Skip to content

Appendix O — NON-SEWERED SANITATION SYSTEMS

2025 California Plumbing Code (Title 24, Part 5) · 2025 edition · updated 2026-07-27 · California

Italicized text is a California amendment to the model code, as printed in the official publication.

(Matrix Adoption Tables are non-regulatory, intended only as an aid to the code user. See Chapter 1 for state agency authority and building applications.)

Adopting Agency BSC BSC-
CG
SFM HCD DSA OSHPD BSCC DPH AGR DWR CEC CA SL SLC
Adopting Agency BSC BSC-
CG
SFM 1 2 1-AC AC ** SS** SS/CC 1 1R 2 3 4 5 6 6 6 6 6 6 6 6 6
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section

This state agency does not adopt sections identified with the following symbol: The Office of the State Fire Marshal’s adoption of this chapter or individual sections is applicable to structures regulated by other state agencies pursuant to Section 1.11.0.

), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.

532 2025 CALIFORNIA PLUMBING CODE

), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.

APPENDIX O

NON-SEWERED SANITATION SYSTEMS

The provisions contained in this appendix are not mandatory unless specifically adopted by a state agency, or referenced in the adopting ordinance.

O 101.0 General.

O 101.1 Applicability. The provisions of this appendix shall apply to the installation of non-sewered sanitation systems. O 101.2 System Requirements. Non-sewered sanitation systems shall comply with ANSI/CAN/IAPMO/ISO 30500.

O 201.0 Definitions.

O 201.1 General. For the purpose of this appendix, the following definitions shall apply: Conditioned Space. An area, room, or space normally occupied and being heated or cooled for human habitation by any equipment. Non-Sewered Sanitation System . A prefabricated integrated sewage treatment unit that is not connected to a public sewer or private sewage disposal system.

O 301.0 Installation.

O 301.1 General. The installation of non-sewered sanitation systems shall be in accordance with the manufacturer’s installation instructions and with Section O 301.2 through Section O 301.7.

O 301.2. Operating Conditions. A non-sewered sanitation system in either a conditioned or unconditioned space shall be installed where the ambient temperature, ambient humidity, and altitude (atmospheric pressure) are in accordance with the manufacturer’s installation instructions or product listing. O 301.3 Clearances for Servicing and Maintenance. A non-sewered sanitation system shall be located to permit access and sufficient clearance for service and maintenance. Unless otherwise specified by the manufacturer’s installation instructions, not less than 30 inches (762 mm) in depth, width, and height of working space shall be provided at any access panel. O 301.4 Backflow Prevention. A domestic water supply connection to a non-sewered sanitation system shall be protected in accordance with this code.

O 301.5 Effluent Storage. Any container or vessel for the storage of effluent discharged from a non-sewered sanitation system and not integral to such system shall be installed in accordance with the plumbing code. O 301.6 Systems Employing Combustion. A non-sewered sanitation system employing combustion shall comply with the mechanical code.

O 301.7 Connection to Plumbing System Not Required. Unless the Authority Having Jurisdiction determines otherwise, a non-sewered sanitation system is not required to be connected to the drainage system of the building or premises.

O 401.0 Manual Required. O 401.1 Operation and Maintenance Manual. Nonsewered sanitation systems shall have an operation and maintenance manual provided by the manufacturer.

O 501.0 System Output. O 501.1 General. The use or disposal of all substances exiting the non-sewered sanitation system shall be determined by the Authority Having Jurisdiction.

), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.

534 2025 CALIFORNIA PLUMBING CODE

), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.

CALIFORNIA PLUMBING CODE – MATRIX ADOPTION TABLE

Get a plain-English answer with a citation back to this text.

Ask AI about this code
Contents — 2025 California Plumbing Code (Title 24, Part 5)
2025 California Plumbing Code (Title 24, Part 5)
  1. Chapter 1 — GENERAL CODE PROVISIONS
  2. Chapter 2 — DEFINITIONS
  3. Chapter 3 — GENERAL REGULATIONS
  4. Chapter 4 — PLUMBING FIXTURES AND FIXTURE FITTINGS
  5. Chapter 5 — WATER HEATERS
  6. Chapter 6 — WATER SUPPLY AND DISTRIBUTION
  7. Chapter 7 — SANITARY DRAINAGE
  8. Chapter 8 — INDIRECT WASTES
  9. Chapter 9 — VENTS
  10. Chapter 10 — TRAPS AND INTERCEPTORS
  11. Chapter 11 — STORM DRAINAGE
  12. Chapter 12 — FUEL GAS PIPING
  13. Chapter 13 — HEALTH CARE FACILITIES AND MEDICAL GAS AND MEDICA…
  14. Chapter 14 — FIRESTOP PROTECTION
  15. Chapter 15 — ALTERNATE WATER SOURCES FOR NONPOTABLE APPLICATIONS
  16. Chapter 16 — NONPOTABLE RAINWATER CATCHMENT SYSTEMS
  17. Chapter 17 — REFERENCED STANDARDS
  18. Appendix A — RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYS…
  19. Appendix B — EXPLANATORY NOTES ON COMBINATION WASTE AND VENT S…
  20. Appendix C — ALTERNATE PLUMBING SYSTEMS
  21. Appendix D — SIZING STORM WATER DRAINAGE SYSTEMS
  22. Appendix E — MANUFACTURED/MOBILE HOME PARKS AND RECREATIONAL V…
  23. Appendix F — FIREFIGHTER BREATHING AIR REPLENISHMENT SYSTEMS
  24. Appendix G — SIZING OF VENTING SYSTEMS
  25. Appendix H — PRIVATE SEWAGE DISPOSAL SYSTEMS
  26. Appendix I — INSTALLATION STANDARDS
  27. Appendix J — COMBINATION OF INDOOR AND OUTDOOR COMBUSTION AND …
  28. Appendix K — POTABLE RAINWATER CATCHMENT SYSTEMS
  29. Appendix L — SUSTAINABLE PRACTICES
  30. Appendix M — PEAK WATER DEMAND CALCULATOR
  31. Appendix N — IMPACT OF WATER TEMPERATURE ON THE POTENTIAL FOR …
  32. Appendix O — NON-SEWERED SANITATION SYSTEMS
  33. Appendix P — PROFESSIONAL QUALIFICATIONS
  34. Appendix Q — INDOOR HORTICULTURAL FACILITIES
  35. Appendix R — TINY HOUSES
  36. Appendix S — ONSITE STORMWATER TREATMENT SYSTEMS

GoCodebook provides public access, search, citation, multilingual explanation, and practical interpretation of legally adopted building regulations. It is not a substitute for the official ICC or California code publications.