422.11 Employee Lavatories in Food Establishments.

California Plumbing Code (Title 24, Part 5) · 2025 edition · updated 2026-09-10 · California

Italicized text is a California amendment to the model code, as printed in the official publication.

[DPH] Employee lavatories installed in food establishments shall be equipped with an approved single spout capable of providing tempered (100ºF - 115ºF) (37.8ºC - 46.1ºC) run- ning water.

Note: This requirement applies only to commissaries serving mobile food preparation units.

PLUMBING FIXTURES AND FIXTURE FITTINGS

TABLE 422.1 MINIMUM PLUMBING FACILITIES [1]

Each building shall be provided with sanitary facilities, including provisions for persons with disabilities as prescribed by the Department Having Jurisdiction [8] . Table 422.1 applies to new buildings, additions to a building, and changes of occupancy or type in an existing building resulting in increased occupant

load.

For requirements for persons with disabilities, Chapter 11A or 11B of the California Building Code shall be used .

[BSC & DSA-SS] The total occupant load shall be determined in accordance with the California Building Code or Table 4-1 Occupant Load Factor.

Exceptions: (1) [HCD 1-AC & HCD 2] For applications listed in Sections 1.8.2.1.2 and 1.8.2.1.3 regulated by the Department of Housing and Community Development, each building shall be provided with sanitary facilities, including provisions for persons with disabilities as prescribed by the Department. Covered mul- tifamily dwellings required to be accessible to persons with disabilities shall comply with Chapter 11A of the California Building Code. Permanent build- ings in mobilehome parks and special occupancy parks required to be accessible by persons with disabilities, shall comply with Chapter 11B of the California Building Code. (2) [HCD 1] For limited density owner-built rural dwelling sanitary facilities, the type, design and number of facilities as required and approved by the local health official shall be provided to the dwelling sites. It shall not be required that such facilities be located within the dwelling.

persons with disabilities, shall comply with Chapter 11B of the_ California Building Code. (2) [HCD 1] For limited density owner-built rural dwelling sanitary facilities, the type, design and number of facilities as required and approved by the local health official shall be provided to the dwelling sites. It shall not be required that such facilities be located within the dwelling.

TYPE OF
OCCUPANCY2
WATER CLOSETS
(FIXTURES PER PERSON)3
URINALS
(FIXTURES
PER
PERSON)4
LAVATORIES
(FIXTURES PER PERSON)5
BATHTUBS
OR
SHOWERS
(FIXTURES
PER
PERSON)
DRINKING
FOUNTAINS/
FACILITIES
(FIXTURES
PER
PERSON)
OTHER6, 7
A-1 Assembly occupancy
(fixed or permanent seat-
ing)- theaters, concert
halls, and auditoriums
Male
1: 1-100
2: 101-200
3: 201-400
Female
1: 1-25
2: 26-50
3: 51-100
4: 101-200
6: 201-300
8: 301-400
Male
1: 1-200
2: 201-300
3: 301-400
4: 401-600
Male
1: 1-200
2: 201-400
3: 401-600
4: 601-750
Female
1: 1-100
2: 101-200
4: 201-300
5: 301-500
6: 501-750
––
1: 1-250
2: 251-500
3: 501-750
1 service
sink or
laundry sink
A-1 Assembly occupancy
(fixed or permanent seat-
ing)- theaters, concert
halls, and auditoriums
Over 400, add 1 fixture for
each additional 500 males
and 1 fixture for each
additional 125 females.
Over 400, add 1 fixture for
each additional 500 males
and 1 fixture for each
additional 125 females.
Over 600,
add 1 fixture
for each
additional
300 males.
Over 750, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
Over 750, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
Over 750, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
Over 750,
add 1 fixture
for each
additional
500 persons.
Over 750,
add 1 fixture
for each
additional
500 persons.
A-2 Assembly occu-
pancy- restaurants, pubs,
lounges, nightclubs and
banquet halls
Male
1: 1-50
2: 51-150
3: 151-300
4: 301-400
Female
1: 1-25
2: 26-50
3: 51-100
4: 101-200
6: 201-300
8: 301-400
Male
1: 1-200
2: 201-300
3: 301-400
4: 401-600
Male
1: 1-150
2: 151-200
3: 201-400
Female
1: 1-150
2: 151-200
4: 201-400
––
1: 1-250
2: 251-500
3: 501-750
1 service
sink or
laundry sink
A-2 Assembly occu-
pancy- restaurants, pubs,
lounges, nightclubs and
banquet halls
Over 400, add 1 fixture for
each additional 250 males
and 1 fixture for each 125
females.
Over 400, add 1 fixture for
each additional 250 males
and 1 fixture for each 125
females.
Over 600,
add 1 fixture
for each
additional
300 males.
Over 400, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females
Over 400, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females
Over 400, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females
Over 750,
add 1 fixture
for each
additional
500 persons.
Over 750,
add 1 fixture
for each
additional
500 persons.
A-3 Assembly occupancy
(typical without fixed or
permanent seating)-
arcades, places of wor-
ship, museums, libraries,
lecture halls, gymnasiums
(without spectator seat-
ing), indoor pools (with-
out spectator seating)
Male
1: 1-100
2: 101-200
3: 201-400
Female
1: 1-25
2: 26-50
3: 51-100
4: 101-200
6: 201-300
8: 301-400
Male
1: 1-100
2: 101-200
3: 201-400
4: 401-600
Male
1: 1-200
2: 201-400
3: 401-600
4: 601-750
Female
1: 1-100
2: 101-200
4: 201-300
5: 301-500
6: 501-750
––
1: 1-250
2: 251-500
3: 501-750
1 service
sink or
laundry sink
A-3 Assembly occupancy
(typical without fixed or
permanent seating)-
arcades, places of wor-
ship, museums, libraries,
lecture halls, gymnasiums
(without spectator seat-
ing), indoor pools (with-
out spectator seating)
Over 400, add 1 fixture for
each additional 500 males
and 1 fixture for each
additional 125 females.
Over 400, add 1 fixture for
each additional 500 males
and 1 fixture for each
additional 125 females.
Over 600,
add 1 fixture
for each
additional
300 males.
Over 750, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
Over 750, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
Over 750, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
Over 750,
add 1 fixture
for each
additional
500 persons.
Over 750,
add 1 fixture
for each
additional
500 persons.

70 2025 CALIFORNIA PLUMBING CODE

PLUMBING FIXTURES AND FIXTURE FITTINGS

TABLE 422.1 MINIMUM PLUMBING FACILITIES [1] (continued)

TYPE OF
OCCUPANCY2
WATER CLOSETS
(FIXTURES PER PERSON)3
URINALS
(FIXTURES
PER
PERSON)4
LAVATORIES
(FIXTURES PER PERSON)5
BATHTUBS
OR
SHOWERS
(FIXTURES
PER
PERSON)
DRINKING
FOUNTAINS/
FACILITIES
(FIXTURES
PER
PERSON)
OTHER6, 7
A-4 Assembly occupancy
(indoor activities or sport-
ing events with spectator
seating)- swimming
pools, skating rinks, are-
nas, and gymnasiums
Male
1: 1-100
2: 101-200
3: 201-400
Female
1: 1-25
2: 26-50
3: 51-100
4: 101-200
6: 201-300
8: 301-400
Male
1: 1-100
2: 101-200
3: 201-400
4: 401-600
Male
1: 1-200
2: 201-400
3: 401-750
Female
1: 1-100
2: 101-200
4: 201-300
5: 301-500
6: 501-750
–– 1: 1-250
2: 251-500
3: 501-750
1 service
sink or
laundry sink
A-4 Assembly occupancy
(indoor activities or sport-
ing events with spectator
seating)- swimming
pools, skating rinks, are-
nas, and gymnasiums
Over 400, add 1 fixture for
each additional 500 males
and 1 fixture for each addi-
tional 125 females.
Over 400, add 1 fixture for
each additional 500 males
and 1 fixture for each addi-
tional 125 females.
Over 600,
add 1 fixture
for each
additional
300 males.
Over 750, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
Over 750, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
Over 750, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
Over 750,
add 1 fixture
for each
additional
500 persons.
Over 750,
add 1 fixture
for each
additional
500 persons.
A-5Assembly occupancy
(outdoor activities or
sporting events)- amuse-
ment parks, grandstands
and stadiums
Male
1: 1-100
2: 101-200
3: 201-400
Female
1: 1-25
2: 26-50
3: 51-100
4: 101-200
6: 201-300
8: 301-400
Male
1: 1-100
2: 101-200
3: 201-400
4: 401-600
Male
1: 1-200
2: 201-400
3: 401-750
Female
1: 1-100
2: 101-200
4: 201-300
5: 301-500
6: 501-750
–– 1: 1-250
2: 251-500
3: 501-750
1 service
sink or
laundry sink
A-5Assembly occupancy
(outdoor activities or
sporting events)- amuse-
ment parks, grandstands
and stadiums
Over 400, add 1 fixture for
each additional 500 males
and 1 fixture for each addi-
tional 125 females.
Over 400, add 1 fixture for
each additional 500 males
and 1 fixture for each addi-
tional 125 females.
Over 600,
add 1 fixture
for each
additional
300 males.
Over 750, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
Over 750, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
Over 750, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
Over 750,
add 1 fixture
for each
additional
500 persons.
Over 750,
add 1 fixture
for each
additional
500 persons.
B Business occupancy
(office, professional or
service type transactions)-
banks, vet clinics, hospi-
tals, car wash, banks,
beauty salons, ambulatory
health care facilities, laun-
dries and dry cleaning,
educational institutions
(above high school), or
training facilities not
located within school, post
offices and printing shops
Male
1: 1-50
2: 51-100
3: 101-200
4: 201-400
Female
1: 1-15
2: 16-30
3: 31-50
4: 51-100
8: 101-200
11: 201-400
Male
1: 1-100
2: 101-200
3: 201-400
4: 401-600
Male
1: 1-75
2: 76-150
3: 151-200
4: 201-300
5: 301-400
Female
1: 1-50
2: 51-100
3: 101-150
4: 151-200
5: 201-300
6: 301-400
–– 1 per 150 1 service
sink or
laundry sink
B Business occupancy
(office, professional or
service type transactions)-
banks, vet clinics, hospi-
tals, car wash, banks,
beauty salons, ambulatory
health care facilities, laun-
dries and dry cleaning,
educational institutions
(above high school), or
training facilities not
located within school, post
offices and printing shops
Over 400, add 1 fixture
for each additional 500
males and 1 fixture for
each additional 150
females.
Over 400, add 1 fixture
for each additional 500
males and 1 fixture for
each additional 150
females.
Over 600,
add 1 fixture
for each
additional
300 males.
Over 400, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
Over 400, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
Over 400, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
Over 400, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
Over 400, add 1 fixture for
each additional 250 males
and 1 fixture for each
additional 200 females.
E Educational occupancy-
private or public schools
Male
1 per 50
Female
1 per 30
Male
1 per 100
Male
1 per 40
Female
1 per 40
–– 1 per 150 1 service
sink or
laundry sink
F1, F2 Factory or Indus-
trial occupancy-fabricat-
ing or assembly work
Male
1: 1-50
2: 51-75
3: 76-100
Female
1: 1-50
2: 51-75
3: 76-100
–– Male
1: 1-50
2: 51-75
3: 76-100
Female
1: 1-50
2: 51-75
3: 76-100
1 shower for
each 15
persons
exposed to
excessive
heat or to
skin con-
tamination
with poison-
ous, infec-
tious or
irritating
material
1: 1-250
2: 251-500
3: 501-750
1 service
sink or
laundry sink
TYPE OF
OCCUPANCY2
WATER CLOSETS
(FIXTURES PER PERSON)3
URINALS
(FIXTURES
PER
PERSON)4
LAVATORIES
(FIXTURES PER PERSON)5
BATHTUBS
OR
SHOWERS
(FIXTURES
PER
PERSON)
DRINKING
FOUNTAINS/
FACILITIES
(FIXTURES
PER
PERSON)
OTHER6, 7
F1, F2 Factory or Indus-
trial occupancy-fabricat-
ing or assembly work
Over 100, add 1 fixture
for each additional 40 per-
sons.
Over 100, add 1 fixture
for each additional 40 per-
sons.
–– Over 100, add 1 fixture for
each additional 40 per-
sons.
Over 100, add 1 fixture for
each additional 40 per-
sons.
Over 100, add 1 fixture for
each additional 40 per-
sons.
Over 750,
add 1 fixture
for each
additional
500 persons.
Over 750,
add 1 fixture
for each
additional
500 persons.

PLUMBING FIXTURES AND FIXTURE FITTINGS

TABLE 422.1

MINIMUM PLUMBING F FACILITIES1 (continued)
TYPE OF
OCCUPANCY2
TYPE OF
OCCUPANCY2
WATER CLOSETS
(FIXTURES PER PERSON)3
WATER CLOSETS
(FIXTURES PER PERSON)3
URINALS
(FIXTURES
PER
PERSON)4
LAVATORIES
(FIXTURES PER PERSON)5
LAVATORIES
(FIXTURES PER PERSON)5
BATHTUBS
OR
SHOWERS
(FIXTURES
PER
PERSON)
DRINKING
FOUNTAINS/
FACILITIES
(FIXTURES
PER
PERSON)
OTHER6, 7
I-1 Institutional occu-
pancy (houses more than
16 persons on a 24-hour
basis)- substance abuse
centers, assisted living,
group homes, or residen-
tial facilities
I-1 Institutional occu-
pancy (houses more than
16 persons on a 24-hour
basis)- substance abuse
centers, assisted living,
group homes, or residen-
tial facilities
Male
1 per 15
Female
1 per 15
–– Male
1 per 15
Female
1 per 15
1 per 8 1 per 150 1 service
sink or
laundry sink
I-2 Institu-
tional occu-
pancy-medi
cal, psychi-
atric, surgi-
cal or
nursing
homes
Hospitals
and nursing
homes-indi-
vidual
rooms and
ward room
1 per room 1 per room –– 1 per room 1 per room 1 per room 1 per 150 1 service
sink or
laundry sink
I-2 Institu-
tional occu-
pancy-medi
cal, psychi-
atric, surgi-
cal or
nursing
homes
Hospitals
and nursing
homes-indi-
vidual
rooms and
ward room
1 per 8 patients 1 per 8 patients –– 1 per 10 patients 1 per 10 patients 1 per 20
patients
1 per 20
patients
1 per 20
patients
I-2 Institu-
tional occu-
pancy-medi
cal, psychi-
atric, surgi-
cal or
nursing
homes
Hospital
Waiting or
Visitor
Rooms
1 per room 1 per room –– 1 per room 1 per room –– 1 per room ––
I-2 Institu-
tional occu-
pancy-medi
cal, psychi-
atric, surgi-
cal or
nursing
homes
Employee
Use
Male
1: 1-15
2: 16-35
3: 36-55
Female
1: 1-15
3: 16-35
4: 36-55
–– Male
1 per 40
Female
1 per 40
–– –– ––
I-2 Institu-
tional occu-
pancy-medi
cal, psychi-
atric, surgi-
cal or
nursing
homes
Employee
Use
Over 55, add 1 fixture for
each additional 40 persons.
Over 55, add 1 fixture for
each additional 40 persons.
Over 55, add 1 fixture for
each additional 40 persons.
Over 55, add 1 fixture for
each additional 40 persons.
Over 55, add 1 fixture for
each additional 40 persons.
Over 55, add 1 fixture for
each additional 40 persons.
Over 55, add 1 fixture for
each additional 40 persons.
Over 55, add 1 fixture for
each additional 40 persons.
I-3Institu-
tional occu-
pancy
(houses
more than 5
people)
Prisons 1 per cell 1 per cell –– 1 per cell 1 per cell 1 per 20 1 per cell
block/floor
––
I-3Institu-
tional occu-
pancy
(houses
more than 5
people)
Correctional
facilities or
juvenile
center
1 per 8 1 per 8 –– 1 per 10 1 per 10 1 per 8 1 per floor 1 service
sink or
laundry sink
I-3Institu-
tional occu-
pancy
(houses
more than 5
people)
Employee
Use
Male
1: 1-15
2: 16-35
3: 36-55
Female
1: 1-15
3: 16-35
4: 36-55
–– Male
1 per 40
Female
1 per 40
–– 1 per 150 ––
I-3Institu-
tional occu-
pancy
(houses
more than 5
people)
Employee
Use
Over 55, add 1 fixture for
each additional 40 persons.
Over 55, add 1 fixture for
each additional 40 persons.
Over 55, add 1 fixture for
each additional 40 persons.
Over 55, add 1 fixture for
each additional 40 persons.
Over 55, add 1 fixture for
each additional 40 persons.
Over 55, add 1 fixture for
each additional 40 persons.
Over 55, add 1 fixture for
each additional 40 persons.
Over 55, add 1 fixture for
each additional 40 persons.
I-4Institutional occu-
pancy (any age that
receives care for less than
24 hours)
I-4Institutional occu-
pancy (any age that
receives care for less than
24 hours)
Male
1: 1-15
2: 16-35
3: 36-55
Female
1: 1-15
3: 16-35
4: 36-55
–– Male
1 per 40
Female
1 per 40
–– 1 per 150 1 service
sink or
laundry sink
I-4Institutional occu-
pancy (any age that
receives care for less than
24 hours)
I-4Institutional occu-
pancy (any age that
receives care for less than
24 hours)
Over 55, add 1 fixture for
each additional 40 per-
sons.
Over 55, add 1 fixture for
each additional 40 per-
sons.
Over 55, add 1 fixture for
each additional 40 per-
sons.
Over 55, add 1 fixture for
each additional 40 per-
sons.
Over 55, add 1 fixture for
each additional 40 per-
sons.
Over 55, add 1 fixture for
each additional 40 per-
sons.
Over 55, add 1 fixture for
each additional 40 per-
sons.
Over 55, add 1 fixture for
each additional 40 per-
sons.
M Mercantile occupancy
(the sale of merchandise
and accessible to the pub-
lic)
M Mercantile occupancy
(the sale of merchandise
and accessible to the pub-
lic)
Male
1: 1-100
2: 101-200
3: 201-400
Female
1: 1-100
2: 101-200
4: 201-300
6: 301-400
Male
0: 1-200
1: 201-400
Male
1: 1-200
2: 201-400
Female
1: 1-200
2: 201-300
3: 301-400
–– 1: 1-250
2: 251-500
3: 501-750
1 service
sink or
laundry sink
MINIMUM PLUMBING F FACILITIES1 (continued)
M Mercantile occupancy
(the sale of merchandise
and accessible to the pub-
lic)
M Mercantile occupancy
(the sale of merchandise
and accessible to the pub-
lic)
Over 400, add 1 fixture for
each additional 500 males
and 1 fixture for each 200
females.
Over 400, add 1 fixture for
each additional 500 males
and 1 fixture for each 200
females.
Over 400,
add 1 fixture
for each
additional
500 males.
Over 400, add 1 fixture for
each additional 500 males
and 1 fixture for each 400
females.
Over 400, add 1 fixture for
each additional 500 males
and 1 fixture for each 400
females.
–– Over 750,
add 1 fixture
for each
additional
500 persons.
––

72 2025 CALIFORNIA PLUMBING CODE

PLUMBING FIXTURES AND FIXTURE FITTINGS

TABLE 422.1

MINIMUM PLUMBING F FACILITIES1 (continued)
TYPE OF
OCCUPANCY2
TYPE OF
OCCUPANCY2
WATER CLOSETS
(FIXTURES PER PERSON)3
WATER CLOSETS
(FIXTURES PER PERSON)3
URINALS
(FIXTURES
PER
PERSON)4
LAVATORIES
(FIXTURES PER PERSON)5
LAVATORIES
(FIXTURES PER PERSON)5
BATHTUBS
OR
SHOWERS
(FIXTURES
PER
PERSON)
DRINKING
FOUNTAINS/
FACILITIES
(FIXTURES
PER
PERSON)
OTHER6, 7
R-1 Residential occu-
pancy (minimal stay)-
hotels, motels, bed and
breakfast homes
R-1 Residential occu-
pancy (minimal stay)-
hotels, motels, bed and
breakfast homes
1 per sleeping room 1 per sleeping room –– 1 per sleeping room 1 per sleeping room 1 per sleep-
ing room
–– 1 service sink
or
laundry sink
R-2 Resi-
dential
occupancy
(long-term
or perma-
nent)
Dormitories Male
1 per 10
Female
1 per 8
Male
1 per 25
Male
1 per 12
Female
1 per 12
1 per 8 1 per 150 1 service
sink or
laundry sink
R-2 Resi-
dential
occupancy
(long-term
or perma-
nent)
Dormitories Add 1 fixture for each
additional 25 males and 1
fixture for each additional
20 females.
Add 1 fixture for each
additional 25 males and 1
fixture for each additional
20 females.
Over 150,
add 1 fixture
for each
additional
50 males.
Add 1 fixture for each
additional 20 males and 1
fixture for each additional
15 females.
Add 1 fixture for each
additional 20 males and 1
fixture for each additional
15 females.
Add 1 fixture for each
additional 20 males and 1
fixture for each additional
15 females.
Add 1 fixture for each
additional 20 males and 1
fixture for each additional
15 females.
Add 1 fixture for each
additional 20 males and 1
fixture for each additional
15 females.
R-2 Resi-
dential
occupancy
(long-term
or perma-
nent)
Employee
Use
Male
1: 1-15
2: 16-35
3: 36-55
Female
1: 1-15
3: 16-35
4: 36-55
–– Male
1 per 40
Female
1 per 40
–– –– ––
R-2 Resi-
dential
occupancy
(long-term
or perma-
nent)
Employee
Use
Over 55, add 1 fixture for
each additional 40 persons
Over 55, add 1 fixture for
each additional 40 persons
Over 55, add 1 fixture for
each additional 40 persons
Over 55, add 1 fixture for
each additional 40 persons
Over 55, add 1 fixture for
each additional 40 persons
Over 55, add 1 fixture for
each additional 40 persons
Over 55, add 1 fixture for
each additional 40 persons
Over 55, add 1 fixture for
each additional 40 persons
R-2 Resi-
dential
occupancy
(long-term
or perma-
nent)
Apartment
house/unit
1 per apartment 1 per apartment –– 1 per apartment 1 per apartment 1 per
apartment
–– 1 kitchen sink
per apartment.
1 laundry sink
or 1 automatic
clothes washer
connection
per unit or 1
laundry sink or
1 automatic
clothes washer
connection for
each 12 units
R-3 Residential occu-
pancy (long-term or per-
manent in nature) for
more than 5 but does not
exceed 16 occupants)
R-3 Residential occu-
pancy (long-term or per-
manent in nature) for
more than 5 but does not
exceed 16 occupants)
Male
1 per 10
Female
1 per 8
–– Male
1 per 12
Female
1 per 12
1 per 8 1 per 150 1 service
sink or
laundry sink
R-3 Residential occu-
pancy (long-term or per-
manent in nature) for
more than 5 but does not
exceed 16 occupants)
R-3 Residential occu-
pancy (long-term or per-
manent in nature) for
more than 5 but does not
exceed 16 occupants)
Add 1 fixture for each
additional 25 males and 1
fixture for each additional
20 females.
Add 1 fixture for each
additional 25 males and 1
fixture for each additional
20 females.
Add 1 fixture for each
additional 25 males and 1
fixture for each additional
20 females.
Add 1 fixture for each
additional 20 males and 1
fixture for each additional
15 females.
Add 1 fixture for each
additional 20 males and 1
fixture for each additional
15 females.
Add 1 fixture for each
additional 20 males and 1
fixture for each additional
15 females.
Add 1 fixture for each
additional 20 males and 1
fixture for each additional
15 females.
Add 1 fixture for each
additional 20 males and 1
fixture for each additional
15 females.
R-3 Residential occu-
pancy (one and two fam-
ily dwellings)
R-3 Residential occu-
pancy (one and two fam-
ily dwellings)
1 per one and two family
dwelling
1 per one and two family
dwelling
–– 1 per one and two family
dwelling
1 per one and two family
dwelling
1 per one
and two
family
dwelling
–– 1 kitchen
sink and
1 automatic
clothes washer
connection per
one and two
family
dwelling
R-4 Residential occu-
pancy (residential care or
assisted living)
R-4 Residential occu-
pancy (residential care or
assisted living)
Male
1 per 10
Female
1 per 8
–– Male
1 per 12
Female
1 per 12
1 per 8 1 per 150 1 service
sink or
laundry sink
MINIMUM PLUMBING F FACILITIES1 (continued)
R-4 Residential occu-
pancy (residential care or
assisted living)
R-4 Residential occu-
pancy (residential care or
assisted living)
Add 1 fixture for each
additional 25 males and 1
fixture for each additional
20 females.
Add 1 fixture for each
additional 25 males and 1
fixture for each additional
20 females.
Add 1 fixture for each
additional 25 males and 1
fixture for each additional
20 females.
Add 1 fixture for each
additional 20 males and 1
fixture for each additional
15 females.
Add 1 fixture for each
additional 20 males and 1
fixture for each additional
15 females.
Add 1 fixture for each
additional 20 males and 1
fixture for each additional
15 females.
Add 1 fixture for each
additional 20 males and 1
fixture for each additional
15 females.
Add 1 fixture for each
additional 20 males and 1
fixture for each additional
15 females.

PLUMBING FIXTURES AND FIXTURE FITTINGS

TABLE 422.1

MINIMUM PLUMBING F FACILITIES1 (continued)
TYPE OF
OCCUPANCY2
WATER CLOSETS
(FIXTURES PER PERSON)3
WATER CLOSETS
(FIXTURES PER PERSON)3
URINALS
(FIXTURES
PER
PERSON)4
LAVATORIES
(FIXTURES PER PERSON)5
LAVATORIES
(FIXTURES PER PERSON)5
BATHTUBS
OR
SHOWERS
(FIXTURES
PER
PERSON)
DRINKING
FOUNTAINS/
FACILITIES
(FIXTURES
PER
PERSON)
OTHER6, 7
S-1, S-2 Storage occu-
pancy-storage of goods,
warehouse, aircraft
hanger, food products,
appliances
Male
1: 1-100
2: 101-200
3: 201-400
Female
1: 1-100
2: 101-200
3: 201-400
––
Male
1: 1-200
2: 201-400
3: 401-750
Female
1: 1-200
2: 201-400
3: 401-750
––
1: 1-250
2: 251-500
3: 501-750
1 service
sink or
laundry sink
S-1, S-2 Storage occu-
pancy-storage of goods,
warehouse, aircraft
hanger, food products,
appliances
Over 400, add 1 fixture for
each additional 500 males
and 1 fixture for each
additional 150 females.
Over 400, add 1 fixture for
each additional 500 males
and 1 fixture for each
additional 150 females.
Over 400, add 1 fixture for
each additional 500 males
and 1 fixture for each
additional 150 females.
Over 750, add 1 fixture for
each additional 500 per-
sons.
Over 750, add 1 fixture for
each additional 500 per-
sons.
Over 750, add 1 fixture for
each additional 500 per-
sons.
Over 750,
add 1 fix-
ture for
each addi-
tional 500
persons.
Over 750,
add 1 fix-
ture for
each addi-
tional 500
persons.

N otes: 1 The figures shown are based upon one fixture being the minimum required for the number of persons indicated or any fraction thereof. 2 A restaurant is defined as a business that sells food to be consumed on the premises. a. The number of occupants for a drive-in restaurant shall be considered as equal to the number of parking stalls. b. Hand-washing facilities shall be available in the kitchen for employees. 3 The total number of required water closets for females shall be not less than the total number of required water closets and urinals for males. [BSC] This requirement shall not apply when single occupancy toilet facilities are provided for each sex in an A or E occupancy with an occupant load of less than 50. Either

a. The required urinal shall be permitted to be omitted or b. If installed, the urinal shall not require a second water closet to be provided for the female. 4 For each urinal added in excess of the minimum required, one water closet shall be permitted to be deducted. The number of water closets shall not be reduced to less than two-thirds of the minimum requirement. 5 Metering or self-closing faucets shall be installed on lavatories intended to serve the transient public. 6 Service sinks shall not be required for non-residential occupancies with an occupant load of 15 or less. 7 For business and mercantile occupancies, one common service sink shall be permitted when accessible to all businesses and mercantile within 300 feet (91 440 mm) and within the same story. 8 [BSC, DSA-AC, DSA-SS, HCD 1 & HCD 2, OSHPD 1, 2, 3, 4 & 5] In accordance with Sections 1.8.7 and 301.3, the Authority Having Jurisdiction may approve alternative design criteria when determining the minimum number of plumbing fixtures.

74 2025 CALIFORNIA PLUMBING CODE

PLUMBING FIXTURES AND FIXTURE FITTINGS

TABLE 4-1 OCCUPANT LOAD FACTOR: [BSC & DSA-SS]

**FUNCTION OF SPACE* **** OCCUPANT
LOAD FACTOR
(square feet)
Assembly_ - without fixed seats_
Auditorium, convention and dance hall, lodge, stage, indoor sport/spectator event, worship, arcade, gaming
(standing space)
11
Waiting, terminal (portable seating space) 15
Conference, dining/drinking, lounge (portable seating/table space) 30
Gallery, museum, exhibit (standing space) 30
Assembly_ – with fixed seats_ See CBC 1004.6
Use 50% of the fixed
seating value
Business_ (office, sales/soliciting, administration, food processing, courtroom, ambulatory clinic)_ 150
See CBC 1004.8
Dormitory 50
Day care 35
Education_ (classroom)_
Through 12th grade
30
Education_ (classroom)_
Beyond 12th grade
50
Exercise_ (fitness)_ 50
Industrial_ (fabrication, foundry, workshop, component assembly, repair)_ 500
Kitchen/food prep_ (commercial)_ 50
Laboratory
Educational
50
Laboratory
Non-educational
100
Library 50
Mercantile_ (wholesale, retail)_ 100
Mall building_ (covered/open)_ See CBC 402.8.2
Residential_ (long term: central toilet facilities)_ 200
Warehouse
Storage portions
4000
Warehouse
Distribution portions (selecting, processing, packing, receiving, shipping)
500
  • Any uses not specifically listed shall be based on similar uses listed in this table.

** For a building or space with mixed occupancies, use appropriate occupancy group for each area (for example, a school may have an “A” occupancy for the gymnasium, a “B” occupancy for the office, an “E” occupancy for the classrooms, etc.). Accessory areas such as, but not limited to, hallways/corri- dors, stairways, ramps, toilet rooms, mechanical rooms, closets and fixed equipment, may be excluded.

PLUMBING FIXTURES AND FIXTURE FITTINGS

TABLE 4-2

[OSHPD 1, 2, 3, 4 & 5] [24] MINIMUM PLUMBING FACILITIES

SPACE HANDWASHING
FIXTURE
SCRUB
SINKS3
TOILETS BATHTUBS
OR SHOWERS
SERVICE
SINKS1
CLINIC
SINKS
Administration Lobby
Public Toilet - Male 12 1
Public Toilet - Female 12 1
Airborne infection isolation room 120
Airborne infection isolation treatment/exam room 120
Airborne infection isolation anteroom 1
Airborne infection isolation toilet room 12 15 15
Cardiac Catheterization procedure room 14, 33
Central Sterile Supply 115
Cesarean/Delivery Service Space
Labor Rooms 133 19 19
Recovery Room 133 1
Drug distribution station 1
Cesarean operating room 210, 33
Delivery room 110, 33
LDR or LDRP room 133 1 1
Staff lounge
Staff Toilet - Male 12 1:1-15
Staff Toilet - Female 12 1:1-15
Waiting area/room
Public Toilet - Male 12 1
Public Toilet - Female 12 1
Clinical Laboratory Service Space11 1
Dietetic Service Space 1
Kitchen 133
Dining Area 116 116
Food serving area 133
Food Preparation 133
Dietary Staff Toilet - Male 12 1:1-15
Dietary Staff Toilet - Female 12 1:1-15
Emergency Service 1
Open plan 1:4 cubicles 1
Observation unit(s) 1:4 cubicles 1:6 beds
Trauma/Cardiac, Emergency surgery, Cystoscopy,
Cast Room
14,33
Intensive Care Units7 1 1
Open plan 1:3 beds33
Patient rooms28 133
Newborn Intensive Care Unit (NICU) 1:4 bassinets17, 33 1 1
Treatment area/room 1
Control station
Staff lounge
Staff Toilet - Male
Staff Toilet - Female 12 1:1-15

76 2025 CALIFORNIA PLUMBING CODE

PLUMBING FIXTURES AND FIXTURE FITTINGS

TABLE 4-2

[OSHPD 1, 2, 3, 4 & 5] [24] MINIMUM PLUMBING FACILITIES (continued)

SPACE HANDWASHING
FIXTURE
SCRUB
SINKS3
TOILETS BATHTUBS
OR SHOWERS
SERVICE
SINKS1
CLINIC
SINKS
Employee dressing rooms and lockers
Staff Toilet - Male 12 1:1-15
Staff Toilet - Female 12 1:1-15
Exam and treatment rooms 1
Housekeeping room1 1
Laboratories 115
Laundry soiled linen, receiving, holding and sorting 1
Medicine preparation room 119
Morgue and Autopsy 1
Nourishment area 1+12
Nuclear Medicine room 1
Mold room 1
Patient room 1
Patient toilet and bath facilities13 12 1:4 beds 1:12
Central bathing facility 1 1 1
Special bathing facility 1
Nurse Station27 1 112
Newborn/well baby nursery 1:6 bassinets33
Workroom 133
Gastrointestinal endoscopy procedure room 133
Outpatient observation35 1 1
Pediatric and Adolescent Unit toilet room 12,26 126
Pharmacy 125
Staff Toilet - Male 12 1:1-15
Staff Toilet - Female 12 1:1-15
Compounding area for parenteral solutions 133
Postanesthesia care units (PACU) 12 1:16 beds 1
Open plan 1:4 gurney
spaces33
Individual rooms 133
Preoperative patient holding 12 1:16 beds
Protective environment room 133
Protective environment anteroom 120,33
Protective environment toilet room 12 15 15
Psychiatric unit patient room 136 1
Radiological/Imaging Services Space 129
Mammography 1
Interventional imaging 1
Ultrasound8 1 130
Angiography 14, 31
Fluoroscopy8 130
MRI 1
CT Scan 1

PLUMBING FIXTURES AND FIXTURE FITTINGS

TABLE 4-2

[OSHPD 1, 2, 3, 4 & 5] [24] MINIMUM PLUMBING FACILITIES (continued)

SPACE HANDWASHING
FIXTURE
SCRUB
SINKS3
TOILETS BATHTUBS
OR SHOWERS
SERVICE
SINKS1
CLINIC
SINKS
Class 1 Imaging 1
Staff Toilet18 - Male 12 1:1-15
Staff Toilet18 - Female 12 1:1-15
Rehabilitation Therapy Space
Training toilet 1
Physical therapy service space 1
Occupational therapy service space 1
Speech pathology 1
Infusion Therapy 1
Renal Dialysis Service Space 1:4 stations 1
Bloodborne Infection Isolation Room 1
Nurses’ station 1
Medication dispensing 1
Home training room
1
Repair room11 1 1
Dialysis patient toilet 12 1
Staff lounge
Staff Toilet - Male 1 1:1-15 1 shower
Staff Toilet - Female 1 1:1-15 1 shower
Surgical Service Space 233 1
Staff clothing change areas
Staff Toilet - Male 12 1:1-1537 1 shower
Staff Toilet - Female 12 1:1-1537 1 shower
Clean-up rooms 1
Substerile area 1
Anesthesia workroom 1
Soiled workroom or soiled holding 1 134
Cancer treatment/infusion therapy treatment 1:4 stations
Utility/Work Room
Clean21
1
Soiled22 1 114
Patient beds [Skilled Nursing/Intermediate Care
Facilities][medical model]
1:42 1:4 1:20
Patient toilet and bath facilities13 [Correctional
Treatment Center]
1:82 1:6 1:12
Airborne infection isolation anteroom6 [Correctional
Treatment Center]
16 16 16
Airborne infection isolation anteroom [Correctional
Treatment Center]
1
Protective environment room6 [Correctional Treat-
ment Center]
16 16 16
Protective environment anteroom [Correctional
Treatment Center]
1

Notes: 1 Each department or nursing unit shall be served by a housekeeping room equipped with a service sink. Departments may share service closets provided the departmental services are compatible. A dedicated housekeeping room shall be provided for the following services: Surgical/Catherization, ICU, NICU, nursery, dietary, renal dialysis and outpatient surgery.

78 2025 CALIFORNIA PLUMBING CODE

PLUMBING FIXTURES AND FIXTURE FITTINGS

2 Conventional spouts and controls on hot-and cold-water supplies are acceptable. Aerators are not permitted. Non-aerating laminar flow devices are permitted. Nourishment areas shall have a handwashing fixture in or immediately accessible from the nourishment area, in addition to a nourishment sink. 3 Scrub sinks shall be located outside of sterile procedure rooms. A minimum of two scrub sinks shall be provided in a surgical unit containing one operating room. Four scrub sinks shall be provided in surgical units containing two operating rooms. One additional scrub sink shall be provided per each additional operating room. 4 The scrub sink is in addition to the required number for surgeries. 5 The following fixtures shall be provided in airborne infection or protective environment rooms of hospitals only: a.Within an adjoining toilet room, a lavatory, a shower containing a seat or a space for a shower chair, and toilet equipped with bedpan flushing attachment with a vacuum breaker.

b.A handwashing fixture within a separate anteroom. 6 The following fixtures shall be provided in isolation rooms of correctional treatment centers only: a.Within an adjoining toilet area, a handwashing fixture, a shower containing a seat or a space for a shower chair, and water closet equipped with bedpan flushing attachment with a vacuum breaker. b.A handwashing fixture within a separate anteroom. 7 Includes burn center spaces, acute respiratory-care service spaces, and coronary-care service spaces. 8 A toilet room with handwashing fixture shall directly adjoin each procedure room. 9 One toilet with lavatory and one shower may serve two labor rooms. 10 One additional scrub sink for each additional cesarean or delivery operating room. 11 Provide emergency eye-wash and shower. 12 Conveniently located for staff use. 13 Fixtures serving individual patient rooms shall not be considered as meeting the required ratios for bedrooms not served by individual adjoining toilet or bath-

h lavatory and one shower may serve two labor rooms._ 10 One additional scrub sink for each additional cesarean or delivery operating room. 11 Provide emergency eye-wash and shower. 12 Conveniently located for staff use. 13 Fixtures serving individual patient rooms shall not be considered as meeting the required ratios for bedrooms not served by individual adjoining toilet or bath-

rooms. 14 The clinic sink may be deleted if all bedrooms in the nursing unit are provided with adjoining toilets with bedpan flushing devices. 15 Conventional controls on hot-and cold-water supplies are acceptable. The water discharge points shall be 5 inches (127 millimeters) above the fixture rim. Aerators are not permitted. Non-aerating laminar flow devices are permitted. 16 Plumbing fixtures for public use shall be readily accessible and are to be based on 50% of the seating capacity value. Fixture quantity shall be based on Table 422.1 for an occupancy group A2. 17 In a multiple-bed room, every bed position shall be within 20 feet (6 meters) of a hands-free handwashing fixture. Where an individual room concept is used, a handwashing fixture shall be provided within each infant care room. 18 When three or more procedure rooms are provided. 19 If a separate medicine room is provided, the room shall be equipped with a sink in addition to the nurses' station handwashing fixture. Hot-water supplies are optional. 20 Where the patient room can only be accessed through the ante room the handwash fixture may be omitted in the patient room. 21 Handwashing fixtures may be deleted if room is used for storage and holding only. 22 If room is used only for temporary holding of soiled materials, clinic sink and work counter may be omitted. If the flushing-rim clinical sink is eliminated, facilities for cleaning bedpans shall be provided elsewhere. 23 Toilet shall be equipped with a bedpan flushing attachment. 24 Optional services approved by the licensing agency shall comply with the applicable space requirements of OSHPD 1 and 2. 25 Shall be provided in each separate room where open medication is handled. 26 Conveniently accessible throughout the unit. 27 Includes rooms or areas within coronary and intensive-care units and postanethesia recovery rooms. 28 Modular toilet/sink combination units located within a privacy curtain may be used within individual patient space or private room. The toilet fixture shall be completely contained within cabinetry when not in use, and shall be enclosed when flushed. Bedpan washers shall not be permitted in patient bedrooms. 29 In service spaces with procedure rooms that do not have dedicated patient toilets, provide a minimum of one patient toilet room with a separate handwash- ing fixture within the service space. 30 Toilet room shall be accessible from the procedure room. 31 Scrub sink shall be located outside the staff entrance to the procedure room. 32 Not used. 33 Handwashing and scrub sink fixtures shall not be equipped with wrist or elbow blades but shall be equipped with sensor controls, or controls that do not involve contact with the upper extremities. 34 If room is used only for temporary holding of soiled material, clinic sink and work counter may be omitted. 35 A minimum of one separate accessible toilet room shall be provided for the use of patients. Patient toilet room(s) shall be equipped with a handwashing fix- ture and shall be accessible to the observation units(s) from the corridor. Reference CBC, Part 2, Section 1224.39.6. 36 Handwashing stations are required in patient toilet rooms. Handwashing stations are not required in patient bedrooms. 37 Staff toilet facilities located in the surgical unit can be applied to the total fixture count.

t room(s) shall be equipped with a handwashing fix-_ ture and shall be accessible to the observation units(s) from the corridor. Reference CBC, Part 2, Section 1224.39.6. 36 Handwashing stations are required in patient toilet rooms. Handwashing stations are not required in patient bedrooms. 37 Staff toilet facilities located in the surgical unit can be applied to the total fixture count.

PLUMBING FIXTURES AND FIXTURE FITTINGS

TABLE 4-3 [AGR]

TYPE OF BUILDING
OR OCCUPANCY
WATER CLOSETS
7
(FIXTURES PER PERSON)
URINALS (TROUGH URINAL
TO INDIVIDUAL
URINAL EQUIVALENCE)
MALE
LAVATORIES
(FIXTURES
PER PERSON)
BATHTUBS OR SHOWERS
(FIXTURES PER PERSON)
DRINKING
FOUNTAINS
(FIXTURES
3
PER PERSON)
TYPE OF BUILDING
OR OCCUPANCY
MALE FEMALE MALE FEMALE MALE FEMALE MALE FEMALE MALE FEMALE
Nonindustrial—office
buildings, public build-
ings and similar estab-
lishments
1 1-15
1 1-15
2 16-35
2 16-35
3 36-55
3 36-55
4 56-80
4 56-80
5 81-110
5 81-110
6 111-150
6 111-150
1 additional for each
additional 40 employees
or fraction thereof
Length of
Number of
trough urinal
individual
urinals

24" (610 mm)
_1 _
36" (914 mm)
_2 _
48" (1219 mm)
_2 _
60" (1524 mm)
_3 _
1 1-15
2 16-35
3 36-60
4 61-90
5 91-125
1 additional for each
additional 4 employ-
ees or fraction thereof
1:10 persons per shift
required to shower
Industrial–factories,
warehouses, loft build-
ings and similar estab-
lishments
1 1-15
1 1-15
2 16-35
2 16-35
3 36-55
3 36-55
4 56-80
4 56-80
5 81-110
5 81-110
6 111-150
6 111-150
1 additional for each
additional 40 employees
or fraction thereof
24" (610 mm)
_1 _
36" (914 mm)
_2 _
48" (1219 mm)
_2 _
60" (1524 mm)
_3 _
72" (1829 mm)
4
1 to 100
employees
1 per 10

Over 100 employees 1
additional for each
additional 15 employ-
ees or fraction thereof
1:10 persons per shift
required to shower

Notes: 1 The figures shown are based on one fixture being the minimum required for the number of persons indicated or any fraction thereof. 2 Each water closet shall occupy a separate compartment which shall be equipped with a door, door latch and clothes hook. The door and the walls or partitions between fixtures shall be sufficient to assure privacy. 3 Drinking fountains shall not be located in toilet rooms. 4 Washing facilities shall be reasonably accessible to all employees. 5 Toilet facilities shall be accessible to the employees at all times. Where practicable, toilet facilities should be within 200 feet (61 m) of locations at which workers are reg- ularly employed and should not be more than one floor-to-floor flight of stairs from working areas. 6 Urinals may be installed instead of water closets in toilet rooms to be used only by men provided that the number of water closets shall not be less than two thirds of the minimum number of toilet facilities specified. The length of trough urinals to the equivalent number of individual urinals shall be based on the above table. 7 When there are less than five employees, separate toilet rooms for each sex are not required provided toilet rooms can be locked from the inside and contain at least one water closet. 8 Twenty-four linear inches of wash sink or 18 inches of circular basin, when provided with water outlets for such space, shall be considered equivalent to one lavatory. Exception: The requirements of Table 4-3 do not apply to mobile crews or to normally unattended work locations provided employees at these locations have immediately available transportation to nearby toilet facilities which meet the requirements of Table 4-3.

TABLE 4-4 [DPH]

TYPE OF BUILDING
OR OCCUPANCY2
WATER CLOSETS
(FIXTURES PER PERSON)
URINALS
(FIXTURES PER MALE)
LAVATORIES
(FIXTURES PER PERSON)
BATHTUBS OR SHOWERS
(FIXTURES PER PERSON)
DRINKING FOUNTAINS
(FIXTURES PER PERSON)
Day Use Public
Beaches1,2
Male
Female
1 1-100
1 1-100
No sex designated
1 1-500
Minimum of 2
May be substituted for
up to two-thirds of the
water closets required
Picnic Areas Male
Female
1 1-50
1 1-50
Overnight Use
Public Beaches2
_1 1-7.5 campsites3 _
1 1-7.5 campsites3
May be substituted for
up to one-third of the
water closets required3
1 1-12.5 campsites4
Organized Camps 1 1-153 1 1-15 1 1-156 Minimum 1 per camp

Notes: 1 Toilets shall be located in accordance with actual use patterns on the beach. The reasonable intent of the toilet requirements is that it should apply on the basis of aver- age daily use during periods of peak use. The health officer may determine how many days the population standard may be exceeded. 2 Laundry facilities are not required, but if they are provided, must be a minimum of two laundry trays or a washing machine. 3 Toilet facilities shall not be farther than 400 feet from any lot or campsite. 4 Showers are not required, but it provided, they shall be provided on the indicated ratio. Outdoor rinse-off showers may be cold water only. 5 Toilets shall be located within 300 feet from the living accommodations they serve. 6 Showers shall be provided in the living area or in a centrally located structure. Exception: Intermittent short-term organized camps are not required to provide shower facilities, but it provided, they shall comply with this part.

80 2025 CALIFORNIA PLUMBING CODE

CALIFORNIA PLUMBING CODE – MATRIX ADOPTION TABLE

Get a plain-English answer with a citation back to this text.

Ask AI about this code
Contents — California Plumbing Code (Title 24, Part 5)
California Plumbing Code (Title 24, Part 5)
  1. Chapter 1 — GENERAL CODE PROVISIONS
  2. Chapter 2 — DEFINITIONS
  3. Chapter 3 — GENERAL REGULATIONS
  4. Chapter 4 — PLUMBING FIXTURES AND FIXTURE FITTINGS
    Overview
    1. 401.1 Applicability. This chapter shall govern the materials
    2. 401.2 Quality of Fixtures. Plumbing fixtures shall be construc…
    3. 401.3 Water-Conserving Fixtures and Fittings.
    4. 402.1 Cleaning. Plumbing fixtures shall be installed in a
    5. 402.2 Joints. Where a fixture comes in contact with the wall
    6. 402.3 Securing Fixtures. Floor-outlet or floor-mounted
    7. 402.4 Wall-Hung Fixtures. Wall-hung fixtures shall be
    8. 402.5 Setting. Fixtures shall be set level and in proper align…
    9. 402.6 Flanged Fixture Connections. Fixture connections between…
    10. 402.7 Supply Fittings. The supply lines and fittings for
    11. 402.8 Installation. Fixtures shall be installed in accordance
    12. 402.9 Design and Installation of Plumbing Fixtures.
    13. 402.10 Slip Joint Connections. Fixtures having concealed slip …
    14. 402.11 Future Fixtures. Where provisions are made for the
    15. 403.1 General. Where accessible facilities are required in
    16. 403.2 Fixtures and Fixture Fittings for Persons with
    17. 403.3 Exposed Pipes and Surfaces. Water supply and
    18. 404.1 Waste Fittings. Waste fittings shall comply with
    19. 404.2 Overflows. Where a fixture is provided with an overflow,…
    20. 405.1 Prohibited Water Closets. Water closets having an
    21. 405.2 Prohibited Urinals. Trough urinals and urinals with
    22. 405.3 Miscellaneous Fixtures. Fixed wooden, or tile wash
    23. 406.1 Water and Waste Connections. Baptisteries, ornamental an…
    24. 406.2 Special Use Sinks. Restaurant kitchen and other
    25. 406.3 Special Use Fixtures. Special use fixtures shall be
    26. 406.4 Zinc Alloy Components. Zinc alloy components
    27. 407.1 Application. Lavatories shall comply with ASME
    28. 407.2 Water Consumption. The maximum water flow rate
    29. 407.3 Limitation of Hot Water Temperature for Public
    30. 407.4 Transient Public Lavatories. Self-closing or metering fa…
    31. 407.5 Waste Outlet. Lavatories shall have a waste outlet
    32. 407.6 Overflow. Where overflows are provided, they shall
    33. 408.1 Application. Manufactured shower receptors and
    34. 408.2 Tileable Shower Receptors. Tileable shower receptors and…
    35. 408.3 Water Consumption. Showerheads shall have a «
    36. 408.6 Finished Curb or Threshold. Where a shower
    37. 408.7 Shower Compartments. Shower compartments
    38. 408.8 Lining for Showers and Receptors. Shower
    39. 408.4 Individual Shower and Tub-Shower Combina-
    40. 408.5 Waste Outlet. Showers shall have a waste outlet and
    41. 408.9 Public Shower Floors. Floors of public shower
    42. 408.10 Location of Valves and Heads. Control valves
    43. 408.11 Water Supply Riser. A water supply riser from the
    44. 409.1 Application. Bathtubs shall comply with ASME
    45. 409.2 Waste Outlet. Bathtubs and whirlpool bathtubs shall
    46. 409.3 Overflow. Where overflows are provided, they shall
    47. 409.4 Limitation of Hot Water Temperature in Bath-
    48. 411.3 Water Closet Seats. Water closet seats shall be properly…
    49. 411.4 Personal Hygiene Devices. Water closets with
    50. 412.1 Application. Urinals shall comply with ASME
    51. 409.5 Backflow Protection. The water supply to a bathtub
    52. 409.6 Installation and Access. Bathtubs and whirlpool
    53. 410.1 Application. Bidets shall comply with ASME
    54. 410.2 Backflow Protection. The water supply to the bidet
    55. 410.3 Limitation of Water Temperature in Bidets. The
    56. 411.1 Application. Water closets shall comply with ASME
    57. 411.2 Water Consumption. The effective flush volume of
    58. 412.2 Backflow Protection. A water supply to a urinal
    59. 413.1 Where Required. Each water closet, urinal, clinical
    60. 413.2 Flushometer Valves. Flushometer valves and
    61. 413.3 Flush Tanks. Flush tanks for manual flushing shall
    62. 413.4 Water Supply for Flush Tanks. An adequate quantity of wa…
    63. 413.5 Overflows in Flush Tanks. Flush tanks shall be provided …
    64. 414.1 Application. Domestic dishwashing machines shall
    65. 414.2 Backflow Protection. The water supply connection
    66. 414.3 Drainage Connection. Domestic dishwashing
    67. 414.4 Lead Content. Dishwashing machines shall comply
    68. 415.1 Application. Drinking fountains shall be self-closing
    69. 415.2 Drinking Fountain Alternatives. Where food is
    70. 415.3 Drainage Connection. Drinking fountains shall be
    71. 415.4 Location. Drinking fountains shall not be installed in
    72. 416.1 Application. Emergency eyewash and shower equipment shal…
    73. 416.2 Water Supply. Emergency eyewash and shower
    74. 416.3 Installation. Emergency eyewash and shower equipment sha…
    75. 416.4 Location. Emergency eyewash and shower equipment shall b…
    76. 416.5 Drain. A drain shall not be required for emergency
    77. 417.1 Application. Faucets and fixture fittings shall comply
    78. 417.2 Deck Mounted Bath/Shower Valves. Deck
    79. 417.3 Handheld Showers. Handheld showers shall comply
    80. 417.4 Faucets and Fixture Fittings with Hose Con-
    81. 417.5 Separate Controls for Hot and Cold Water.
    82. 417.6 Low-Pressure Water Dispenser. Beverage faucets
    83. 417.7 Head Shampoo Sink Faucets. Head shampoo sink
    84. 417.8 Footbaths and Pedicure Baths. The water supplied to spec…
    85. 418.1 Application. Floor drains shall comply with ASME
    86. 418.2 Strainer. Floor drains shall be considered plumbing
    87. 418.3 Location of Floor Drains. Floor drains shall be
    88. 418.4 Food Storage Areas. Where drains are provided in
    89. 418.5 Floor Slope. Floors shall be sloped to floor drains.
    90. 419.1 Application. Food waste disposal units shall comply
    91. 419.2 Drainage Connection. Approved wye or other
    92. 419.3 Water Supply. A cold water supply shall be provided
    93. 420.1 Application. Sinks shall comply with ASME
    94. 420.2 Water Consumption. Sink faucets shall have a maximum flo…
    95. 420.3 Pre-Rinse Spray Valve. Commercial food service
    96. 420.4 Waste Outlet. Kitchen and laundry sinks shall have
    97. 421.1 Application. Floor sinks shall comply with ASME
    98. 421.2 Strainers. The waste outlet of a floor sink shall be
    99. 422.1 Fixture Count. Plumbing fixtures shall be provided
    100. 422.3 Fixture Requirements for Special Occupancies.
    101. 422.4 Toilet Facilities Serving Employees and Cus-
    102. 422.2 Separate Facilities. Separate toilet facilities shall
    103. 422.5 Toilet Facilities for Workers. Toilet facilities shall
    104. 422.6 Water Closet Compartment. Public water closets
    105. 422.7 Urinal Partitions. Each urinal shall be separated with
    106. 422.8 Cosmetology. [CA] Each school shall provide pub-
    107. 422.9 Cosmetology Establishments. [CA] Each estab-
    108. 422.10 Commissaries Serving Mobile Food Prepara-
    109. 422.11 Employee Lavatories in Food Establishments.
  5. Chapter 5 — WATER HEATERS
  6. Chapter 6 — WATER SUPPLY AND DISTRIBUTION
  7. Chapter 7 — SANITARY DRAINAGE
  8. Chapter 8 — INDIRECT WASTES
  9. Chapter 9 — VENTS
  10. Chapter 10 — TRAPS AND INTERCEPTORS
  11. Chapter 11 — STORM DRAINAGE
  12. Chapter 12 — FUEL GAS PIPING
  13. Chapter 13 — HEALTH CARE FACILITIES AND MEDICAL GAS AND MEDICA…
  14. Chapter 14 — FIRESTOP PROTECTION
  15. Chapter 15 — ALTERNATE WATER SOURCES FOR NONPOTABLE APPLICATIONS
  16. Chapter 16 — NONPOTABLE RAINWATER CATCHMENT SYSTEMS
  17. Chapter 17 — REFERENCED STANDARDS
  18. Appendix A — RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYS…
  19. Appendix B — EXPLANATORY NOTES ON COMBINATION WASTE AND VENT S…
  20. Appendix C — ALTERNATE PLUMBING SYSTEMS
  21. Appendix D — SIZING STORM WATER DRAINAGE SYSTEMS
  22. Appendix E — MANUFACTURED/MOBILE HOME PARKS AND RECREATIONAL V…
  23. Appendix F — FIREFIGHTER BREATHING AIR REPLENISHMENT SYSTEMS
  24. Appendix G — SIZING OF VENTING SYSTEMS
  25. Appendix H — PRIVATE SEWAGE DISPOSAL SYSTEMS
  26. Appendix I — INSTALLATION STANDARDS
  27. Appendix J — COMBINATION OF INDOOR AND OUTDOOR COMBUSTION AND …
  28. Appendix K — POTABLE RAINWATER CATCHMENT SYSTEMS
  29. Appendix L — SUSTAINABLE PRACTICES
  30. Appendix M — PEAK WATER DEMAND CALCULATOR
  31. Appendix N — IMPACT OF WATER TEMPERATURE ON THE POTENTIAL FOR …