435.1 Scope .

435.1 Scope . The provisions of this section shall apply to 24-hour care facilities in a Group R-2.1, R-3.1 or R-4 occupancy licensed by a governmental agency.

435.2 General.

435.2 General. The provisions in this section shall apply in addition to general requirements in this code. 435.2.1 Restraint shall not be practiced in a Group R-2.1, R-3.1 or R-4 occupancies. Exception: Occupancies which meet all the requirements for a Group I-3 occupancy. 435.2.2 Pursuant to Health and Safety Code, Section 13133, regulations of the state fire marshal pertaining to occupancies classified as Residential Facilities (RF) and Residential-care Facilities for the Elderly (RCFE) shall apply uniformly throughout the state and no city, county, city and county, including a charter…

435.3 Building height and area provisions.

435.3 Building height and area provisions. 435.3.1 Group R-2.1, R-3.1 and R-4 shall be constructed in accordance with Table 504.3 of the California Building Code. [California Code of Regulations, Title 19, Division 1, §3.26] Operators Statement – Group I, R-2.1, R-3.1 and R-4 Occupancies. Every person, firm or corporation maintaining or operating any Group I or R-2.1, R-3.1 or R-4 occupancy shall provide an operators statement in accordance with Section 13132 of the Health and Safety Code which reads as follows: “ 13132. Every person, firm or corporation maintaining or operating any facility…

435.4 Type of construction provisions.

435.4 Type of construction provisions. 435.4.1 Group R-2.1, occupancies are not permitted in non-fire-resistance-rated construction, see Health and Safety Code, Section 13131.5. on Jul 18, 2025 11:14 AM (CDT) THEREUNDER. APPENDIX CHAPTER 4—SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY

435.5 Fire-resistance-rated construction provisions.

435.5 Fire-resistance-rated construction provisions. 435.5.1 Smoke barriers required. Group R-2.1 and R-4 occupancies licensed as a Residential Care Facility (RCF) with individual floor areas over 6000 square feet (557 m [2] ) per floor, shall be provided with smoke barriers, constructed in accordance with Section 710 of the California Building Code. Group R-2.1 occupancies housing bedridden clients shall be provided with smoke barriers constructed in accordance with Section 710 of the California Building Code regardless of the number of clients. When smoke barriers are required, the area…

435.6 Interior finish provisions.

435.6 Interior finish provisions. 435.6.1 Interior wall and ceiling finish. Group R-3.1 occupancies housing a bedridden client shall comply with Interior Wall and Ceil- ing Finish requirements specified for Group I-2 occupancies in Table 903.3 of the California Building Code. 435.6.2 Safety padding. Padding material used on walls, floors and ceilings in Group I and R-2.1 occupancies shall be of an approved type tested in accordance with the procedures established by State Fire Marshal Standard 12-8-100, Room Fire Test for Wall and Ceil- ing Materials, California Code of Regulations, Title 24,…

435.7 Fire Protection system provisions.

435.7 Fire Protection system provisions. 435.7.1 Automatic sprinkler systems in Group R-2.1, R-3.1 and R-4 occupancies. An automatic sprinkler system shall be installed where required in Section 903. 435.7.2 Fire alarm systems in Group R-2.1 and R-4 occupancies. An approved fire alarm system shall be installed where required in Section 907. 435.7.3 Smoke alarms in Groups R-2.1, R-3.1 and R-4 occupancies. Smoke alarms shall be installed where required in Section 907.2.11.2. 435.7.4 Hearing impaired. See Section 907.5.2.3.5.

435.8 Means of egress provisions.

435.8 Means of egress provisions. 435.8.1 General. In addition to the general means of egress requirements of Chapter 10, this section shall apply to Group R-2.1, R-3.1 and R-4 occupancies. 435.8.2 Number of exits. 435.8.2.1 Group R-2.1, R-3.1 and R-4 occupancies shall have a minimum of two exits. Exception. Ancillary use areas or occupancies shall have egress as required by Section 1021. 435.8.3 Egress arrangements. 435.8.3.1 Egress through adjoining dwelling units shall not be permitted. 435.8.3.2 Group R-3.1 occupancies housing nonambulatory clients. In a Group R-3.1 occupancy, bedrooms…

435.9 Request for alternate means of protection for facilities housing bedridden clients .

435.9 Request for alternate means of protection for facilities housing bedridden clients . Request for alternate means of protection shall apply to Sections 435 through 435.9. Request for approval to use an alternative material, assembly or materials, equipment, method of construction, method of installation of equipment or means of protection shall be made in writing to the local fire enforcing agency by the facility, client or the client’s authorized representative. Sufficient evidence shall be submitted to substantiate the need for an alternate means of protection. The facility, client or…

435.10 Temporarily bedridden clients.

435.10 Temporarily bedridden clients. Clients who become temporarily bedridden as defined in Health and Safety Code, Section 1569.72, as enforced by the Department of Social Services, may continue to be housed on any story in Group R-2.1, R-3.1 or R-4 occupan- cies classified as Residential Care Facilities for the Elderly (RCFE). Every Residential Care Facility for the Elderly (RCFE) admitting or retaining a bedridden resident shall, within 48 hours of the resident’s admission or retention in the facility, notify the local fire authority with jurisdiction of the estimated length of time the…