Skip to content

Chapter 3 — PROVISIONS FOR ALL COMPLIANCE METHODS

Section 302A

California Existing Building Code (Title 24, Part 10) · 2022 edition · updated 2026-09-10 · California

Italicized text is a California amendment to the model code, as printed in the official publication.

GENERAL PROVISIONS 302 A .1 Dangerous conditions. The code official shall have the authority to require the elimination of conditions deemed dangerous. 302 A .2 Additional codes. Alterations, repairs, additions and changes of occupancy to, or relocation of, existing build- ings and structures shall comply with the provisions for alter- ations, repairs, additions and changes of occupancy or relocation, respectively, in the California Fire Code, Califor- nia Mechanical Code, California Plumbing Code and Cali- fornia Electrical Code. Where provisions of the other codes conflict with provisions of this chapter, the provisions of this chapter shall take precedence.

Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.

PROVISIONS FOR ALL COMPLIANCE METHODS

302 A .2.1 Additional codes in health care. In existing Group I-2 occupancies, ambulatory health care facilities, outpatient clinics and hyperbaric facilities, alterations, repairs, additions and changes of occupancy to, or relocation of, existing buildings and structures shall also comply with NFPA 99. 302 A .3 Existing materials and equipment . Materials and equipment already in use in a building in compliance with requirements or approvals in effect at the time of their erection or installation shall be permitted to remain in use unless determined by the code official to be unsafe in accordance with California Building Code Section 116 .

302A.3.1 Existing seismic force-resisting systems. Where the existing seismic force-resisting system is a type that can be designated ordinary or is a welded steel moment frame constructed under a permit issued prior to October 25, 1994, values of R, Ω 0 and Cd for the existing seismic force-resisting system shall be those specified by this code for an ordinary system unless it is demonstrated that the existing system will provide performance equivalent to that of a detailed, intermediate or special system. 302 A .4 New and replacement materials. Except as otherwise required or permitted by this code, materials and equipment permitted by the applicable code for new construction shall be used. Like materials shall be permitted for repairs and alterations, provided no hazard to life, health or property is created. Hazardous materials shall not be used where the code for new construction would not permit their use in buildings of similar occupancy, purpose and location.

[BS] 302 A .4.1 New structural members and connec- tions. New structural members and connections shall comply with the detailing provisions of the California Building Code for new buildings of similar structure, purpose and location.

Exception: Where alternative design criteria are specifically permitted. 302 A .5 Occupancy and use. Where determining the appropriate application of the referenced sections of this code, the occupancy and use of a building shall be determined in accordance with Chapter 3 of the California Building Code .

302A.6 Maintenance. Buildings and structures, and parts

thereof, shall be maintained in a safe and sanitary condition. Devices or safeguards which are required by this code shall be maintained in conformance with the code edition under which they were installed. The owner or the owner’s desig- nated agent shall be responsible for the maintenance of buildings and structures. To determine compliance with this subsection, the building official shall have the authority to require a building or structure to be re-inspected. The requirements of this chapter shall not provide the basis for removal or abrogation of fire protection and safety systems and devices in existing structures.

302A.7 Construction documents for retrofit or rehabilita-

tion. The design loads and other information pertinent to the structural design required by California Building Code Sec- tion 1603A shall be included in the drawings. In addition to the information required by California Building Code Section 1603A.1.5, the drawings shall show the ground motion haz-

ard used for the retrofit or rehabilitation as either a percent- age of the California Building Code prescribed ground motion for new hospital buildings, or ASCE 41 seismic haz- ard designation, or a probability of exceedance in a specified time period, or a return period for exceedance of the speci- fied ground motion.

Get a plain-English answer with a citation back to this text.

Ask AI about this code
Contents — California Existing Building Code (Title 24, Part 10)

GoCodebook provides public access, search, citation, multilingual explanation, and practical interpretation of legally adopted building regulations. It is not a substitute for the official ICC or California code publications.