Title 17 — BUILDING AND CONSTRUCTION
Petaluma Municipal Code Ch. 3 Building Planning
Petaluma Municipal Code · 2026-09 edition · updated 2026-10-04 · Petaluma
Cite as: Petaluma Municipal Code Chapter 3 · Text as of 2026-10-04
Section R301.2 is amended by inserting the following Table R301.2(1).
Table R301.2(1). CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
0 GROUND SNOW LOADo
WIND DESIGN
(mph)d 110
Topographick NO
NO Special windl
Windbornem N/A
D2 or E
SEISMIC DESIGN CATEGORYf Reference Table R301.2.2.1.1
See mapping tools: www.seismicmaps.org
SUBJECT TO DAMAGE FROM
Weatheringa Negligible
12 inches Frost line depthb
Termitec Yes
32 degrees F WINTER DESIGN TEMPe
ICE BARRIER UNDERLAYMENT NO
REQUIREDh
Initial NFIP Map Date: March 8, 1974.
Initial FIRM date: February 15, 1980.
Current Flood Insurance Study dated: February
19, 2014.
FLOOD HAZARDSg
Panels 982, 1001, 1002, 1003, and 1004 are dated
October 2, 2015.
Panels 891, 893, 894, and 913 are dated February
19, 2014.
1 degree F AIR FREEZING INDEXi
58 degrees F MEAN ANNUAL TEMPj
MANUAL J DESIGN CRITERIAn
Altitude Indoor Design Heating
Winter Summer
Elevation Latitude correction design temperature temperature
heating cooling
factor temperature cooling diMerence
87 FT 38 29 90 N/A 68 degrees F. 75 degrees F. 39 degrees F.
degrees degrees degrees
North. F. F.
Cooling Wind Wind Coincident Daily Winter Summer temperature velocity velocity — wet bulb range humidity humidity diMerence heating cooling
15 degrees F. N/A N/A 67 degrees High. 31 N/A N/A —
F. degrees
F.
For SI: 1 pound per square foot = 0.0479 kPa, 1 mile per hour = 0.447 m/s.
a Where weathering requires a higher strength concrete or grade of masonry than necessary to
satisfy the structural requirements of this code, the frost line depth strength required for
weathering shall govern.
The weathering column shall be Zlled in with the weathering index, “negligible,” “moderate” or
“severe” for concrete as determined from Figure R301.2(4). The grade of masonry units shall be
determined from ASTM C34, C55, C62, C73, C90, C129, C145, C216 or C652.
b Where the frost line depth requires deeper footings than indicated in Figure R403.1(1), the frost
line depth strength required for weathering shall govern. The jurisdiction shall Zll in the frost line
depth column with the minimum depth of footing below Znish grade.
c The jurisdiction shall Zll in this part of the table to indicate the need for protection depending
on whether there has been a history of local subterranean termite damage.
d The jurisdiction shall Zll in this part of the table with the wind speed from the basic wind speed
map [Figure R301.2(5)A]. Wind exposure category shall be determined on a site-speciZc basis in
accordance with Section R301.2.1.4.
e The outdoor design dry-bulb temperature shall be selected from the columns of 97-1/2
-percent values for winter from Appendix D of the International Plumbing Code. Deviations from
the Appendix D temperatures shall be permitted to re[ect local climates or local weather
experience as determined by the building o\cial. [Also see Figure R301.2(1).]
f The jurisdiction shall Zll in this part of the table with the seismic design category determined
from Section R301.2.2.1.
g The jurisdiction shall Zll in this part of the table with (a) the date of the jurisdiction’s entry into
the National Flood Insurance Program (date of adoption of the Zrst code or ordinance for
management of [ood hazard areas), (b) the date(s) of the Flood Insurance Study and (c) the panel
numbers and dates of the currently e]ective FIRMs and FBFMs or other [ood hazard map
adopted by the authority having jurisdiction, as amended.
h In accordance with Sections R905.1.2, R905.4.3.1, R905.5.3.1, R905.6.3.1, R905.7.3.1 and
R905.8.3.1, where there has been a history of local damage from the e]ects of ice damming, the
jurisdiction shall Zll in this part of the table with “YES.” Otherwise, the jurisdiction shall Zll in this
part of the table with “NO.”
i The jurisdiction shall Zll in this part of the table with the 100-year return period air freezing
index (BF-days) from Figure R403.3(2) or from the 100-year (99 percent) value on the National
Climatic Data Center data table “Air Freezing Index-USA Method (Base 32°F).”
j The jurisdiction shall Zll in this part of the table with the mean annual temperature from the
National Climatic Data Center data table “Air Freezing Index-USA Method (Base 32°F).”
k In accordance with Section R301.2.1.5, where there is local historical data documenting
structural damage to buildings due to topographic wind speed-up e]ects, the jurisdiction shall Zll
in this part of the table with “YES.” Otherwise, the jurisdiction shall indicate “NO” in this part of the
table.
l In accordance with Figure R301.2(5)A, where there is local historical data documenting unusual
wind conditions, the jurisdiction shall Zll in this part of the table with “YES” and identify any
speciZc requirements. Otherwise, the jurisdiction shall indicate “NO” in this part of the table.
m In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris
wind zone(s). Otherwise, the jurisdiction shall indicate “NO” in this part of the table.
n The jurisdiction shall Zll in these sections of the table to establish the design criteria using Table
1a or 1b from ACCA Manual J or established criteria determined by the jurisdiction.
o The jurisdiction shall Zll in this section of the table using the Ground Snow Loads in Figure
R301.2(6).
Section R309.1 is amended, with the exceptions replaced as follows:
R309.1 Townhouse automatic Kre sprinkler systems. An automatic residential Zre sprinkler system
shall be installed in townhouses.
Exceptions:
- Accessory Dwelling Unit, provided that all of the following are met:
1.1 The unit meets the deZnition of an Accessory Dwelling Unit as deZned in Government…¶
1.2 The existing primary residence does not have automatic Zre sprinklers.¶
1.4 The unit is on the same lot as the primary residence.¶
1.5 The accessory dwelling unit meets the requirements of California Fire Code,…¶
507.5.1.
- Detached accessory structures to Group R-3 not classiZed as a dwelling unit and not exceeding 1,000
square feet in gross [oor area located at least 50 feet from applicable building.
- Detached Group U Occupancies not greater than 1,000 square feet.
Section R309.1.2 is added as follows:
R309.1.2 Substantial Remodel. An automatic Zre sprinkler system shall be provided throughout all
Townhouses that undergo a substantial improvement.
Section R309.2 is amended to read as follows, with the exception deleted:
R309.2 One- and two-family dwellings automatic Kre sprinkler systems. An automatic residential Zre
sprinkler system shall be installed in townhouses. Group R-3 occupancies permitted under this code
shall be provided throughout regardless of square footage with an automatic sprinkler system inclusive
of all mobile homes, manufactured homes.
Exceptions:
- Accessory Dwelling Unit, provided that all of the following are met:
1.1.¶
1.2. The existing primary residence does not have automatic Zre sprinklers.¶
1.3. The accessory detached dwelling unit does not exceed 1,200 square feet in size.¶
1.4. The unit is on the same lot as the primary residence.¶
1.5.¶
The accessory dwelling unit meets the requirements of California Fire Code, Sections 503.1.1 and
507.5.1.
- Detached accessory structures to Group R-3 not classiZed as a dwelling unit and not exceeding 1,000
square feet in gross [oor area located at least 50 feet from applicable building.
- Detached Group U Occupancies not greater than 1,000 square feet.
Section R309.2.2 is added as follows:
R309.2.2 Substantial Remodel. An automatic Zre sprinkler system shall be provided throughout all one-
and two-family dwellings that undergo a substantial improvement.