Urinals shall comply with ASME A112.19.2/CSA B45.1, ASME A112.19.19, or CSA B45.5/IAPMO Z124. Wall-mounted urinals shall have an average water consumption not to exceed 0.125 gallons (0.47 L) per flush. Other urinals shall have an average water con- sumption not to exceed 0.5 gallons (1.89 L) per flush.
412.1.1 Wall-Mounted Urinals. [BSC-CG & DSA- SS] The effective flush volume of wall-mounted urinals shall not exceed 0.125 gallons (0.47 L) per flush in com- pliance with Chapter 5, Division 5.3, of the California Green Building Standards Code (CALGreen).
412.1.2 Floor-Mounted Urinals. [BSC-CG & DSA- SS] The effective flush volume of floor-mounted or other urinals shall not exceed 0.5 gallons (1.89 L) per flush in compliance with Chapter 5, Division 5.3, of the California Green Building Standards Code (CALGreen).
»
(1) A limiting device conforming to either ASSE 1070/ASME A112.1070/CSA B125.70 or CSA B125.3.
(2) A water heater conforming to ASSE 1084.