Chapter 8 — ROOF-CEILING CONSTRUCTION
California Residential Code (Title 24, Part 2.5) · 2019 edition · updated 2026-09-12 · California
Italicized text is a California amendment to the model code, as printed in the official publication.
Sections in this part
(Matrix Adoption Tables are nonregulatory, intended only as an aid to the code user.
See Chapter 1 for state agency authority and building applications.)
| Adopting agency | BSC | BSC- CG |
SFM | HCD | DSA | OSHPD | BSCC | DPH | AGR | DWR | CEC | CA | SL | SLC | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Adopting agency | **BSC ** | BSC- CG |
SFM | 1 | 2 | 1/AC | AC | SS | SS/ CC |
1 | 1R | 2 | 3 | 4 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 |
| Adopt entire chapter | |||||||||||||||||||||||
| Adopt entire chapter as amended (amended sections listed below) |
X | ||||||||||||||||||||||
| Adopt only those sections that are listed below |
X | ||||||||||||||||||||||
| Chapter / Section | |||||||||||||||||||||||
| R802.1.1 Note | X | ||||||||||||||||||||||
| R802.1.5 - R802.1.5.10 | X | ||||||||||||||||||||||
| R802.10.2 | X | ||||||||||||||||||||||
| R806.2 | X | ||||||||||||||||||||||
| R806.5 | X | ||||||||||||||||||||||
| Table R806.5 | X | ||||||||||||||||||||||
| R807.1 | X |
Copyright © 2019 ICC. ALL RIGHTS RESERVED. Accessed by Kevin Day (kevin.day@dgs.ca.gov), (California Building Standards Commission) Order Number #100735044 on Jul 24, 2019 03:54 PM (PDT) pursuant to License Agreement with ICC. No further reproduction or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.
100735044
442 2019 CALIFORNIA RESIDENTIAL CODE Copyright © 2019 ICC. ALL RIGHTS RESERVED. Accessed by Kevin Day (kevin.day@dgs.ca.gov), (California Building Standards Commission) Order Number #100735044 on Jul 24, 2019 03:54 PM (PDT) pursuant to License Agreement with ICC. No further reproduction or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.
100735044
CHAPTER 8
ROOF-CEILING CONSTRUCTION
User note:
About this chapter: Chapter 8 addresses the design and construction of roof-ceiling systems. This chapter contains two roof-ceiling framing systems: wood framing and cold-formed steel framing. Allowable span tables are provided to simplify the selection of rafter and ceiling joist size for wood roof framing and cold-formed steel framing. Chapter 8 also provides requirements for the application of ceiling finishes, the proper ventilation of concealed spaces in roofs (for example, enclosed attics and rafter spaces), unvented attic assemblies and attic access.
R802.11 Roof tie-down.¶
R802.11.1 Uplift resistance. Roof assemblies shall have uplift resistance in accordance with Sections R802.11.1.1 and R802.11.1.2.
Where the uplift force does not exceed 200 pounds (90.8 kg), rafters and trusses spaced not more than 24 inches (610 mm) on center shall be permitted to be
Copyright © 2019 ICC. ALL RIGHTS RESERVED. Accessed by Kevin Day (kevin.day@dgs.ca.gov), (California Building Standards Commission) Order Number #100735044 on Jul 24, 2019 03:54 PM (PDT) pursuant to License Agreement with ICC. No further reproduction or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.
100735044
ROOF-CEILING CONSTRUCTION
TABLE R802.11 RAFTER OR TRUSS UPLIFT CONNECTION FORCES FROM WIND (ASD) (POUNDS PER CONNECTION) a, b, c, d, e, f, g, h
| RAFTER OR TRUSS SPACING |
ROOF SPAN (feet) |
EXPOSURE B | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| RAFTER OR TRUSS SPACING |
ROOF SPAN (feet) |
Ultimate Design Wind SpeedVULT (mph) | Ultimate Design Wind SpeedVULT (mph) | Ultimate Design Wind SpeedVULT (mph) | Ultimate Design Wind SpeedVULT (mph) | Ultimate Design Wind SpeedVULT (mph) | Ultimate Design Wind SpeedVULT (mph) | Ultimate Design Wind SpeedVULT (mph) | Ultimate Design Wind SpeedVULT (mph) | Ultimate Design Wind SpeedVULT (mph) | Ultimate Design Wind SpeedVULT (mph) |
| RAFTER OR TRUSS SPACING |
ROOF SPAN (feet) |
110 | 110 | 115 | 115 | 120 | 120 | 130 | 130 | 140 | 140 |
| RAFTER OR TRUSS SPACING |
ROOF SPAN (feet) |
Roof Pitch |
Roof Pitch |
Roof Pitch |
Roof Pitch |
Roof Pitch |
Roof Pitch |
Roof Pitch |
Roof Pitch |
Roof Pitch |
Roof Pitch |
| RAFTER OR TRUSS SPACING |
ROOF SPAN (feet) |
< 5:12 | 5:12 | < 5:12 | 5:12 | < 5:12 | 5:12 | < 5:12 | 5:12 | < 5:12 | 5:12 |
| 12 o.c. | 12 | 48 | 43 | 59 | 53 | 70 | 64 | 95 | 88 | 122 | 113 |
| 12 o.c. | 18 | 59 | 52 | 74 | 66 | 89 | 81 | 122 | 112 | 157 | 146 |
| 12 o.c. | 24 | 71 | 62 | 89 | 79 | 108 | 98 | 149 | 137 | 192 | 178 |
| 12 o.c. | 28 | 79 | 69 | 99 | 88 | 121 | 109 | 167 | 153 | 216 | 200 |
| 12 o.c. | 32 | 86 | 75 | 109 | 97 | 134 | 120 | 185 | 170 | 240 | 222 |
| 12 o.c. | 36 | 94 | 82 | 120 | 106 | 146 | 132 | 203 | 186 | 264 | 244 |
| 12 o.c. | 42 | 106 | 92 | 135 | 120 | 166 | 149 | 230 | 211 | 300 | 278 |
| 12 o.c. | 48 | 118 | 102 | 151 | 134 | 185 | 166 | 258 | 236 | 336 | 311 |
| 16 o.c. | 12 | 64 | 57 | 78 | 70 | 93 | 85 | 126 | 117 | 162 | 150 |
| 16 o.c. | 18 | 78 | 69 | 98 | 88 | 118 | 108 | 162 | 149 | 209 | 194 |
| 16 o.c. | 24 | 94 | 82 | 118 | 105 | 144 | 130 | 198 | 182 | 255 | 237 |
| 16 o.c. | 28 | 105 | 92 | 132 | 117 | 161 | 145 | 222 | 203 | 287 | 266 |
| 16 o.c. | 32 | 114 | 100 | 145 | 129 | 178 | 160 | 246 | 226 | 319 | 295 |
| 16 o.c. | 36 | 125 | 109 | 160 | 141 | 194 | 176 | 270 | 247 | 351 | 325 |
| 16 o.c. | 42 | 141 | 122 | 180 | 160 | 221 | 198 | 306 | 281 | 399 | 370 |
| 16 o.c. | 48 | 157 | 136 | 201 | 178 | 246 | 221 | 343 | 314 | 447 | 414 |
| 24 o.c. | 12 | 96 | 86 | 118 | 106 | 140 | 128 | 190 | 176 | 244 | 226 |
| 24 o.c. | 18 | 118 | 104 | 148 | 132 | 178 | 162 | 244 | 224 | 314 | 292 |
| 24 o.c. | 24 | 142 | 124 | 178 | 158 | 216 | 196 | 298 | 274 | 384 | 356 |
| 24 o.c. | 28 | 158 | 138 | 198 | 176 | 242 | 218 | 334 | 306 | 432 | 400 |
| 24 o.c. | 32 | 172 | 150 | 218 | 194 | 268 | 240 | 370 | 340 | 480 | 444 |
| 24 o.c. | 36 | 188 | 164 | 240 | 212 | 292 | 264 | 406 | 372 | 528 | 488 |
| 24 o.c. | 42 | 212 | 184 | 270 | 240 | 332 | 298 | 460 | 422 | 600 | 556 |
| 24 o.c. | 48 | 236 | 204 | 302 | 268 | 370 | 332 | 516 | 472 | 672 | 622 |
(continued)
470 2019 CALIFORNIA RESIDENTIAL CODE
Copyright © 2019 ICC. ALL RIGHTS RESERVED. Accessed by Kevin Day (kevin.day@dgs.ca.gov), (California Building Standards Commission) Order Number #100735044 on Jul 24, 2019 03:54 PM (PDT) pursuant to License Agreement with ICC. No further reproduction or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.
100735044
ROOF-CEILING CONSTRUCTION
TABLE R802.11—continued RAFTER OR TRUSS UPLIFT CONNECTION FORCES FROM WIND (ASD) (POUNDS PER CONNECTION) a, b, c, d, e, f, g, h
| RAFTER OR TRUSS SPACING |
ROOF SPAN (feet) |
EXPOSURE C | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| RAFTER OR TRUSS SPACING |
ROOF SPAN (feet) |
Ultimate Design Wind SpeedVULT (mph) | Ultimate Design Wind SpeedVULT (mph) | Ultimate Design Wind SpeedVULT (mph) | Ultimate Design Wind SpeedVULT (mph) | Ultimate Design Wind SpeedVULT (mph) | Ultimate Design Wind SpeedVULT (mph) | Ultimate Design Wind SpeedVULT (mph) | Ultimate Design Wind SpeedVULT (mph) | Ultimate Design Wind SpeedVULT (mph) | Ultimate Design Wind SpeedVULT (mph) |
| RAFTER OR TRUSS SPACING |
ROOF SPAN (feet) |
110 | 110 | 115 | 115 | 120 | 120 | 130 | 130 | 140 | 140 |
| RAFTER OR TRUSS SPACING |
ROOF SPAN (feet) |
Roof Pitch |
Roof Pitch |
Roof Pitch |
Roof Pitch |
Roof Pitch |
Roof Pitch |
Roof Pitch |
Roof Pitch |
Roof Pitch |
Roof Pitch |
| RAFTER OR TRUSS SPACING |
ROOF SPAN (feet) |
< 5:12 | 5:12 | < 5:12 | 5:12 | < 5:12 | 5:12 | < 5:12 | 5:12 | < 5:12 | 5:12 |
| 12 o.c. | 12 | 95 | 88 | 110 | 102 | 126 | 118 | 161 | 151 | 198 | 186 |
| 12 o.c. | 18 | 121 | 111 | 141 | 131 | 163 | 151 | 208 | 195 | 257 | 242 |
| 12 o.c. | 24 | 148 | 136 | 173 | 160 | 200 | 185 | 256 | 239 | 317 | 298 |
| 12 o.c. | 28 | 166 | 152 | 195 | 179 | 225 | 208 | 289 | 269 | 358 | 335 |
| 12 o.c. | 32 | 184 | 168 | 216 | 199 | 249 | 231 | 321 | 299 | 398 | 373 |
| 12 o.c. | 36 | 202 | 185 | 237 | 219 | 274 | 254 | 353 | 329 | 438 | 411 |
| 12 o.c. | 42 | 229 | 210 | 269 | 248 | 312 | 289 | 402 | 375 | 499 | 468 |
| 12 o.c. | 48 | 256 | 234 | 302 | 278 | 349 | 323 | 450 | 420 | 560 | 524 |
| 16 o.c. | 12 | 126 | 117 | 146 | 136 | 168 | 157 | 214 | 201 | 263 | 247 |
| 16 o.c. | 18 | 161 | 148 | 188 | 174 | 217 | 201 | 277 | 259 | 342 | 322 |
| 16 o.c. | 24 | 197 | 181 | 230 | 213 | 266 | 246 | 340 | 318 | 422 | 396 |
| 16 o.c. | 28 | 221 | 202 | 259 | 238 | 299 | 277 | 384 | 358 | 476 | 446 |
| 16 o.c. | 32 | 245 | 223 | 287 | 265 | 331 | 307 | 427 | 398 | 529 | 496 |
| 16 o.c. | 36 | 269 | 246 | 315 | 291 | 364 | 338 | 469 | 438 | 583 | 547 |
| 16 o.c. | 42 | 305 | 279 | 358 | 330 | 415 | 384 | 535 | 499 | 664 | 622 |
| 16 o.c. | 48 | 340 | 311 | 402 | 370 | 464 | 430 | 599 | 559 | 745 | 697 |
| 24 o.c. | 12 | 190 | 176 | 220 | 204 | 252 | 236 | 322 | 302 | 396 | 372 |
| 24 o.c. | 18 | 242 | 222 | 282 | 262 | 326 | 302 | 416 | 390 | 514 | 484 |
| 24 o.c. | 24 | 296 | 272 | 346 | 320 | 400 | 370 | 512 | 478 | 634 | 596 |
| 24 o.c. | 28 | 332 | 304 | 390 | 358 | 450 | 416 | 578 | 538 | 716 | 670 |
| 24 o.c. | 32 | 368 | 336 | 432 | 398 | 498 | 462 | 642 | 598 | 796 | 746 |
| 24 o.c. | 36 | 404 | 370 | 474 | 438 | 548 | 508 | 706 | 658 | 876 | 822 |
| 24 o.c. | 42 | 458 | 420 | 538 | 496 | 624 | 578 | 804 | 750 | 998 | 936 |
| 24 o.c. | 48 | 512 | 468 | 604 | 556 | 698 | 646 | 900 | 840 | 1120 | 1048 |
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 0.447 m/s, 1 pound = 0.454 kg, 1 pound per square foot = 47.9 N/m 2,
1 pound per linear foot = 14.6 N/m. a. The uplift connection forces are based on a maximum 33-foot mean roof height and Wind Exposure Category B or C. For Exposure D, the uplift connection
force shall be selected from the Exposure C portion of the table using the next highest tabulated ultimate design wind speed. The adjustment coefficients in Table R301.2(3) shall not be used to multiply the tabulated forces for Exposures C and D or for other mean roof heights. b. The uplift connection forces include an allowance for roof and ceiling assembly dead load of 15 psf. c. The tabulated uplift connection forces are limited to a maximum roof overhang of 24 inches. d. The tabulated uplift connection forces shall be permitted to be multiplied by 0.75 for connections not located within 8 feet of building corners. e. For buildings with hip roofs with 5:12 and greater pitch, the tabulated uplift connection forces shall be permitted to be multiplied by 0.70. This reduction shall
not be combined with any other reduction in tabulated forces. f. For wall-to-wall and wall-to-foundation connections, the uplift connection force shall be permitted to be reduced by 60 plf for each full wall above. g. Linear interpolation between tabulated roof spans and wind speeds shall be permitted. h. The tabulated forces for a 12-inch on-center spacing shall be permitted to be used to determine the uplift load in pounds per linear foot.
Copyright © 2019 ICC. ALL RIGHTS RESERVED. Accessed by Kevin Day (kevin.day@dgs.ca.gov), (California Building Standards Commission) Order Number #100735044 on Jul 24, 2019 03:54 PM (PDT) pursuant to License Agreement with ICC. No further reproduction or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.
100735044
ROOF-CEILING CONSTRUCTION
R803.2.1.1 Exposure durability. Wood structural panels, when designed to be permanently exposed in outdoor applications, shall be of an exterior exposure durability. Wood structural panel roof sheathing exposed to the underside shall be permitted to be of interior type bonded with exterior glue, identified as Exposure 1.
R803.2.1.2 Fire-retardant-treated plywood. The allowable unit stresses for fire-retardant-treated plywood, including fastener values, shall be developed from an approved method of investigation that considers the effects of anticipated temperature and humidity to which the fire-retardant-treated plywood will be subjected, the type of treatment and redrying process. The fire-retardant-treated plywood shall be graded by an approved agency.
R803.2.2 Allowable spans. The maximum allowable spans for wood structural panel roof sheathing shall not exceed the values set forth in Table R503.2.1.1(1), or APA E30.
R803.2.3 Installation. Wood structural panel used as roof sheathing shall be installed with joints staggered or not staggered in accordance with Table R602.3(1), APA E30 for wood roof framing or with Table R804.3 for coldformed steel roof framing. Wood structural panel roof sheathing in accordance with Table R503.2.1.1(1) shall not cantilever more than 9 inches (229 mm) beyond the gable endwall unless supported by gable overhang framing.
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — California Residential Code (Title 24, Part 2.5)
- Chapter 2 — DEFINITIONS AND ABBREVIATIONS
- Chapter 1 — SCOPE AND APPLICATION
- Chapter 3 — BUILDING PLANNING
- Chapter 4 — FOUNDATIONS
- Chapter 5 — FLOORS
- Chapter 6 — WALL CONSTRUCTION
- Chapter 7 — WALL COVERING
▸Chapter 8 — ROOF-CEILING CONSTRUCTION
- Chapter 9 — ROOF ASSEMBLIES
- Chapter 10 — CHIMNEYS AND FIREPLACES
- Chapter 44 — REFERENCED STANDARDS
- Appendix F — RADON CONTROL METHODS
- Appendix H — PATIO COVERS
- Appendix I — PRIVATE SEWAGE DISPOSAL
- Appendix J — EXISTING BUILDINGS AND STRUCTURES
- Appendix K — SOUND TRANSMISSION
- Appendix L — PERMIT FEES
- Appendix O — AUTOMATIC VEHICULAR GATES
- Appendix Q — TINY HOUSES
- Appendix R — LIGHT STRAW-CLAY CONSTRUCTION
- Appendix S — STRAWBALE CONSTRUCTION
- Appendix T — SOLAR-READY PROVISIONS—DETACHED ONE- AND
- Appendix V — SWIMMING POOL SAFETY ACT
- Appendix W — AREAS PROTECTED BY THE FACILITIES
- Appendix X — EMERGENCY HOUSING