R340.1 Finish material pollutant control.

Finish materials including adhesives, sealants, caulks, paints and coatings, aerosol paints and coatings, carpet systems, carpet cushion, carpet adhesive, resilient flooring systems and composite wood products shall meet the volatile organic compound (VOC) emission limits in accordance with the California Green Building Standards Code, Chapter 4, Division 4.5.

2. Awnings and canopies shall comply with the requirements of Section 3105 of the California Building Code.

3. Exterior wall architectural trim, embellishments and fascia.

R337.10.3 Where required. No requirements shall apply to accessory buildings or miscellaneous structures when located at least 50 feet from an applicable building. Appli- cable accessory buildings and attached miscellaneous structures, or detached miscellaneous structures that are installed at a distance of less than 3 feet from an applica- ble building, shall comply with this section. When required by the enforcing agency, detached miscellaneous struc- tures that are installed at a distance of more than 3 feet but less than 50 feet from an applicable building shall comply with the requirements of this section.

R337.10.3.1 Accessory building requirements. Appli- cable accessory buildings that are less than 120 square feet in floor area and are located more than 30 feet but less than 50 feet from an applicable building shall be constructed of noncombustible materials or of ignition- resistant materials as described in Section R337.4.2.

R337.10.3.2 Attached miscellaneous structure requirements. Applicable miscellaneous structures that are attached to, or installed at a distance of less than 3 feet from, an applicable building shall be constructed of noncombustible materials or of ignition-resistant materials as described in Section R337.4.2.

R337.10.3.3 Detached miscellaneous structure requirements. When required by the enforcing agency, applicable detached miscellaneous structures that are installed at a distance of more than 3 feet but less than 50 feet from an applicable building shall be con- structed of noncombustible materials or of ignition- resistant materials as described in Section R337.4.3.

Get a plain-English answer with a citation back to this text.

Ask AI about this code
Contents — California Residential Code (Title 24, Part 2.5)

GoCodebook provides public access, search, citation, multilingual explanation, and practical interpretation of legally adopted building regulations. It is not a substitute for the official ICC or California code publications.