Chapter 3 — PROVISIONS FOR ALL COMPLIANCE METHODS
Section 323 — [DSA-SS, DSA-SS/CC]
California Existing Building Code (Title 24, Part 10) · 2022 edition · updated 2026-09-10 · California
Italicized text is a California amendment to the model code, as printed in the official publication.
ADDITIONAL REQUIREMENTS FOR PUBLIC
SCHOOLS AND COMMUNITY COLLEGES The requirements of Section 323 apply only to public schools under the jurisdiction of the Division of the State Architect- Structural Safety (DSA-SS, refer to Section 1.9.2.1) and com- munity colleges under the jurisdiction of the Division of the State Architect—Structural Safety/Community Colleges (DSA-SS/CC, refer to Section 1.9.2.2).
323.1 Evaluation and design criteria report. During the¶
schematic phase of the project, the owner or the registered design professional in charge of the design shall prepare and sign an Evaluation and Design Criteria Report in accordance with Sections 4-306 and 4-307(a) of the California Adminis- trative Code. The report shall be submitted to the DSA for review and approval prior to proceeding with design devel- opment of the rehabilitation.
The Evaluation and Design Criteria Report shall:
1. Identify the building(s) structural and nonstructural systems, potential deficiencies in the elements or systems and the proposed method for retrofit.
2. Identify geological and site-related hazards.
3. Propose the methodology for evaluation and retrofit design.
4. Propose the complete program for data collection (Section 319.2).
5. Include existing or “as-built” building plans, reports and associated documents of the existing construction.
323.2 Rehabilitation involving only portions of structures.¶
Where only a portion(s) of a structure is to be rehabilitated, the public school or community college portion of the struc- ture shall:
1. Be seismically separated from the unrehabilitated por- tion in accordance with Chapter 16 of the California Building Code, or the entire structure shall be rehabili- tated in accordance with this section. For structures in which the unrehabilitated portion is above or below the
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
3-26 2022 CALIFORNIA EXISTING BUILDING CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
CALIFORNIA EXISTING BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 3 A – PROVISIONS FOR ALL COMPLIANCE METHODS [OSHPD 1] (Matrix Adoption Tables are nonregulatory, intended only as an aid to the code user.
See Chapter 1 for state agency authority and building applications.)
| Adopting Agency | BSC | BSC- CG |
SFM | HCD | DSA | OSHPD | BSCC | DPH | AGR | DWR | CEC | CA | SL | SLC | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Adopting Agency | BSC | BSC- CG |
SFM | 1 | 2 | **1/AC ** | AC | SS | SS/CC | 1 | 1R | 2 | 3 | 4 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 |
| Adopt Entire Chapter | X | ||||||||||||||||||||||
| Adopt Entire Chapter as amended (amended sections listed below) |
|||||||||||||||||||||||
| Adopt only those sections that are listed below |
|||||||||||||||||||||||
| Chapter / Section | |||||||||||||||||||||||
The state agency does not adopt sections identified with the following symbol: The Office of the State Fire Marshal’s adoption of this chapter or individual sections is applicable to structures regulated by other state agencies pursuant to Section 1.11.
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
3A-2 2022 CALIFORNIA EXISTING BUILDING CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
CHAPTER 3 A
PROVISIONS FOR ALL COMPLIANCE METHODS
User note:
About this chapter: Chapter 3 explains the three compliance options for alterations and additions available in the code. In addition, this chapter also lays out the methods to be used for seismic design and evaluation throughout this code. Finally, this chapter clarifies that provi- sions in other I-Codes related to repairs, alterations, additions, relocation and changes of occupancy must also be addressed unless they conflict with this code. In that case, this code takes precedence.
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — California Existing Building Code (Title 24, Part 10)
- Chapter 2 — DEFINITIONS
- Appendix A — GUIDELINES FOR
- Appendix B — SUPPLEMENTARY
- Appendix C — GUIDELINES FOR THE WIND
- Appendix D — BOARD OF
- Chapter 1 — SCOPE AND ADMINISTRATION
▸Chapter 3 — PROVISIONS FOR ALL COMPLIANCE METHODS
Overview- Section 301
- Section 302
- Section 304
- Section 303
- Section 305
- Section 306
- Section 309
- Section 310 — [OSHPD 1R, 2 and 5]
- Section 311 — [OSHPD 1R, 2 and 5]
- Section 307
- Section 308
- Section 312 — [OSHPD 1R]
- Section 313 — [SFM]
- Section 314 — [SFM]
- Section 315 — [SFM]
- Section 316 — [SFM]
- Section 317
- Section 319
- Section 318
- Section 320
- Section 321
- Section 322
- Section 323 — [DSA-SS, DSA-SS/CC]
- Section 301A
- Section 302A
- Section 303A
- Section 304A
- Section 305A
- Section 306A
- Section 307A — 309 A
- Section 310A
- Section 311A
- Section 312A
- Section 313A
- Chapter 4 — REPAIRS
- Chapter 5 — PRESCRIPTIVE COMPLIANCE METHOD
- Chapter 6 — CLASSIFICATION OF WORK
- Chapter 7 — ALTERATIONS—LEVEL 1
- Chapter 8 — ALTERATIONS—LEVEL 2
- Chapter 9 — ALTERATIONS—LEVEL 3
- Chapter 10 — CHANGE OF OCCUPANCY
- Chapter 11 — ADDITIONS
- Chapter 12 — HISTORIC BUILDINGS
- Chapter 13 — PERFORMANCE COMPLIANCE METHODS
- Chapter 14 — RELOCATED OR MOVED BUILDINGS
- Chapter 15 — CONSTRUCTION SAFEGUARDS
- Chapter 16 — REFERENCED STANDARDS