two family
dwelling
–– 1 per one and two family
dwelling
1 per one and two family
dwelling
1 per one
and two
family
dwelling
–– 1 kitchen
sink and
1 automatic
clothes washer
connection per
one and two
family
dwelling
R-4 Residential occu-
pancy (residential care or
assisted living)
R-4 Residential occu-
pancy (residential care or
assisted living)
Male
1 per 10
Female
1 per 8
–– Male
1 per 12
Female
1 per 12
1 per 8 1 per 150 1 service
sink or
laundry sink
MINIMUM PLUMBING F FACILITIES1 (continued)
R-4 Residential occu-
pancy (residential care or
assisted living)
R-4 Residential occu-
pancy (residential care or
assisted living)
Add 1 fixture for each
additional 25 males and 1
fixture for each additional
20 females.
Add 1 fixture for each
additional 25 males and 1
fixture for each additional
20 females.
Add 1 fixture for each
additional 25 males and 1
fixture for each additional
20 females.
Add 1 fixture for each
additional 20 males and 1
fixture for each additional
15 females.
Add 1 fixture for each
additional 20 males and 1
fixture for each additional
15 females.
Add 1 fixture for each
additional 20 males and 1
fixture for each additional
15 females.
Add 1 fixture for each
additional 20 males and 1
fixture for each additional
15 females.
Add 1 fixture for each
additional 20 males and 1
fixture for each additional
15 females.

), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.

PLUMBING FIXTURES AND FIXTURE FITTINGS

TABLE 422.1

MINIMUM PLUMBING F FACILITIES1 (continued)
TYPE OF
OCCUPANCY2
WATER CLOSETS
(FIXTURES PER PERSON)3
WATER CLOSETS
(FIXTURES PER PERSON)3
URINALS
(FIXTURES
PER
PERSON)4
LAVATORIES
(FIXTURES PER PERSON)5
LAVATORIES
(FIXTURES PER PERSON)5
BATHTUBS
OR
SHOWERS
(FIXTURES
PER
PERSON)
DRINKING
FOUNTAINS/
FACILITIES
(FIXTURES
PER
PERSON)
OTHER6, 7
S-1, S-2 Storage occu-
pancy-storage of goods,
warehouse, aircraft
hanger, food products,
appliances
Male
1: 1-100
2: 101-200
3: 201-400
Female
1: 1-100
2: 101-200
3: 201-400
––
Male
1: 1-200
2: 201-400
3: 401-750
Female
1: 1-200
2: 201-400
3: 401-750
––
1: 1-250
2: 251-500
3: 501-750
1 service
sink or
laundry sink
S-1, S-2 Storage occu-
pancy-storage of goods,
warehouse, aircraft
hanger, food products,
appliances
Over 400, add 1 fixture for
each additional 500 males
and 1 fixture for each
additional 150 females.
Over 400, add 1 fixture for
each additional 500 males
and 1 fixture for each
additional 150 females.
Over 400, add 1 fixture for
each additional 500 males
and 1 fixture for each
additional 150 females.
Over 750, add 1 fixture for
each additional 500 per-
sons.
Over 750, add 1 fixture for
each additional 500 per-
sons.
Over 750, add 1 fixture for
each additional 500 per-
sons.
Over 750,
add 1 fix-
ture for
each addi-
tional 500
persons.
Over 750,
add 1 fix-
ture for
each addi-
tional 500
persons.

N otes: 1 The figures shown are based upon one fixture being the minimum required for the number of persons indicated or any fraction thereof. 2 A restaurant is defined as a business that sells food to be consumed on the premises. a. The number of occupants for a drive-in restaurant shall be considered as equal to the number of parking stalls. b. Hand-washing facilities shall be available in the kitchen for employees. 3 The total number of required water closets for females shall be not less than the total number of required water closets and urinals for males. [BSC] This requirement shall not apply when single occupancy toilet facilities are provided for each sex in an A or E occupancy with an occupant load of less than 50. Either

a. The required urinal shall be permitted to be omitted or b. If installed, the urinal shall not require a second water closet to be provided for the female. 4 For each urinal added in excess of the minimum required, one water closet shall be permitted to be deducted. The number of water closets shall not be reduced to less than two-thirds of the minimum requirement. 5 Metering or self-closing faucets shall be installed on lavatories intended to serve the transient public. 6 Service sinks shall not be required for non-residential occupancies with an occupant load of 15 or less. 7 For business and mercantile occupancies, one common service sink shall be permitted when accessible to all businesses and mercantile within 300 feet (91 440 mm) and within the same story. 8 [BSC, DSA-AC, DSA-SS, HCD 1 & HCD 2, OSHPD 1, 2, 3, 4 & 5] In accordance with Sections 1.8.7 and 301.3, the Authority Having Jurisdiction may approve alternative design criteria when determining the minimum number of plumbing fixtures.

74 2025 CALIFORNIA PLUMBING CODE

), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.

PLUMBING FIXTURES AND FIXTURE FITTINGS

TABLE 4-1 OCCUPANT LOAD FACTOR: [BSC & DSA-SS]

**FUNCTION OF SPACE* **** OCCUPANT
LOAD FACTOR
(square feet)
Assembly_ - without fixed seats_
Auditorium, convention and dance hall, lodge, stage, indoor sport/spectator event, worship, arcade, gaming
(standing space)
11
Waiting, terminal (portable seating space) 15
Conference, dining/drinking, lounge (portable seating/table space) 30
Gallery, museum, exhibit (standing space) 30
Assembly_ – with fixed seats_ See CBC 1004.6
Use 50% of the fixed
seating value
Business_ (office, sales/soliciting, administration, food processing, courtroom, ambulatory clinic)_ 150
See CBC 1004.8
Dormitory 50
Day care 35
Education_ (classroom)_
Through 12th grade
30
Education_ (classroom)_
Beyond 12th grade
50
Exercise_ (fitness)_ 50
Industrial_ (fabrication, foundry, workshop, component assembly, repair)_ 500
Kitchen/food prep_ (commercial)_ 50
Laboratory
Educational
50
Laboratory
Non-educational
100
Library 50
Mercantile_ (wholesale, retail)_ 100
Mall building_ (covered/open)_ See CBC 402.8.2
Residential_ (long term: central toilet facilities)_ 200
Warehouse
Storage portions
4000
Warehouse
Distribution portions (selecting, processing, packing, receiving, shipping)
500
  • Any uses not specifically listed shall be based on similar uses listed in this table.

** For a building or space with mixed occupancies, use appropriate occupancy group for each area (for example, a school may have an “A” occupancy for the gymnasium, a “B” occupancy for the office, an “E” occupancy for the classrooms, etc.). Accessory areas such as, but not limited to, hallways/corri- dors, stairways, ramps, toilet rooms, mechanical rooms, closets and fixed equipment, may be excluded.

), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.

PLUMBING FIXTURES AND FIXTURE FITTINGS

TABLE 4-2

[OSHPD 1, 2, 3, 4 & 5] [24] MINIMUM PLUMBING FACILITIES

SPACE HANDWASHING
FIXTURE
SCRUB
SINKS3
TOILETS BATHTUBS
OR SHOWERS
SERVICE
SINKS1
CLINIC
SINKS
Administration Lobby
Public Toilet - Male 12 1
Public Toilet - Female 12 1
Airborne infection isolation room 120
Airborne infection isolation treatment/exam room 120
Airborne infection isolation anteroom 1
Airborne infection isolation toilet room 12 15 15
Cardiac Catheterization procedure room 14, 33
Central Sterile Supply 115
Cesarean/Delivery Service Space
Labor Rooms 133 19 19
Recovery Room 133 1
Drug distribution station 1
Cesarean operating room 210, 33
Delivery room 110, 33
LDR or LDRP room 133 1 1
Staff lounge
Staff Toilet - Male 12 1:1-15
Staff Toilet - Female 12 1:1-15
Waiting area/room
Public Toilet - Male 12 1
Public Toilet - Female 12 1
Clinical Laboratory Service Space11 1
Dietetic Service Space 1
Kitchen 133
Dining Area 116 116
Food serving area 133
Food Preparation 133
Dietary Staff Toilet - Male 12 1:1-15
Dietary Staff Toilet - Female 12 1:1-15
Emergency Service 1
Open plan 1:4 cubicles 1
Observation unit(s) 1:4 cubicles 1:6 beds
Trauma/Cardiac, Emergency surgery, Cystoscopy,
Cast Room
14,33
Intensive Care Units7 1 1
Open plan 1:3 beds33
Patient rooms28 133
Newborn Intensive Care Unit (NICU) 1:4 bassinets17, 33 1 1
Treatment area/room 1
Control station
Staff lounge
Staff Toilet - Male
Staff Toilet - Female 12 1:1-15

76 2025 CALIFORNIA PLUMBING CODE

), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.

PLUMBING FIXTURES AND FIXTURE FITTINGS

TABLE 4-2

[OSHPD 1, 2, 3, 4 & 5] [24] MINIMUM PLUMBING FACILITIES (continued)

SPACE HANDWASHING
FIXTURE
SCRUB
SINKS3
TOILETS BATHTUBS
OR SHOWERS
SERVICE
SINKS1
CLINIC
SINKS
Employee dressing rooms and lockers
Staff Toilet - Male 12 1:1-15
Staff Toilet - Female 12 1:1-15
Exam and treatment rooms 1
Housekeeping room1 1
Laboratories 115
Laundry soiled linen, receiving, holding and sorting 1
Medicine preparation room 119
Morgue and Autopsy 1
Nourishment area 1+12
Nuclear Medicine room 1
Mold room 1
Patient room 1
Patient toilet and bath facilities13 12 1:4 beds 1:12
Central bathing facility 1 1 1
Special bathing facility 1
Nurse Station27 1 112
Newborn/well baby nursery 1:6 bassinets33
Workroom 133
Gastrointestinal endoscopy procedure room 133
Outpatient observation35 1 1
Pediatric and Adolescent Unit toilet room 12,26 126
Pharmacy 125
Staff Toilet - Male 12 1:1-15
Staff Toilet - Female 12 1:1-15
Compounding area for parenteral solutions 133
Postanesthesia care units (PACU) 12 1:16 beds 1
Open plan 1:4 gurney
spaces33
Individual rooms 133
Preoperative patient holding 12 1:16 beds
Protective environment room 133
Protective environment anteroom 120,33
Protective environment toilet room 12 15 15
Psychiatric unit patient room 136 1
Radiological/Imaging Services Space 129
Mammography 1
Interventional imaging 1
Ultrasound8 1 130
Angiography 14, 31
Fluoroscopy8 130
MRI 1
CT Scan 1

), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.

PLUMBING FIXTURES AND FIXTURE FITTINGS

TABLE 4-2

[OSHPD 1, 2, 3, 4 & 5] [24] MINIMUM PLUMBING FACILITIES (continued)

SPACE HANDWASHING
FIXTURE
SCRUB
SINKS3
TOILETS BATHTUBS
OR SHOWERS
SERVICE
SINKS1
CLINIC
SINKS
Class 1 Imaging 1
Staff Toilet18 - Male 12 1:1-15
Staff Toilet18 - Female 12 1:1-15
Rehabilitation Therapy Space
Training toilet 1
Physical therapy service space 1
Occupational therapy service space 1
Speech pathology 1
Infusion Therapy 1
Renal Dialysis Service Space 1:4 stations 1
Bloodborne Infection Isolation Room 1
Nurses’ station 1
Medication dispensing 1
Home training room
1
Repair room11 1 1
Dialysis patient toilet 12 1
Staff lounge
Staff Toilet - Male 1 1:1-15 1 shower
Staff Toilet - Female 1 1:1-15 1 shower
Surgical Service Space 233 1
Staff clothing change areas
Staff Toilet - Male 12 1:1-1537 1 shower
Staff Toilet - Female 12 1:1-1537 1 shower
Clean-up rooms 1
Substerile area 1
Anesthesia workroom 1
Soiled workroom or soiled holding 1 134
Cancer treatment/infusion therapy treatment 1:4 stations
Utility/Work Room
Clean21
1
Soiled22 1 114
Patient beds [Skilled Nursing/Intermediate Care
Facilities][medical model]
1:42 1:4 1:20
Patient toilet and bath facilities13 [Correctional
Treatment Center]
1:82 1:6 1:12
Airborne infection isolation anteroom6 [Correctional
Treatment Center]
16 16 16
Airborne infection isolation anteroom [Correctional
Treatment Center]
1
Protective environment room6 [Correctional Treat-
ment Center]
16 16 16
Protective environment anteroom [Correctional
Treatment Center]
1

Notes: 1 Each department or nursing unit shall be served by a housekeeping room equipped with a service sink. Departments may share service closets provided the departmental services are compatible. A dedicated housekeeping room shall be provided for the following services: Surgical/Catherization, ICU, NICU, nursery, dietary, renal dialysis and outpatient surgery.

78 2025 CALIFORNIA PLUMBING CODE

), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.

PLUMBING FIXTURES AND FIXTURE FITTINGS

2 Conventional spouts and controls on hot-and cold-water supplies are acceptable. Aerators are not permitted. Non-aerating laminar flow devices are permitted. Nourishment areas shall have a handwashing fixture in or immediately accessible from the nourishment area, in addition to a nourishment sink. 3 Scrub sinks shall be located outside of sterile procedure rooms. A minimum of two scrub sinks shall be provided in a surgical unit containing one operating room. Four scrub sinks shall be provided in surgical units containing two operating rooms. One additional scrub sink shall be provided per each additional operating room. 4 The scrub sink is in addition to the required number for surgeries. 5 The following fixtures shall be provided in airborne infection or protective environment rooms of hospitals only: a.Within an adjoining toilet room, a lavatory, a shower containing a seat or a space for a shower chair, and toilet equipped with bedpan flushing attachment with a vacuum breaker.

b.A handwashing fixture within a separate anteroom. 6 The following fixtures shall be provided in isolation rooms of correctional treatment centers only: a.Within an adjoining toilet area, a handwashing fixture, a shower containing a seat or a space for a shower chair, and water closet equipped with bedpan flushing attachment with a vacuum breaker. b.A handwashing fixture within a separate anteroom. 7 Includes burn center spaces, acute respiratory-care service spaces, and coronary-care service spaces. 8 A toilet room with handwashing fixture shall directly adjoin each procedure room. 9 One toilet with lavatory and one shower may serve two labor rooms. 10 One additional scrub sink for each additional cesarean or delivery operating room. 11 Provide emergency eye-wash and shower. 12 Conveniently located for staff use. 13 Fixtures serving individual patient rooms shall not be considered as meeting the required ratios for bedrooms not served by individual adjoining toilet or bath-

rooms. 14 The clinic sink may be deleted if all bedrooms in the nursing unit are provided with adjoining toilets with bedpan flushing devices. 15 Conventional controls on hot-and cold-water supplies are acceptable. The water discharge points shall be 5 inches (127 millimeters) above the fixture rim. Aerators are not permitted. Non-aerating laminar flow devices are permitted. 16 Plumbing fixtures for public use shall be readily accessible and are to be based on 50% of the seating capacity value. Fixture quantity shall be based on Table

422.1 for an occupancy group A2.

17 In a multiple-bed room, every bed position shall be within 20 feet (6 meters) of a hands-free handwashing fixture. Where an individual room concept is used, a handwashing fixture shall be provided within each infant care room. 18 When three or more procedure rooms are provided. 19 If a separate medicine room is provided, the room shall be equipped with a sink in addition to the nurses' station handwashing fixture. Hot-water supplies are optional. 20 Where the patient room can only be accessed through the ante room the handwash fixture may be omitted in the patient room. 21 Handwashing fixtures may be deleted if room is used for storage and holding only. 22 If room is used only for temporary holding of soiled materials, clinic sink and work counter may be omitted. If the flushing-rim clinical sink is eliminated, facilities for cleaning bedpans shall be provided elsewhere. 23 Toilet shall be equipped with a bedpan flushing attachment. 24 Optional services approved by the licensing agency shall comply with the applicable space requirements of OSHPD 1 and 2. 25 Shall be provided in each separate room where open medication is handled. 26 Conveniently accessible throughout the unit. 27 Includes rooms or areas within coronary and intensive-care units and postanethesia recovery rooms. 28 Modular toilet/sink combination units located within a privacy curtain may be used within individual patient space or private room. The toilet fixture shall be completely contained within cabinetry when not in use, and shall be enclosed when flushed. Bedpan washers shall not be permitted in patient bedrooms. 29 In service spaces with procedure rooms that do not have dedicated patient toilets, provide a minimum of one patient toilet room with a separate handwash- ing fixture within the service space. 30 Toilet room shall be accessible from the procedure room. 31 Scrub sink shall be located outside the staff entrance to the procedure room. 32 Not used. 33 Handwashing and scrub sink fixtures shall not be equipped with wrist or elbow blades but shall be equipped with sensor controls, or controls that do not involve contact with the upper extremities. 34 If room is used only for temporary holding of soiled material, clinic sink and work counter may be omitted. 35 A minimum of one separate accessible toilet room shall be provided for the use of patients. Patient toilet room(s) shall be equipped with a handwashing fix- ture and shall be accessible to the observation units(s) from the corridor. Reference CBC, Part 2, Section 1224.39.6. 36 Handwashing stations are required in patient toilet rooms. Handwashing stations are not required in patient bedrooms. 37 Staff toilet facilities located in the surgical unit can be applied to the total fixture count.

), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.

PLUMBING FIXTURES AND FIXTURE FITTINGS

TABLE 4-3 [AGR]

TYPE OF BUILDING
OR OCCUPANCY
WATER CLOSETS
7
(FIXTURES PER PERSON)
URINALS (TROUGH URINAL
TO INDIVIDUAL
URINAL EQUIVALENCE)
MALE
LAVATORIES
(FIXTURES
PER PERSON)
BATHTUBS OR SHOWERS
(FIXTURES PER PERSON)
DRINKING
FOUNTAINS
(FIXTURES
3
PER PERSON)
TYPE OF BUILDING
OR OCCUPANCY
MALE FEMALE MALE FEMALE MALE FEMALE MALE FEMALE MALE FEMALE
Nonindustrial—office
buildings, public build-
ings and similar estab-
lishments
1 1-15
1 1-15
2 16-35
2 16-35
3 36-55
3 36-55
4 56-80
4 56-80
5 81-110
5 81-110
6 111-150
6 111-150
1 additional for each
additional 40 employees
or fraction thereof
Length of
Number of
trough urinal
individual
urinals

24" (610 mm)
_1 _
36" (914 mm)
_2 _
48" (1219 mm)
_2 _
60" (1524 mm)
_3 _
1 1-15
2 16-35
3 36-60
4 61-90
5 91-125
1 additional for each
additional 4 employ-
ees or fraction thereof
1:10 persons per shift
required to shower
Industrial–factories,
warehouses, loft build-
ings and similar estab-
lishments
1 1-15
1 1-15
2 16-35
2 16-35
3 36-55
3 36-55
4 56-80
4 56-80
5 81-110
5 81-110
6 111-150
6 111-150
1 additional for each
additional 40 employees
or fraction thereof
24" (610 mm)
_1 _
36" (914 mm)
_2 _
48" (1219 mm)
_2 _
60" (1524 mm)
_3 _
72" (1829 mm)
4
1 to 100
employees
1 per 10

Over 100 employees 1
additional for each
additional 15 employ-
ees or fraction thereof
1:10 persons per shift
required to shower

Notes: 1 The figures shown are based on one fixture being the minimum required for the number of persons indicated or any fraction thereof. 2 Each water closet shall occupy a separate compartment which shall be equipped with a door, door latch and clothes hook. The door and the walls or partitions between fixtures shall be sufficient to assure privacy. 3 Drinking fountains shall not be located in toilet rooms. 4 Washing facilities shall be reasonably accessible to all employees. 5 Toilet facilities shall be accessible to the employees at all times. Where practicable, toilet facilities should be within 200 feet (61 m) of locations at which workers are reg- ularly employed and should not be more than one floor-to-floor flight of stairs from working areas. 6 Urinals may be installed instead of water closets in toilet rooms to be used only by men provided that the number of water closets shall not be less than two thirds of the minimum number of toilet facilities specified. The length of trough urinals to the equivalent number of individual urinals shall be based on the above table. 7 When there are less than five employees, separate toilet rooms for each sex are not required provided toilet rooms can be locked from the inside and contain at least one water closet. 8 Twenty-four linear inches of wash sink or 18 inches of circular basin, when provided with water outlets for such space, shall be considered equivalent to one lavatory. Exception: The requirements of Table 4-3 do not apply to mobile crews or to normally unattended work locations provided employees at these locations have immediately available transportation to nearby toilet facilities which meet the requirements of Table 4-3.

TABLE 4-4 [DPH]

TYPE OF BUILDING
OR OCCUPANCY2
WATER CLOSETS
(FIXTURES PER PERSON)
URINALS
(FIXTURES PER MALE)
LAVATORIES
(FIXTURES PER PERSON)
BATHTUBS OR SHOWERS
(FIXTURES PER PERSON)
DRINKING FOUNTAINS
(FIXTURES PER PERSON)
Day Use Public
Beaches1,2
Male
Female
1 1-100
1 1-100
No sex designated
1 1-500
Minimum of 2
May be substituted for
up to two-thirds of the
water closets required
Picnic Areas Male
Female
1 1-50
1 1-50
Overnight Use
Public Beaches2
_1 1-7.5 campsites3 _
1 1-7.5 campsites3
May be substituted for
up to one-third of the
water closets required3
1 1-12.5 campsites4
Organized Camps 1 1-153 1 1-15 1 1-156 Minimum 1 per camp

Notes: 1 Toilets shall be located in accordance with actual use patterns on the beach. The reasonable intent of the toilet requirements is that it should apply on the basis of aver- age daily use during periods of peak use. The health officer may determine how many days the population standard may be exceeded. 2 Laundry facilities are not required, but if they are provided, must be a minimum of two laundry trays or a washing machine. 3 Toilet facilities shall not be farther than 400 feet from any lot or campsite. 4 Showers are not required, but it provided, they shall be provided on the indicated ratio. Outdoor rinse-off showers may be cold water only. 5 Toilets shall be located within 300 feet from the living accommodations they serve. 6 Showers shall be provided in the living area or in a centrally located structure. Exception: Intermittent short-term organized camps are not required to provide shower facilities, but it provided, they shall comply with this part.

80 2025 CALIFORNIA PLUMBING CODE

), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.

CALIFORNIA PLUMBING CODE – MATRIX ADOPTION TABLE

Get a plain-English answer with a citation back to this text.

Ask AI about this code
Contents — 2025 California Plumbing Code (Title 24, Part 5)
2025 California Plumbing Code (Title 24, Part 5)
  1. Chapter 1 — GENERAL CODE PROVISIONS
  2. Chapter 2 — DEFINITIONS
  3. Chapter 3 — GENERAL REGULATIONS
  4. Chapter 4 — PLUMBING FIXTURES AND FIXTURE FITTINGS
  5. Chapter 5 — WATER HEATERS
  6. Chapter 6 — WATER SUPPLY AND DISTRIBUTION
  7. Chapter 7 — SANITARY DRAINAGE
  8. Chapter 8 — INDIRECT WASTES
  9. Chapter 9 — VENTS
  10. Chapter 10 — TRAPS AND INTERCEPTORS
  11. Chapter 11 — STORM DRAINAGE
  12. Chapter 12 — FUEL GAS PIPING
  13. Chapter 13 — HEALTH CARE FACILITIES AND MEDICAL GAS AND MEDICA…
  14. Chapter 14 — FIRESTOP PROTECTION
  15. Chapter 15 — ALTERNATE WATER SOURCES FOR NONPOTABLE APPLICATIONS
  16. Chapter 16 — NONPOTABLE RAINWATER CATCHMENT SYSTEMS
  17. Chapter 17 — REFERENCED STANDARDS
  18. Appendix A — RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYS…
  19. Appendix B — EXPLANATORY NOTES ON COMBINATION WASTE AND VENT S…
  20. Appendix C — ALTERNATE PLUMBING SYSTEMS
  21. Appendix D — SIZING STORM WATER DRAINAGE SYSTEMS
  22. Appendix E — MANUFACTURED/MOBILE HOME PARKS AND RECREATIONAL V…
  23. Appendix F — FIREFIGHTER BREATHING AIR REPLENISHMENT SYSTEMS
  24. Appendix G — SIZING OF VENTING SYSTEMS
  25. Appendix H — PRIVATE SEWAGE DISPOSAL SYSTEMS
  26. Appendix I — INSTALLATION STANDARDS
  27. Appendix J — COMBINATION OF INDOOR AND OUTDOOR COMBUSTION AND …
  28. Appendix K — POTABLE RAINWATER CATCHMENT SYSTEMS
  29. Appendix L — SUSTAINABLE PRACTICES
  30. Appendix M — PEAK WATER DEMAND CALCULATOR
  31. Appendix N — IMPACT OF WATER TEMPERATURE ON THE POTENTIAL FOR …
  32. Appendix O — NON-SEWERED SANITATION SYSTEMS
  33. Appendix P — PROFESSIONAL QUALIFICATIONS
  34. Appendix Q — INDOOR HORTICULTURAL FACILITIES
  35. Appendix R — TINY HOUSES
  36. Appendix S — ONSITE STORMWATER TREATMENT SYSTEMS

GoCodebook provides public access, search, citation, multilingual explanation, and practical interpretation of legally adopted building regulations. It is not a substitute for the official ICC or California code publications.