Chapter 5 — WATER HEATERS

504.1 Location.

California Plumbing Code (Title 24, Part 5) · 2025 edition · updated 2026-09-12 · California

Italicized text is a California amendment to the model code, as printed in the official publication.

Water heater installations in bedrooms and

bathrooms shall comply with one of the following [NFPA 54:10.27.1]:

(1) Water heater shall be of the direct-vent type. [NFPA 54:10.27.1(2)]

(2) Fuel-burning water heaters shall be permitted to be installed in a closet located in the bedroom or bathroom provided the closet is equipped with a listed, gasketed door assembly and a listed self-closing device. The selfclosing door assembly shall meet the requirements of Section 504.1.1. The door assembly shall be installed with a threshold and bottom door seal and shall meet the requirements of Section 504.1.2. Combustion air for such installations shall be obtained from the outdoors in accor dance with Section 506.4. The closet shall be for the

exclusive use of the water heater.

504.1.1 Self-Closing Doors. Self-closing doors shall swing easily and freely, and shall be equipped with a self-closing device to cause the door to close and latch each time it is opened. The closing mechanism shall not have a hold-open feature.

504.1.2 Gasketing. Gasketing on gasketed doors or frames shall be furnished in accordance with the published listings of the door, frame, or gasketing material manufacturer.

TABLE 501.1(2) FIRST HOUR RATING [1]

Number of Bathrooms 1 to 1.5 2 to 2.5 3 to 3.5
Number of Bedrooms 1 2 3 2 3 4 5 3 4 5 6
First Hour Rating,2 Gallons 38 49 49 49 62 62 74 62 74 74 74

For SI units: 1 gallon = 3.785 L

Notes: 1 The first-hour rating is found on the “Energy Guide” label. 2 Solar water heaters shall be sized to meet the appropriate first-hour rating as shown in the table.

WATER HEATERS

Exception: Where acceptable to the Authority Having Jurisdiction, gasketing of non-combustible or limitedcombustible material shall be permitted to be applied to the frame, provided closing and latching of the door are not inhibited.

Get a plain-English answer with a citation back to this text.

Ask AI about this code
Contents — California Plumbing Code (Title 24, Part 5)
California Plumbing Code (Title 24, Part 5)
  1. Chapter 1 — GENERAL CODE PROVISIONS
  2. Chapter 2 — DEFINITIONS
  3. Chapter 3 — GENERAL REGULATIONS
  4. Chapter 4 — PLUMBING FIXTURES AND FIXTURE FITTINGS
  5. Chapter 5 — WATER HEATERS
    Overview
    1. 501.1 Applicability.
    2. 501.2 California Energy Code Water Heating System
    3. 502.1 General.
    4. 503.1 Inspection of Chimneys or Vents.
    5. 503.2 Final Water Heater Inspection.
    6. 504.1 Location.
    7. 504.2 Vent.
    8. 504.3 Clearance.
    9. 504.4 Pressure-Limiting Devices.
    10. 504.5 Temperature Limiting Devices.
    11. 504.6 Temperature, Pressure, and Vacuum Relief Devices.
    12. 504.7 Lead Content.
    13. 505.1 Water Heaters.
    14. 505.2 Safety Devices.
    15. 505.3 Oil-Fired Water Heaters.
    16. 505.4 Indirect-Fired Water Heaters.
    17. 506.1 General.
    18. 506.2 Indoor Combustion Air.
    19. 506.3 Indoor Opening Size and Location.
    20. 506.4 Outdoor Combustion Air.
    21. 506.5 Combination Indoor and Outdoor Combustion Air.
    22. 506.6 Engineered Installations.
    23. 506.7 Mechanical Combustion Air Supply.
    24. 506.8 Louvers, Grilles, and Screens.
    25. 506.9 Combustion Air Ducts.
    26. 507.1 Dielectric Insulator.
    27. 507.2 Seismic Provisions.
    28. 507.3 Appliance Support.
    29. 507.4 Ground Support.
    30. 507.5 Drainage Pan.
    31. 507.6 Added or Converted Equipment or Appliances.
    32. 507.7 Type of Gas(es).
    33. 507.8 Safety Shutoff Devices for Unlisted LP-Gas Appliance Use…
    34. 507.9 Use of Air or Oxygen Under Pressure.
    35. 507.10 Protection of Gas Appliances from Fumes or Gases other …
    36. 507.11 Process Air.
    37. 507.12 Flammable Vapors.
    38. 507.13 Installation in Residential Garages.
    39. 507.14 Installation in Commercial Garages.
    40. 507.15 Installation in Aircraft Hangars.
    41. 507.16 Venting of Flue Gases.
    42. 507.17 Extra Device or Attachment.
    43. 507.18 Addition to Existing System.
    44. 507.19 Avoiding Strain on Gas Piping.
    45. 507.20 Gas Appliance Pressure Regulators.
    46. 507.21 Bleed Lines for Diaphragm-Type Valves.
    47. 508.2 Installation of Appliances on Roofs.
    48. 508.3 Appliances on Roofs.
    49. 507.22 Combination of Appliances and Equipment.
    50. 507.23 Installation Instructions.
    51. 507.24 Protection of Outdoor Appliances.
    52. 507.25 Accessibility for Service.
    53. 507.26 Clearance to Combustible Materials.
    54. 508.1 General.
    55. 508.4 Appliances in Attics and Under-Floor Spaces.
    56. 509.1 Listing.
    57. 509.2 Connection to Venting Systems.
    58. 509.3 Minimum Safe Performance.
    59. 509.4 Type of Venting System to be Used.
    60. 509.5 Masonry, Metal, and Factory-Built Chimneys.
    61. 509.6 Gas Vents.
    62. 509.7 Single-Wall Metal Pipe.
    63. 509.9 Condensation Drain.
    64. 509.10 Vent Connectors for Category I Appliances.
    65. 509.8 Through-the-Wall Vent Termination.
    66. 509.13 Manually Operated Dampers.
    67. 509.14 Automatically Operated Vent Dampers.
    68. 509.15 Obstructions.
    69. 510.1 Additional Requirements to Single Appliance Vent.
    70. 509.11 Vent Connectors for Category II, Category III, and Cate…
    71. 509.12 Appliances Requiring Draft Hoods.
    72. 510.2 Additional Requirements to Multiple-Appliance Vent.
  6. Chapter 6 — WATER SUPPLY AND DISTRIBUTION
  7. Chapter 7 — SANITARY DRAINAGE
  8. Chapter 8 — INDIRECT WASTES
  9. Chapter 9 — VENTS
  10. Chapter 10 — TRAPS AND INTERCEPTORS
  11. Chapter 11 — STORM DRAINAGE
  12. Chapter 12 — FUEL GAS PIPING
  13. Chapter 13 — HEALTH CARE FACILITIES AND MEDICAL GAS AND MEDICA…
  14. Chapter 14 — FIRESTOP PROTECTION
  15. Chapter 15 — ALTERNATE WATER SOURCES FOR NONPOTABLE APPLICATIONS
  16. Chapter 16 — NONPOTABLE RAINWATER CATCHMENT SYSTEMS
  17. Chapter 17 — REFERENCED STANDARDS
  18. Appendix A — RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYS…
  19. Appendix B — EXPLANATORY NOTES ON COMBINATION WASTE AND VENT S…
  20. Appendix C — ALTERNATE PLUMBING SYSTEMS
  21. Appendix D — SIZING STORM WATER DRAINAGE SYSTEMS
  22. Appendix E — MANUFACTURED/MOBILE HOME PARKS AND RECREATIONAL V…
  23. Appendix F — FIREFIGHTER BREATHING AIR REPLENISHMENT SYSTEMS
  24. Appendix G — SIZING OF VENTING SYSTEMS
  25. Appendix H — PRIVATE SEWAGE DISPOSAL SYSTEMS
  26. Appendix I — INSTALLATION STANDARDS
  27. Appendix J — COMBINATION OF INDOOR AND OUTDOOR COMBUSTION AND …
  28. Appendix K — POTABLE RAINWATER CATCHMENT SYSTEMS
  29. Appendix L — SUSTAINABLE PRACTICES
  30. Appendix M — PEAK WATER DEMAND CALCULATOR
  31. Appendix N — IMPACT OF WATER TEMPERATURE ON THE POTENTIAL FOR …
  32. Appendix O — NON-SEWERED SANITATION SYSTEMS
  33. Appendix P — PROFESSIONAL QUALIFICATIONS
  34. Appendix Q — INDOOR HORTICULTURAL FACILITIES
  35. Appendix R — TINY HOUSES
  36. Appendix S — ONSITE STORMWATER TREATMENT SYSTEMS

GoCodebook provides public access, search, citation, multilingual explanation, and practical interpretation of legally adopted building regulations. It is not a substitute for the official ICC or California code publications.