Chapter 15 — ALTERNATE WATER SOURCES FOR NONPOTABLE APPLICATIONS
1501.3 Permit. [BSC-CG, HCD 1 & DWR] It shall be
California Plumbing Code (Title 24, Part 5) · 2025 edition · updated 2026-09-10 · California
Italicized text is a California amendment to the model code, as printed in the official publication.
unlawful for a person to construct, install, alter, or cause to be constructed, installed, or altered an alternate water source system in a building or on its premise s without first obtaining a permit to do such work from the Authority Having Jurisdiction. No changes or connections shall be made to either the alternate water source system or the potable water system within a site containing an alternate water source system without approval by the Authority Having Jurisdiction. Exception: [BSC-CG & HCD 1] A construction permit shall not be required for a clothes washer system meeting the requirements of Section 1503.1.1.
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — California Plumbing Code (Title 24, Part 5)
- Chapter 1 — GENERAL CODE PROVISIONS
- Chapter 2 — DEFINITIONS
- Chapter 3 — GENERAL REGULATIONS
- Chapter 4 — PLUMBING FIXTURES AND FIXTURE FITTINGS
- Chapter 5 — WATER HEATERS
- Chapter 6 — WATER SUPPLY AND DISTRIBUTION
- Chapter 7 — SANITARY DRAINAGE
- Chapter 8 — INDIRECT WASTES
- Chapter 9 — VENTS
- Chapter 10 — TRAPS AND INTERCEPTORS
- Chapter 11 — STORM DRAINAGE
- Chapter 12 — FUEL GAS PIPING
- Chapter 13 — HEALTH CARE FACILITIES AND MEDICAL GAS AND MEDICA…
- Chapter 14 — FIRESTOP PROTECTION
▸Chapter 15 — ALTERNATE WATER SOURCES FOR NONPOTABLE APPLICATIONS
Overview- 1501.1 Applicability. [BSC-CG, DWR & HCD 1] The provisions of …
- 1501.2 System Design. [BSC-CG, HCD 1 & DWR]
- 1501.3 Permit. [BSC-CG, HCD 1 & DWR] It shall be
- 1501.4 Component Identification. System components
- 1501.5 Maintenance and Inspection. [BSC-CG, HCD
- 1505.16 .
- 1501.6 Operation and Maintenance Manual. [BSC-
- 1501.7 Minimum Water Quality Requirements. [BSC-
- 1501.8 Material Compatibility. Alternate water source systems …
- 1501.9 Signage. [BSC-CG, HCD 1, HCD 2 & HCD 1-
- 1501.10 System Controls. Controls for pumps, valves, and
- 1502.1 General. Alternate water source systems shall be
- 1502.2 Supply System Inspection and Test. Alternate
- 1502.3 Cross-Connection Inspection and Testing. An
- 1502.4 Separation Requirements. Underground alternate
- 1502.5 Abandonment. Alternate water source systems that
- 1502.6 Sizing. Unless otherwise provided for in this chapter, …
- 1503.1 General. The provisions of this section shall apply to
- 1503.2 System Requirements. Gray water shall be permitted to b…
- 1503.3 Connections to Potable and Reclaimed (Recy-
- 1503.4 Location. No gray water system or part thereof shall
- 1503.5 Plot Plan Submission. No permit for a gray water
- 1503.6 Prohibited Location. Where there is insufficient
- 1503.7 Drawings and Specifications. The Authority Having Juris…
- 1503.8 Procedure for Estimating Gray Water Dis-
- 1503.9 Gray Water System Components. Gray water
- 1504.1 General. Irrigation or disposal fields shall be permitt…
- 1504.2 Required Area of Subsurface Irrigation
- 1504.3 Determination of Maximum Absorption
- 1504.4 Groundwater Level. No excavation for an irrigation fiel…
- 1504.5 Irrigation, Disposal Field and Mulch Basin
- 1504.6 Reserved.
- 1504.7 Reserved .
- 1504.8 Gray Water System Color and Marking Infor-
- 1504.9 Other Collection and Distribution Systems.
- 1504.10 Testing. Building drains and vents for gray water
- 1504.11 Maintenance. Gray water systems and components shall b…
- 1505.1 General. The provisions of Section 1505.0 through
- 1505.2 Permit. It shall be unlawful for a person to construct,
- 1505.3 System Changes. No changes or connections shall
- 1505.4 Connections to Potable or Recycled Water
- 1505.5 Water Pressure. Reclaimed (recycled) water systems supp…
- 1505.6 Initial Cross-Connection Test. A cross-connection
- 1505.7 Recycled Water Supply System Materials.
- 1505.8 Recycled Water Supply System Color and
- 1505.9 Valves. Valves, except fixture supply control valves,
- 1505.13 Signage . Signs in rooms and water closet tanks in
- 1505.14 Inspection and Testing. Recycled water supply
- 1505.10 Hose Bibbs. Hose bibbs shall not be allowed on
- 1505.11 Required Appurtenances. The recycled water
- 1505.12 Pipe Separation in Trenches . Reclaimed (recycled) wat…
- 1505.15 Minimum Water Quality Requirements for
- 1505.16 Maintenance and Inspection. Recycled water
- 1506.1 General. The provisions of this section shall apply
- 1506.2 Plumbing Plan Submission. No permit for an
- 1506.3 System Changes. No changes or connections shall
- 1506.4 Connections to Potable or Recycled Water
- 1506.5 Water Pressure. On-site treated non-potable gray
- 1506.11 Valves. Valves, except fixture supply control
- 1506.12 Signs. Signs in buildings using on-site treated nonpot…
- 1506.13 Inspection and Testing. On-site treated nonpotable gra…
- 1506.6 Initial Cross-Connection Test. A cross-connection test …
- 1506.7 On-Site Treated Nonpotable Gray Water Sys-
- 1506.8 On-Site Treated Nonpotable Gray Water
- 1506.9 On-Site Treated Nonpotable Gray Water Sys-
- 1506.10 Design and Installation. The design and installation o…
- Chapter 16 — NONPOTABLE RAINWATER CATCHMENT SYSTEMS
- Chapter 17 — REFERENCED STANDARDS
- Appendix A — RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYS…
- Appendix B — EXPLANATORY NOTES ON COMBINATION WASTE AND VENT S…
- Appendix C — ALTERNATE PLUMBING SYSTEMS
- Appendix D — SIZING STORM WATER DRAINAGE SYSTEMS
- Appendix E — MANUFACTURED/MOBILE HOME PARKS AND RECREATIONAL V…
- Appendix F — FIREFIGHTER BREATHING AIR REPLENISHMENT SYSTEMS
- Appendix G — SIZING OF VENTING SYSTEMS
- Appendix H — PRIVATE SEWAGE DISPOSAL SYSTEMS
- Appendix I — INSTALLATION STANDARDS
- Appendix J — COMBINATION OF INDOOR AND OUTDOOR COMBUSTION AND …
- Appendix K — POTABLE RAINWATER CATCHMENT SYSTEMS
- Appendix L — SUSTAINABLE PRACTICES
- Appendix M — PEAK WATER DEMAND CALCULATOR
- Appendix N — IMPACT OF WATER TEMPERATURE ON THE POTENTIAL FOR …
- Appendix O — NON-SEWERED SANITATION SYSTEMS
- Appendix P — PROFESSIONAL QUALIFICATIONS
- Appendix Q — INDOOR HORTICULTURAL FACILITIES
- Appendix R — TINY HOUSES
- Appendix S — ONSITE STORMWATER TREATMENT SYSTEMS