Chapter 3 — PROVISIONS FOR ALL COMPLIANCE METHODS
Section 303
California Existing Building Code (Title 24, Part 10) · 2022 edition · updated 2026-09-10 · California
Italicized text is a California amendment to the model code, as printed in the official publication.
303.1 Storm shelters.¶
This section applies to the construction of storm shelters constructed as rooms or spaces within existing buildings for the purpose of providing protection during storms that produce high winds, such as tornados and hurricanes. Such structures shall be designated to be hurricane shelters, tornado shelters, or combined hurricane and tornado shelters. Such structures shall be constructed in accordance with this code and ICC 500.
303.2 Addition to a Group E occupancy. Where an addition¶
is added to an existing Group E occupancy located in an area where the shelter design wind speed for tornados is 250 mph (402.3 km/h) in accordance with Figure 304.2(1) of ICC 500 and the occupant load in the addition is 50 or more, the addition shall have a storm shelter constructed in accordance with ICC 500.
Exceptions:
Group E day care facilities.
Group E occupancies accessory to places of religious worship.
Additions meeting the requirements for shelter design in ICC 500.
303.2.1 Required occupant capacity. The required occupant capacity of the storm shelter shall include all buildings on the site, and shall be the total occupant load
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
PROVISIONS FOR ALL COMPLIANCE METHODS
the structural system will provide performance equivalent to that of a “Detailed,” “Intermediate” or “Special” system.
- ASCE 41, using a Tier 3 procedure and the twolevel performance objective in Table 304.3.1 for the applicable risk category.
[BS] TABLE 304.3.1 PERFORMANCE OBJECTIVES FOR USE IN ASCE 41
FOR COMPLIANCE WITH FULL SEISMIC FORCES
- ASCE 41, using the performance objective in Table 304.3.2 for the applicable risk category.
[BS] TABLE 304.3.2 PERFORMANCE OBJECTIVES FOR USE IN ASCE 41 FOR COMPLIANCE WITH REDUCED SEISMIC FORCES
| RISK CATEGORY (Based on IBC Table 1604.5) |
STRUCTURAL PERFORMANCE LEVEL FOR USE WITH BSE-1N EARTHQUAKE HAZARD LEVEL |
STRUCTURAL PERFORMANCE LEVEL FOR USE WITH BSE-2N EARTHQUAKE HAZARD LEVEL |
|---|---|---|
| I | Life Safety (S-3) | Collapse Prevention (S-5) |
| II | Life Safety (S-3) | Collapse Prevention (S-5) |
| III | Damage Control (S-2) | Limited Safety (S-4) |
| IV | Immediate Occupancy (S-1) |
Life Safety (S-3) |
[BS] 304.3.2 Compliance with reduced seismic forces. Where seismic evaluation and design is permitted to use reduced seismic forces, the criteria used shall be in accordance with one of the following:
The California Building Code using 75 percent of the prescribed forces. Values of R, Ω0 and Cd used for analysis shall be as specified in Section 304.3.1 of this code.
Structures or portions of structures that comply with the requirements of the applicable chapter in Appendix A as specified in Items 2.1 through 2.4 and subject to the limitations of the respective Appendix A chapters shall be deemed to comply with this section.
2.1. The seismic evaluation and design of unreinforced masonry bearing wall buildings in Risk Category I or II are permitted to be based on the procedures specified in Appendix Chapter A1.
2.2. Seismic evaluation and design of the wall anchorage system in reinforced concrete and reinforced masonry wall buildings with flexible diaphragms in Risk Category I or II are permitted to be based on the procedures specified in Chapter A2.
2.3. Seismic evaluation and design of cripple walls and sill plate anchorage in residential buildings of light-frame wood construction in Risk Category I or II are permitted to be based on the procedures specified in Chapter A3.
2.4. Seismic evaluation and design of soft, weak or open-front wall conditions in multipleunit residential buildings of wood construction in Risk Category I or II are permitted to be based on the procedures specified in Chapter A4.
| RISK CATEGORY (Based on IBC Table 1604.5) |
STRUCTURAL PERFORMANCE LEVEL FOR USE WITH BSE-1E EARTHQUAKE HAZARD LEVEL |
STRUCTURAL PERFORMANCE LEVEL FOR USE WITH BSE-2E EARTHQUAKE HAZARD LEVEL |
|---|---|---|
| I | Life Safety (S-3). See Note a |
Collapse Prevention (S- 5) |
| II | Life Safety (S-3). See Note a |
Collapse Prevention (S- 5) |
| III | Damage Control (S-2). See Note a |
Limited Safety (S-4). See Note b |
| IV | Immediate Occupancy (S-1) |
Life Safety (S-3). See Note c |
a. For Risk Categories I, II and III, the Tier 1 and Tier 2 procedures need not
be considered for the BSE-1E earthquake hazard level. b. For Risk Category III, the Tier 1 screening checklists shall be based on the
Collapse Prevention, except that checklist statements using the Quick Check provisions shall be based on MS -factors that are the average of the values for Collapse Prevention and Life Safety. c. For Risk Category IV, the Tier 1 screening checklists shall be based on
Collapse Prevention, except that checklist statements using the Quick Check provisions shall be based on MS -factors for Life Safety.
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — California Existing Building Code (Title 24, Part 10)
- Chapter 2 — DEFINITIONS
- Appendix A — GUIDELINES FOR
- Appendix B — SUPPLEMENTARY
- Appendix C — GUIDELINES FOR THE WIND
- Appendix D — BOARD OF
- Chapter 1 — SCOPE AND ADMINISTRATION
▸Chapter 3 — PROVISIONS FOR ALL COMPLIANCE METHODS
Overview- Section 301
- Section 302
- Section 304
- Section 303
- Section 305
- Section 306
- Section 309
- Section 310 — [OSHPD 1R, 2 and 5]
- Section 311 — [OSHPD 1R, 2 and 5]
- Section 307
- Section 308
- Section 312 — [OSHPD 1R]
- Section 313 — [SFM]
- Section 314 — [SFM]
- Section 315 — [SFM]
- Section 316 — [SFM]
- Section 317
- Section 319
- Section 318
- Section 320
- Section 321
- Section 322
- Section 323 — [DSA-SS, DSA-SS/CC]
- Section 301A
- Section 302A
- Section 303A
- Section 304A
- Section 305A
- Section 306A
- Section 307A — 309 A
- Section 310A
- Section 311A
- Section 312A
- Section 313A
- Chapter 4 — REPAIRS
- Chapter 5 — PRESCRIPTIVE COMPLIANCE METHOD
- Chapter 6 — CLASSIFICATION OF WORK
- Chapter 7 — ALTERATIONS—LEVEL 1
- Chapter 8 — ALTERATIONS—LEVEL 2
- Chapter 9 — ALTERATIONS—LEVEL 3
- Chapter 10 — CHANGE OF OCCUPANCY
- Chapter 11 — ADDITIONS
- Chapter 12 — HISTORIC BUILDINGS
- Chapter 13 — PERFORMANCE COMPLIANCE METHODS
- Chapter 14 — RELOCATED OR MOVED BUILDINGS
- Chapter 15 — CONSTRUCTION SAFEGUARDS
- Chapter 16 — REFERENCED STANDARDS