CALGreen · California Green Building Standards Code (CALGreen)

What is the general scope and organization of CALGreen Chapter 3 (Green Building)?

Chapter 3 tells you that projects must include the mandatory green building measures listed in CALGreen’s checklists; voluntary measures are optional unless a city or county adopts them. The chapter explains how those measures apply to residential additions (when conditioned area/volume/size increases), nonresidential additions (thresholds: 1,000 sq ft or $200,000 valuation), and how to read banners (new vs. add/alter, LR/HR). **§ 301** and **§ 301.1** are the controlling sections.

Last reviewed: July 6, 2026

What the code requires — 2-4 sentences

Buildings must be designed to include the mandatory green building measures listed in the CALGreen application checklists; voluntary measures are provided but are not required unless a local jurisdiction adopts them. This requirement is stated in § 301.1 and the general Chapter 3 direction comes from § 301.

Buildings must incorporate the mandatory green building measures in the code’s application checklists; voluntary measures remain optional unless adopted locally. (Plain-English restatement of § 301.1.)

Requirements in detail

Key concepts (first use bolded)

  • Green building measures — the specific mandatory and voluntary measures presented in CALGreen application checklists. § 301 establishes that buildings shall be designed to include the mandatory measures.
  • Mandatory — measures that must be complied with as part of the state code (or as adopted by a local jurisdiction). § 301.1 states mandatory measures appear in the application checklists.
  • Voluntary — measures in the checklists that a locality may adopt to make them mandatory locally. § 301.1 explains voluntary measures may be included but are not required unless adopted under Section 101.7.
  • Conditioned area, volume or size — additions/alterations that increase a building’s conditioned area/volume/size trigger some Chapter 4 requirements (see § 301.1.1).

How Chapter 3 is organized (high level)

  • Chapter 3 opens with Section 301 — General, including the scope and how mandatory vs voluntary measures are applied. § 301 / § 301.1.
  • The chapter contains short, focused sections that control:
    • Applicability to residential additions/alterations (see § 301.1.1) — limited to the added/altered area when conditioned area/volume/size increases.
    • Low-rise vs high‑rise designations and banners indicating applicability (see § 301.2).
    • Nonresidential additions/alterations thresholds and scoping (see § 301.3).
    • Other brief sections on mixed occupancies, phased projects, voluntary tiers and health-facility specifics (see §§ 302–306, and § 301.5 for health facilities).

Decision-relevant table

Decision question Key value / threshold Code Reference
Are mandatory checklists required for the project? Yes — design must include mandatory measures from application checklists § 301 / § 301.1
Do voluntary measures apply automatically? No — voluntary measures are optional unless adopted locally under Section 101.7 § 301.1
When do Chapter 4 mandatory residential rules apply to an addition/alteration? When the work increases conditioned area, volume or size (applies only to the area of the addition/alteration) § 301.1.1
Nonresidential addition threshold for Chapter 5 measures ≥ 1,000 sq ft addition OR alteration with permit valuation ≥ $200,000 (scoping applies only to the portion being added/altered) § 301.3
How are sections marked when they only apply to new construction or to additions/alterations? Code sections use banners [N] for new construction, [A] for additions/alterations; when both apply, no banner. § 301.3
Low‑rise vs high‑rise applicability flags Sections will carry LR or HR banners when limited to one category; no banner = applies to both § 301.2

Exceptions & special cases

  • Repairs (e.g., resurfacing, restriping, maintaining existing lighting) are explicitly not considered alterations for the purpose of the additions/alterations rule in § 301.1.1; so these minor repairs do not trigger the addition/alteration scoping.
  • For nonresidential work, only the portions of the building that are being added or altered are subject to the applicable Chapter 5 requirements; whole-building measures do not automatically apply to untouched portions. § 301.3 explains this scoping.
  • Local jurisdictions may adopt voluntary tiers or other voluntary measures as mandatory by ordinance (see cross-reference to Section 101.7 and the voluntary tiers provisions in § 304).

Common mistakes

  • Assuming all voluntary measures in CALGreen are mandatory statewide — they are optional unless locally adopted (contrary assumption ignores § 301.1).
  • Applying Chapter 4 mandatory residential measures to an addition/alteration that does not increase the building’s conditioned area, volume or size§ 301.1.1 limits application to projects that increase those metrics.
  • Treating nonresidential scope thresholds as nationwide for all work types — § 301.3 limits Chapter 5 application to newly constructed buildings, additions ≥ 1,000 sq ft, or alterations with valuation ≥ $200,000, and only to the work area.
  • Missing the banners: failing to check for [N] (new), [A] (add/alter), LR/HR banners can cause misapplication of a section. § 301.3 and § 301.2 explain banner usage.

Worked example — concrete scenario

Scenario: A developer plans a 900 sq ft conditioned addition to a multifamily low‑rise building; permit valuation is $85,000.

  • Step 1 — Is Chapter 4 residential mandatory measures triggered for the addition? Yes, because the addition increases conditioned area; § 301.1.1 says Chapter 4 mandatory provisions apply where conditioned area/volume/size increases, and they apply to the specific area of the addition. So the 900 sq ft addition must meet the Chapter 4 mandatory checklists for that added area.
  • Step 2 — Are Chapter 5 nonresidential thresholds relevant? No — § 301.3 sets the nonresidential addition threshold at 1,000 sq ft (and/or $200,000 valuation). This 900 sq ft addition and $85k valuation do not meet the Chapter 5 scoping thresholds, so Chapter 5 scoping for nonresidential mandatory measures is not triggered.
  • Step 3 — Do voluntary measures apply? Only if the local jurisdiction has adopted them under Section 101.7; otherwise they remain voluntary per § 301.1.

Related provisions

  • § 301.1.1 — Additions and alterations (residential scoping).
  • § 301.2 — Low‑rise and high‑rise residential applicability / banners (LR / HR).
  • § 301.3 — Nonresidential additions and alterations scoping (1,000 sq ft / $200,000 thresholds; banners [N]/[A]).
  • § 302.1 — Mixed occupancy buildings: each occupancy portion must comply with its applicable green building measures.
  • § 303.1 — Phased projects and the treatment of shell buildings and initial tenant improvements.
  • § 304 — Voluntary tiers (purpose and adoption).
  • § 301.5 — Health facility outdoor water use requirement note and submission to OSHPD.

Code references

Grounded in the retrieved California Green Building Standards Code (CALGreen) — click a citation to read the verbatim passage:

  • CALGreen § 1-5 High relevance — show source text

    102 Construction Documents

    and Installation Verification . . . . . . . . . . . . . . . . . . . .1-5

    103 Building Standards Commission. . . . . . . . . . . . . . . . . . .1-5 104 Department of Housing and Community Development. . . . . . . . . . . . . . . . . .1-6 105 Division of the State Architect . . . . . . . . . . . . . . . . . . . . .1-6

    106 Office of Statewide Health Planning and Development . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-6

    CHAPTER 2 DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3

    201 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3

    202 Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3

    CHAPTER 3 GREEN BUILDING . . . . . . . . . . . . . . . . . . . . . . . . 3-3

    301 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-3

    302 Mixed Occupancy Buildings . . . . . . . . . . . . . . . . . . . . . . .3-4 303 Phased Projects. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4 304 Voluntary Tiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4 305 CALGreen Tier 1 and CALGreen Tier 2 . . . . . . . . . . . . . .3-4

    306 Voluntary Measures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4

    CHAPTER 4 RESIDENTIAL MANDATORY MEASURES . . . . . . 4-3

    4.1 Planning and Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-3 4.2 Energy Efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-7 4.3 Water Efficiency and Conservation . . . . . . . . . . . . . . . . .4-9 4.4 Material Conservation and Resource Efficiency . . . . 4-11 4.5 Environmental Quality . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13

    CHAPTER 5 NONRESIDENTIAL MANDATORY MEASURES . . 5-3

  • CALGreen § 3-4 Medium relevance — show source text

    302 Mixed Occupancy Buildings . . . . . . . . . . . . . . . . . . . . . . .3-4 303 Phased Projects. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4 304 Voluntary Tiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4 305 CALGreen Tier 1 and CALGreen Tier 2 . . . . . . . . . . . . . .3-4

    306 Voluntary Measures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4

    CHAPTER 4 RESIDENTIAL MANDATORY MEASURES . . . . . . 4-3

    4.1 Planning and Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-3 4.2 Energy Efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-7 4.3 Water Efficiency and Conservation . . . . . . . . . . . . . . . . .4-9 4.4 Material Conservation and Resource Efficiency . . . . 4-11 4.5 Environmental Quality . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13

    CHAPTER 5 NONRESIDENTIAL MANDATORY MEASURES . . 5-3

    5.1 Planning and Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-3 5.2 Energy Efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-15 5.3 Water Efficiency and Conservation . . . . . . . . . . . . . . . 5-19 5.4 Material Conservation and Resource Efficiency . . . . 5-23 5.5 Environmental Quality . . . . . . . . . . . . . . . . . . . . . . . . . . 5-31

    CHAPTER 6 REFERENCED ORGANIZATIONS

    AND STANDARDS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3

    601 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-3

    CHAPTER 7 INSTALLER AND SPECIAL

    INSPECTOR QUALIFICATIONS . . . . . . . . . . . . . . . . . . . . . . 7-3 701 General (Reserved) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-3 702 Qualifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-3

  • CALGreen § 409.4 Medium relevance — show source text

    Solar access is the ratio of solar insolation including shade to the
    solar insolation without shade. Shading from obstructions located on the roof or any other part of the building shall not be included in the determination of annual solar access.
    3.
    Life cycle assessment compliant with Section A5.409.4 in this code may be substituted for prescriptive measures from Division A5.4.|

    A5.601.1 Scope. The measures contained in this appendix are not mandatory unless adopted by local government as specified in Section 101.7. The provisions of this section outline means of achieving enhanced construction or reach levels by incorporating addi

    2025 CALIFORNIA GREEN BUILDING STANDARDS CODE APPENDIX A5-41

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    APPENDIX A5NONRESIDENTIAL VOLUNTARY MEASURES

    tional green building measures for newly constructed nonresidential buildings as well as additions and alterations. In order to meet one of the tier levels designers, builders or property owners are required to incorporate additional green building measures necessary to meet the threshold of each level. Refer to the provisions in Section 301.3 for nonresidential additions and alterations scope and application.

    A5.601.2 CALGreen Tier 1

    A5.601.2.1 Prerequisites. To achieve CALGreen tier status, a project must meet all of the mandatory measures in Chapter 5 and, in addition, meet the provisions of this section.

    A5.601.2.2 Energy performance. For the purposes of mandatory energy efficiency standards in this code, the California Energy Commission will continue to adopt mandatory standards.

    A5.601.2.3 Tier 1. Comply with the energy efficiency requirements in Section A5.203.1.1 and Section A5.203.1.2.1.

    A5.601.2.4 Voluntary measures for Tier 1. In addition to the provisions of Sections A5.601.2.1 and A5.601.2.3 above, compliance with the following voluntary measures from Appendix A5 is required for Tier 1:

    1. From Division A5.1, a. Comply with the designated parking requirements for high-efficiency vehicles for a minimum of 35 percent of parking capacity per Section A5.106.5.1. b. Electric vehicle (EV) charging [N] and Table A5.106.5.3.1 w/ footnotes. c. Comply with thermal emittance, solar reflectance or SRI values for cool roofs in Section A5.106.11.2 and Table A5.106.11.2.2. [1]

    d. Comply with one elective measure selected from this division. 2. From Division A5.2 comply with ONE of the following:

    1. Outdoor lighting as described in A5.203.1.1.1.

    2. Service water heating in restaurants as described in A5.203.1.1.2.

    3. Warehouse Dock Seal Doors A5.203.1.1.3.

    4. Daylight Design Power Adjustments 5.203.1.1.4.

    5. Exhaust Air Heat Recovery A5.203.1.1.5.

    6. From Division A5.3,

    a. Comply with the 12-percent reduction for indoor potable water use in Section A5.303.2.3.1. b. Comply with one elective measure selected from this division.

    1. From Division A5.4,
  • CALGreen § 304.1 Medium relevance — show source text

    SECTION 304—VOLUNTARY TIERS

    304.1 Purpose. Voluntary tiers are intended to further encourage building practices that improve public health, safety and general welfare by promoting the use of building concepts which minimize the building’s impact on the environment and promote a more sustainable design.

    304.1.1 Tiers. The provisions of Divisions A4.6 and A5.6 outline means, in the form of voluntary tiers, for achieving enhanced construction levels by incorporating additional measures for residential and nonresidential new construction. Voluntary tiers may be adopted by local governments and, when adopted, enforced by local enforcing agencies. Buildings complying with tiers specified for each occupancy contain additional prerequisite and elective green building measures necessary to meet the threshold of each tier. See Section 101.7 of this code for procedures and requirements related to local amendments, additions or deletions, including changes to energy standards.

    [BSC & HCD] Where there are practical difficulties involved in complying with the threshold levels of a tier, the enforcing agency may grant modifications for individual cases. The enforcing agency shall first find that a special individual reason makes the strict letter of the tier impractical and that modification is in conformance with the intent and purpose of the measure. The details of any action granting modification shall be recorded and entered in the files of the enforcing agency.

    SECTION 305 [OSHPD 1]— CALGreen TIER 1 AND CALGreen TIER 2

    305.1 CALGreen Tier 1 and CALGreen Tier 2 buildings contain voluntary green building measures necessary to meet the threshold of each level.

    305.1.1 CALGreen Tier 1. To achieve CALGreen Tier 1, buildings must comply with the latest edition of “Savings By Design, Healthcare Modeling Procedures” found online at http://www.energysoft.com/main/page_ downloads_ sbd_healthcare.html.

    305.1.2 CALGreen Tier 2. To achieve CALGreen Tier 2, buildings must exceed the latest edition of “Savings By Design, Healthcare Modeling Procedures” by a minimum of 15 percent.

    SECTION 306 [DSA-SS]—VOLUNTARY MEASURES

    306.1 Purpose. For public schools and community colleges, voluntary measures further encourage building practices that improve public health, safety and general welfare by promoting the use of building concepts which minimize the building’s impact on the environment and promote a more sustainable design.

    306.1.1 Appendix A5, Divisions A5.1 through A5.5, outline means of achieving enhanced sustainable design and construction by incorporating voluntary measures that exceed the mandatory measures.

    306.1.2 Chapter 5 Nonresidential Mandatory Measures that are not adopted as mandatory measures by DSA-SS are voluntary measures recommended and encouraged for the design, construction, verification and maintenance of non-energy systems.

    Note: The building commissioning requirements for energy efficiency specified in the California Energy Code are required.

    3-4 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    CALIFORNIA GREEN BUILDING STANDARDS CODE – MATRIX ADOPTION TABLE

    CHAPTER 4 – RESIDENTIAL MANDATORY MEASURES

    (Matrix Adoption Tables are nonregulatory, intended only as an aid to the code user. See Chapter 1 for state agency authority and building applications.)

  • CALGreen § 409.4 Medium relevance — show source text

    Shading from obstructions located on the roof or any other part of the building shall not be included in the determination of annual solar access.
    3.
    Life cycle assessment compliant with Section A5.409.4 in this code may be substituted for prescriptive measures from Division A5.4.|1.
    Exception: Allowance may be permitted in Tier 2 for up to 5-percent specialty purpose flooring.
    2.
    Solar water-heating system requirement for newly constructed restaurants as per A5.203.1.1.2.
    Exceptions:
    a. Buildings with a natural gas service water heater with a minimum of 95-percent thermal efficiency.
    b. Buildings where greater than 75 percent of the total roof area has annual solar access that is less than 70 percent. Solar access is the ratio of solar insolation including shade to the
    solar insolation without shade. Shading from obstructions located on the roof or any other part of the building shall not be included in the determination of annual solar access.
    3.
    Life cycle assessment compliant with Section A5.409.4 in this code may be substituted for prescriptive measures from Division A5.4.|1.
    Exception: Allowance may be permitted in Tier 2 for up to 5-percent specialty purpose flooring.
    2.
    Solar water-heating system requirement for newly constructed restaurants as per A5.203.1.1.2.
    Exceptions:
    a. Buildings with a natural gas service water heater with a minimum of 95-percent thermal efficiency.
    b. Buildings where greater than 75 percent of the total roof area has annual solar access that is less than 70 percent. Solar access is the ratio of solar insolation including shade to the
    solar insolation without shade. Shading from obstructions located on the roof or any other part of the building shall not be included in the determination of annual solar access.
    3.
    Life cycle assessment compliant with Section A5.409.4 in this code may be substituted for prescriptive measures from Division A5.4.|

    A5.601.1 Scope. The measures contained in this appendix are not mandatory unless adopted by local government as specified in Section 101.7. The provisions of this section outline means of achieving enhanced construction or reach levels by incorporating addi

    2025 CALIFORNIA GREEN BUILDING STANDARDS CODE APPENDIX A5-41

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    APPENDIX A5NONRESIDENTIAL VOLUNTARY MEASURES

    tional green building measures for newly constructed nonresidential buildings as well as additions and alterations. In order to meet one of the tier levels designers, builders or property owners are required to incorporate additional green building measures necessary to meet the threshold of each level. Refer to the provisions in Section 301.3 for nonresidential additions and alterations scope and application.

    A5.601.2 CALGreen Tier 1

    A5.601.2.1 Prerequisites. To achieve CALGreen tier status, a project must meet all of the mandatory measures in Chapter 5 and, in addition, meet the provisions of this section.

    A5.601.2.2 Energy performance. For the purposes of mandatory energy efficiency standards in this code, the California Energy Commission will continue to adopt mandatory standards.

  • CALGreen § 301.1.1 Medium relevance — show source text

    1||||X||||X||||||||||||||| |301.1.1||||X||||||||||||||||||| |301.2||||X||||||||||||||||||| |301.3||X||||||||||||||||||||| |301.3.1||X||||||||||||||||||||| |301.3.2||X||||||||||||||||||||| |301.4||||||||X||||||||||||||| |301.5|||||||||X||X||X|||||||||| |302||X||X||||X|X||X||X|||||||||| |303||X||X|||||X||X||X|||||||||| |303.1||X||||||||||||||||||||| |304||X||X|||||X||X||X|||||||||| |305|||||||||X|||||||||||||| |306||||||||X|||||||||||||||

    2025 CALIFORNIA GREEN BUILDING STANDARDS CODE 3-1

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    3-2 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    3 GREEN BUILDING

    SECTION 301—GENERAL

    301.1 Scope. Buildings shall be designed to include the green building measures specified as mandatory in the application checklists contained in this code. Voluntary green building measures are also included in the application checklists and may be included in the design and construction of structures covered by this code, but are not required unless adopted by a city, county, or city and county as specified in Section 101.7.

    301.1.1 Additions and alterations. [HCD] The mandatory provisions of Chapter 4 shall be applied to additions or alterations of existing residential buildings where the addition or alteration increases the building’s conditioned area, volume or size. The requirements shall apply only to and/or within the specific area of the addition or alteration.

    The mandatory provisions of Section 4.106.4.2 may apply to additions or alterations of existing parking facilities or the addition of new parking facilities serving existing multifamily buildings. See Section 4.106.4.3 for application.

    Note: Repairs including, but not limited to, resurfacing, restriping, and repairing or maintaining existing lighting fixtures are not considered alterations for the purpose of this section.

    301.2 Low-rise and high-rise residential buildings. [HCD] The provisions of individual sections of CALGreen may apply to either low-rise residential buildings, high-rise residential buildings, or both. Individual sections will be designated by banners to indicate where the section applies specifically to low-rise only (LR) or high-rise only (HR). When the section applies to both low-rise and highrise buildings, no banner will be used.

    301.3 Nonresidential additions and alterations. [BSC-CG] The provisions of individual sections of Chapter 5 apply to newly constructed buildings, building additions of 1,000 square feet or greater, and/or building alterations with a permit valuation of $200,000 or above (for occupancies within the authority of California Building Standards Commission). Code sections relevant to additions and alterations shall only apply to the portions of the building being added or altered within the scope of the permitted work.

    A code section will be designated by a banner to indicate where the code section only applies to newly constructed buildings [N] or to additions and/or alterations [A] . When the code section applies to both, no banner will be used.

  • CALGreen § 301.5 Medium relevance — show source text

    301.5 Health Facilities. [OSHPD 1, 2 & 4] Health facilities under the jurisdiction of the Office of Statewide Health Planning and Development (OSHPD) are required to comply with the mandatory measures prescribed in Section 5.304, Outdoor Water Use. Compliance with Section 5.304, as adopted by the Building Standards Commission, is enforced by the local agency having jurisdiction. Evidence of local approval shall be submitted to OSHPD prior to issuance of plan approval or a building permit.

    2025 CALIFORNIA GREEN BUILDING STANDARDS CODE 3-3

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    GREEN BUILDING

    SECTION 302—MIXED OCCUPANCY BUILDINGS

    302.1 Mixed occupancy buildings. In mixed occupancy buildings, each portion of a building shall comply with the specific green building measures applicable to each specific occupancy.

    Exceptions:

    1. [HCD] Accessory structures and accessory occupancies serving residential buildings shall comply with Chapter 4 and Appendix A4, as applicable.
    2. [HCD] For the purposes of CALGreen, live/work units, complying with Section 508.5 of the California Building Code, shall not be considered mixed occupancies. Live/work units shall comply with Chapter 4 and Appendix A4, as applicable.

    SECTION 303—PHASED PROJECTS

    303.1 Phased projects. For shell buildings and others constructed for future tenant improvements, only those code measures relevant to the building components and systems considered to be new construction (or newly constructed) shall apply.

    303.1.1 Initial tenant improvements. The provisions of this code shall apply only to the initial tenant improvements to a project. Subsequent tenant improvements shall comply with the scoping provisions in Section 301.3 nonresidential additions and alterations.

    SECTION 304—VOLUNTARY TIERS

    304.1 Purpose. Voluntary tiers are intended to further encourage building practices that improve public health, safety and general welfare by promoting the use of building concepts which minimize the building’s impact on the environment and promote a more sustainable design.

    304.1.1 Tiers. The provisions of Divisions A4.6 and A5.6 outline means, in the form of voluntary tiers, for achieving enhanced construction levels by incorporating additional measures for residential and nonresidential new construction. Voluntary tiers may be adopted by local governments and, when adopted, enforced by local enforcing agencies. Buildings complying with tiers specified for each occupancy contain additional prerequisite and elective green building measures necessary to meet the threshold of each tier. See Section 101.7 of this code for procedures and requirements related to local amendments, additions or deletions, including changes to energy standards.

    [BSC & HCD] Where there are practical difficulties involved in complying with the threshold levels of a tier, the enforcing agency may grant modifications for individual cases. The enforcing agency shall first find that a special individual reason makes the strict letter of the tier impractical and that modification is in conformance with the intent and purpose of the measure. The details of any action granting modification shall be recorded and entered in the files of the enforcing agency.

    SECTION 305 [OSHPD 1]— CALGreen TIER 1 AND CALGreen TIER 2

    305.1 CALGreen Tier 1 and CALGreen Tier 2 buildings contain voluntary green building measures necessary to meet the threshold of each level.

  • CALGreen § 602.1 Medium relevance — show source text

    VOLUNTARY MEASURES. . . . . . . . . . . . . . . . . APPENDIX A5-3

    A5.1 Planning and Design . . . . . . . . . . . . . . . . . APPENDIX A5-3 A5.2 Energy Efficiency . . . . . . . . . . . . . . . . . . . APPENDIX A5-13 A5.3 Water Efficiency and Conservation . . . APPENDIX A5-19 A5.4 Material Conservation and Resource Efficiency . . . . . . . . . . . . . . . . . . . . . . . . APPENDIX A5-25 A5.5 Environmental Quality . . . . . . . . . . . . . . APPENDIX A5-35 A5.6 Voluntary Tiers . . . . . . . . . . . . . . . . . . . . . APPENDIX A5-41 A5.601 CALGren Tier 1 and Tier 2. . . . . . . . . . APPENDIX A5-41

    A5.602 CALGreen Verification Guidelines Mandatory Measures Checklist . . . . . . . . . . . . . . . APPENDIX A5-44

    A5.602.1 CALGreen Verification Guidelines

    Tier 1 Checklist . . . . . . . . . . . . . . . . . APPENDIX A5-48

    A5.602.2 CALGreen Verification Guidelines

    Tier 2 Checklist . . . . . . . . . . . . . . . . . APPENDIX A5-55

    APPENDIX A6 VOLUNTARY STANDARDS FOR HEALTH

    FACILITIES [OSHPD 1, 2 & 4] . . . . . . . . . . . APPENDIX A6.1-3 A6.1 Site Planning and Design . . . . . . . . . . . APPENDIX A6.1-3 A6.2 Energy Efficiency . . . . . . . . . . . . . . . . . . APPENDIX A6.1-3 A6.4 Material Conservation and Resource Efficiency . . . . . . . . . . . . . APPENDIX A6.1-32 A6.5 Environmental Quality . . . . . . . . . . . . APPENDIX A6.1-33

    INDEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INDEX-1

    HISTORY NOTE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HIST-1

    2025 CALIFORNIA GREEN BUILDING STANDARDS CODE vii

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    viii 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    CALIFORNIA GREEN BUILDING STANDARDS CODE – MATRIX ADOPTION TABLE

    CHAPTER 1 – ADMINISTRATION

    (Matrix Adoption Tables are nonregulatory, intended only as an aid to the code user. See Chapter 1 for state agency authority and building applications.)

    |Adopting

  • CALGreen § 305.1.2 Medium relevance — show source text

    305.1.2 CALGreen Tier 2. To achieve CALGreen Tier 2, buildings must exceed the latest edition of “Savings By Design, Healthcare Modeling Procedures” by a minimum of 15 percent.

    SECTION 306 [DSA-SS]—VOLUNTARY MEASURES

    306.1 Purpose. For public schools and community colleges, voluntary measures further encourage building practices that improve public health, safety and general welfare by promoting the use of building concepts which minimize the building’s impact on the environment and promote a more sustainable design.

    306.1.1 Appendix A5, Divisions A5.1 through A5.5, outline means of achieving enhanced sustainable design and construction by incorporating voluntary measures that exceed the mandatory measures.

    306.1.2 Chapter 5 Nonresidential Mandatory Measures that are not adopted as mandatory measures by DSA-SS are voluntary measures recommended and encouraged for the design, construction, verification and maintenance of non-energy systems.

    Note: The building commissioning requirements for energy efficiency specified in the California Energy Code are required.

    3-4 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    CALIFORNIA GREEN BUILDING STANDARDS CODE – MATRIX ADOPTION TABLE

    CHAPTER 4 – RESIDENTIAL MANDATORY MEASURES

    (Matrix Adoption Tables are nonregulatory, intended only as an aid to the code user. See Chapter 1 for state agency authority and building applications.)

    Adopting agency BSC BSC-
    CG
    SFM HCD Col6 Col7 DSA Col9 OSHPD Col11 Col12 Col13 Col14 Col15 BSCC DPH AGR DWR CEC CA SL SLC
    Adopting agency BSC BSC-
    CG
    SFM 1 2 1/AC AC SS 1 1R 2 3 4 5 5 5 5 5 5 5 5 5
    Adopt entire CA chapter X
    Adopt entire chapter as
    amended (amended
    sections listed below)
    Adopt only those sections
    that are listed below
    X
    Chapter/Section
    Division 4.2 X

    The state agency does not adopt sections identified by the following symbol: †.

    2025 CALIFORNIA GREEN BUILDING STANDARDS CODE 4-1

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    4-2 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

  • CALGreen § 568-3800 Medium relevance — show source text

    Office of the State Fire Marshal [SFM]

    osfm.fire.ca.gov codedevelopment@fire.ca.gov

    (916) 568-3800 Fire & Life Safety

    State Lands Commission [SLC]

    slc.ca.gov MOTEMS.Public@slc.ca.gov (510) 741-4950 Marine Oil Terminals

    State Librarian [SL]

    library.ca.gov csllaw@library.ca.gov (916) 323-9843 Public Library Construction & Renovation

    2025 CALIFORNIA GREEN BUILDING STANDARDS CODE v

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    HOW TO DETERMINE WHERE CHANGES HAVE BEEN MADE

    Symbols in the margins indicate where changes have been made or language has been deleted.

    This symbol indicates that a change has been made.

    • This symbol indicates deletion of language.

    vi 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    CONTENTS

    CHAPTER 1 ADMINISTRATION . . . . . . . . . . . . . . . . . . . . . . . . 1-3

    101 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3

    102 Construction Documents

    and Installation Verification . . . . . . . . . . . . . . . . . . . .1-5

    103 Building Standards Commission. . . . . . . . . . . . . . . . . . .1-5 104 Department of Housing and Community Development. . . . . . . . . . . . . . . . . .1-6 105 Division of the State Architect . . . . . . . . . . . . . . . . . . . . .1-6

    106 Office of Statewide Health Planning and Development . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-6

    CHAPTER 2 DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3

    201 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3

    202 Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3

    CHAPTER 3 GREEN BUILDING . . . . . . . . . . . . . . . . . . . . . . . . 3-3

    301 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-3

  • CALGreen § 15-11 Medium relevance — show source text

    are listed below||||||||X||||||||||||||| |Chapter/Section||||||||||||||||||||||| |WS-3||||||||X||||||||||||||| |WS-4||||||||X||||||||||||||| |WS-5||||||||X||||||||||||||| |WS-9||||||||X||||||||||||||| |IES TM-15-11 Table A-1||||||||X||||||||||||||| |Table 130.2-A||||||||X||||||||||||||| |Table 1302.2-B||||||||X|||||||||||||||

    2025 CALIFORNIA GREEN BUILDING STANDARDS CODE 8-1

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    8-2 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    8 COMPLIANCE FORMS, WORKSHEETS AND REFERENCE MATERIAL

    [BSC] Sample forms found in “A Guide to the California Green Building Standards Code (Nonresidential)” located at https://www.dgs.ca.gov/BSC/Resources/Page-Content/Building-Standards-Commission-Resources-List-Folder/CALGreen may be used to assist in documenting compliance with the waste management plan and other provisions of this code.

    [HCD 1] Sample forms located at www.hcd.ca.gov/building-standards/calgreen/cal-green-forms.shtml may be used to assist in documenting compliance with CALGreen . WORKSHEET (WS-1) BASELINE WATER USE

    BASELINE WATER USE CALCULATION TABLE Col2 Col3 Col4 Col5 Col6 Col7 Col8 Col9 Col10
    FIXTURE TYPE FLOW RATE DURATION DAILY USES OCCUPANTS1 GALLONS PER DAY
    Showerheads 1.8 gpm @ 80 psi × 5 min. × 1 × Note 1a =
    Lavatory faucets nonresidential 0.5 gpm @ 60 psi × .25 min. × 3 × =
    Kitchen faucets 1.8 gpm @ 60 psi × 4 min. × 1 × Note 1b =
    Replacement aerators 2.2 gpm × × × =
    Wash fountains 1.8 gpm/20 [rim
    space(in.)@ 60 psi]
    × × × =
    Metering faucets 0.20 gal/cycle × × 3 × =
    Metering faucets for wash
    fountains
    0.20 gal/cycle/20 [rim
    space(in.
  • CALGreen § 2-11 Medium relevance — show source text

    WATTLES. Wattles are used to reduce sediment in runoff. Wattles are often constructed of natural plant materials such as hay, straw or similar material shaped in the form of tubes and placed on a downflow slope. Wattles are also used for perimeter and inlet controls.

    ZEV. [BSC-CG, DSA-SS] Any vehicle certified to zero-emission standards.

    ZERO-EMITTING AND HIGH-EFFICIENCY VEHICLES. [BSC-CG, DSA-SS] Eligible vehicles are limited to the following:

    1. Zero emission vehicle (ZEV), enhanced advanced technology PZEV (enhanced AT ZEV) or transitional zero emission vehicles (TZEV) regulated under CCR, Title 13, Section 1962.
    2. High-efficiency vehicles, regulated by US EPA, bearing a fuel economy and greenhouse gas rating of 9 or 10 as regulated under 40 CFR Section 600 Subpart D.

    2025 CALIFORNIA GREEN BUILDING STANDARDS CODE 2-11

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    2-12 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    CALIFORNIA GREEN BUILDING STANDARDS CODE – MATRIX ADOPTION TABLE

    CHAPTER 3 – GREEN BUILDING

    (Matrix Adoption Tables are nonregulatory, intended only as an aid to the code user. See Chapter 1 for state agency authority and building applications.)

    Adopting agency BSC BSC-
    CG
    SFM HCD Col6 Col7 DSA Col9 OSHPD Col11 Col12 Col13 Col14 Col15 BSCC DPH AGR DWR CEC CA SL SLC
    Adopting agency BSC BSC-
    CG
    SFM 1 2 1/AC AC SS 1 1R 2 3 4 5 5 5 5 5 5 5 5 5
    Adopt entire CA chapter
    Adopt entire chapter as
    amended (amended
    sections listed below)
    Adopt only those sections that
    are listed below
    X X X X X X
    Chapter/Section
    301 X X X X
    301.1 X X
    301.1.1 X
    301.2 X
    301.3 X
    301.3.1 X
    301.3.2 X
    301.4 X
    301.

Frequently asked questions

Who decides whether voluntary measures become mandatory?

Local jurisdictions (city/county/city-and-county) may adopt voluntary measures as mandatory by following the adoption process in Section 101.7; until adopted they remain optional per § 301.1.

Does a minor repair trigger CALGreen additions/alterations requirements?

No. § 301.1.1 explicitly states routine repairs (e.g., resurfacing, restriping, maintaining existing lighting) are not considered alterations for this purpose.

If a building is mixed‑use, do I apply one occupancy’s measures to the whole building?

No. § 302.1 requires each portion to comply with the green building measures applicable to that occupancy.

What banner should I look for to know applicability to new vs altered work?

Look for banners [N] for provisions that apply only to new construction and [A] for additions/alterations; when a section applies to both, it has no banner (see § 301.3).

Does Chapter 3 itself list the specific mandatory measures?

Chapter 3 sets scope and organization; the specific mandatory measures are organized in the application checklists and the mandatory chapters (for example, Chapter 4 and Chapter 5). § 301 / § 301.1 direct use of the application checklists.

More in California Green Building Standards Code (CALGreen)

Ask about the CALGreen

Get cited, plain-English answers on the California Green Building Standards Code (CALGreen) for your project — any code section, any scenario.

Start Free Trial

Related in the CALGreen