Section 130.2
California Energy Code (Title 24, Part 6) · 2022 edition · updated 2026-09-12 · California
OUTDOOR LIGHTING CONTROLS AND EQUIPMENT
Nonresidential and hotel/motel buildings shall comply with the applicable requirements of Sections 130.2(a) through 130.2(c).
(a) Reserved.
(b) Luminaire shielding requirements. All outdoor luminaires of 6,200 initial luminaire lumens or greater shall comply with backlight, uplight and glare (BUG) in accordance with ANSI/IES TM-15-20, Annex A requirements in accordance with Title 24, Part 11, Section 5.106.8.
Exception 1 to Section 130.2(b): Signs.
Exception 2 to Section 130.2(b): Lighting for building facades, public monuments, public art, statues and vertical surfaces of bridges.
Exception 3 to Section 130.2(b): Lighting not permitted by a health or life safety statute, ordinance or regulation to be a cutoff luminaire.
Exception 4 to Section 130.2(b): Temporary outdoor lighting.
Exception 5 to Section 130.2(b): Replacement of existing pole mounted luminaires in hardscape areas meeting all of the following conditions:
A. Where the existing luminaire does not meet the
luminaire BUG requirements in Section 130.2(b); and
B. Spacing between existing poles is greater than six
times the mounting height of the existing luminaires; and
C. Where no additional poles are being added to the
site; and
D. Where new wiring to the luminaires is not being
installed; and
E. Provided that the connected lighting power wattage
is not increased.
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
NONRESIDENTIAL AND HOTEL/MOTEL OCCUPANCIES—MANDATORY REQUIREMENTS FOR LIGHTING SYSTEMS AND EQUIPMENT, AND ELECTRICAL POWER DISTRIBUTION SYSTEMS
nighttime hours. Signs that are illuminated at night and for more than 1 hour during daylight hours shall be considered ON both day and night.
Exception to Section 130.3(a)2B: Outdoor signs in tunnels and large covered areas that are intended to be illuminated both day and night.
- Demand responsive Electronic Message Center (EMC) control. See Section 110.12 for requirements for demand responsive EMC controls. Note: Authority: Sections 25213, 25218, 25218.5, 25402 and 25402.1, Public Resources Code. Reference: Sections 25007, 25008, 25218.5, 25310, 25402, 25402.1, 25402.4, 25402.5, 25402.8, and 25943, Public Resources Code.