Vista Municipal Code § 504.3 Protection of enclosed eaves. The exposed underside of enclosed roof
Vista Municipal Code · 2026-09 edition · updated 2026-10-02 · Vista
Cite as: Vista Municipal Code § 504.3 · Text as of 2026-10-02
eaves and soffits shall be protected on the exposed underside by one or more of the following: 1. Noncombustible materials. 2. 2-inch ( 51 mm) nominal dimension lumber when tongue and grooved. 3. Materials approved for not less than 1-hour fire resistance- rated construction on the exterior side, as tested in accordance with ASTM E119 or UL263. Facias are required and shall be ignition- resistant building materials, fire-retardant- treated wood labeled for exterior use and complying with Section 2303.2 of the California Building Code, materials approved for not less than 1-hour fire-resistance- rated construction, or 3-inch ( 51 mm) nominal dimension lumber.
16.42(9) ( Vista 10/24/2025)
Vista Municipal Code
Section 504.3.1 of the California WUI Code is revised to read:
Sec. 504.3.1 Protection of open eaves. The exposed roof deck on the underside of¶
unenclosed roof eaves shall consist of one or more of the following: 1. Noncombustible material. 2. 2-inch ( 51 mm) nominal dimension lumber when tongue and grooved. 3. Materials approved for not less than 1-hour fire-resistance- rated construction on the exterior side, as tested in accordance with ASTM E119 or UL 263. 4. The exterior portion of a 1-hour fire-resistance- rated exterior assembly, as tested in accordance with ASTM E119 or UL 263, applied to the underside of the roof deck designed for exterior fire exposure, including assemblies using the gypsum panel and sheathing products listed in the Gypsum Association Fire Resistance Design Manual. Facias, if provided, shall be of fire-retardant- treated wood labeled for exterior use and complying with Section 2303.2 of the California Building Code, ignition- resistant building materials, materials approved for not less than 1-hour fire-resistance- rated construction, or 3-inch 51 mm) nominal dimension lumber.
Section 504.4 of the California WUI code is revised to read: