CALGreen · California Green Building Standards Code (CALGreen)
Chapter 6 — How to use the referenced standards list
Chapter 6 cross‑references the external standards CALGreen relies on, shows where each standard is cited, and explains that standards apply only where the code references them.
Last reviewed: July 6, 2026
Overview
Chapter 6 is the CALGreen “Referenced Organizations and Standards” chapter: it collects the external standards and issuing agencies that the code cites and identifies where each standard applies in the code (see §601) . Use this chapter as the cross‑reference between CALGreen requirements and the normative technical documents (ASTM, ANSI, NFPA, etc.) that supply test methods, material specs, and product performance criteria relied on by CALGreen provisions.
This matters because a referenced standard becomes part of the enforceable requirement only to the extent it is cited by a CALGreen section; CALGreen and related California codes consistently state that referenced standards apply “to the extent of the reference” (see the explanation in the residential referenced‑standards chapter and similar referenced‑standards tables) . Many CALGreen provisions point users to those standards (for example §5.303.6 on plumbing fixtures and installation references Chapter 6 standards, and commissioning requirements in §5.410.2 are supported by the commissioning referenced standards and forms in Chapter 8) .
When you consult Chapter 6, look first for the standard identifier and the sections that reference it; the code and its companion tables are organized so each listed standard shows the promulgating agency, standard number, effective date/title and the CALGreen sections that refer to it — which lets you confirm exactly which version and which parts are enforceable for your project .
In this section
Code references
Grounded in the retrieved California Green Building Standards Code (CALGreen) — click a citation to read the verbatim passage:
CALGreen § 405.4 High relevance — show source text
- From Division A5.4,
a. Comply with recycled content of 10 percent of materials based on estimated total cost, or use two products from Table A5.405.4 for at least 75 percent by cost in Section A5.405.4. b. Comply with the 65-percent reduction in construction and demolition waste in Section A5.408.3.1. c. Comply with one elective measure selected from this division.
- From Division A5.5,
a. Comply with resilient flooring systems for 90 percent of resilient flooring in Section A5.504.4.7. b. Comply with thermal insulation meeting 2009 CHPS low-emitting materials list in Section A5.504.4.8. c. Comply with one elective measure selected from this division. 6. Comply with one additional elective measure selected from any division.
1 Cool roof is required for compliance with Tiers 1 and 2 and may be used to meet energy standards in Part 6, exceed energy standards and to mitigate heat island effect.
A5.601.3 CALGreen Tier 2.
A5.601.3.1 Prerequisites. To achieve CALGreen tier status, a project must meet all of the mandatory measures in Chapter 5 and, in addition, meet the provisions of this section.
A5.601.3.2 Energy performance. For the purposes of mandatory energy efficiency standards in this code, the California Energy Commission will continue to adopt mandatory standards.
A5.601.3.3 Tier 2. Comply with the energy efficiency requirements in Section A5.203.1.1 and Section A5.203.1.2.2.
A5.601.3.4 Voluntary measures for Tier 2. In addition to the provisions of Sections A5.601.3.1 and A5.601.3.3 above, compliance with the following voluntary measures from Appendix A5 is required for Tier 2:
- From Division A5.1, a. Comply with the designated parking requirements for fuel efficient vehicles for a minimum of 50 percent of parking capacity per Section A5.106.5.1. b. Electric vehicle (EV) charging [N] and Table A5.106.5.3.2 with footnotes. c. Comply with thermal emittance, solar reflectance or SRI values for cool roofs in Section A5.106.11.2 and Table A5.106.11.2.3. [1]
d. Comply with three elective measures selected from this division.
APPENDIX A5-42 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
APPENDIX A5 — NONRESIDENTIAL VOLUNTARY MEASURES
From Division A5.2 comply with TWO of the following:
Outdoor lighting as described in A5.203.1.1.1.
Service water heating in restaurants as described in A5.203.1.1.2.
Warehouse Dock Seal Doors A5.203.1.1.3.
Daylight Design Power Adjustments 5.203.1.1.4.
Exhaust Air Heat Recovery A5.203.1.1.5.
From Division A5.3,
CALGreen § 5.1 Medium relevance — show source text
5.1 Planning and Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-3 5.2 Energy Efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-15 5.3 Water Efficiency and Conservation . . . . . . . . . . . . . . . 5-19 5.4 Material Conservation and Resource Efficiency . . . . 5-23 5.5 Environmental Quality . . . . . . . . . . . . . . . . . . . . . . . . . . 5-31
CHAPTER 6 REFERENCED ORGANIZATIONS
AND STANDARDS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3
601 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-3
CHAPTER 7 INSTALLER AND SPECIAL
INSPECTOR QUALIFICATIONS . . . . . . . . . . . . . . . . . . . . . . 7-3 701 General (Reserved) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-3 702 Qualifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-3
703 Verifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-3
CHAPTER 8 COMPLIANCE FORMS, WORKSHEETS AND
REFERENCE MATERIAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-3
Worksheet (WS-1) Baseline Water Use: Baseline Water Use Calculation Table . . . . . . . . . . .8-3
Worksheet (WS-2) Water Use Reduction: 12-, 20- or 25-Percent Reduction Water Use Calculation Table . . . . . . . . . . . . . . . . . . .8-4
Worksheet (WS-3) 5.105.2 Building Reuse . . . . . . . . . . . . . . . .8-4 Worksheet (WS-4) 5.409.2 Whole Building Life Cycle Assessment:. . . . . . . . . . . . . . . . . . . . . . . . .8-5 Worksheet (WS-5) 5.409.3 Product GWP Compliance—Prescriptive Path: . . . . . . . . . . . . . . . .8-5
Worksheet (WS-6) A5.105.2 Building Reuse Tier 1 and Tier 2:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-5
Worksheet (WS-7) A5.409.2 Whole Building Life Cycle Assessment: . . . . . . . . . . . . . .
CALGreen § 8-10 Medium relevance — show source text
8-10 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
COMPLIANCE FORMS, WORKSHEETS AND REFERENCE MATERIAL
Title 23, Waters, California Code of Regulations
2025 CALIFORNIA GREEN BUILDING STANDARDS CODE 8-11
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
8-12 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
COMPLIANCE FORMS, WORKSHEETS AND REFERENCE MATERIAL
Commissioning Referenced Standards for Non-Energy Systems
The following CALGreen Referenced Standards are included herein as a convenience for the users of the California Green Building Standards Code, but they are not considered to be part of the code unless they are officially adopted by a local jurisdiction.
Contents Page Part 1: Standards for Compliance with Building Commissioning 8-14 Part 2: Commissioning Sample Forms and Templates 8-23
2025 CALIFORNIA GREEN BUILDING STANDARDS CODE 8-13
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
COMPLIANCE FORMS, WORKSHEETS AND REFERENCE MATERIAL
PART 1 STANDARDS FOR COMPLIANCE WITH BUILDING COMMISSIONING
Reference: Section 5.410.2, Commissioning.
Introduction:
The purpose of this code is to improve public health, safety and general welfare by enhancing the design and construction of buildings through the use of concepts that reduce negative and increase positive environmental impacts. Commissioning is a vital element in this effort.
Definitions used in the CALGreen Cx Reference standard:
Acronyms
BOD Basis of Design
Cx Commissioning
FPT Functional Performance Test
HVAC Heating, Ventilating and Air-Conditioning
O&M Operations and Maintenance
OPR Owner’s Project Requirements
Glossary:
Acceptance Criteria— The conditions that must be met for systems or equipment to meet defined and expected outcomes.
Commissioning (Cx)— Building commissioning as required in this code involves a quality assurance process that begins during design and continues to occupancy. Commissioning verifies that the new building operates as the owner intended and that building staff are prepared to operate and maintain its systems and equipment. Exceptions are allowed for dry storage warehouses of any size and conditioned spaces under 10,000 square feet accessory to them; and for tenant improvements under 10,000 square feet within a larger space.
Owner— The individual or entity holding title to the property on which the building is constructed.
Commissioning Coordinator— The person who coordinates the commissioning process. This can be either a third-party commissioning provider or an experienced member of the design team or owner in-house staff member.
Commissioning Team— The key members of each party involved with the project designated to provide insight and carry out tasks necessary for a successful commissioning project. Team members may include the commissioning coordinator, owner or owner’s representative, building staff, design professionals, contractors or manufacturer’s representatives and testing specialists.
CALGreen § 5.303.5 Medium relevance — show source text
Note: This code section does not affect local jurisdiction authority to prohibit or require disposer installation.
5.303.5 Areas of addition or alteration. For those occupancies within the authority of the California Building Standards Commission as specified in Section 103, the provisions of Sections 5.303.3 and 5.303.4 shall apply to new fixtures in additions or areas of alteration to the building.
5.303.6 Standards for plumbing fixtures and fittings. Plumbing fixtures and fittings shall be installed in accordance with the Cali- fornia Plumbing Code, and shall meet the applicable standards referenced in Table 1701.1 of the California Plumbing Code and in Chapter 6 of this code.
SECTION 5.304—OUTDOOR WATER USE
5.304.1 Outdoor potable water use in landscape areas. Nonresidential developments shall comply with a local water efficient landscape ordinance or the current California Department of Water Resources’ Model Water Efficient Landscape Ordinance (MWELO), whichever is more stringent.
Notes:
The Model Water Efficient Landscape Ordinance (MWELO) is located in the California Code of Regulations, Title 23, Chapter 2.7, Division 2.
MWELO and supporting documents, including a water budget calculator, are available at: https://www.water.ca.gov/.
5.304.2 Reserved.
5.304.3 Reserved.
5.304.4 Reserved.
5.304.5 Reserved.
5.304.6 Outdoor potable water use in landscape areas. For public schools and community colleges, landscape projects as described in Sections 5.304.6.1 and 5.304.6.2 shall comply with the California Department of Water Resources Model Water Efficient Landscape Ordinance (MWELO) commencing with Section 490 of Chapter 2.7, Division 2, Title 23, California Code of Regulations, except that the evapotranspiration adjustment factor (ETAF) shall be 0.65 with an additional water allowance for special landscape areas (SLA) of 0.35.
Exception: Any project with an aggregate landscape area of 2,500 square feet or less may comply with the prescriptive measures contained in Appendix D of the MWELO.
5.304.6.1 Newly constructed landscapes. New construction projects with an aggregate landscape area equal to or greater than 500 square feet.
5.304.6.2 Rehabilitated landscapes. Rehabilitated landscape projects with an aggregate landscape area equal to or greater than 1,200 square feet.
SECTION 5.305—WATER REUSE SYSTEMS (RESERVED)
5-20 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
CALIFORNIA GREEN BUILDING STANDARDS CODE – MATRIX ADOPTION TABLE
CHAPTER 5 – NONRESIDENTIAL MANDATORY MEASURES
DIVISION 5.4 – MATERIAL CONSERVATION AND RESOURCE EFFICIENCY
(Matrix Adoption Tables are nonregulatory, intended only as an aid to the code user. See Chapter 1 for state agency authority and building applications.)
CALGreen § 15-11 Medium relevance — show source text
are listed below||||||||X||||||||||||||| |Chapter/Section||||||||||||||||||||||| |WS-3||||||||X||||||||||||||| |WS-4||||||||X||||||||||||||| |WS-5||||||||X||||||||||||||| |WS-9||||||||X||||||||||||||| |IES TM-15-11 Table A-1||||||||X||||||||||||||| |Table 130.2-A||||||||X||||||||||||||| |Table 1302.2-B||||||||X|||||||||||||||
2025 CALIFORNIA GREEN BUILDING STANDARDS CODE 8-1
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
8-2 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
8 COMPLIANCE FORMS, WORKSHEETS AND REFERENCE MATERIAL
[BSC] Sample forms found in “A Guide to the California Green Building Standards Code (Nonresidential)” located at https://www.dgs.ca.gov/BSC/Resources/Page-Content/Building-Standards-Commission-Resources-List-Folder/CALGreen may be used to assist in documenting compliance with the waste management plan and other provisions of this code.
[HCD 1] Sample forms located at www.hcd.ca.gov/building-standards/calgreen/cal-green-forms.shtml may be used to assist in documenting compliance with CALGreen . WORKSHEET (WS-1) BASELINE WATER USE
BASELINE WATER USE CALCULATION TABLE Col2 Col3 Col4 Col5 Col6 Col7 Col8 Col9 Col10 FIXTURE TYPE FLOW RATE DURATION DAILY USES OCCUPANTS1 GALLONS PER DAY Showerheads 1.8 gpm @ 80 psi × 5 min. × 1 × Note 1a = Lavatory faucets nonresidential 0.5 gpm @ 60 psi × .25 min. × 3 × = Kitchen faucets 1.8 gpm @ 60 psi × 4 min. × 1 × Note 1b = Replacement aerators 2.2 gpm × × × = Wash fountains 1.8 gpm/20 [rim
space(in.)@ 60 psi]× × × = Metering faucets 0.20 gal/cycle × × 3 × = Metering faucets for wash
fountains0.20 gal/cycle/20 [rim
space(in.CALGreen § 1974-17 Medium relevance — show source text
E108-2020a|||X||||||||||||||||||||| |CSA||||X|||||||||||||||||||| |DASMA||||X|||||||||||||||||||| |ICC|||X|X|||||||||||||||||||| |IFC-18||||X|||||||||||||||||||| |ISO||||X|||||||||||||||||||| |NFPA|||X|X|||||||||||||||||||| |NFPA 68-13|||X||||||||||||||||||||| |SFM|||X||||||||||||||||||||| |UBC|||X||||||||||||||||||||| |UL||||X|||||||||||||||||||| |UL 790 Edition 9 2022|||X||||||||||||||||||||| |UL 1974-17|||X||||||||||||||||||||| |UL 9540-20|||X||||||||||||||||||||| |UL 9540 Edition 4 2019|||X||||||||||||||||||||| |WDMA||||X||||||||||||||||||||
The state agency does not adopt sections identified with the following symbol: †
2025 CALIFORNIA RESIDENTIAL CODE 44-1
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
44-2 2025 CALIFORNIA RESIDENTIAL CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
Part IX— Referenced Standards
44 REFERENCED STANDARDS
Notwithstanding California laws and regulations, these referenced standards shall be applicable only to those California Residential Code sections that are adopted.
User notes:
About this chapter: The one- and two-family dwelling code contains numerous references to standards promulgated by other organizations that are used to provide requirements for materials, products and methods of construction. Chapter 44 contains a comprehensive list of all standards that are referenced in this code. These standards, in essence, are part of this code to the extent of the reference to the standard.
This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section R102.4.
ABTG Applied Building Technology Group LLC6300 Enterprise Lane Madison, WI 53719
ANSI/ABTG FS 100—2012 (R2018): Standard Requirements for Wind Pressure Resistance of Foam Plastic Insulation Sheathing Used in Exterior Wall Covering Assemblies
R303.8
ACCA Air Conditioning Contractors of America 1330 Braddock Place, Suite 350 Alexandria, VA 22314
ANSI/ACCA 2 Manual J—2016: Residential Load Calculation
Table R301.2
ACI American Concrete Institute 38800 Country Club Drive Farmington Hills, MI 48331
CALGreen § 602.1 Medium relevance — show source text
VOLUNTARY MEASURES. . . . . . . . . . . . . . . . . APPENDIX A5-3
A5.1 Planning and Design . . . . . . . . . . . . . . . . . APPENDIX A5-3 A5.2 Energy Efficiency . . . . . . . . . . . . . . . . . . . APPENDIX A5-13 A5.3 Water Efficiency and Conservation . . . APPENDIX A5-19 A5.4 Material Conservation and Resource Efficiency . . . . . . . . . . . . . . . . . . . . . . . . APPENDIX A5-25 A5.5 Environmental Quality . . . . . . . . . . . . . . APPENDIX A5-35 A5.6 Voluntary Tiers . . . . . . . . . . . . . . . . . . . . . APPENDIX A5-41 A5.601 CALGren Tier 1 and Tier 2. . . . . . . . . . APPENDIX A5-41
A5.602 CALGreen Verification Guidelines Mandatory Measures Checklist . . . . . . . . . . . . . . . APPENDIX A5-44
A5.602.1 CALGreen Verification Guidelines
Tier 1 Checklist . . . . . . . . . . . . . . . . . APPENDIX A5-48
A5.602.2 CALGreen Verification Guidelines
Tier 2 Checklist . . . . . . . . . . . . . . . . . APPENDIX A5-55
APPENDIX A6 VOLUNTARY STANDARDS FOR HEALTH
FACILITIES [OSHPD 1, 2 & 4] . . . . . . . . . . . APPENDIX A6.1-3 A6.1 Site Planning and Design . . . . . . . . . . . APPENDIX A6.1-3 A6.2 Energy Efficiency . . . . . . . . . . . . . . . . . . APPENDIX A6.1-3 A6.4 Material Conservation and Resource Efficiency . . . . . . . . . . . . . APPENDIX A6.1-32 A6.5 Environmental Quality . . . . . . . . . . . . APPENDIX A6.1-33
INDEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INDEX-1
HISTORY NOTE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HIST-1
2025 CALIFORNIA GREEN BUILDING STANDARDS CODE vii
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
viii 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
CALIFORNIA GREEN BUILDING STANDARDS CODE – MATRIX ADOPTION TABLE
CHAPTER 1 – ADMINISTRATION
(Matrix Adoption Tables are nonregulatory, intended only as an aid to the code user. See Chapter 1 for state agency authority and building applications.)
|Adopting
CALGreen § 3-4 Medium relevance — show source text
302 Mixed Occupancy Buildings . . . . . . . . . . . . . . . . . . . . . . .3-4 303 Phased Projects. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4 304 Voluntary Tiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4 305 CALGreen Tier 1 and CALGreen Tier 2 . . . . . . . . . . . . . .3-4
306 Voluntary Measures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4
CHAPTER 4 RESIDENTIAL MANDATORY MEASURES . . . . . . 4-3
4.1 Planning and Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-3 4.2 Energy Efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-7 4.3 Water Efficiency and Conservation . . . . . . . . . . . . . . . . .4-9 4.4 Material Conservation and Resource Efficiency . . . . 4-11 4.5 Environmental Quality . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13
CHAPTER 5 NONRESIDENTIAL MANDATORY MEASURES . . 5-3
5.1 Planning and Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-3 5.2 Energy Efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-15 5.3 Water Efficiency and Conservation . . . . . . . . . . . . . . . 5-19 5.4 Material Conservation and Resource Efficiency . . . . 5-23 5.5 Environmental Quality . . . . . . . . . . . . . . . . . . . . . . . . . . 5-31
CHAPTER 6 REFERENCED ORGANIZATIONS
AND STANDARDS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3
601 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-3
CHAPTER 7 INSTALLER AND SPECIAL
INSPECTOR QUALIFICATIONS . . . . . . . . . . . . . . . . . . . . . . 7-3 701 General (Reserved) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-3 702 Qualifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-3
CALGreen § 1616.2.2.1 Medium relevance — show source text
Demolition 3303 Design Flood 1612 Design Strength Column splice 1616.2.2.1 Conformance to standards 1706.1
New materials 1706.2 Designated Seismic System 1704.3.2, 1704.4, 1704.5 Seismic certification 1705.14.3
Special inspection 1705.13.4 Detached Single-family Dwelling 202 Detectable Warning 202 Diaphragms 202 Analysis 1604.4 Ceilings 2508.6
Penetrations 714
Permit application 105.1 Relocation 107.2.8
Retention 107.5
Review 107.3
Roof assemblies 1503
Roof live load 1603.1.2
Roof rain load data 1603.1.9
Roof snow load 1603.1.3
Seismic 1603.1.5, 1705.14.2, 1705.14.3 Site plan 107.2.6 Special loads 1603.1.8 Temporary structures 3103.2 Wind data 1603.1.4 Construction Types 202, Chapter 6 Aircraft-related occupancies 412.2.1, Table 412.3.6, 412.5.2 Classification 602 Combustible material in Type I and Type II construction 603, 805 Covered and open mall buildings 402.4.1 Fire district D102.2.3
Fire resistance Table 601, Table 705.5 High-rise 403.2 Type I Table 601, 602.2, 603 Type II Table 601, 602.2, 603 Type III Table 601, 602.3 Type IV Table 601, 602.4 Type V Table 601, 602.5 Underground buildings 405.2 Continuity Head-Of-Wall System 202 Continuous Insulation (ci) 202 Contractor’s Responsibilities 901.5, 1704.4 Control Area 414.2, 707.3.8 Construction 414.2.1
Fire-resistance rating 414.2.4 Maximum allowed quantities 414.2.2 Number 414.2.3 Conventional Light-frame Construction 2302.1, 2308 Additional seismic requirements 2308 Braced wall lines 2308.10 Design of elements 2308.8 Floor joists 2308.8.2 Foundation plates or sills 2308.7 Girders 2308.8.1 Roof and ceiling framing 2308.11 Wall framing 2308.9 Conveying System S3004 Cornices
Definition 202 Draftstopping 718.2.6 Live load Table 1607.1
Masonry 2104.1.2 Projection 705.2, 705.2.3.1 Public right-of-way encroachments 3202.3.2, 3202.3.3 Correctional Treatment Centers
[OSHPD 4] 1227 Application 1227.2 Ceiling heights 1227.8 Corridors 1227.5
CALGreen § 408.3 Medium relevance — show source text
2025 CALIFORNIA MECHANICAL CODE 79
), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.
VENTILATION AIR
408.3 Filters for Skilled Nursing Facilities, Intermedi- ate Care Facilities, and Correctional Treatment Centers.
408.3.1 The air ventilation systems for skilled nursing facilities, intermediate care facilities and correctional treatment centers shall have filter bank efficiencies as listed in Table 4-C.
408.3.2 Airborne infection isolation rooms, protective environment rooms, and sensitive areas in correctional treatment centers shall comply with Section 408.2. 408.4 Filters for Outpatient Facilities.
408.4.1 The air ventilation systems for outpatient facil- ities shall have filter bank efficiencies as listed in Table 4-B.
408.5 Filters for Recirculating Room Units.
408.5.1 Filters for recirculating room units shall comply with Section 407.4.5. Where Table 4-A does not permit air recirculated by means of room units, room units with filtration per Table 4-B are permitted.
409.0 Ducts. [OSHPD 1, 1R, 2, 3, 4 & 5]
409.1 Ducts which penetrate construction, intended for X- ray or other radiation protection, shall not impair the effec- tiveness of the protection.
409.2 Duct linings and their use shall meet the requirements of Chapter 6, California Mechanical Code.
409.3 The anchorage and supporting structural elements for airducts shall be designed to withstand the lateral forces as required by the California Building Code, Title 24, Part 2.
410.0 Laboratory Ventilating Systems and Hoods.
[OSHPD 1, 1R, 2, 3, 4 & 5]
410.1 Laboratory Ventilating Systems. Laboratory ven- tilating systems shall comply with NFPA 99, as required by Section 1224.4.6.4 of the California Building Code.
410.2 Exhaust Hoods and Safety Cabinets. Hoods and safety cabinets may be used for normal exhaust of a space pro- vided minimum air change rates are maintained. If air change standards in Table 4-A do not provide sufficient air for proper operation of exhaust hoods and safety cabinets (when in use), supplementary makeup air (filtered and preheated) shall be provided around these units to maintain the required airflow direction and exhaust velocity. Makeup systems for hoods shall be arranged to minimize “short circuiting” of air and to avoid reduction in air velocity at the point of contaminant capture.
410.3 Laboratory Fume Hoods. Laboratory fume hoods shall meet the following standards:
CRC § 2025 Medium relevance — show source text
2025 CALIFORNIA RESIDENTIAL CODE APPENDIX BH-1
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
APPENDIX BH-2 2025 CALIFORNIA RESIDENTIAL CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
BH AUTOMATIC VEHICULAR GATES
The provisions contained in this appendix are not mandatory unless specifically adopted by a state agency or referenced in the adopting ordinance.
User notes:
About this appendix: Appendix BH provides requirements for automatic vehicular gates, including a definition of and references to standards that regulate such gates.
SECTION BH101—GENERAL
BH101.1 General. The provisions of this appendix shall control the design and construction of automatic vehicular gates installed on the lot of a one- or two-family dwelling.
SECTION BH102—DEFINITION
BH102.1 General. The following term shall, for the purposes of this appendix, have the meaning shown herein.
VEHICULAR GATE. A gate that is intended for use at a vehicular entrance or exit to the lot of a one- or two-family dwelling, and that is not intended for use by pedestrian traffic.
SECTION BH103—AUTOMATIC VEHICULAR GATES
BH103.1 Vehicular gates intended for automation. Vehicular gates intended for automation shall be designed, constructed and installed to comply with the requirements of ASTM F2200.
BH103.2 Vehicular gate openers. Vehicular gate openers, where provided, shall be listed in accordance with UL 325.
SECTION BH104—REFERENCED STANDARDS
BH104.1 General. See Table BH104.1 for standards that are referenced in various sections of this appendix. Standards are listed by the standard identification with the effective date, the standard title, and the section or sections of this appendix that reference the standard.
TABLE BH104.1—REFERENCED STANDARDS Col2 Col3 STANDARD
ACRONYMSTANDARD NAME SECTIONS
HEREIN REFERENCEDASTM F2200—20 Standard Specification for Automated Vehicular Gate Construction BH103.1 UL 325—2017 Door, Drapery, Gate, Louver and
Window Operations and Systems—with Revisions through February 2020BH103.2 2025 CALIFORNIA RESIDENTIAL CODE APPENDIX BH-3
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
APPENDIX BH-4 2025 CALIFORNIA RESIDENTIAL CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE
APPENDIX BI – LIGHT STRAW-CLAY CONSTRUCTION
(Matrix Adoption Tables are nonregulatory, intended only as an aid to the code user. See Chapter 1 for state agency authority and building applications.)
CALGreen § 18-35 Medium relevance — show source text
2025 CALIFORNIA BUILDING CODE 18-35
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
SOILS AND FOUNDATIONS
6. The modulus of subgrade reactions, long-term settlement and post-earthquake settlement shall be specified along with expected total and differential settlements for design. 7. The acceptance criteria for friction cone and piezocone penetration testing in accordance with ASTM D5778 complemented by a standard penetration test (SPT) in accordance with ASTM D1586, if necessary, to verify soil improvement shall be specified 8. The requirements for special inspection and observation by the geotechnical engineer shall be specified. 9. A Final Verified Report (FVR) documenting the installation of the ground improvement system and confirming that the ground improvement acceptance criteria have been met shall be prepared by the geotechnical engineer and submitted to the enforce- ment agency for review and approval.
1813.3 Shallow Foundations. VSCs under the shallow foundation shall be located symmetrically around the centroid of the footing or load, and:
1. There shall be a minimum of four stone columns under each isolated or continuous/combined footing or an approved equivalent. 2. The VSCs or deep foundation elements shall not be used to resist tension or overturning uplift from the shallow foundations. 3. The foundation design for the shallow foundation shall consider the increased vertical stiffness of the VSCs as point supports for analysis, unless it is substantiated that the installation of the VSCs results in improvement of the surrounding soils such that the modulus of subgrade reaction, long-term settlement and post-earthquake settlement can be considered uniform throughout.
1813.4 Installation. VSCs shall be installed with vibratory probes. Vertical columns of compacted unbounded aggregate shall be formed through the soils to be improved by adding gravel near the tip of the vibrator and progressively raising and re-penetrating the vibrator, which will results in the gravel being pushed into the surrounding soil. Gravel aggregate for VSCs shall be well graded with a maximum size of 6 inches and not more than 10 percent smaller than [3] / 8 inch after compaction.
1813.5 Construction Documents. Construction documents for VSCs, at a minimum, shall include the following: 1. Size, depth and location of VSCs. 2. The extent of soil improvements along with building/structure foundation outlines. 3. Field verification requirements and acceptance criteria using CPT/SPT. 4. The locations where CPT/SPT shall be performed. 5. A Testing, Inspection and Observation (TIO) program indicating the inspection and observation required for the VSCs.
18-36 2025 CALIFORNIA BUILDING CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE
CHAPTER 18A – SOILS AND FOUNDATIONS
(Matrix Adoption Tables are nonregulatory, intended only as an aid to the code user. See Chapter 1 for state agency authority and building applications.)
Frequently asked questions
What exactly is listed in Chapter 6?
Chapter 6 lists the referenced organizations and each standard CALGreen cites (agency acronym, standard number, date/title) and shows the CALGreen sections that rely on each standard (see §601) .
Are the referenced standards automatically part of the code?
Referenced standards are treated as part of the code only to the extent they are cited by a CALGreen provision; the code and companion referenced‑standards chapters explain that the standard’s requirements apply only where the code references them .
How do I know which version of a standard applies on my project?
Use the entry in Chapter 6 (and related referenced‑standards tables) to confirm the standard number and effective date shown next to the CALGreen sections that reference it; where adoption or agency exceptions matter, consult the code’s matrix/adoption tables and the enforcement authority noted in the code .
More in California Green Building Standards Code (CALGreen)
- Administration (Chapter 1)
- Nonresidential Voluntary Measures (Appendix A5 — divisions A5.1–A5.6, electives & verification)
- Residential Mandatory Measures — Planning & Design; Energy; Water; Materials; Environmental Quality (Chapter 4)
- Definitions (Chapter 2)
- Voluntary Standards for Health Facilities (Appendix A6 / OSHPD guidance)
- Green Building – scope, mixed occupancies, phased projects (Chapter 3)
- Residential Voluntary Measures (Appendix A4 — divisions A4.1–A4.6, tiers & model ordinance)
- Nonresidential Mandatory Measures — Planning & Design; Energy; Water; Materials; Environmental Quality (Chapter 5)
- Compliance verification, construction documents & checklists (Section 102, Chapter 7, Appendix checklists)
- Referenced Organizations and Standards (Chapter 6)
- Voluntary Tiers and CALGreen Tier 1 / Tier 2 (performance tiers, thresholds)
- Installer and Special Inspector Qualifications (Chapter 7)
Ask about the CALGreen
Get cited, plain-English answers on the California Green Building Standards Code (CALGreen) for your project — any code section, any scenario.