Commercial food service pre-rinse spray valves shall have a maximum flow rate in accordance with Table 420.3 and shall be equipped with an integral automatic shutoff.

TABLE 420.3

COMMERCIAL PRE-RINSE SPRAY VALVE MAXIMUM FLOW RATE

PRODUCT CLASS BY SPRAY FORCE MAXIMUM FLOW RATE,
GPM

Product Class 1 (≤ 5.0 ounces-force)
1.00


Product Class 2 (> 5.0 ounces-force and
≤ 8.0 ounces-force)
1.20

Product Class 3 (> 8.0 ounces-force)
1.28

For SI units: 1 gallon per minute = 3.785 L/min, 1 ounce-force = 0.278 N