Chapter 6 — DUCT SYSTEMS
California Mechanical Code (Title 24, Part 4) · 2019 edition · updated 2026-09-10 · California
Italicized text is a California amendment to the model code, as printed in the official publication.
Sections in this part
- 601.2 Sizing Requirements. Duct systems shall be sized in
- 602.1 General. 602.0 Material. Materials used for duct systems shall comply
- 602.2 Combustibles Within Ducts or Plenums.
- 602.3 Metal.
- 602.4 Phenolic. Ducts, plenums, or fittings of phenolic shall
- 602.5 Gypsum. Where gypsum products are exposed in ducts
- 602.6 Factory-Made Air Ducts. Factory-made air ducts
- 602.7 Vibration Isolators. Vibration isolation connectors
- 602.8 Corridors. Corridors shall not be used to convey air to
- 603.4 Factory-Made Air Ducts. Factory-made air ducts shall
- 603.1 General.603.0 Installation of Ducts. The pressure classification of ducts shall be
- 603.2 Under Floor or Crawl Space. Air ducts installed
- 603.3 Metal Ducts. Ducts shall be supported at each change
- 603.5 Flexible Air Ducts. Flexible air ducts shall comply
- 603.6 Plastic Ducts. Plastic air ducts and fittings shall be
- 603.7 Protection of Ducts. Ducts installed in locations
- 603.8 Support of Ducts.
- 603.9 Protection Against Flood Damage.
- 603.10 Joints and Seams of Ducts. Joints and seams for
- 603.11 Cross Contamination. Exhaust ducts and venting
- 603.12 Underground Installation.
- 603.13 Air Dispersion Systems.
- 604.0 Insulation of Ducts.604.1 General. Air ducts conveying air at temperatures
- 604.2 [OSHPD 1, 1R, 2, 3 (surgical clinics), 4 & 5] Ther-
- 604.3 [OSHPD 1, 1R, 2, 4 & 5] Thermal or acoustical lining
- 605.1 Smoke Dampers.Dampers. Smoke dampers shall comply with
- 605.2 Fire Dampers. Fire dampers shall comply with UL
- 605.3 Ceiling Radiation Dampers. Ceiling radiation
- 605.4 Multiple Arrangements. Where size requires the
- 605.5 Access and Identification. Fire and smoke dampers
- 605.6 Freedom from Interference. Dampers shall be
- 605.8 When the automatic activation of a smoke damper or a
- 606.1 General. 606.0 Ventilating Ceilings. Perforated ceilings shall be permitted to be
- 606.2 Requirements. Ventilating ceilings shall comply
- 607.1 General.for Dwelling Units. An under-floor space shall be permitted to be
- 607.2 Dwelling Units. The use of under-floor space shall
- 607.3 Enclosed. Such spaces shall be cleaned of all loose
- 607.4 Flammable Materials. The enclosing material of the
- 607.5 Access. Access shall be through an opening in the
- 607.6 Automatic Control. A furnace supplying warm air
- 607.7 Temperature Limit. A furnace supplying warm air to
- 607.8 Noncombustible Receptacle. A noncombustible
- 607.9 Floor Registers. Floor registers shall be designed for
- 607.10 Exterior Wall and Interior Stud Partitions.
- 607.11 Wall Register. Each wall register shall be connected
- 607.12 Distance from Combustible. A duct complying
- 607.13 Vapor Barrier. The entire ground surface of the
- 607.14 Prohibited. Fuel gas lines and plumbing waste
- 608.1 Air-Moving Systems and Smoke Detectors.
(Matrix Adoption Tables are non-regulatory, intended only as an aid to the code user. See Chapter 1 for state agency authority and building applications.)
| Adopting Agency | BSC | BSC- CG |
SFM | HCD | DSA | OSHPD | BSCC | DPH | AGR | DWR | CEC | CA | SL | SLC | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Adopting Agency |
**BSC ** |
BSC- CG |
SFM | 1 | 2 | 1-AC | **AC ** | SS | SS/CC | 1 | 1R | 2 | 3 | 4 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 |
amended (amended sections listed below) |
X | **X ** | X | X | X | **X ** | **X ** | **X ** | **X ** | **X ** | X | ||||||||||||
that are listed below |
|||||||||||||||||||||||
The Office of the State Fire Marshal’s adoption of this chapter or individual sections is applicable to structures regulated by other state agencies pursuant to Section 1.11.0.
2019 CALIFORNIA MECHANICAL CODE 119
120 2019 CALIFORNIA MECHANICAL CODE
CHAPTER 6
DUCT SYSTEMS
601.0 General.601.1 Applicability. Ducts and plenums that are portions of¶
a heating, cooling, ventilation, or exhaust system shall comply with the requirements of this chapter.
605.0 Smoke Dampers, Fire Dampers, and Ceiling¶
607.0 Use of Under-Floor Space as Supply Plenum¶
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — California Mechanical Code (Title 24, Part 4)
- Chapter 1 — GENERAL CODE PROVISIONS
- Chapter 2 — DEFINITIONS
- Chapter 3 — GENERAL REGULATIONS
- Chapter 4 — VENTILATION AIR
- Chapter 5 — EXHAUST SYSTEMS
▸Chapter 6 — DUCT SYSTEMS
Overview- 601.2 Sizing Requirements. Duct systems shall be sized in
- 602.1 General. 602.0 Material. Materials used for duct systems…
- 602.2 Combustibles Within Ducts or Plenums. Materials exposed …
- 602.3 Metal. Ducts, plenums, or fittings of metal shall comply…
- 602.4 Phenolic. Ducts, plenums, or fittings of phenolic shall
- 602.5 Gypsum. Where gypsum products are exposed in ducts
- 602.6 Factory-Made Air Ducts. Factory-made air ducts
- 602.7 Vibration Isolators. Vibration isolation connectors
- 602.8 Corridors. Corridors shall not be used to convey air to
- 603.4 Factory-Made Air Ducts. Factory-made air ducts shall
- 603.1 General.603.0 Installation of Ducts. The pressure classi…
- 603.2 Under Floor or Crawl Space. Air ducts installed
- 603.3 Metal Ducts. Ducts shall be supported at each change
- 603.5 Flexible Air Ducts. Flexible air ducts shall comply
- 603.6 Plastic Ducts. Plastic air ducts and fittings shall be
- 603.7 Protection of Ducts. Ducts installed in locations
- 603.8 Support of Ducts. Installers shall provide the manufactu…
- 603.9 Protection Against Flood Damage. In flood hazard areas, …
- 603.10 Joints and Seams of Ducts. Joints and seams for
- 603.11 Cross Contamination. Exhaust ducts and venting
- 603.12 Underground Installation. Ducts installed underground s…
- 603.13 Air Dispersion Systems. Where installed, air dispersion…
- 604.0 Insulation of Ducts.604.1 General. Air ducts conveying a…
- 604.2 [OSHPD 1, 1R, 2, 3 (surgical clinics), 4 & 5] Ther-
- 604.3 [OSHPD 1, 1R, 2, 4 & 5] Thermal or acoustical lining
- 605.1 Smoke Dampers.Dampers. Smoke dampers shall comply with
- 605.2 Fire Dampers. Fire dampers shall comply with UL
- 605.3 Ceiling Radiation Dampers. Ceiling radiation
- 605.4 Multiple Arrangements. Where size requires the
- 605.5 Access and Identification. Fire and smoke dampers
- 605.6 Freedom from Interference. Dampers shall be
- 605.8 When the automatic activation of a smoke damper or a
- 606.1 General. 606.0 Ventilating Ceilings. Perforated ceilings…
- 606.2 Requirements. Ventilating ceilings shall comply
- 607.1 General.for Dwelling Units. An under-floor space shall b…
- 607.2 Dwelling Units. The use of under-floor space shall
- 607.3 Enclosed. Such spaces shall be cleaned of all loose
- 607.4 Flammable Materials. The enclosing material of the
- 607.5 Access. Access shall be through an opening in the
- 607.6 Automatic Control. A furnace supplying warm air
- 607.7 Temperature Limit. A furnace supplying warm air to
- 607.8 Noncombustible Receptacle. A noncombustible
- 607.9 Floor Registers. Floor registers shall be designed for
- 607.10 Exterior Wall and Interior Stud Partitions. Exterior wa…
- 607.11 Wall Register. Each wall register shall be connected
- 607.12 Distance from Combustible. A duct complying
- 607.13 Vapor Barrier. The entire ground surface of the
- 607.14 Prohibited. Fuel gas lines and plumbing waste
- 608.1 Air-Moving Systems and Smoke Detectors. 608.0 Automatic …
- Chapter 7 — COMBUSTION AIR
- Chapter 8 — CHIMNEYS AND VENTS
- Chapter 9 — INSTALLATION OF SPECIFIC APPLIANCES
- Chapter 10 — BOILERS AND PRESSURE VESSELS
- Chapter 11 — REFRIGERATION
- Chapter 12 — HYDRONICS
- Chapter 13 — FUEL GAS PIPING
- Chapter 14 — PROCESS PIPING
- Chapter 15 — SOLAR ENERGY SYSTEMS
- Chapter 16 — STATIONARY POWER PLANTS
- Chapter 17 — REFERENCED STANDARDS
- Appendix A — RESIDENTIAL PLAN EXAMINER REVIEW FORM FOR HVAC SY…
- Appendix B — PROCEDURES TO BE FOLLOWED TO PLACE GAS EQUIPMENT …
- Appendix C — INSTALLATION AND TESTING OF OIL (LIQUID) FUEL-FIR…
- Appendix D — FUEL SUPPLY: MANUFACTURED/MOBILE HOME PARKS AND R…
- Appendix E — SUSTAINABLE PRACTICES
- Appendix F — SIZING OF VENTING SYSTEMS AND OUTDOOR COMBUSTION …
- Appendix G — EXAMPLE CALCULATION OF OUTDOOR AIR RATE