Capítulo 23 — MADERA

Sección 2308 — CONSTRUCCIÓN CON ESTRUCTURA LIGERA CONVENCIONAL

2025 California Building Code (Title 24, Part 2) · edición 2025 · actualizado 2026-07-07 · California

**2308.1 General.** Los requisitos de esta sección están destinados a edificios de…

**2308.2 Limitaciones.** Se permite la construcción de edificios conforme a las…

2308.2.1 Pisos. Las estructuras de construcción convencional con estructura ligera estarán limitadas en altura de pisos conforme a la Tabla 2308.2.1.

23-32 CÓDIGO DE CONSTRUCCIÓN DE CALIFORNIA 2025

MADERA

TABLA 2308.2.1—ALTURA PERMITIDA DE PISOS Col2
CATEGORÍA DE DISEÑO SÍSMICO PISOS PERMITIDOS SOBRE EL PLANO DE NIVEL DEL TERRENO
A y B Tres pisos
C Dos pisos
D y Ea Un piso
Para SI: 1 pulgada = 25.4 mm.
a. Para los propósitos de esta sección, para edificios asignados a la Categoría de Diseño Sísmico D o E, los muros cortos se considerarán un piso a menos que los muros cortos estén bloqueados sólidamente
y no excedan 14 pulgadas de altura.
Para SI: 1 pulgada = 25.4 mm.
a. Para los propósitos de esta sección, para edificios asignados a la Categoría de Diseño Sísmico D o E, los muros cortos se considerarán un piso a menos que los muros cortos estén bloqueados sólidamente
y no excedan 14 pulgadas de altura.

2308.2.2 Altura permitida entre pisos. La altura máxima entre pisos no deberá exceder de 11 pies, 7 pulgadas (3531 mm). La altura de muros exteriores de carga y muros interiores arriostrados no deberá exceder la altura de un montante de 10 pies (3048 mm).

2308.2.3 Cargas permitidas. Las cargas deberán cumplir con el Capítulo 16 y no deberán exceder lo siguiente:

  1. Las cargas muertas promedio no deberán exceder 15 psf (718 N/m²) para el conjunto de techo y cielo raso, muros exteriores, pisos y tabiques. Excepciones:

  2. Sujeto a las limitaciones de la Sección 2308.10.10, se permite el revestimiento de piedra o mampostería hasta un espesor menor de 5 pulgadas (127 mm) o 50 libras por pie cuadrado (2395 N/m²) instalado conforme al Capítulo 14, hasta una altura de 30 pies (9144 mm) sobre una cimentación no combustible, con 8 pies (2439 mm) adicionales permitidos para los extremos a dos aguas.

  3. Se permiten chimeneas, calefactores y conductos de concreto o mampostería conforme a las disposiciones de este código.

  4. Las cargas vivas no deberán exceder 40 psf (1916 N/m²) para pisos. Excepción: Las cargas vivas para pisos de losa de concreto sobre el terreno en Categorías de Riesgo I y II no deberán ser mayores a 125 psf (5985 N/m²).

  5. La carga de nieve permisible para diseño por esfuerzo admisible, p g(asd), no deberá exceder 50 psf (2395 N/m²).

  6. Cuando se requiera diseño para cargas de tornados, las cargas de tornados en el sistema principal resistente a fuerzas del viento y todos sus componentes y recubrimientos no deberán exceder las cargas de viento correspondientes en estos mismos elementos.

2308.2.4 Velocidad básica del viento. V no deberá exceder 130 millas por hora (57 m/s) (ráfaga de 3 segundos).

Excepciones:

  1. V no deberá exceder 140 mph (63 m/s) (ráfaga de 3 segundos) para edificios en Categoría de Exposición B que no estén ubicados en una región propensa a huracanes.
  2. Cuando V exceda 130 mph (ráfaga de 3 segundos), se permite el uso de las disposiciones de AWC WFCM o ICC 600.

2308.2.5 Luz máxima permitida para techos. Las vigas de cielo raso y cerchas construidas conforme a la Sección 2308.11 no deberán tener una luz mayor a 40 pies (12 192 mm) entre puntos de soporte vertical. Una tabla cumbrera conforme a la Sección 2308.11 o 2308.11.3.1 no se considerará soporte vertical.

2308.2.6 Limitación por categoría de riesgo. No se permitirá el uso de las disposiciones para construcción convencional con estructura ligera en esta sección para edificios de Categoría de Riesgo IV asignados a una Categoría de Diseño Sísmico distinta de A.

2308.2.7 Construcción ligera en laderas. Se deberá proporcionar diseño conforme a la Sección 2308.3 para el piso inmediatamente sobre los muros cortos o sistemas de postes y vigas, así como para todos los elementos estructurales y conexiones desde este piso hasta e incluyendo las conexiones a la cimentación y el diseño de la cimentación para transferir cargas laterales desde la estructura superior en edificios donde se cumplan todas las siguientes condiciones:

  1. La pendiente del terreno excede 1 unidad vertical en 5 unidades horizontales, promediada a lo largo de toda la longitud de cualquier lado del edificio.
  2. La altura libre del muro corto más alto excede 7 pies (2134 mm); o, cuando exista un sistema de postes y vigas en el perímetro del edificio, la altura libre del poste más alto del sistema excede 7 pies (2134 mm).
  3. Del área total del plano debajo del piso enmarcado más bajo, ya sea abierto o cerrado, menos del 50 por ciento es espacio habitable con acabados interiores de muro conforme a la Sección 2304.7 o al Capítulo 25.

Excepción: Los edificios con estructura ligera cuyo piso enmarcado más bajo esté soportado directamente sobre muros de concreto o mampostería a lo largo de todos los lados excepto el lado de pendiente descendente están exentos de esta disposición.

2308.2.8 Requisitos adicionales [DSA-SS & DSA-SS/CC y OSHPD 1R, 2 & 5] El uso de las disposiciones para construcción convencional con estructura ligera en esta sección está permitido, sujeto a las siguientes condiciones: 1. El diseño y la construcción también deberán cumplir con la Sección 2304 y la Sección 2305. 2. En conjunto con el uso de las disposiciones de la Sección 2308.10 (Arriostramiento de muros), se deberá proporcionar un análisis de ingeniería que demuestre el cumplimiento de los sistemas resistentes a fuerzas laterales conforme a la Sección 2305. 3. Además del uso de las disposiciones de la Sección 2308.8 (Estructura de pisos), se deberá proporcionar un análisis de ingeniería que demuestre el cumplimiento de los elementos y conexiones de la estructura de pisos conforme a la Sección 2302.1, Ítem 1 o 2.

4. Además del uso de las disposiciones de la Sección 2308.9 (Construcción de muros), se deberá proporcionar un análisis de ingeniería que demuestre el cumplimiento de los elementos y conexiones de la estructura de muros conforme a la Sección 2302.1, Ítem 1 o 2. 5. Además del uso de las disposiciones de la Sección 2308.11 (Estructura de techos y cielos rasos), se deberá proporcionar un análisis de ingeniería que demuestre el cumplimiento de los elementos y conexiones de la estructura de techos y cielos rasos conforme a la Sección 2302.1, Ítem 1 o 2.

**2308.3 Porciones o elementos que exceden las limitaciones de la construcción…

**2308.4 Elementos o sistemas estructurales no descritos en este documento.** Cuando un…

**2308.5 Conectores y sujetadores.** Los conectores y sujetadores utilizados en la…

**2308.6 Corte, muesca y perforación de la estructura de madera dimensional.** Las…

2308.6.1 Vigas de piso, cabios de techo y vigas de cielo raso. Las muescas en los extremos de los elementos estructurales no deberán exceder una cuarta parte de la profundidad del elemento. Las muescas en la parte superior o inferior del elemento no deberán exceder un sexto de la profundidad y no deberán ubicarse en el tercio medio del vano. Se permite una muesca de no más de un tercio de la profundidad en la parte superior de un cabio o viga de cielo raso, siempre que no esté a más distancia de la cara del soporte que la profundidad del elemento. Los orificios perforados en los elementos no deberán estar a menos de 2 pulgadas (51 mm) de la parte superior o inferior del elemento y el diámetro de dichos orificios no deberá exceder un tercio de la profundidad del elemento. Cuando el elemento tenga una muesca, el orificio no deberá estar a menos de 2 pulgadas (51 mm) de la muesca.

2308.6.1.1 Vigas de cielo raso. Cuando las vigas de cielo raso también sirvan como vigas de piso, se considerarán vigas de piso para los efectos de esta sección.

2308.6.2 Montantes de muro. En muros exteriores y tabiques portantes, un montante de madera no deberá ser cortado ni muescado en más del 25 por ciento de su profundidad. En tabiques no portantes que no soporten cargas distintas al peso del tabique, un montante no deberá ser cortado ni muescado en más del 40 por ciento de su profundidad.

2308.6.3 Orificios perforados. El diámetro de los orificios perforados en montantes de madera no deberá exceder el 40 por ciento de la profundidad del montante. En tabiques no portantes, el diámetro de los orificios perforados en montantes de madera no deberá exceder el 60 por ciento de la profundidad del montante. En cualquier muro donde cada montante esté duplicado, el diámetro de los orificios perforados en montantes de madera no deberá exceder el 60 por ciento de la profundidad del montante, siempre que no haya más de dos montantes duplicados sucesivos con dichos orificios. El borde del orificio perforado no deberá estar a menos de [5] / 8 pulgadas (15.9 mm) del borde del montante. Los orificios perforados no deberán ubicarse en la misma sección del montante donde exista un corte o muesca.

2308.6.4 Limitaciones. En los ensamblajes designados como sistemas resistentes a fuerzas laterales diseñados conforme a este código y que tengan más de tres pisos de altura o que se encuentren en las Categorías de Diseño Sísmico C, D, E y F, el corte, muesca y perforación de los montantes de muro deberá realizarse conforme a lo prescrito por el profesional registrado en diseño.

En las estructuras diseñadas conforme al California Residential Code, la modificación de los montantes de muro deberá cumplir con el California Residential Code.

2308.7 Cimentaciones y zapatas.

2308.7 Cimentaciones y zapatas. Las cimentaciones y zapatas deberán diseñarse y construirse de acuerdo con el Capítulo 18. Las conexiones a cimentaciones y zapatas deberán cumplir con esta sección.

2308.7.1 Placas o zócalos de cimentación. Las placas o zócalos de cimentación que descansan sobre cimentaciones de concreto o mampostería deberán cumplir con la Sección 2304.3.1. Las placas o zócalos de cimentación deberán estar atornillados o anclados a la cimentación con pernos de acero de no menos de [1] / 2 pulgada (12.7 mm) de diámetro o anclajes aprobados espaciados para proporcionar un anclaje equivalente al de los pernos de acero. Los pernos deberán estar embebidos no menos de 7 pulgadas (178 mm) en concreto o mampostería. Los pernos deberán ubicarse en el tercio medio del ancho de la placa. Los pernos deberán espaciarse a no más de 6 pies (1829 mm) en el centro y deberá haber no menos de dos pernos o correas de anclaje por pieza, con un perno o correa de anclaje ubicado a no más de 12 pulgadas (305 mm) ni menos de 4 pulgadas (102 mm) de cada extremo de cada pieza. Los pernos en las placas de zócalo de líneas de muros arriostrados en estructuras de más de dos pisos sobre el nivel del suelo deberán espaciarse a no más de 4 pies (1219 mm) en el centro. Se deberá apretar una tuerca y arandela de tamaño adecuado en cada perno contra la placa.

2308.7.1.1 Anclaje de placa de zócalo en línea de muro arriostrado en la Categoría de Diseño Sísmico D. Las placas de zócalo a lo largo de líneas de muros arriostrados en edificios asignados a la Categoría de Diseño Sísmico D deberán anclarse con pernos de anclaje de no menos de [1] / 2 pulgada (12.7 mm) de diámetro con arandelas de acero entre la placa de zócalo de la cimentación y la tuerca, o correas de anclaje aprobadas con capacidad de carga conforme a la Sección 2304.10.4 y espaciadas para proporcionar un anclaje equivalente. Las arandelas de placa deberán tener un tamaño no menor a 0.229 pulgadas por 3 pulgadas por 3 pulgadas (5.82 mm por 76 mm por 76 mm). Se permite que el orificio en la arandela de placa sea ranurado diagonalmente con un ancho hasta [3] / 16 pulgadas (4.76 mm) mayor que el diámetro del perno y una longitud de ranura que no exceda 1 [3] / 4 pulgadas (44 mm), siempre que se coloque una arandela estándar entre la arandela de placa y la tuerca.

2308.7.1.2 Anclaje de placa de zócalo en línea de muro arriostrado en la Categoría de Diseño Sísmico E. Las placas de zócalo a lo largo de líneas de muros arriostrados en edificios asignados a la Categoría de Diseño Sísmico E deberán anclarse con pernos de anclaje de no menos de [5] / 8 pulgada (15.9 mm) de diámetro con arandelas de acero

23-34 CÓDIGO DE CONSTRUCCIÓN DE CALIFORNIA 2025

en 18 de julio de 2025 11:14 AM (CDT) BAJO ESTE.

MADERA

entre la placa de zócalo de la cimentación y la tuerca, o correas de anclaje aprobadas con capacidad de carga conforme a la Sección 2304.10.4 y espaciadas para proporcionar un anclaje equivalente. Las arandelas de placa deberán tener un tamaño no menor a 0.229 pulgadas por 3 pulgadas por 3 pulgadas (5.82 mm por 76 mm por 76 mm). Se permite que el orificio en la arandela de placa sea ranurado diagonalmente con un ancho hasta 3 / 16 pulgadas (4.76 mm) mayor que el diámetro del perno y una longitud de ranura que no exceda 1 3 / 4 pulgadas (44 mm), siempre que se coloque una arandela estándar entre la arandela de placa y la tuerca.

2308.8 Estructura del piso. La estructura del piso deberá cumplir con esta sección.

2308.8 Estructura del piso. La estructura del piso deberá cumplir con esta sección.

2308.8.1 Vigas principales. Las vigas principales para construcciones de un solo piso o vigas que soportan cargas de un solo piso no deberán ser menores de 4 pulgadas por 6 pulgadas (102 mm por 152 mm) para luces de 6 pies (1829 mm) o menos, siempre que las vigas estén espaciadas a no más de 8 pies (2438 mm) en el centro. Otras vigas deberán diseñarse para soportar las cargas especificadas en este código. Las uniones finales de las vigas deberán ubicarse sobre los apoyos.

Cuando una viga esté empalmada sobre un apoyo, se deberá proporcionar un amarre adecuado. Los extremos de las vigas o vigas principales apoyadas sobre mampostería o concreto no deberán tener menos de 3 pulgadas (76 mm) de apoyo.

2308.8.1.1 Luces permisibles de vigas principales. Las luces permisibles de las vigas principales fabricadas con madera dimensionada no deberán exceder los valores establecidos en la Tabla 2308.8.1.1(1) o 2308.8.1.1(2).

TABLA 2308.8.1.1(1)—LUZ DE CABECERAS Y VIGAS PRINCIPALESa, b PARA MUROS DE CARGA EXTERIORES
(Luces máximas para Douglas fir-larch, hem-fir, Southern pine y spruce-pine-fir y número requerido de montantes de refuerzo)
Col2 Col3 Col4 Col5 Col6 Col7 Col8 Col9 Col10 Col11 Col12 Col13 Col14 Col15 Col16 Col17 Col18 Col19 Col20
VIGAS PRINCIPALES Y
CABECERAS
QUE SOPORTAN
TAMAÑO CARGA DE NIEVE EN EL SUELO DISEÑADA PARA ESTRÉS PERMITIDO,****pg(asd), (psf)e CARGA DE NIEVE EN EL SUELO DISEÑADA PARA ESTRÉS PERMITIDO,****pg(asd), (psf)e CARGA DE NIEVE EN EL SUELO DISEÑADA PARA ESTRÉS PERMITIDO,****pg(asd), (psf)e CARGA DE NIEVE EN EL SUELO DISEÑADA PARA ESTRÉS PERMITIDO,****pg(asd), (psf)e CARGA DE NIEVE EN EL SUELO DISEÑADA PARA ESTRÉS PERMITIDO,****pg(asd), (psf)e CARGA DE NIEVE EN EL SUELO DISEÑADA PARA ESTRÉS PERMITIDO,****pg(asd), (psf)e CARGA DE NIEVE EN EL SUELO DISEÑADA PARA ESTRÉS PERMITIDO,****pg(asd), (psf)e CARGA DE NIEVE EN EL SUELO DISEÑADA PARA ESTRÉS PERMITIDO,****pg(asd), (psf)e CARGA DE NIEVE EN EL SUELO DISEÑADA PARA ESTRÉS PERMITIDO,****pg(asd), (psf)e CARGA DE NIEVE EN EL SUELO DISEÑADA PARA ESTRÉS PERMITIDO,****pg(asd), (psf)e CARGA DE NIEVE EN EL SUELO DISEÑADA PARA ESTRÉS PERMITIDO,****pg(asd), (psf)e CARGA DE NIEVE EN EL SUELO DISEÑADA PARA ESTRÉS PERMITIDO,****pg(asd), (psf)e CARGA DE NIEVE EN EL SUELO DISEÑADA PARA ESTRÉS PERMITIDO,****pg(asd), (psf)e CARGA DE NIEVE EN EL SUELO DISEÑADA PARA ESTRÉS PERMITIDO,****pg(asd), (psf)e CARGA DE NIEVE EN EL SUELO DISEÑADA PARA ESTRÉS PERMITIDO,****pg(asd), (psf)e CARGA DE NIEVE EN EL SUELO DISEÑADA PARA ESTRÉS PERMITIDO,****pg(asd), (psf)e CARGA DE NIEVE EN EL SUELO DISEÑADA PARA ESTRÉS PERMITIDO,****pg(asd), (psf)e CARGA DE NIEVE EN EL SUELO DISEÑADA PARA ESTRÉS PERMITIDO,****pg(asd), (psf)e
VIGAS PRINCIPALES Y
CABECERAS
QUE SOPORTAN
TAMAÑO 30 30 30 30 30 30 50 50 50 50 50 50 70 70 70 70 70 70
VIGAS PRINCIPALES Y
CABECERAS
QUE SOPORTAN
TAMAÑO Ancho del edificioc (pies) Ancho del edificioc (pies) Ancho del edificioc (pies) Ancho del edificioc (pies) Ancho del edificioc (pies) Ancho del edificioc (pies) Ancho del edificioc (pies) Ancho del edificioc (pies) Ancho del edificioc (pies) Ancho del edificioc (pies) Ancho del edificioc (pies) Ancho del edificioc (pies) Ancho del edificioc (pies) Ancho del edificioc (pies) Ancho del edificioc (pies) Ancho del edificioc (pies) Ancho del edificioc (pies) Ancho del edificioc (pies)
VIGAS PRINCIPALES Y
CABECERAS
QUE SOPORTAN
TAMAÑO 12 12 24 24 36 36 12 12 24 24 36 36 12 12 24 24 36 36
VIGAS PRINCIPALES Y
CABECERAS
QUE SOPORTAN
TAMAÑO Luzf NJd Luzf NJd Luzf NJd Luzf NJd Luzf NJd Luzf NJd Luzf NJd Luzf NJd Luzf NJd
Techo y cielo raso 1-2 × 6 4-0 1 3-1 2 2-7 2 3-5 1 2-8 2 2-3 2 3-0 2 2-4 2 2-0 2
Techo y cielo raso 1-2 × 8 5-1 2 3-11 2 3-3 2 4-4 2 3-4 2 2-10 2 3-10 2 3-0 2 2-6 3
Techo y cielo raso 1-2 × 10 6-0 2 4-8 2 3-11 2 5-2 2 4-0 2 3-4 3 4-7 2 3-6 3 3-0 3
Techo y cielo raso 1-2 × 12 7-1 2 5-5 2 4-7 3 6-1 2 4-8 3 3-11 3 5-5 2 4-2 3 3-6 3
Techo y cielo raso 2-2 × 4 4-0 1 3-1 1 2-7 1 3-5 1 2-7 1 2-2 1 3-0 1 2-4 1 2-0 1
Techo y cielo raso 2-2 × 6 6-0 1 4-7 1 3-10 1 5-1 1 3-11 1 3-3 2 4-6 1 3-6 2 2-11 2
Techo y cielo raso 2-2 × 8 7-7 1 5-9 1 4-10 2 6-5 1 5-0 2 4-2 2 5-9 1 4-5 2 3-9 2
Techo y cielo raso 2-2 × 10 9-0 1 6-10 2 5-9 2 7-8 2 5-11 2 4-11 2 6-9 2 5-3 2 4-5 2
Techo y cielo raso 2-2 × 12 10-7 2 8-1 2 6-10 2 9-0 2 6-11 2 5-10 2 8-0 2 6-2 2 5-2 3
Techo y cielo raso 3-2 × 8 9-5 1 7-3 1 6-1 1 8-1 1 6-3 1 5-3 2 7-2 1 5-6 2 4-8 2
Techo y cielo raso 3-2 × 10 11-3 1 8-7 1 7-3 2 9-7 1 7-4 2 6-2 2 8-6 1 6-7 2 5-6 2
Techo y cielo raso 3-2 × 12 13-2 1 10-1 2 8-6 2 11-3 2 8-8 2 7-4 2 10-0 2 7-9 2 6-6 2
Techo y cielo raso 4-2 × 8 10-11 1 8-4 1 7-0 1 9-4 1 7-2 1 6-0 1 8-3 1 6-4 1 5-4 2
Techo y cielo raso 4-2 × 10 12-11 1 9-11 1 8-4 1 11-1 1 8-6 1 7-2 2 9-10 1 7-7 2 6-4 2
Techo y cielo raso 4-2 × 12 15-3 1 11-8 1 9-10 2 13-0 1 10-0 2 8-5 2 11-7 1 8-11 2 7-6 2
Techo, cielo raso y
un piso con
apoyo central
1-2 × 6 3-3 1 2-7 2 2-2 2 3-0 2 2-4 2 2-0 2 2-9 2 2-2 2 1-10 2
Techo, cielo raso y
un piso con
apoyo central
1-2 × 8 4-1 2 3-3 2 2-9 2 3-9 2 3-0 2 2-6 3 3-6 2 2-9 2 2-4 3
Techo, cielo raso y
un piso con
apoyo central
1-2 × 10 4-11 2 3-10 2 3-3 3 4-6 2 3-6 3 3-0 3 4-1 2 3-3 3 2-9 3
Techo, cielo raso y
un piso con
apoyo central
1-2 × 12 5-9 2 4-6 3 3-10 3 5-3 2 4-2 3 3-6 3 4-10 3 3-10 3 3-3 4
Techo, cielo raso y
un piso con
apoyo central
2-2 × 4 3-3 1 2-6 1 2-2 1 3-0 1 2-4 1 2-0 1 2-8 1 2-2 1 1-10 1
Techo, cielo raso y
un piso con
apoyo central
2-2 × 6 4-10 1 3-9 1 3-3 2 4-5 1 3-6 2 3-0 2 4-1 1 3-3 2 2-9 2
Techo, cielo raso y
un piso con
apoyo central
2-2 × 8 6-1 1 4-10 2 4-1 2 5-7 2 4-5 2 3-9 2 5-2 2 4-1 2 3-6 2
Techo, cielo raso y
un piso con
apoyo central
2-2 × 10 7-3 2 5-8 2 4-10 2 6-8 2 5-3 2 4-5 2 6-1 2 4-10 2 4-1 2
Techo, cielo raso y
un piso con
apoyo central
2-2 × 12 8-6 2 6-8 2 5-8 2 7-10 2 6-2 2 5-3 3 7-2 2 5-8 2 4-10 3
Techo, cielo raso y
un piso con
apoyo central
3-2 × 8 7-8 1 6-0 1 5-1 2 7-0 1 5-6 2 4-8 2 6-5 1 5-1 2 4-4 2
Techo, cielo raso y
un piso con
apoyo central
3-2 × 10 9-1 1 7-2 2 6-1 2 8-4 1 6-7 2 5-7 2 7-8 2 6-1 2 5-2 2
Techo, cielo raso y
un piso con
apoyo central
3-2 × 12 10-8 2 8-5 2 7-2 2 9-10 2 7-8 2 6-7 2 9-0 2 7-1 2 6-1 2
Techo, cielo raso y
un piso con
apoyo central
4-2 × 8 8-10 1 6-11 1 5-11 1 8-1 1 6-4 1 5-5 2 7-5 1 5-11 1 5-0 2
Techo, cielo raso y
un piso con
apoyo central
4-2 × 10 10-6 1 8-3 2 7-0 2 9-8 1 7-7 2 6-5 2 8-10 1 7-0 2 6-0 2
Techo, cielo raso y
un piso con
apoyo central
4-2 × 12 12-4 1 9-8 2 8-3 2 11-4 2 8-11 2 7-7 2 10-4 2 8-3 2 7-0 2

el 18 de julio de 2025 11:14 AM (CDT) BAJO ESTO.

MADERA

TABLA 2308.8.1.1(1)—LUCES DE CABECERAS Y VIGASa, b PARA MUROS DE APOYO EXTERIORESc
(Luces máximas para Douglas fir-larch, hem-fir, Southern pine y spruce-pine-fir y número requerido de montantes de refuerzo)—continuación
Col2 Col3 Col4 Col5 Col6 Col7 Col8 Col9 Col10 Col11 Col12 Col13 Col14 Col15 Col16 Col17 Col18 Col19 Col20
VIGAS Y
CABECERAS
QUE SOPORTAN
TAMAÑO Carga de nieve en el suelo permisible por diseño a tensión,****pg(asd), (psf)e Carga de nieve en el suelo permisible por diseño a tensión,****pg(asd), (psf)e Carga de nieve en el suelo permisible por diseño a tensión,****pg(asd), (psf)e Carga de nieve en el suelo permisible por diseño a tensión,****pg(asd), (psf)e Carga de nieve en el suelo permisible por diseño a tensión,****pg(asd), (psf)e Carga de nieve en el suelo permisible por diseño a tensión,****pg(asd), (psf)e Carga de nieve en el suelo permisible por diseño a tensión,****pg(asd), (psf)e Carga de nieve en el suelo permisible por diseño a tensión,****pg(asd), (psf)e Carga de nieve en el suelo permisible por diseño a tensión,****pg(asd), (psf)e Carga de nieve en el suelo permisible por diseño a tensión,****pg(asd), (psf)e Carga de nieve en el suelo permisible por diseño a tensión,****pg(asd), (psf)e Carga de nieve en el suelo permisible por diseño a tensión,****pg(asd), (psf)e Carga de nieve en el suelo permisible por diseño a tensión,****pg(asd), (psf)e Carga de nieve en el suelo permisible por diseño a tensión,****pg(asd), (psf)e Carga de nieve en el suelo permisible por diseño a tensión,****pg(asd), (psf)e Carga de nieve en el suelo permisible por diseño a tensión,****pg(asd), (psf)e Carga de nieve en el suelo permisible por diseño a tensión,****pg(asd), (psf)e Carga de nieve en el suelo permisible por diseño a tensión,****pg(asd), (psf)e
VIGAS Y
CABECERAS
QUE SOPORTAN
TAMAÑO 30 30 30 30 30 30 50 50 50 50 50 50 70 70 70 70 70 70
VIGAS Y
CABECERAS
QUE SOPORTAN
TAMAÑO Ancho del edificioc (pies) Ancho del edificioc (pies) Ancho del edificioc (pies) Ancho del edificioc (pies) Ancho del edificioc (pies) Ancho del edificioc (pies) Ancho del edificioc (pies) Ancho del edificioc (pies) Ancho del edificioc (pies) Ancho del edificioc (pies) Ancho del edificioc (pies) Ancho del edificioc (pies) Ancho del edificioc (pies) Ancho del edificioc (pies) Ancho del edificioc (pies) Ancho del edificioc (pies) Ancho del edificioc (pies) Ancho del edificioc (pies)
VIGAS Y
CABECERAS
QUE SOPORTAN
TAMAÑO 12 12 24 24 36 36 12 12 24 24 36 36 12 12 24 24 36 36
VIGAS Y
CABECERAS
QUE SOPORTAN
TAMAÑO Luzf NJd Luzf NJd Luzf NJd Luzf NJd Luzf NJd Luzf NJd Luzf NJd Luzf NJd Luzf NJd
Techo, cielo raso y
un claro en
piso
1-2 × 6 2-11 2 2-3 2 1-11 2 2-9 2 2-1 2 1-9 2 2-7 2 2-0 2 1-8 2
Techo, cielo raso y
un claro en
piso
1-2 × 8 3-9 2 2-10 2 2-5 3 3-6 2 2-8 2 2-3 3 3-3 2 2-6 3 2-2 3
Techo, cielo raso y
un claro en
piso
1-2 × 10 4-5 2 3-5 3 2-10 3 4-2 2 3-2 3 2-8 3 3-11 2 3-0 3 2-6 3
Techo, cielo raso y
un claro en
piso
1-2 × 12 5-2 2 4-0 3 3-4 3 4-10 3 3-9 3 3-2 4 4-7 3 3-6 3 3-0 4
Techo, cielo raso y
un claro en
piso
2-2 × 4 2-11 1 2-3 1 1-10 1 2-9 1 2-1 1 1-9 1 2-7 1 2-0 1 1-8 1
Techo, cielo raso y
un claro en
piso
2-2 × 6 4-4 1 3-4 2 2-10 2 4-1 1 3-2 2 2-8 2 3-10 1 3-0 2 2-6 2
Techo, cielo raso y
un claro en
piso
2-2 × 8 5-6 2 4-3 2 3-7 2 5-2 2 4-0 2 3-4 2 4-10 2 3-9 2 3-2 2
Techo, cielo raso y
un claro en
piso
2-2 × 10 6-7 2 5-0 2 4-2 2 6-1 2 4-9 2 4-0 2 5-9 2 4-5 2 3-9 3
Techo, cielo raso y
un claro en
piso
2-2 × 12 7-9 2 5-11 2 4-11 3 7-2 2 5-7 2 4-8 3 6-9 2 5-3 3 4-5 3
Techo, cielo raso y
un claro en
piso
3-2 × 8 6-11 1 5-3 2 4-5 2 6-5 1 5-0 2 4-2 2 6-1 1 4-8 2 4-0 2
Techo, cielo raso y
un claro en
piso
3-2 × 10 8-3 2 6-3 2 5-3 2 7-8 2 5-11 2 5-0 2 7-3 2 5-7 2 4-8 2
Techo, cielo raso y
un claro en
piso
3-2 × 12 9-8 2 7-5 2 6-2 2 9-0 2 7-0 2 5-10 2 8-6 2 6-7 2 5-6 3
Techo, cielo raso y
un claro en
piso
4-2 × 8 8-0 1 6-1 1 5-1 2 7-5 1 5-9 2 4-10 2 7-0 1 5-5 2 4-7 2
Techo, cielo raso y
un claro en
piso
4-2 × 10 9-6 1 7-3 2 6-1 2 8-10 1 6-10 2 5-9 2 8-4 1 6-5 2 5-5 2
Techo, cielo raso y
un claro en
piso
4-2 × 12 11-2 2 8-6 2 7-2 2 10-5 2 8-0 2 6-9 2 9-10 2 7-7 2 6-5 2
Techo, cielo raso y
dos pisos con
apoyo central
1-2 × 6 2-8 2 2-1 2 1-10 2 2-7 2 2-0 2 1-9 2 2-5 2 1-11 2 1-8 2
Techo, cielo raso y
dos pisos con
apoyo central
1-2 × 8 3-5 2 2-8 2 2-4 3 3-3 2 2-7 2 2-2 3 3-1 2 2-5 3 2-1 3
Techo, cielo raso y
dos pisos con
apoyo central
1-2 × 10 4-0 2 3-2 3 2-9 3 3-10 2 3-1 3 2-7 3 3-8 2 2-11 3 2-5 3
Techo, cielo raso y
dos pisos con
apoyo central
1-2 × 12 4-9 3 3-9 3 3-2 4 4-6 3 3-7 3 3-1 4 4-3 3 3-5 3 2-11 4
Techo, cielo raso y
dos pisos con
apoyo central
2-2 × 4 2-8 1 2-1 1 1-9 1 2-6 1 2-0 1 1-8 1 2-5 1 1-11 1 1-7 1
Techo, cielo raso y
dos pisos con
apoyo central
2-2 × 6 4-0 1 3-2 2 2-8 2 3-9 1 3-0 2 2-7 2 3-7 1 2-10 2 2-5 2
Techo, cielo raso y
dos pisos con
apoyo central
2-2 × 8 5-0 2 4-0 2 3-5 2 4-10 2 3-10 2 3-3 2 4-7 2 3-7 2 3-1 2
Techo, cielo raso y
dos pisos con
apoyo central
2-2 × 10 6-0 2 4-9 2 4-0 2 5-8 2 4-6 2 3-10 3 5-5 2 4-3 2 3-8 3
Techo, cielo raso y
dos pisos con
apoyo central
2-2 × 12 7-0 2 5-7 2 4-9 3 6-8 2 5-4 3 4-6 3 6-4 2 5-0 3 4-3 3
Techo, cielo raso y
dos pisos con
apoyo central
3-2 × 8 6-4 1 5-0 2 4-3 2 6-0 1 4-9 2 4-1 2 5-8 2 4-6 2 3-10 2
Techo, cielo raso y
dos pisos con
apoyo central
3-2 × 10 7-6 2 5-11 2 5-1 2 7-1 2 5-8 2 4-10 2 6-9 2 5-4 2 4-7 2
Techo, cielo raso y
dos pisos con
apoyo central
3-2 × 12 8-10 2 7-0 2 5-11 2 8-5 2 6-8 2 5-8 3 8-0 2 6-4 2 5-4 3
Techo, cielo raso y
dos pisos con
apoyo central
4-2 × 8 7-3 1 5-9 1 4-11 2 6-11 1 5-6 2 4-8 2 6-7 1 5-2 2 4-5 2
Techo, cielo raso y
dos pisos con
apoyo central
4-2 × 10 8-8 1 6-10 2 5-10 2 8-3 2 6-6 2 5-7 2 7-10 2 6-2 2 5-3 2
Techo, cielo raso y
dos pisos con
apoyo central
4-2 × 12 10-2 2 8-1 2 6-10 2 9-8 2 7-8 2 6-7 2 9-2 2 7-3 2 6-2 2
Techo, cielo raso y
dos claros en
pisos
1-2 × 6 2-3 2 1-9 2 1-5 2 2-3 2 1-9 2 1-5 3 2-2 2 1-8 2 1-5 3
Techo, cielo raso y
dos claros en
pisos
1-2 × 8 2-10 2 2-2 3 1-10 3 2-10 2 2-2 3 1-10 3 2-9 2 2-1 3 1-10 3
Techo, cielo raso y
dos claros en
pisos
1-2 × 10 3-4 2 2-7 3 2-2 3 3-4 3 2-7 3 2-2 4 3-3 3 2-6 3 2-2 4
Techo, cielo raso y
dos claros en
pisos
1-2 × 12 4-0 3 3-0 3 2-7 4 4-0 3 3-0 4 2-7 4 3-10 3 3-0 4 2-6 4
Techo, cielo raso y
dos claros en
pisos
2-2 × 4 2-3 1 1-8 1 1-4 1 2-3 1 1-8 1 1-4 1 2-2 1 1-8 1 1-4 2
Techo, cielo raso y
dos claros en
pisos
2-2 × 6 3-4 1 2-6 2 2-2 2 3-4 2 2-6 2 2-2 2 3-3 2 2-6 2 2-1 2
Techo, cielo raso y
dos claros en
pisos
2-2 × 8 4-3 2 3-3 2 2-8 2 4-3 2 3-3 2 2-8 2 4-1 2 3-2 2 2-8 3
Techo, cielo raso y
dos claros en
pisos
2-2 × 10 5-0 2 3-10 2 3-2 3 5-0 2 3-10 2 3-2 3 4-10 2 3-9 3 3-2 3
Techo, cielo raso y
dos claros en
pisos
2-2 × 12 5-11 2 4-6 3 3-9 3 5-11 2 4-6 3 3-9 3 5-8 2 4-5 3 3-9 3
Techo, cielo raso y
dos claros en
pisos
3-2 × 8 5-3 1 4-0 2 3-5 2 5-3 2 4-0 2 3-5 2 5-1 2 3-11 2 3-4 2
Techo, cielo raso y
dos claros en
pisos
3-2 × 10 6-3 2 4-9 2 4-0 2 6-3 2 4-9 2 4-0 2 6-1 2 4-8 2 4-0 3
Techo, cielo raso y
dos claros en
pisos
3-2 × 12 7-5 2 5-8 2 4-9 3 7-5 2 5-8 2 4-9 3 7-2 2 5-6 3 4-8 3
Techo, cielo raso y
dos claros en
pisos
4-2 × 8 6-1 1 4-8 2 3-11 2 6-1 1 4-8 2 3-11 2 5-11 1 4-7 2 3-10 2
Techo, cielo raso y
dos claros en
pisos
4-2 × 10 7-3 2 5-6 2 4-8 2 7-3 2 5-6 2 4-8 2 7-0 2 5-5 2 4-7 2
Techo, cielo raso y
dos claros en
pisos
4-2 × 12 8-6 2 6-6 2 5-6 2 8-6 2 6-6 2 5-6 2 8-3 2 6-4 2 5-4 3
Para SI: 1 pulgada = 25.4 mm, 1 libra por pie cuadrado = 0.0479 kPa.
a. Las luces se indican en pies y pulgadas.
b. Las luces se basan en las propiedades mínimas de diseño para madera grado No. 2 de Douglas fir-larch, hem-fir, Southern pine y spruce-pine fir.
c. El ancho del edificio se mide perpendicular a la cumbrera. Para anchos entre los indicados, se permite interpolar las luces.
d. NJ = Número de montantes de refuerzo requeridos para soportar cada extremo. Cuando el número requerido de montantes de refuerzo es uno, se permite que la cabecera sea soportada por un anclaje aprobado de la estructura fijado al montante de pared de altura completa y a la cabecera.
e. Use una carga de nieve en el suelo permisible por diseño a tensión de 30 psf para casos en que la carga permisible por diseño a tensión sea menor de 30 psf y la carga viva del techo sea igual o menor a 20 psf.
f. Las luces se calculan asumiendo que la parte superior de la cabecera o viga está arriostrada lateralmente por estructura perpendicular. Cuando la parte superior de la cabecera o viga no está arriostrada lateralmente (por ejemplo, montantes cortos que apoyan en la cabecera), las luces tabuladas para cabeceras de tamaños 2 × 8, 2 × 10 o 2 × 12 deben multiplicarse por 0.70 o la cabecera o viga debe ser diseñada.

23-36 CÓDIGO DE CONSTRUCCIÓN DE CALIFORNIA 2025

a las 11:14 AM (CDT) del 18 de julio de 2025 BAJO ESTE.

MADERA

TABLA 2308.8.1.1(2)—LUCES DE CABECERAS Y VIGASa, b PARA MUROS DE APOYO INTERIORES
(Luces máximas para abeto Douglas-lárice, hem-fir, pino sureño y abeto-pino-fir y número requerido de montantes de apoyo)
Col2 Col3 Col4 Col5 Col6 Col7 Col8
CABECERAS Y
VIGAS QUE SOPORTAN
TAMAÑO ANCHO DEL EDIFICIOc (pies) ANCHO DEL EDIFICIOc (pies) ANCHO DEL EDIFICIOc (pies) ANCHO DEL EDIFICIOc (pies) ANCHO DEL EDIFICIOc (pies) ANCHO DEL EDIFICIOc (pies)
CABECERAS Y
VIGAS QUE SOPORTAN
TAMAÑO 12 12 24 24 36 36
CABECERAS Y
VIGAS QUE SOPORTAN
TAMAÑO Luze NJd Luze NJd Luze NJd
Solo un piso 2-2 × 4 4-1 1 2-10 1 2-4 1
Solo un piso 2-2 × 6 6-1 1 4-4 1 3-6 1
Solo un piso 2-2 × 8 7-9 1 5-5 1 4-5 2
Solo un piso 2-2 × 10 9-2 1 6-6 2 5-3 2
Solo un piso 2-2 × 12 10-9 1 7-7 2 6-3 2
Solo un piso 3-2 × 8 9-8 1 6-10 1 5-7 1
Solo un piso 3-2 × 10 11-5 1 8-1 1 6-7 2
Solo un piso 3-2 × 12 13-6 1 9-6 2 7-9 2
Solo un piso 4-2 × 8 11-2 1 7-11 1 6-5 1
Solo un piso 4-2 × 10 13-3 1 9-4 1 7-8 1
Solo un piso 4-2 × 12 15-7 1 11-0 1 9-0 2
Dos pisos 2-2 × 4 2-7 1 1-11 1 1-7 1
Dos pisos 2-2 × 6 3-11 1 2-11 2 2-5 2
Dos pisos 2-2 × 8 5-0 1 3-8 2 3-1 2
Dos pisos 2-2 × 10 5-11 2 4-4 2 3-7 2
Dos pisos 2-2 × 12 6-11 2 5-2 2 4-3 3
Dos pisos 3-2 × 8 6-3 1 4-7 2 3-10 2
Dos pisos 3-2 × 10 7-5 1 5-6 2 4-6 2
Dos pisos 3-2 × 12 8-8 2 6-5 2 5-4 2
Dos pisos 4-2 × 8 7-2 1 5-4 1 4-5 2
Dos pisos 4-2 × 10 8-6 1 6-4 2 5-3 2
Dos pisos 4-2 × 12 10-1 1 7-5 2 6-2 2
Para SI: 1 pulgada = 25.4 mm, 1 pie = 304.8 mm.
a. Las luces se dan en pies y pulgadas.
b. Las luces se basan en las propiedades mínimas de diseño para madera grado No. 2 de abeto Douglas-lárice, hem-fir, pino sureño y abeto-pino-fir.
c._ El ancho_ del edificio se mide perpendicular a la cumbrera. Para anchos entre los mostrados, se permite interpolar las luces.
d. NJ = Número de montantes de apoyo requeridos para soportar cada extremo. Cuando el número de montantes requeridos es uno, se permite que la cabecera sea soportada por un anclaje de estructura_ aprobado_ fijado al montante de pared de altura completa y a la cabecera.
e. Las luces se calculan asumiendo que la parte superior de la cabecera o viga está arriostrada lateralmente por estructura perpendicular. Cuando la parte superior de la cabecera o viga no está arriostrada lateralmente (por ejemplo, montantes cortos que apoyan en la cabecera), las luces tabuladas para cabeceras de tamaños 2 × 8, 2 × 10 o 2 × 12 deben multiplicarse por 0.70 o la cabecera o viga debe diseñarse.
Para SI: 1 pulgada = 25.4 mm, 1 pie = 304.8 mm.
a. Las luces se dan en pies y pulgadas.
b. Las luces se basan en las propiedades mínimas de diseño para madera grado No. 2 de abeto Douglas-lárice, hem-fir, pino sureño y abeto-pino-fir.
c._ El ancho_ del edificio se mide perpendicular a la cumbrera. Para anchos entre los mostrados, se permite interpolar las luces.
d. NJ = Número de montantes de apoyo requeridos para soportar cada extremo. Cuando el número de montantes requeridos es uno, se permite que la cabecera sea soportada por un anclaje de estructura_ aprobado_ fijado al montante de pared de altura completa y a la cabecera.
e. Las luces se calculan asumiendo que la parte superior de la cabecera o viga está arriostrada lateralmente por estructura perpendicular. Cuando la parte superior de la cabecera o viga no está arriostrada lateralmente (por ejemplo, montantes cortos que apoyan en la cabecera), las luces tabuladas para cabeceras de tamaños 2 × 8, 2 × 10 o 2 × 12 deben multiplicarse por 0.70 o la cabecera o viga debe diseñarse.

2308.8.2 Vigas de piso. Las vigas de piso deberán cumplir con esta sección.

2308.8.2.1 Luz. Las luces para vigas de piso deberán estar de acuerdo con la Tabla 2308.8.2.1(1), Tabla 2308.8.2.1(2) o el AWC STJR.

a las 11:14 AM (CDT) del 18 de julio de 2025 BAJO ESTE.

MADERA

TABLA 2308.8.2.1(1)—LUCES DE VIGAS DE PISO PARA ESPECIES COMUNES DE MADERA
(Áreas residenciales para dormir, carga viva = 30 psf, L/Δ = 360)
Col2 Col3 Col4 Col5 Col6 Col7 Col8 Col9 Col10 Col11
ESPACIADO DE
VIGAS
(pulgadas)
ESPECIE Y GRADO ESPECIE Y GRADO CARGA MUERTA = 10 psf CARGA MUERTA = 10 psf CARGA MUERTA = 10 psf CARGA MUERTA = 10 psf CARGA MUERTA = 20 psf CARGA MUERTA = 20 psf CARGA MUERTA = 20 psf CARGA MUERTA = 20 psf
ESPACIADO DE
VIGAS
(pulgadas)
ESPECIE Y GRADO ESPECIE Y GRADO 2 × 6 2 × 8 2 × 10 2 × 12 2 × 6 2 × 8 2 × 10 2 × 12
ESPACIADO DE
VIGAS
(pulgadas)
ESPECIE Y GRADO ESPECIE Y GRADO Luces máximas de vigas de piso Luces máximas de vigas de piso Luces máximas de vigas de piso Luces máximas de vigas de piso Luces máximas de vigas de piso Luces máximas de vigas de piso Luces máximas de vigas de piso Luces máximas de vigas de piso
ESPACIADO DE
VIGAS
(pulgadas)
ESPECIE Y GRADO ESPECIE Y GRADO (pies - pulg.) (pies - pulg.) (pies - pulg.) (pies - pulg.) (pies - pulg.) (pies - pulg.) (pies - pulg.) (pies - pulg.)
12 Abeto Douglas-Lárice SS 12-6 16-6 21-0 25-7 12-6 16-6 21-0 25-7
12 Abeto Douglas-Lárice #1 12-0 15-10 20-3 24-8 12-0 15-7 19-0 22-0
12 Abeto Douglas-Lárice #2 11-10 15-7 19-10 23-0 11-6 14-7 17-9 20-7
12 Abeto Douglas-Lárice #3 9-8 12-4 15-0 17-5 8-8 11-0 13-5 15-7
12 Hem-Fir SS 11-10 15-7 19-10 24-2 11-10 15-7 19-10 24-2
12 Hem-Fir #1 11-7 15-3 19-5 23-7 11-7 15-2 18-6 21-6
12 Hem-Fir #2 11-0 14-6 18-6 22-6 11-0 14-4 17-6 20-4
12 Hem-Fir #3 9-8 12-4 15-0 17-5 8-8 11-0 13-5 15-7
12 Pino Sureño SS 12-3 16-2 20-8 25-1 12-3 16-2 20-8 25-1
12 Pino Sureño #1 11-10 15-7 19-10 24-2 11-10 15-7 18-7 22-0
12 Pino Sureño #2 11-3 14-11 18-1 21-4 10-9 13-8 16-2 19-1
12 Pino Sureño #3 9-2 11-6 14-0 16-6 8-2 10-3 12-6 14-9
12 Abeto-Pino-Fir SS 11-7 15-3 19-5 23-7 11-7 15-3 19-5 23-7
12 Abeto-Pino-Fir #1 11-3 14-11 19-0 23-0 11-3 14-7 17-9 20-7
12 Abeto-Pino-Fir #2 11-3 14-11 19-0 23-0 11-3 14-7 17-9 20-7
12 Abeto-Pino-Fir #3 9-8 12-4 15-0 17-5 8-8 11-0 13-5 15-7
16 Abeto Douglas-Lárice SS 11-4 15-0 19-1 23-3 11-4 15-0 19-1 23-0
16 Abeto Douglas-Lárice #1 10-11 14-5 18-5 21-4 10-8 13-6 16-5 19-1
16 Abeto Douglas-Lárice #2 10-9 14-1 17-2 19-11 9-11 12-7 15-5 17-10
16 Abeto Douglas-Lárice #3 8-5 10-8 13-0 15-1 7-6 9-6 11-8 13-6
16 Hem-Fir SS 10-9 14-2 18-0 21-11 10-9 14-2 18-0 21-11
16 Hem-Fir #1 10-6 13-10 17-8 20-9 10-4 13-1 16-0 18-7
16 Hem-Fir #2 10-0 13-2 16-10 19-8 9-10 12-5 15-2 17-7
16 Hem-Fir #3 8-5 10-8 13-0 15-1 7-6 9-6 11-8 13-6
16 Pino Sureño SS 11-2 14-8 18-9 22-10 11-2 14-8 18-9 22-10
16 Pino Sureño #1 10-9 14-2 18-0 21-4 10-9 13-9 16-1 19-1
16 Pino Sureño #2 10-3 13-3 15-8 18-6 9-4 11-10 14-0 16-6
16 Pino Sureño #3 7-11 10-10 12-1 14-4 7-1 8-11 10-10 12-10
16 Abeto-Pino-Fir SS 10-6 13-10 17-8 21-6 10-6 13-10 17-8 21-4
16 Abeto-Pino-Fir #1 10-3 13-6 17-2 19-11 9-11 12-7 15-5 17-10
16 Abeto-Pino-Fir #2 10-3 13-6 17-2 19-11 9-11 12-7 15-5 17-10
16 Abeto-Pino-Fir #3 8-5 10-8 13-0 15-1 7-6 9-6 11-8 13-6

23-38 CÓDIGO DE CONSTRUCCIÓN DE CALIFORNIA 2025

a las 11:14 AM (CDT) del 18 de julio de 2025 BAJO ESTE.

MADERA

TABLA 2308.8.2.1(1)—LUCES DE VIGAS DE PISO PARA ESPECIES COMUNES DE MADERA
(Áreas residenciales para dormir, carga viva = 30 psf, L/Δ = 360)—continuación
Col2 Col3 Col4 Col5 Col6 Col7 Col8 Col9 Col10 Col11
ESPACIADO DE
VIGAS
(pulgadas)
ESPECIE Y GRADO ESPECIE Y GRADO CARGA MUERTA = 10 psf CARGA MUERTA = 10 psf CARGA MUERTA = 10 psf CARGA MUERTA = 10 psf CARGA MUERTA = 20 psf CARGA MUERTA = 20 psf CARGA MUERTA = 20 psf CARGA MUERTA = 20 psf
ESPACIADO DE
VIGAS
(pulgadas)
ESPECIE Y GRADO ESPECIE Y GRADO 2 × 6 2 × 8 2 × 10 2 × 12 2 × 6 2 × 8 2 × 10 2 × 12
ESPACIADO DE
VIGAS
(pulgadas)
ESPECIE Y GRADO ESPECIE Y GRADO Luces máximas de vigas de piso Luces máximas de vigas de piso Luces máximas de vigas de piso Luces máximas de vigas de piso Luces máximas de vigas de piso Luces máximas de vigas de piso Luces máximas de vigas de piso Luces máximas de vigas de piso
ESPACIADO DE
VIGAS
(pulgadas)
ESPECIE Y GRADO ESPECIE Y GRADO (pies - pulg.) (pies - pulg.) (pies - pulg.) (pies - pulg.) (pies - pulg.) (pies - pulg.) (pies - pulg.) (pies - pulg.)
19.2 Abeto Douglas-Lárice SS 10-8 14-1 18-0 21-10 10-8 14-1 18-0 21-0
19.2 Abeto Douglas-Lárice #1 10-4 13-7 16-9 19-6 9-8 12-4 15-0 17-5
19.2 Abeto Douglas-Lárice #2 10-1 12-10 15-8 18-3 9-1 11-6 14-1 16-3
19.2 Abeto Douglas-Lárice #3 7-8 9-9 11-10 13-9 6-10 8-8 10-7 12-4
19.2 Hem-Fir SS 10-1 13-4 17-0 20-8 10-1 13-4 17-0 20-7
19.2 Hem-Fir #1 9-10 13-0 16-4 19-0 9-6 12-0 14-8 17-0
19.2 Hem-Fir #2 9-5 12-5 15-6 17-1 8-11 11-4 13-10 16-1
19.2 Hem-Fir #3 7-8 9-9 11-10 13-9 6-10 8-8 10-7 12-4
19.2 Pino Sureño SS 10-6 13-10 17-8 21-6 10-6 13-10 17-8 21-6
19.2 Pino Sureño #1 10-1 13-4 16-5 19-6 9-11 12-7 14-8 17-5
19.2 Pino Sureño #2 9-6 12-1 14-4 16-10 8-6 10-10 12-10 15-1
19.2 Pino Sureño #3 7-3 9-1 11-0 13-1 6-5 8-2 9-10 11-8
19.2 Abeto-Pino-Fir SS 9-10 13-0 16-7 20-2 9-10 13-0 16-7 19-6
19.2 Abeto-Pino-Fir #1 9-8 12-9 15-8 18-3 9-1 11-6 14-1 16-3
19.2 Abeto-Pino-Fir #2 9-8 12-9 15-8 18-3 9-1 11-6 14-1 16-3
19.2 Abeto-Pino-Fir #3 7-8 9-9 11-10 13-9 6-10 8-8 10-7 12-4
24 Abeto Douglas-Lárice SS 9-11 13-1 16-8 20-3 9-11 13-1 16-2 18-9
24 Abeto Douglas-Lárice #1 9-7 12-4 15-0 17-5 8-8 11-0 13-5 15-7
24 Abeto Douglas-Lárice #2 9-1 11-6 14-1 16-3 8-1 10-3 12-7 14-7
24 Abeto Douglas-Lárice #3 6-10 8-8 10-7 12-4 6-2 7-9 9-6 11-0
24 Hem-Fir SS 9-4 12-4 15-9 19-2 9-4 12-4 15-9 18-5
24 Hem-Fir #1 9-2 12-0 14-8 17-0 8-6 10-9 13-1 15-2
24 Hem-Fir #2 8-9 11-4 13-10 16-1 8-0 10-2 12-5 14-4
24 Hem-Fir #3 6-10 8-8 10-7 12-4 6-2 7-9 9-6 11-0
24 Pino Sureño SS 9-9 12-10 16-5 19-11 9-9 12-10 16-5 19-8
24 Pino Sureño #1 9-4 12-4 14-8 17-5 8-10 11-3 13-1 15-7
24 Pino Sureño #2 8-6 10-10 12-10 15-1 7-7 9-8 11-5 13-6
24 Pino Sureño #3 6-5 8-2 9-10 11-8 5-9 7-3 8-10 10-5
24 Abeto-Pino-Fir SS 9-2 12-1 15-5 18-9 9-2 12-1 15-0 17-5
24 Abeto-Pino-Fir #1 8-11 11-6 14-1 16-3 8-1 10-3 12-7 14-7
24 Abeto-Pino-Fir #2 8-11 11-6 14-1 16-3 8-1 10-3 12-7 14-7
24 Abeto-Pino-Fir #3 6-10 8-8 10-7 12-4 6-2 7-9 9-6 11-0
Para SI: 1 pulgada = 25.4 mm, 1 pie = 304.8 mm, 1 libra por pie cuadrado = 0.0479 kPa.
Nota: Verifique fuentes para disponibilidad de madera en longitudes mayores a 20 pies.

a las 11:14 AM (CDT) del 18 de julio de 2025 BAJO ESTE.

MADERA

TABLA 2308.8.2.1(2)—LUCES DE VIGAS DE PISO PARA ESPECIES COMUNES DE MADERA
(Áreas residenciales de estar, carga viva = 40 psf, L/Δ = 360)
Col2 Col3 Col4 Col5 Col6 Col7 Col8 Col9 Col10 Col11
ESPACIADO DE
VIGAS
(pulgadas)
ESPECIE Y GRADO ESPECIE Y GRADO CARGA MUERTA = 10 psf CARGA MUERTA = 10 psf CARGA MUERTA = 10 psf CARGA MUERTA = 10 psf CARGA MUERTA = 20 psf CARGA MUERTA = 20 psf CARGA MUERTA = 20 psf CARGA MUERTA = 20 psf
ESPACIADO DE
VIGAS
(pulgadas)
ESPECIE Y GRADO ESPECIE Y GRADO 2 × 6 2 × 8 2 × 10 2 × 12 2 × 6 2 × 8 2 × 10 2 × 12
ESPACIADO DE
VIGAS
(pulgadas)
ESPECIE Y GRADO ESPECIE Y GRADO Luces máximas de vigas de piso Luces máximas de vigas de piso Luces máximas de vigas de piso Luces máximas de vigas de piso Luces máximas de vigas de piso Luces máximas de vigas de piso Luces máximas de vigas de piso Luces máximas de vigas de piso
ESPACIADO DE
VIGAS
(pulgadas)
ESPECIE Y GRADO ESPECIE Y GRADO (pies - pulg.) (pies - pulg.) (pies - pulg.) (pies - pulg.) (pies - pulg.) (pies - pulg.) (pies - pulg.) (pies - pulg.)
12 Abeto Douglas-Lárice SS 11-4 15-0 19-1 23-3 11-4 15-0 19-1 23-3
12 Abeto Douglas-Lárice #1 10-11 14-5 18-5 22-0 10-11 14-2 17-4 20-1
12 Abeto Douglas-Lárice #2 10-9 14-2 17-9 20-7 10-6 13-3 16-3 18-10
12 Abeto Douglas-Lárice #3 8-8 11-0 13-5 15-7 7-11 10-0 12-3 14-3
12 Hem-Fir SS 10-9 14-2 18-0 21-11 10-9 14-2 18-0 21-11
12 Hem-Fir #1 10-6 13-10 17-8 21-6 10-6 13-10 16-11 19-7
12 Hem-Fir #2 10-0 13-2 16-10 20-4 10-0 13-1 16-0 18-6
12 Hem-Fir #3 8-8 11-0 13-5 15-7 7-11 10-0 12-3 14-3
12 Pino Sureño SS 11-2 14-8 18-9 22-10 11-2 14-8 18-9 22-10
12 Pino Sureño #1 10-9 14-2 18-0 21-11 10-9 14-2 16-11 20-1
12 Pino Sureño #2 10-3 13-6 16-2 19-1 9-10 12-6 14-9 17-5
12 Pino Sureño #3 8-2 10-3 12-6 14-9 7-5 9-5 11-5 13-6
12 Abeto-Pino-Fir SS 10-6 13-10 17-8 21-6 10-6 13-10 17-8 21-6
12 Abeto-Pino-Fir #1 10-3 13-6 17-3 20-7 10-3 13-3 16-3 18-10
12 Abeto-Pino-Fir #2 10-3 13-6 17-3 20-7 10-3 13-3 16-3 18-10
12 Abeto-Pino-Fir #3 8-8 11-0 13-5 15-7 7-11 10-0 12-3 14-3
16 Abeto Douglas-Lárice SS 10-4 13-7 17-4 21-1 10-4 13-7 17-4 21-0
16 Abeto Douglas-Lárice #1 9-11 13-1 16-5 19-1 9-8 12-4 15-0 17-5
16 Abeto Douglas-Lárice #2 9-9 12-7 15-5 17-10 9-1 11-6 14-1 16-3
16 Abeto Douglas-Lárice #3 7-6 9-6 11-8 13-6 6-10 8-8 10-7 12-4
16 Hem-Fir SS 9-9 12-10 16-5 19-11 9-9 12-10 16-5 19-11
16 Hem-Fir #1 9-6 12-7 16-0 18-7 9-6 12-0 14-8 17-0
16 Hem-Fir #2 9-1 12-0 15-2 17-7 8-11 11-4 13-10 16-1
16 Hem-Fir #3 7-6 9-6 11-8 13-6 6-10 8-8 10-7 12-4
16 Pino Sureño SS 10-2 13-4 17-0 20-9 10-2 13-4 17-0 20-9
16 Pino Sureño #1 9-9 12-10 16-1 19-1 9-9 12-7 14-8 17-5
16 Pino Sureño #2 9-4 11-10 14-0 16-6 8-6 10-10 12-10 15-1
16 Pino Sureño #3 7-1 8-11 10-10 12-10 6-5 8-2 9-10 11-8
16 Abeto-Pino-Fir SS 9-6 12-7 16-0 19-6 9-6 12-7 16-0 19-6
16 Abeto-Pino-Fir #1 9-4 12-3 15-5 17-10 9-1 11-6 14-1 16-3
16 Abeto-Pino-Fir #2 9-4 12-3 15-5 17-10 9-1 11-6 14-1 16-3
16 Abeto-Pino-Fir #3 7-6 9-6 11-8 13-6 6-10 8-8 10-7 12-4

23-40 CÓDIGO DE CONSTRUCCIÓN DE CALIFORNIA 2025

a las 11:14 AM (CDT) del 18 de julio de 2025 BAJO ESTE.

MADERA

TABLA 2308.8.2.1(2)—LUCES DE VIGAS DE PISO PARA ESPECIES COMUNES DE MADERA
(Áreas residenciales, carga viva = 40 psf, L/Δ = 360)—continuación
Col2 Col3 Col4 Col5 Col6 Col7 Col8 Col9 Col10 Col11
ESPACIADO DE VIGAS
(pulgadas)
ESPECIE Y GRADO ESPECIE Y GRADO CARGA MUERTA = 10 psf CARGA MUERTA = 10 psf CARGA MUERTA = 10 psf CARGA MUERTA = 10 psf CARGA MUERTA = 20 psf CARGA MUERTA = 20 psf CARGA MUERTA = 20 psf CARGA MUERTA = 20 psf
ESPACIADO DE VIGAS
(pulgadas)
ESPECIE Y GRADO ESPECIE Y GRADO 2 × 6 2 × 8 2 × 10 2 × 12 2 × 6 2 × 8 2 × 10 2 × 12
ESPACIADO DE VIGAS
(pulgadas)
ESPECIE Y GRADO ESPECIE Y GRADO Luz máxima de vigas de piso Luz máxima de vigas de piso Luz máxima de vigas de piso Luz máxima de vigas de piso Luz máxima de vigas de piso Luz máxima de vigas de piso Luz máxima de vigas de piso Luz máxima de vigas de piso
ESPACIADO DE VIGAS
(pulgadas)
ESPECIE Y GRADO ESPECIE Y GRADO (pies - pulgadas) (pies - pulgadas) (pies - pulgadas) (pies - pulgadas) (pies - pulgadas) (pies - pulgadas) (pies - pulgadas) (pies - pulgadas)
19.2 Douglas Fir-Larch SS 9-8 12-10 16-4 19-10 9-8 12-10 16-4 19-2
19.2 Douglas Fir-Larch #1 9-4 12-4 15-0 17-5 8-10 11-3 13-8 15-11
19.2 Douglas Fir-Larch #2 9-1 11-6 14-1 16-3 8-3 10-6 12-10 14-10
19.2 Douglas Fir-Larch #3 6-10 8-8 10-7 12-4 6-3 7-11 9-8 11-3
19.2 Hem-Fir SS 9-2 12-1 15-5 18-9 9-2 12-1 15-5 18-9
19.2 Hem-Fir #1 9-0 11-10 14-8 17-0 8-8 10-11 13-4 15-6
19.2 Hem-Fir #2 8-7 11-3 13-10 16-1 8-2 10-4 12-8 14-8
19.2 Hem-Fir #3 6-10 8-8 10-7 12-4 6-3 7-11 9-8 11-3
19.2 Southern Pine SS 9-6 12-7 16-0 19-6 9-6 12-7 16-0 19-6
19.2 Southern Pine #1 9-2 12-1 14-8 17-5 9-0 11-5 13-5 15-11
19.2 Southern Pine #2 8-6 10-10 12-10 15-1 7-9 9-10 11-8 13-9
19.2 Southern Pine #3 6-5 8-2 9-10 11-8 5-11 7-5 9-0 10-8
19.2 Spruce-Pine-Fir SS 9-0 11-10 15-1 18-4 9-0 11-10 15-1 17-9
19.2 Spruce-Pine-Fir # 8-9 11-6 14-1 16-3 8-3 10-6 12-10 14-10
19.2 Spruce-Pine-Fir #2 8-9 11-6 14-1 16-3 8-3 10-6 12-10 14-10
19.2 Spruce-Pine-Fir #3 6-10 8-8 10-7 12-4 6-3 7-11 9-8 11-3
24 Douglas Fir-Larch SS 9-0 11-11 15-2 18-5 9-0 11-11 14-9 17-1
24 Douglas Fir-Larch #1 8-8 11-0 13-5 15-7 7-11 10-0 12-3 14-3
24 Douglas Fir-Larch #2 8-1 10-3 12-7 14-7 7-5 9-5 11-6 13-4
24 Douglas Fir-Larch #3 6-2 7-9 9-6 11-0 5-7 7-1 8-8 10-1
24 Hem-Fir SS 8-6 11-3 14-4 17-5 8-6 11-3 14-4 16-10a
24 Hem-Fir #1 8-4 10-9 13-1 15-2 7-9 9-9 11-11 13-10
24 Hem-Fir #2 7-11 10-2 12-5 14-4 7-4 9-3 11-4 13-1
24 Hem-Fir #3 6-2 7-9 9-6 11-0 5-7 7-1 8-8 10-1
24 Southern Pine SS 8-10 11-8 14-11 18-1 8-10 11-8 14-11 18-0
24 Southern Pine #1 8-6 11-3 13-1 15-7 8-1 10-3 12-0 14-3
24 Southern Pine #2 7-7 9-8 11-5 13-6 7-0 8-10 10-5 12-4
24 Southern Pine #3 5-9 7-3 8-10 10-5 5-3 6-8 8-1 9-6
24 Spruce-Pine-Fir SS 8-4 11-0 14-0 17-0 8-4 11-0 13-8 15-11
24 Spruce-Pine-Fir #1 8-1 10-3 12-7 14-7 7-5 9-5 11-6 13-4
24 Spruce-Pine-Fir #2 8-1 10-3 12-7 14-7 7-5 9-5 11-6 13-4
24 Spruce-Pine-Fir #3 6-2 7-9 9-6 11-0 5-7 7-1 8-8 10-1
Para SI: 1 pulgada = 25.4 mm, 1 pie = 304.8 mm, 1 libra por pie cuadrado = 0.0479 kPa.
Nota: Verifique las fuentes para la disponibilidad de madera en longitudes mayores a 20 pies.
a. La longitud de apoyo en el extremo deberá aumentarse a 2 pulgadas.
Para SI: 1 pulgada = 25.4 mm, 1 pie = 304.8 mm, 1 libra por pie cuadrado = 0.0479 kPa.
Nota: Verifique las fuentes para la disponibilidad de madera en longitudes mayores a 20 pies.
a. La longitud de apoyo en el extremo deberá aumentarse a 2 pulgadas.
Para SI: 1 pulgada = 25.4 mm, 1 pie = 304.8 mm, 1 libra por pie cuadrado = 0.0479 kPa.
Nota: Verifique las fuentes para la disponibilidad de madera en longitudes mayores a 20 pies.
a. La longitud de apoyo en el extremo deberá aumentarse a 2 pulgadas.
Para SI: 1 pulgada = 25.4 mm, 1 pie = 304.8 mm, 1 libra por pie cuadrado = 0.0479 kPa.
Nota: Verifique las fuentes para la disponibilidad de madera en longitudes mayores a 20 pies.
a. La longitud de apoyo en el extremo deberá aumentarse a 2 pulgadas.
Para SI: 1 pulgada = 25.4 mm, 1 pie = 304.8 mm, 1 libra por pie cuadrado = 0.0479 kPa.
Nota: Verifique las fuentes para la disponibilidad de madera en longitudes mayores a 20 pies.
a. La longitud de apoyo en el extremo deberá aumentarse a 2 pulgadas.
Para SI: 1 pulgada = 25.4 mm, 1 pie = 304.8 mm, 1 libra por pie cuadrado = 0.0479 kPa.
Nota: Verifique las fuentes para la disponibilidad de madera en longitudes mayores a 20 pies.
a. La longitud de apoyo en el extremo deberá aumentarse a 2 pulgadas.
Para SI: 1 pulgada = 25.4 mm, 1 pie = 304.8 mm, 1 libra por pie cuadrado = 0.0479 kPa.
Nota: Verifique las fuentes para la disponibilidad de madera en longitudes mayores a 20 pies.
a. La longitud de apoyo en el extremo deberá aumentarse a 2 pulgadas.
Para SI: 1 pulgada = 25.4 mm, 1 pie = 304.8 mm, 1 libra por pie cuadrado = 0.0479 kPa.
Nota: Verifique las fuentes para la disponibilidad de madera en longitudes mayores a 20 pies.
a. La longitud de apoyo en el extremo deberá aumentarse a 2 pulgadas.
Para SI: 1 pulgada = 25.4 mm, 1 pie = 304.8 mm, 1 libra por pie cuadrado = 0.0479 kPa.
Nota: Verifique las fuentes para la disponibilidad de madera en longitudes mayores a 20 pies.
a. La longitud de apoyo en el extremo deberá aumentarse a 2 pulgadas.
Para SI: 1 pulgada = 25.4 mm, 1 pie = 304.8 mm, 1 libra por pie cuadrado = 0.0479 kPa.
Nota: Verifique las fuentes para la disponibilidad de madera en longitudes mayores a 20 pies.
a. La longitud de apoyo en el extremo deberá aumentarse a 2 pulgadas.

2308.8.2.2 Apoyo. Los extremos de cada viga deberán tener no menos de 1 1/2 pulgadas (38 mm) de apoyo sobre madera o metal, o no menos de 3 pulgadas (76 mm) sobre mampostería, excepto cuando estén apoyados sobre una tira de listón de 1 pulgada por 4 pulgadas (25 mm por 102 mm) y clavados al montante adyacente.

2308.8.2.3 Detalles de la estructura. Las vigas deberán estar soportadas lateralmente en los extremos y en cada apoyo mediante bloqueos sólidos, excepto cuando los extremos de las vigas estén clavados a una cabecera, banda o viga de borde o a un montante adyacente o por otros medios. El bloqueo sólido deberá tener un espesor no menor a 2 pulgadas (51 mm) y la profundidad total de la viga. Las vigas que se estructuren desde lados opuestos de una viga principal, cercha o tabique deberán traslaparse no menos de 3 pulgadas (76 mm) o las vigas opuestas deberán estar unidas entre sí de manera aprobada. Las vigas que se estructuren en el costado de una viga de madera deberán estar soportadas por anclajes estructurales o sobre listones de apoyo no menores a 2 pulgadas por 2 pulgadas (51 mm por 51 mm).

2308.8.3 Productos de madera estructurada. Los productos de madera estructurada deberán instalarse conforme a las recomendaciones del fabricante. No se permiten cortes, muescas ni perforaciones en cerchas, madera compuesta estructural, miembros laminados encolados estructurales o vigas en I, excepto cuando estén permitidos por las recomendaciones del fabricante o cuando los efectos de tales alteraciones se consideren específicamente en el diseño del miembro por un profesional registrado en diseño.

2308.8.4 Estructura alrededor de aberturas. Las vigas de refuerzo y cabecera deberán ser dobles, o de madera con sección transversal equivalente, cuando la luz de la cabecera exceda 4 pies (1219 mm). Los extremos de las vigas de cabecera de más de 6 pies (1829 mm) de longitud deberán estar soportados por anclajes estructurales o colgadores de vigas, a menos que apoyen sobre una viga, tabique o muro. Las vigas cola de más de 12 pies (3658 mm) de longitud deberán estar soportadas en la cabecera por anclajes estructurales o sobre listones de apoyo no menores a 2 pulgadas por 2 pulgadas (51 mm por 51 mm).

2308.8.4.1 Aberturas en diafragmas de piso en Categorías de Diseño Sísmico B, C, D y E. Las aberturas en diafragmas horizontales en Categorías de Diseño Sísmico B, C, D y E con una dimensión mayor a 4 pies (1219 mm) deberán construirse con ataduras metálicas y bloqueos conforme a esta sección y la Figura 2308.8.4.1(1). Las ataduras metálicas deberán tener un espesor no menor a 0.058 pulgadas [1.47 mm (calibre galvanizado 16)] por 1 1/2 pulgadas (38 mm) de ancho y deberán tener un esfuerzo de fluencia no menor a 33,000 psi (227 MPa). El bloqueo deberá extenderse no menos que la dimensión de la abertura en la dirección de la atadura y el bloqueo. Las ataduras deberán fijarse al bloqueo conforme a las instrucciones del fabricante, pero con no menos de ocho clavos comunes 16d en cada lado de la intersección cabecera-viga.

Las aberturas en diafragmas de piso en Categorías de Diseño Sísmico D y E no deberán tener ninguna dimensión que exceda el 50 por ciento de la distancia entre líneas de muros arriostrados ni un área mayor al 25 por ciento del área entre pares ortogonales de líneas de muros arriostrados [ver Figura 2308.8.4.1(2)]; o la porción de la estructura que contiene la abertura deberá diseñarse conforme a prácticas de ingeniería aceptadas para resistir las fuerzas especificadas en el Capítulo 16, en la medida en que dicha abertura irregular afecte el desempeño del sistema estructural convencional.

FIGURA 2308.8.4.1(1)—ABERTURAS EN DIAFRAGMAS DE PISO Y TECHO

FIGURA 2308.8.4.1(2)—LIMITACIONES DE ABERTURAS PARA DIAFRAGMAS DE PISO Y TECHO

23-42 CÓDIGO DE CONSTRUCCIÓN DE CALIFORNIA 2025

2308.8.4.2 Desplazamientos verticales en diafragmas de piso en Categorías de Diseño Sísmico D y E. En Categorías de Diseño Sísmico D y E, las porciones de un nivel de piso no deberán estar desplazadas verticalmente de tal manera que los miembros estructurales a cada lado del desplazamiento no puedan traslaparse o unirse de manera aprobada conforme a la Figura 2308.8.4.2, a menos que la porción de la estructura que contiene el desplazamiento irregular esté diseñada conforme a prácticas de ingeniería aceptadas.

Excepción: La estructura soportada directamente por cimientos no necesita traslaparse ni unirse directamente.

VIGAS DE PISO

NO PUEDEN

UNIRSE

DIRECTAMENTE

DESPLAZAMIENTO DE NIVEL DE PISO VERTICALMENTE Col3
GAS
SE
CTAMENTE
R
GAS
SE
CTAMENTE
R
GAS
SE
CTAMENTE
R
GAS
SE
CTAMENTE
R

VISTA EN SECCIÓN VISTA EN SECCIÓN

2308.8.5 Vigas que soportan tabiques portantes. Los tabiques portantes paralelos a las vigas deberán estar soportados sobre vigas principales, cerchas, vigas dobles, muros u otros tabiques portantes. Los tabiques portantes perpendiculares a las vigas no deberán estar desplazados de vigas principales, muros o tabiques soportantes más que la profundidad de la viga, a menos que dichas vigas sean de tamaño suficiente para soportar la carga adicional.

2308.8.6 Soporte lateral. La estructura de piso y techo con una relación nominal de profundidad a espesor no menor a 5 a 1 deberá tener un borde alineado durante todo el vano. Cuando la relación nominal de profundidad a espesor del miembro estructural exceda 6 a 1, deberá haber una línea de riostras por cada 8 pies (2438 mm) de vano, a menos que ambos bordes del miembro estén alineados. Las riostras deberán consistir en madera no menor a 1 pulgada por 3 pulgadas (25 mm por 76 mm), clavada doblemente en cada extremo, o un refuerzo metálico equivalente de igual rigidez, bloqueo sólido de profundidad completa u otro medio aprobado. Se requerirá una línea de riostras en los apoyos donde no se proporcione soporte lateral equivalente por otros medios.

2308.8.7 Entablado estructural de piso. El entablado estructural de piso deberá cumplir con las disposiciones de la Sección 2304.8.1.

2308.8.8 Ventilación bajo piso. Para ventilación bajo piso, ver Sección 1202.4.

2308.8.9 Estructura de piso que soporta paneles de muro arriostrado. Cuando los paneles de muro arriostrado estén soportados por pisos en voladizo o estén desplazados del soporte de la viga de piso, la estructura del piso deberá cumplir con la Sección 2308.10.7.

2308.8.10 Anclaje de componentes exteriores de medios de evacuación en Categorías de Diseño Sísmico D y E. Los balcones de evacuación exteriores, escaleras exteriores, rampas y componentes similares de medios de evacuación en estructuras asignadas a Categorías de Diseño Sísmico D o E deberán estar anclados positivamente a la estructura primaria a no más de 8 pies (2438 mm) en el centro o deberán diseñarse para fuerzas laterales. Dicha fijación no deberá realizarse mediante clavos en ángulo (toenails) ni clavos susceptibles a extracción.

2308.9 Construcción de muros.

2308.9 Construcción de muros. Los muros de construcción convencional de armazón ligero deberán cumplir con esta sección.

2308.9.1 Tamaño, altura y separación de los montantes. El tamaño, la altura y la separación de los montantes deberán cumplir con la Tabla 2308.9.1.

Los montantes deberán ser continuos desde un soporte en la placa de base hasta un soporte en la placa superior para resistir cargas perpendiculares al muro. El soporte deberá ser una cimentación o piso, diafragma de techo o techo, o deberá diseñarse conforme a la práctica de ingeniería aceptada.

Excepción: Montantes de refuerzo, montantes recortadores y montantes cortos en aberturas en muros que cumplan con la Tabla 2308.8.1.1(1) o 2308.8.1.1(2).

TABLA 2308.9.1—TAMAÑO, ALTURA Y SEPARACIÓN DE MONTANTES DE MADERA Col2 Col3 Col4 Col5 Col6 Col7
TAMAÑO DEL MONTANTE
(pulgadas)
MUROS DE CARGA MUROS DE CARGA MUROS DE CARGA MUROS DE CARGA MUROS SIN CARGA MUROS SIN CARGA
TAMAÑO DEL MONTANTE
(pulgadas)
Altura del montante sin soporte laterala
(pies)
Soporta solo techo y cielo raso Soporta un piso, techo y cielo raso Soporta dos pisos, techo y cielo raso Altura del montante sin soporte laterala
(pies)
Separación
(pulgadas)
TAMAÑO DEL MONTANTE
(pulgadas)
Altura del montante sin soporte laterala
(pies)
Separación (pulgadas) Separación (pulgadas) Separación (pulgadas) Separación (pulgadas) Separación (pulgadas)
2 × 3b 10 16
2 × 4 10 24 16 14 24
3 × 4 10 24 24 16 14 24
2 × 5 10 24 24 16 24
2 × 6 10 24 24 16 20 24
Para SI: 1 pulgada = 25.4 mm, 1 pie = 304.8 mm.
a. Las alturas listadas son distancias entre puntos de soporte lateral colocados perpendicularmente al plano del muro. Se permiten incrementos en la altura sin soporte cuando se justifique mediante un análisis.
b. No se deben usar en muros exteriores.
c. Los montantes de grado utilitario no deben espaciarse más de 16 pulgadas en centro ni soportar más que un techo y cielo raso, ni exceder 8 pies de altura para muros exteriores y muros de carga o 10 pies para muros interiores sin carga.
Para SI: 1 pulgada = 25.4 mm, 1 pie = 304.8 mm.
a. Las alturas listadas son distancias entre puntos de soporte lateral colocados perpendicularmente al plano del muro. Se permiten incrementos en la altura sin soporte cuando se justifique mediante un análisis.
b. No se deben usar en muros exteriores.
c. Los montantes de grado utilitario no deben espaciarse más de 16 pulgadas en centro ni soportar más que un techo y cielo raso, ni exceder 8 pies de altura para muros exteriores y muros de carga o 10 pies para muros interiores sin carga.
Para SI: 1 pulgada = 25.4 mm, 1 pie = 304.8 mm.
a. Las alturas listadas son distancias entre puntos de soporte lateral colocados perpendicularmente al plano del muro. Se permiten incrementos en la altura sin soporte cuando se justifique mediante un análisis.
b. No se deben usar en muros exteriores.
c. Los montantes de grado utilitario no deben espaciarse más de 16 pulgadas en centro ni soportar más que un techo y cielo raso, ni exceder 8 pies de altura para muros exteriores y muros de carga o 10 pies para muros interiores sin carga.
Para SI: 1 pulgada = 25.4 mm, 1 pie = 304.8 mm.
a. Las alturas listadas son distancias entre puntos de soporte lateral colocados perpendicularmente al plano del muro. Se permiten incrementos en la altura sin soporte cuando se justifique mediante un análisis.
b. No se deben usar en muros exteriores.
c. Los montantes de grado utilitario no deben espaciarse más de 16 pulgadas en centro ni soportar más que un techo y cielo raso, ni exceder 8 pies de altura para muros exteriores y muros de carga o 10 pies para muros interiores sin carga.
Para SI: 1 pulgada = 25.4 mm, 1 pie = 304.8 mm.
a. Las alturas listadas son distancias entre puntos de soporte lateral colocados perpendicularmente al plano del muro. Se permiten incrementos en la altura sin soporte cuando se justifique mediante un análisis.
b. No se deben usar en muros exteriores.
c. Los montantes de grado utilitario no deben espaciarse más de 16 pulgadas en centro ni soportar más que un techo y cielo raso, ni exceder 8 pies de altura para muros exteriores y muros de carga o 10 pies para muros interiores sin carga.
Para SI: 1 pulgada = 25.4 mm, 1 pie = 304.8 mm.
a. Las alturas listadas son distancias entre puntos de soporte lateral colocados perpendicularmente al plano del muro. Se permiten incrementos en la altura sin soporte cuando se justifique mediante un análisis.
b. No se deben usar en muros exteriores.
c. Los montantes de grado utilitario no deben espaciarse más de 16 pulgadas en centro ni soportar más que un techo y cielo raso, ni exceder 8 pies de altura para muros exteriores y muros de carga o 10 pies para muros interiores sin carga.
Para SI: 1 pulgada = 25.4 mm, 1 pie = 304.8 mm.
a. Las alturas listadas son distancias entre puntos de soporte lateral colocados perpendicularmente al plano del muro. Se permiten incrementos en la altura sin soporte cuando se justifique mediante un análisis.
b. No se deben usar en muros exteriores.
c. Los montantes de grado utilitario no deben espaciarse más de 16 pulgadas en centro ni soportar más que un techo y cielo raso, ni exceder 8 pies de altura para muros exteriores y muros de carga o 10 pies para muros interiores sin carga.

2308.9.2 Detalles del armazón. Los montantes deberán colocarse con su dimensión ancha perpendicular al muro. No se instalarán menos de tres montantes en cada esquina de un muro exterior.

Excepciones:

  1. En muros interiores sin carga y tabiques, se permite colocar los montantes con la dimensión larga paralela al muro.
  2. En las esquinas se permiten dos montantes, siempre que se usen separadores de madera o refuerzos de respaldo de panel estructural de madera de 3/8 de pulgada (9.5 mm) de espesor, tablero de partículas tipo M “Exterior Glue” de 3/8 de pulgada (9.5 mm), madera de 1 pulgada (25 mm) de espesor u otros dispositivos aprobados que sirvan como respaldo adecuado para la fijación de materiales de revestimiento. Cuando se requieran clasificaciones de resistencia al fuego o valores de corte, no se deben usar separadores, refuerzos o dispositivos a menos que estén específicamente aprobados para tal uso.

2308.9.3 Placas y zócalos. Los montantes deberán tener placas y zócalos conforme a esta sección.

2308.9.3.1 Placa o zócalo inferior. Los montantes deberán tener apoyo total sobre una placa o zócalo. Las placas o zócalos deberán tener un espesor nominal no menor a 2 pulgadas (51 mm) y un ancho no menor al ancho de los montantes del muro.

2308.9.3.2 Placas superiores. Los montantes de muros de carga y exteriores deberán estar rematados con placas superiores dobles instaladas para proporcionar traslapes en las esquinas y en las intersecciones con otras particiones. Las juntas finales en las placas superiores dobles deberán estar desplazadas no menos de 48 pulgadas (1219 mm) y clavadas conforme a la Tabla 2304.10.2. Las placas deberán tener una profundidad nominal de 2 pulgadas (51 mm) y un ancho no menor al ancho de los montantes.

Excepción: Se permite una sola placa superior, siempre que la placa esté adecuadamente amarrada en las esquinas y muros intersectantes con no menos del equivalente a una placa de acero galvanizado de 3 pulgadas por 6 pulgadas (76 mm por 152 mm) y 0.036 pulgadas (0.914 mm) de espesor, clavada a cada muro o segmento de muro con seis clavos tipo 8d [2 1/2 pulgadas por 0.113 pulgadas (64 mm por 2.87 mm)] o equivalente en cada lado de la junta. Para la unión a tope entre placas superiores simples adyacentes, se requerirá no menos del equivalente a una placa de acero galvanizado de 3 pulgadas por 12 pulgadas (76 mm por 304 mm) y 0.036 pulgadas (0.914 mm) de espesor, clavada a cada muro o segmento de muro con 12 clavos tipo 8d [2 1/2 pulgadas por 0.113 pulgadas (64 mm por 2.87 mm)] en cada lado de la junta, siempre que las vigas, viguetas o cerchas estén centradas sobre los montantes con una tolerancia no mayor a 1 pulgada (25 mm). No se requerirá placa superior sobre dinteles que estén en el mismo plano y alineados con la superficie superior de las placas superiores adyacentes y estén amarrados a secciones de muro adyacentes como se requiere para la unión a tope entre placas superiores simples adyacentes.

Cuando los montantes de carga estén espaciados a intervalos de 24 pulgadas (610 mm), las placas superiores sean menos que dos miembros de 2 pulgadas por 6 pulgadas (51 mm por 152 mm) o dos miembros de 3 pulgadas por 4 pulgadas (76 mm por 102 mm) y las vigas del piso, cerchas del piso o cerchas del techo que soportan estén espaciadas a más de 16 pulgadas (406 mm), dichas vigas o cerchas deberán apoyar dentro de 5 pulgadas (127 mm) de los montantes debajo o se deberá instalar una tercera placa.

2308.9.4 Muros y tabiques sin carga. En muros y tabiques sin carga que no formen parte de un panel de muro arriostrado, los montantes deberán espaciarse no más de 24 pulgadas (610 mm) en centro. En muros y tabiques interiores sin carga, se permite colocar los montantes con la dimensión larga paralela al muro. Cuando los montantes se coloquen con la dimensión larga paralela al muro, no se permite el uso de madera de grado utilitario ni montantes que excedan los 10 pies (3048 mm). Los tabiques interiores sin carga deberán estar rematados con no menos de una placa superior instalada para proporcionar traslapes en las esquinas y en las intersecciones con otros muros y tabiques. La placa deberá estar amarrada continuamente en las juntas mediante bloqueos sólidos no menores a 16 pulgadas (406 mm) de longitud y del mismo tamaño que la placa o mediante ataduras metálicas de 1/2 pulgada por 1 1/2 pulgadas (12.7 mm por 38 mm) con secciones empalmadas sujetas con dos clavos 16d en cada lado de la junta.

2308.9.5 Aberturas en muros y tabiques. Las aberturas en muros y tabiques exteriores e interiores deberán cumplir con las Secciones 2308.9.5.1 a 2308.9.5.3.

2308.9.5.1 Aberturas en muros exteriores de carga. Se deberán proveer dinteles sobre cada abertura en muros exteriores de carga. Se permite usar los tamaños y luces de la Tabla 2308.8.1.1(1) para viviendas unifamiliares y bifamiliares. Los dinteles para otros edificios deberán diseñarse conforme a la Sección 2302.1, Ítem 1 o 2. Se permiten dinteles de dos o más piezas de madera estructural nominal de 2 pulgadas (51 mm) colocadas de canto conforme a la Tabla 2308.8.1.1(1) y clavadas juntas conforme a la Tabla 2304.10.2 o de madera maciza de tamaño equivalente.

Los dinteles de miembro único con un espesor nominal de 2 pulgadas (51 mm) deberán enmarcarse con un miembro plano único nominal de 2 pulgadas (51 mm) o placa de muro no menor en ancho que los montantes en la parte superior e inferior del dintel conforme a las Figuras 2308.9.5.1(1) y 2308.9.5.1(2) y clavarse de cara en la parte superior e inferior del dintel con clavos tipo 10d [3 pulgadas × 0.128 pulgadas (76 mm × 3.3 mm)] espaciados a 12 pulgadas (305 mm) en centro.

Los montantes del muro deberán soportar los extremos del dintel conforme a la Tabla 2308.8.1.1(1). Cada extremo de un dintel o lintel deberá tener una longitud de apoyo no menor a 1 1/2 pulgadas (38 mm) para todo el ancho del lintel.

FIGURA 2308.9.5.1(1)—DINTEL DE MIEMBRO ÚNICO EN MURO EXTERIOR DE CARGA

PLACA SUPERIOR

MONTANTE CORTO

CONEXIÓN DE PLACA A DINTEL

CONFORME A LA

SECCIÓN 2308.9.5.1

MONTANTE DE REFUERZO

23-44 CÓDIGO DE CONSTRUCCIÓN DE CALIFORNIA 2025

FIGURA 2308.9.5.1(2)—DINTEL ALTERNATIVO DE MIEMBRO ÚNICO SIN MONTANTE CORTO

PLACA SUPERIOR

CONEXIÓN DE PLACA A DINTEL

CONFORME A LA

SECCIÓN 2308.9.5.1

MONTANTE DE REFUERZO

2308.9.5.2 Aberturas en tabiques interiores de carga. Se deberán proveer dinteles sobre cada abertura en tabiques interiores de carga como se requiere en la Sección 2308.9.5.1. Se permite usar las luces de la Tabla 2308.8.1.1(2). Los montantes del muro deberán soportar los extremos del dintel conforme a la Tabla 2308.8.1.1(1) o 2308.8.1.1(2), según corresponda.

2308.9.5.3 Aberturas en tabiques interiores sin carga. Se permite enmarcar aberturas en tabiques sin carga con montantes y dinteles simples. Cada extremo de un lintel o dintel deberá tener una longitud de apoyo no menor a 1 1/2 pulgadas (38 mm) para todo el ancho del lintel.

2308.9.6 Muros cortos (cripple walls). Los muros cortos de cimentación deberán enmarcarse con montantes no menores al tamaño de los montantes superiores. Los montantes de muros cortos exteriores deberán tener una longitud no menor a 14 pulgadas (356 mm) o deberán enmarcarse con bloqueos sólidos. Cuando excedan 4 pies (1219 mm) de altura, dichos muros deberán enmarcarse con montantes del tamaño requerido para un piso adicional. Véase la Sección 2308.10.6 para el arriostramiento de muros cortos.

2308.9.7 Refuerzos transversales (bridging). A menos que estén cubiertos por revestimientos interiores o exteriores o entablados que cumplan con los requisitos mínimos de este código, las particiones o muros con montantes que tengan una relación altura a espesor menor que exceda 50 deberán tener refuerzos transversales de no menos de 2 pulgadas (51 mm) de espesor y del mismo ancho que los montantes, ajustados y clavados para proporcionar soporte lateral adecuado. Los refuerzos deberán colocarse en cada cavidad de montante y con una frecuencia tal que los montantes así arriostrados no tengan una relación altura a espesor menor que exceda 50, midiendo la altura del montante entre el armazón horizontal y el refuerzo o entre refuerzos, lo que sea mayor.

2308.9.8 Tuberías en muros. Las particiones con tuberías de plomería, calefacción u otras deberán enmarcarse y las vigas debajo deberán espaciarse para proporcionar el espacio adecuado para las tuberías. Cuando una partición con tuberías corre paralela a las vigas del piso, las vigas debajo de dichas particiones deberán duplicarse y espaciarse para permitir el paso de tuberías y deberán estar arriostradas. Cuando se coloquen tuberías de plomería, calefacción u otras en, o parcialmente en, una partición, que requiera cortar las placas o zócalos, se deberá sujetar una atadura metálica no menor a 0.058 pulgadas (1.47 mm) (calibre galvanizado 16) y 1 1/2 pulgadas (38 mm) de ancho a cada placa a través y a cada lado de la abertura con no menos de seis clavos 16d.

2308.9.9 Entablado exterior de muros. Excepto cuando se instale construcción de estuco que cumpla con la Sección 2510, el exterior de los muros exteriores, incluyendo frontones, de edificios cerrados deberá estar entablado con uno de los materiales de espesor nominal especificado en la Tabla 2308.9.9 con sujetadores conforme a los requisitos de la Sección 2304.10 o sujetadores diseñados conforme a la práctica de ingeniería aceptada. Alternativamente, se permitirán materiales de entablado y sujetadores que cumplan con la Sección 2304.6.

TABLA 2308.9.9—ESPESOR MÍNIMO DEL ENTABLADO DE MUROS Col2 Col3
TIPO DE ENTABLADO ESPESOR MÍNIMO SEPARACIÓN MÁXIMA DE MONTANTES
Tablas diagonales de madera 5/8 de pulgada 24 pulgadas en centro
Tablero estructural de fibra 1/2 pulgada 16 pulgadas en centro
Panel estructural de madera De acuerdo con
las Tablas 2308.10.3(2) y 2308.10.3(3)
Tablero de partículas M-S “Exterior Glue” y M-2 “Exterior Glue” De acuerdo con
la Sección 2306.3 y la Tabla 2308.10.3(4)
Entablado de yeso 1/2 pulgada 16 pulgadas en centro
Mortero reforzado con cemento 1 pulgada 24 pulgadas en centro
Revestimiento de panel de tablero duro De acuerdo con la Tabla 2308.10.3(5)
Para SI: 1 pulgada = 25.4 mm. Para SI: 1 pulgada = 25.4 mm. Para SI: 1 pulgada = 25.4 mm.

2308.10 Refuerzo de muros.

2308.10 Refuerzo de muros. Los edificios deberán contar con líneas de muros reforzados exteriores e interiores según se describe en las Secciones 2308.10.1 a 2308.10.10.2.

MADERA

2308.10.1 Líneas de muros reforzados. Para determinar la cantidad y ubicación del refuerzo requerido a lo largo de cada nivel de un edificio, las líneas de muros reforzados se designarán como líneas rectas a través del plano del edificio en ambas direcciones, longitudinal y transversal, y se colocarán conforme a la Tabla 2308.10.1 y la Figura 2308.10.1. El espaciamiento entre líneas de muros reforzados no deberá exceder la distancia especificada en la Tabla 2308.10.1. En estructuras asignadas a la Categoría de Diseño Sísmico D o E, las líneas de muros reforzados deberán intersectarse perpendicularmente entre sí.

FIGURA 2308.10.1—COMPONENTES BÁSICOS DEL SISTEMA DE REFUERZO LATERAL

Para SI: 1 pie = 304.8 mm.

23-46 CÓDIGO DE CONSTRUCCIÓN DE CALIFORNIA 2025

MADERA

TABLA 2308.10.1—REQUISITOS DE REFUERZO DE MUROSa Col2 Col3 Col4 Col5 Col6 Col7
CATEGORÍA DE DISEÑO
SÍSMICO
CONDICIÓN DEL PISO
(VER SECCIÓN 2308.2)
ESPACIADO MÁXIMO DE
LÍNEAS DE MUROS
REFORZADOS
UBICACIÓN DEL PANEL REFORZADO,
ESPACIADO (C.C.) Y PORCENTAJE MÍNIMO (X)
UBICACIÓN DEL PANEL REFORZADO,
ESPACIADO (C.C.) Y PORCENTAJE MÍNIMO (X)
UBICACIÓN DEL PANEL REFORZADO,
ESPACIADO (C.C.) Y PORCENTAJE MÍNIMO (X)
DISTANCIA MÁXIMA
DE LOS PANELES DE MURO
REFORZADO DESDE CADA
EXTREMO DE LA LÍNEA
DE MURO REFORZADO
CATEGORÍA DE DISEÑO
SÍSMICO
CONDICIÓN DEL PISO
(VER SECCIÓN 2308.2)
ESPACIADO MÁXIMO DE
LÍNEAS DE MUROS
REFORZADOS
Método de refuerzob Método de refuerzob Método de refuerzob Método de refuerzob
CATEGORÍA DE DISEÑO
SÍSMICO
CONDICIÓN DEL PISO
(VER SECCIÓN 2308.2)
ESPACIADO MÁXIMO DE
LÍNEAS DE MUROS
REFORZADOS
LIB DWB, WSP SFB, PBS, PCP, HPS, GBc, d SFB, PBS, PCP, HPS, GBc, d
A y B 35′ - 0″ Cada extremo y
≤ 25′- 0″ c.c.
Cada extremo y
≤ 25′- 0″ c.c.
Cada extremo y
≤ 25′- 0″ c.c.
12′- 6″
A y B 35′- 0″ Cada extremo y
≤ 25′- 0″ c.c.
Cada extremo y
≤ 25′- 0″ c.c.
Cada extremo y
≤ 25′- 0″ c.c.
12′- 6″
A y B 35′- 0″ NP Cada extremo y
≤ 25′- 0″ c.c.
Cada extremo y
≤ 25′- 0″ c.c.
12′- 6″
C 35′- 0″ NP Cada extremo y
≤ 25′- 0″ c.c.
Cada extremo y
≤ 25′- 0″ c.c.
12′- 6″
C 35′- 0″ NP Cada extremo y
≤ 25′- 0″ c.c.
(mínimo 25% de
la longitud del muro)e
Cada extremo y
≤ 25′- 0″ c.c.
(mínimo 25% de la
longitud del muro)e
12′- 6″
D y E 25′- 0″ NP SDS < 0.50: Cada extremo
y ≤ 25′- 0″ c.c.
(mínimo 21% de
la longitud del muro)e
SDS < 0.50: Cada extremo y ≤
25′- 0″ c.c. (mínimo
43% de la longitud del muro)e
8′- 0″
D y E 25′- 0″ NP 0.5 ≤SDS < 0.75: Cada
extremo y
≤ 25′- 0″ c.c.
(mínimo 32% de
la longitud del muro)e
0.5 ≤SDS< 0.75: Cada extremo
y ≤ 25′- 0″ c.c. (mínimo
59% de la longitud del muro)e
0.5 ≤SDS< 0.75: Cada extremo
y ≤ 25′- 0″ c.c. (mínimo
59% de la longitud del muro)e
D y E 25′- 0″ NP 0.75 ≤SDS ≤ 1.00:
Cada extremo y
≤ 25′- 0″ c.c.
(mínimo 37% de
la longitud del muro)e
0.75 ≤SDS ≤ 1.00: Cada extremo
y
≤ 25′- 0″ c.c.
(mínimo 75% de la
longitud del muro)
0.75 ≤SDS ≤ 1.00: Cada extremo
y
≤ 25′- 0″ c.c.
(mínimo 75% de la
longitud del muro)
D y E 25′- 0″ NP SDS > 1.00: Cada extremo
y ≤ 25′- 0″ c.c.
(mínimo 48% de
la longitud del muro)e
SDS > 1.00: Cada extremo y ≤
25′- 0″ c.c. (mínimo
100% de la longitud del muro)e
SDS > 1.00: Cada extremo y ≤
25′- 0″ c.c. (mínimo
100% de la longitud del muro)e
Para SI: 1 pulgada = 25.4 mm, 1 pie = 304.8 mm.
NP = No Permitido.
a.
Esta tabla especifica los requisitos mínimos para paneles de muro reforzado a lo largo de líneas de muros reforzados interiores o exteriores.
b.
Ver Sección 2308.10.3 para descripción completa de los métodos de refuerzo.
c.
Para el Método GB, tablero de yeso aplicado a soportes de estructura espaciados a 16 pulgadas en centro.
d.
Las longitudes requeridas se duplicarán para tablero de yeso aplicado solo a una cara del panel de muro reforzado.
e.
El porcentaje mostrado representa la cantidad mínima de refuerzo requerida a lo largo de la longitud del edificio (o longitud del muro si la estructura tiene forma irregular).
Para SI: 1 pulgada = 25.4 mm, 1 pie = 304.8 mm.
NP = No Permitido.
a.
Esta tabla especifica los requisitos mínimos para paneles de muro reforzado a lo largo de líneas de muros reforzados interiores o exteriores.
b.
Ver Sección 2308.10.3 para descripción completa de los métodos de refuerzo.
c.
Para el Método GB, tablero de yeso aplicado a soportes de estructura espaciados a 16 pulgadas en centro.
d.
Las longitudes requeridas se duplicarán para tablero de yeso aplicado solo a una cara del panel de muro reforzado.
e.
El porcentaje mostrado representa la cantidad mínima de refuerzo requerida a lo largo de la longitud del edificio (o longitud del muro si la estructura tiene forma irregular).
Para SI: 1 pulgada = 25.4 mm, 1 pie = 304.8 mm.
NP = No Permitido.
a.
Esta tabla especifica los requisitos mínimos para paneles de muro reforzado a lo largo de líneas de muros reforzados interiores o exteriores.
b.
Ver Sección 2308.10.3 para descripción completa de los métodos de refuerzo.
c.
Para el Método GB, tablero de yeso aplicado a soportes de estructura espaciados a 16 pulgadas en centro.
d.
Las longitudes requeridas se duplicarán para tablero de yeso aplicado solo a una cara del panel de muro reforzado.
e.
El porcentaje mostrado representa la cantidad mínima de refuerzo requerida a lo largo de la longitud del edificio (o longitud del muro si la estructura tiene forma irregular).
Para SI: 1 pulgada = 25.4 mm, 1 pie = 304.8 mm.
NP = No Permitido.
a.
Esta tabla especifica los requisitos mínimos para paneles de muro reforzado a lo largo de líneas de muros reforzados interiores o exteriores.
b.
Ver Sección 2308.10.3 para descripción completa de los métodos de refuerzo.
c.
Para el Método GB, tablero de yeso aplicado a soportes de estructura espaciados a 16 pulgadas en centro.
d.
Las longitudes requeridas se duplicarán para tablero de yeso aplicado solo a una cara del panel de muro reforzado.
e.
El porcentaje mostrado representa la cantidad mínima de refuerzo requerida a lo largo de la longitud del edificio (o longitud del muro si la estructura tiene forma irregular).
Para SI: 1 pulgada = 25.4 mm, 1 pie = 304.8 mm.
NP = No Permitido.
a.
Esta tabla especifica los requisitos mínimos para paneles de muro reforzado a lo largo de líneas de muros reforzados interiores o exteriores.
b.
Ver Sección 2308.10.3 para descripción completa de los métodos de refuerzo.
c.
Para el Método GB, tablero de yeso aplicado a soportes de estructura espaciados a 16 pulgadas en centro.
d.
Las longitudes requeridas se duplicarán para tablero de yeso aplicado solo a una cara del panel de muro reforzado.
e.
El porcentaje mostrado representa la cantidad mínima de refuerzo requerida a lo largo de la longitud del edificio (o longitud del muro si la estructura tiene forma irregular).
Para SI: 1 pulgada = 25.4 mm, 1 pie = 304.8 mm.
NP = No Permitido.
a.
Esta tabla especifica los requisitos mínimos para paneles de muro reforzado a lo largo de líneas de muros reforzados interiores o exteriores.
b.
Ver Sección 2308.10.3 para descripción completa de los métodos de refuerzo.
c.
Para el Método GB, tablero de yeso aplicado a soportes de estructura espaciados a 16 pulgadas en centro.
d.
Las longitudes requeridas se duplicarán para tablero de yeso aplicado solo a una cara del panel de muro reforzado.
e.
El porcentaje mostrado representa la cantidad mínima de refuerzo requerida a lo largo de la longitud del edificio (o longitud del muro si la estructura tiene forma irregular).

2308.10.2 Paneles de muro reforzado. Los paneles de muro reforzado se colocarán a lo largo de las líneas de muros reforzados conforme a la Tabla 2308.10.1 y la Figura 2308.10.1 y según se especifica en la Tabla 2308.10.3(1). Un panel de muro reforzado deberá ubicarse en cada extremo de la línea de muro reforzado y en las esquinas de líneas de muros reforzados que se intersectan o deberá comenzar dentro de la distancia máxima desde el extremo de la línea de muro reforzado conforme a la Tabla 2308.10.1. Los paneles de muro reforzado en una línea de muro reforzado no deberán desplazarse entre sí más de 4 pies (1219 mm). Los paneles de muro reforzado deberán estar claramente indicados en los planos.

2308.10.3 Métodos para paneles de muro reforzado. La construcción de paneles de muro reforzado se realizará mediante uno o una combinación de los métodos indicados en la Tabla 2308.10.3(1). La longitud del panel de muro reforzado deberá cumplir con lo establecido en la Sección 2308.10.4 o 2308.10.5.

MADERA

TABLA 2308.10.3(1)—MÉTODOS DE REFUERZO Col2 Col3 Col4 Col5
MÉTODOS,
MATERIAL
ESPESOR MÍNIMO FIGURA CRITERIOS DE CONEXIÓNa CRITERIOS DE CONEXIÓNa
MÉTODOS,
MATERIAL
ESPESOR MÍNIMO FIGURA Sujetadores Espaciamiento
LIBa
Refuerzo embebido
Madera 1″ × 4″ o tiras metálicas aprobadas
fijadas en ángulos de 45° a 60° a los montantes
con máximo de 16″ c.c.
5 Tabla 2304.10.2 Madera: por montante más placas superior e inferior
LIBa
Refuerzo embebido
Madera 1″ × 4″ o tiras metálicas aprobadas
fijadas en ángulos de 45° a 60° a los montantes
con máximo de 16″ c.c.
5 Tira metálica: instalada conforme a las
recomendaciones del fabricante
Tira metálica: instalada conforme a las
recomendaciones del fabricante
DWB
Tablas diagonales de
madera
3/4″ de espesor (1″ nominal) × 6″
ancho mínimo a montantes
con máximo de 24″ c.c.
Tabla 2304.10.2 Por montante
WSP
Panel estructural
de madera
3/8″ conforme a
Tabla 2308.10.3(2) o
2308.10.3(3)
Tabla 2304.10.2 6″ bordes 12″ campo
SFB
Revestimiento de tablero
fibroso estructural
1/2″ conforme a
Tabla 2304.10.2 a montantes
con máximo 16″ c.c.
Tabla 2304.10.2 3″ bordes 6″ campo
GB
Tablero de yeso
(doble cara)
1/2″ o 5/8″ de no menos de
4′ de ancho a montantes con máximo
de 24” c.c.
Sección 2506.2 para revestimiento exterior
e interior: clavos cooler 5d (15/8″ × 0.086″) o
tornillos 11/4″ (Tipo W o S) para tablero de yeso 1/2″ o tornillos 15/8″ (Tipo W o S) para tablero de yeso 5/8″
Para todas las ubicaciones de paneles de muro reforzado: 7″ c.c. a lo largo de los bordes del panel (incluyendo placas superior e inferior) y 7” c.c. en el campo
PBS
Revestimiento de tablero
aglomerado
3/8″ o 1/2″ conforme
a Tabla 2308.10.3(4) a montantes
con máximo de 16″ c.c.
Clavos comunes 6d (2″ largo × 0.113″
diámetro) para revestimiento de 3/8″ o clavos comunes 8d (21/2″ largo × 0.131″ diámetro) para revestimiento de 1/2″
3″ bordes 6″ campo
PCP
Revoque de cemento
Portland
Sección 2510 a montantes con
máximo de 16″ c.c.
Clavos de 11/2″ de largo, calibre 11,
0.120" diámetro,
cabeza 7/16″, o grapas de 7/8″ de largo, calibre 16
6″ c.c. en todos los miembros de la estructura
HPS
Revestimiento de panel
de tablero duro
7/16″ conforme a
Tabla 2308.10.3(5)
Tabla 2304.10.2 4″ bordes 8″ campo
ABW
Muro reforzado
alternativo
3/8″ Figura 2308.10.5.1 y
Sección 2308.10.5.1
Figura 2308.10.5.1
PFH
Estructura de pórtico con
sujetadores de anclaje
3/8″ Figura 2308.10.5.2 y
Sección 2308.10.5.2
Figura 2308.10.5.2
Para SI: 1 pie = 304.8 mm, 1 grado = 0.01745 rad.
a. El método LIB debe tener tablero de yeso fijado a uno o más lados con clavos o tornillos.
Para SI: 1 pie = 304.8 mm, 1 grado = 0.01745 rad.
a. El método LIB debe tener tablero de yeso fijado a uno o más lados con clavos o tornillos.
Para SI: 1 pie = 304.8 mm, 1 grado = 0.01745 rad.
a. El método LIB debe tener tablero de yeso fijado a uno o más lados con clavos o tornillos.
Para SI: 1 pie = 304.8 mm, 1 grado = 0.01745 rad.
a. El método LIB debe tener tablero de yeso fijado a uno o más lados con clavos o tornillos.
Para SI: 1 pie = 304.8 mm, 1 grado = 0.01745 rad.
a. El método LIB debe tener tablero de yeso fijado a uno o más lados con clavos o tornillos.

23-48 CÓDIGO DE CONSTRUCCIÓN DE CALIFORNIA 2025

MADERA

TABLA 2308.10.3(2)—REVESTIMIENTO EXPUESTO DE PANEL DE CONTRACHAPADO Col2 Col3
ESPESOR MÍNIMoa
(pulgadas)
NÚMERO MÍNIMO DE CAPAS ESPACIADO DE MONTANTES
(pulgadas) Revestimiento de contrachapado aplicado directamente a montantes o sobre revestimiento
3/8 3 16b
1/2 4 24
Para SI: 1 pulgada = 25.4 mm.
a. El espesor de los paneles ranurados se mide en el fondo de las ranuras.
b. Se permiten luces de 24 pulgadas si el revestimiento de contrachapado se aplica con la veta perpendicular a los montantes o sobre uno de los siguientes: revestimiento de tablas de 1 pulgada; revestimiento de panel estructural de madera de 7/16 pulgadas; o revestimiento de panel estructural de madera de 3/8 pulgadas con eje de resistencia (que es la dirección larga del panel salvo indicación contraria) perpendicular a los montantes.
Para SI: 1 pulgada = 25.4 mm.
a. El espesor de los paneles ranurados se mide en el fondo de las ranuras.
b. Se permiten luces de 24 pulgadas si el revestimiento de contrachapado se aplica con la veta perpendicular a los montantes o sobre uno de los siguientes: revestimiento de tablas de 1 pulgada; revestimiento de panel estructural de madera de 7/16 pulgadas; o revestimiento de panel estructural de madera de 3/8 pulgadas con eje de resistencia (que es la dirección larga del panel salvo indicación contraria) perpendicular a los montantes.
Para SI: 1 pulgada = 25.4 mm.
a. El espesor de los paneles ranurados se mide en el fondo de las ranuras.
b. Se permiten luces de 24 pulgadas si el revestimiento de contrachapado se aplica con la veta perpendicular a los montantes o sobre uno de los siguientes: revestimiento de tablas de 1 pulgada; revestimiento de panel estructural de madera de 7/16 pulgadas; o revestimiento de panel estructural de madera de 3/8 pulgadas con eje de resistencia (que es la dirección larga del panel salvo indicación contraria) perpendicular a los montantes.
TABLA 2308.10.3(3)—REVESTIMIENTO DE MURO CON PANEL ESTRUCTURAL DE MADERAb
(No expuesto a la intemperie, eje de resistencia paralelo o perpendicular a montantes excepto indicación contraria)
Col2 Col3 Col4 Col5
ESPESOR MÍNIMO
(pulgadas)
CLASIFICACIÓN DE LUZ DEL PANEL ESPACIADO DE MONTANTES (pulgadas) ESPACIADO DE MONTANTES (pulgadas) ESPACIADO DE MONTANTES (pulgadas)
ESPESOR MÍNIMO
(pulgadas)
CLASIFICACIÓN DE LUZ DEL PANEL Revestimiento clavado a montantes Revestimiento clavable Revestimiento clavable
ESPESOR MÍNIMO
(pulgadas)
CLASIFICACIÓN DE LUZ DEL PANEL Revestimiento clavado a montantes Revestimiento
paralelo a montantes
Revestimiento
perpendicular a montantes
3/8, 15/32, 1/2 16/0, 20/0, 24/0,
32/16 Muro—24″ c.c.
24 16 24
7/16, 15/32, 1/2 24/0, 24/16,
32/16 Muro—24″ c.c.
24 24a 24
Para SI: 1 pulgada = 25.4 mm.
a. El contrachapado debe consistir en cuatro o más capas.
b. No se requiere bloqueo de juntas horizontales excepto según se especifica en la Sección 2308.10.4.
Para SI: 1 pulgada = 25.4 mm.
a. El contrachapado debe consistir en cuatro o más capas.
b. No se requiere bloqueo de juntas horizontales excepto según se especifica en la Sección 2308.10.4.
Para SI: 1 pulgada = 25.4 mm.
a. El contrachapado debe consistir en cuatro o más capas.
b. No se requiere bloqueo de juntas horizontales excepto según se especifica en la Sección 2308.10.4.
Para SI: 1 pulgada = 25.4 mm.
a. El contrachapado debe consistir en cuatro o más capas.
b. No se requiere bloqueo de juntas horizontales excepto según se especifica en la Sección 2308.10.4.
Para SI: 1 pulgada = 25.4 mm.
a. El contrachapado debe consistir en cuatro o más capas.
b. No se requiere bloqueo de juntas horizontales excepto según se especifica en la Sección 2308.10.4.
TABLA 2308.10.3(4)—LUCES PERMITIDAS PARA REVESTIMIENTO DE MURO DE TABLERO AGLUTINADO
(No expuesto a la intemperie, dimensión larga del panel paralela o perpendicular a montantes)
Col2 Col3 Col4
GRADO ESPESOR
(pulgadas)
ESPACIADO DE MONTANTES (pulgadas) ESPACIADO DE MONTANTES (pulgadas)
GRADO ESPESOR
(pulgadas)
Revestimiento clavado a montantes Revestimiento bajo cubiertas especificadas en
Sección 2308.10.3 paralelo o perpendicular a montantes
M-S “Pegamento Exterior” y
M-2 “Pegamento Exterior”
3/8 16
M-S “Pegamento Exterior” y
M-2 “Pegamento Exterior”
1/2 16 16
Para SI: 1 pulgada = 25.4 mm. Para SI: 1 pulgada = 25.4 mm. Para SI: 1 pulgada = 25.4 mm. Para SI: 1 pulgada = 25.4 mm.
TABLA 2308.10.3(5)—REVESTIMIENTO DE TABLERO DURO Col2 Col3 Col4 Col5 Col6
REVESTIMIENTO ESPESOR NOMINAL MÍNIMO
(pulgadas)
ESPACIADO MÁXIMO DE ESTRUCTURA 2 × 4 TAMAÑO DE CLAVOa, b, d ESPACIADO DE CLAVOS ESPACIADO DE CLAVOS
REVESTIMIENTO ESPESOR NOMINAL MÍNIMO
(pulgadas)
ESPACIADO MÁXIMO DE ESTRUCTURA 2 × 4 TAMAÑO DE CLAVOa, b, d General Paneles de refuerzoc
1. Revestimiento solapado 1. Revestimiento solapado 1. Revestimiento solapado 1. Revestimiento solapado 1. Revestimiento solapado 1. Revestimiento solapado
Directo a montantes 3/8 16″ c.c. 8d 16″ c.c. No aplicable
Sobre revestimiento 3/8 16″ c.c. 10d 16″ c.c. No aplicable
2. Revestimiento de panel con borde cuadrado 2. Revestimiento de panel con borde cuadrado 2. Revestimiento de panel con borde cuadrado 2. Revestimiento de panel con borde cuadrado 2. Revestimiento de panel con borde cuadrado 2. Revestimiento de panel con borde cuadrado
Directo a montantes 3/8 24″ c.c. 6d 6″ c.c. bordes; 12″ c.c. en
soportes intermedios
4″ c.c. bordes; 8″ c.c. en
soportes intermedios
Sobre revestimiento 3/8 24″ c.c. 8d 6″ c.c. bordes; 12″ c.c. en
soportes intermedios
4″ c.c. bordes; 8″ c.c. en
soportes intermedios
3. Revestimiento de panel con borde machihembrado 3. Revestimiento de panel con borde machihembrado 3. Revestimiento de panel con borde machihembrado 3. Revestimiento de panel con borde machihembrado 3. Revestimiento de panel con borde machihembrado 3. Revestimiento de panel con borde machihembrado
Directo a montantes 3/8 16″ c.c. 6d 6″ c.c. bordes; 12″ c.c. en
soportes intermedios
4″ c.c. bordes; 8″ c.c. en
soportes intermedios
Sobre revestimiento 3/8 16″ c.c. 8d 6″ c.c. bordes; 12″ c.c. en
soportes intermedios
4″ c.c. bordes; 8″ c.c. en
soportes intermedios
Para SI: 1 pulgada = 25.4 mm.
a. Los clavos deben ser resistentes a la corrosión.
b. Dimensiones mínimas aceptables de clavos.
Revestimiento de panel (pulgadas)
Revestimiento solapado (pulgadas)
Diámetro del vástago
0.092
0.099
Diámetro de la cabeza
0.225
0.240
c. Cuando se usa para cumplir con la Sección 2308.10.
d. La longitud del clavo debe acomodar el revestimiento y penetrar la estructura 1 1/2 pulgadas.
Para SI: 1 pulgada = 25.4 mm.
a. Los clavos deben ser resistentes a la corrosión.
b. Dimensiones mínimas aceptables de clavos.
Revestimiento de panel (pulgadas)
Revestimiento solapado (pulgadas)
Diámetro del vástago
0.092
0.099
Diámetro de la cabeza
0.225
0.240
c. Cuando se usa para cumplir con la Sección 2308.10.
d. La longitud del clavo debe acomodar el revestimiento y penetrar la estructura 1 1/2 pulgadas.
Para SI: 1 pulgada = 25.4 mm.
a. Los clavos deben ser resistentes a la corrosión.
b. Dimensiones mínimas aceptables de clavos.
Revestimiento de panel (pulgadas)
Revestimiento solapado (pulgadas)
Diámetro del vástago
0.092
0.099
Diámetro de la cabeza
0.225
0.240
c. Cuando se usa para cumplir con la Sección 2308.10.
d. La longitud del clavo debe acomodar el revestimiento y penetrar la estructura 1 1/2 pulgadas.
Para SI: 1 pulgada = 25.4 mm.
a. Los clavos deben ser resistentes a la corrosión.
b. Dimensiones mínimas aceptables de clavos.
Revestimiento de panel (pulgadas)
Revestimiento solapado (pulgadas)
Diámetro del vástago
0.092
0.099
Diámetro de la cabeza
0.225
0.240
c. Cuando se usa para cumplir con la Sección 2308.10.
d. La longitud del clavo debe acomodar el revestimiento y penetrar la estructura 1 1/2 pulgadas.
Para SI: 1 pulgada = 25.4 mm.
a. Los clavos deben ser resistentes a la corrosión.
b. Dimensiones mínimas aceptables de clavos.
Revestimiento de panel (pulgadas)
Revestimiento solapado (pulgadas)
Diámetro del vástago
0.092
0.099
Diámetro de la cabeza
0.225
0.240
c. Cuando se usa para cumplir con la Sección 2308.10.
d. La longitud del clavo debe acomodar el revestimiento y penetrar la estructura 1 1/2 pulgadas.
Col1 Revestimiento de panel (pulgadas) Revestimiento solapado (pulgadas)
Diámetro del vástago 0.092 0.099
Diámetro de la cabeza 0.225 0.240

2308.10.4 Construcción de paneles de muro reforzado. Para los Métodos DWB, WSP, SFB, PBS, PCP y HPS, cada panel debe tener una longitud no menor a 48 pulgadas (1219 mm), cubriendo tres espacios entre montantes cuando los montantes estén espaciados a 16 pulgadas (406 mm) en centro y cubriendo dos espacios entre montantes cuando estén espaciados a 24 pulgadas (610 mm) en centro. Los paneles de muro reforzado con longitud menor a 48 pulgadas (1219 mm) no contribuirán a la cantidad de refuerzo requerida. Los paneles de muro reforzado que sean más largos que la longitud requerida se acreditarán por su longitud real. Para el Método GB, cada panel debe tener una longitud no menor a 96 pulgadas (2438 mm) cuando se aplique a un solo lado de los montantes o 48 pulgadas (1219 mm) cuando se aplique a ambos lados.

Las juntas verticales del revestimiento del panel deberán coincidir con los montantes y las juntas adyacentes de panel deberán clavarse a miembros comunes de la estructura. Las juntas horizontales deberán coincidir con bloqueos u otra estructura de tamaño igual a los montantes, excepto cuando los requisitos de instalación para los materiales específicos de revestimiento eximan esta condición. Las placas de base deberán clavarse a la estructura del piso conforme a la Sección 2308.10.7 y las placas superiores deberán conectarse a la estructura superior conforme a la Sección 2308.10.7.2. Cuando las vigas estén perpendiculares a las líneas de muros reforzados superiores, se deberá proveer bloqueo debajo y en línea con los paneles de muro reforzado.

2308.10.5 Refuerzo alternativo. Se permite sustituir un panel de muro reforzado de 48 pulgadas (1219 mm) del Método DWB, WSP, SFB, PBS, PCP o HPS por un muro reforzado alternativo (ABW) o una estructura de pórtico con sujetadores de anclaje (PFH) descritos en esta sección. Para el Método GB, cada sección de 96 pulgadas (2438 mm) (aplicada a una cara) o de 48 pulgadas (1219 mm) (aplicada a ambas caras) o fracción requerida por la Tabla 2308.10.1 podrá ser reemplazada por un panel construido conforme al Método ABW o PFH.

2308.10.5.1 Muro contravente alternativo (ABW). Un ABW se construirá de acuerdo con esta sección y la Figura 2308.10.5.1. En edificios de un solo piso, cada panel tendrá una longitud no menor de 2 pies 8 pulgadas (813 mm) y una altura no mayor de 10 pies (3048 mm). Cada panel estará revestido en una cara con un tablero estructural de madera de espesor mínimo de [3] / 8 de pulgada (3.2 mm) clavado con clavos comunes de 8d o clavos galvanizados de caja conforme a la Tabla 2304.10.2 y bloqueado en los bordes del tablero estructural de madera. Se proporcionarán dos pernos de anclaje instalados conforme a la Sección 2308.7.1 en cada panel. Los pernos de anclaje se colocarán en los puntos exteriores de un cuarto de la longitud de cada panel. El montante final de cada panel tendrá un dispositivo de sujeción (hold-down) fijado a la cimentación, capaz de proporcionar una capacidad aprobada de elevación no menor de 1,800 libras (8006 N). El dispositivo de sujeción se instalará conforme a las recomendaciones del fabricante. El ABW se apoyará directamente sobre una cimentación o sobre una estructura de piso apoyada directamente sobre una cimentación continua a lo largo de toda la línea del muro contravente. Esta cimentación se reforzará con no menos de una barra No. 4 en la parte superior e inferior. Cuando la cimentación continua requiera una profundidad mayor a 12 pulgadas (305 mm), se permitirá una zapata continua o borde de losa invertida mínimo de 12 pulgadas por 12 pulgadas (305 mm por 305 mm) en las aberturas de puertas en la línea del muro contravente. Esta zapata continua o borde de losa invertida se reforzará con no menos de una barra No. 4 en la parte superior e inferior. Este refuerzo se traslapará 15 pulgadas (381 mm) con el refuerzo requerido en la cimentación continua ubicada directamente debajo de la línea del muro contravente.

Cuando el ABW se instale en el primer piso de edificios de dos pisos, el tablero estructural de madera se proporcionará en ambas caras, se colocarán tres pernos de anclaje en los puntos de un cuarto y la capacidad de elevación del dispositivo de sujeción será no menor de 3,000 libras (13 344 N).

FIGURA 2308.10.5.1—PANEL DE MURO CONTRAVENTE ALTERNATIVO (ABW)

PANEL MÍNIMO DE 2 ′ -8 ″

PARA EMPALME DE PANEL (SI ES NECESARIO) LOS BORDES DE LOS PANELES ADYACENTES DEBEN ENCONTRARSE SOBRE Y ESTAR FIJADOS A LA ESTRUCTURA COMÚN

CLAVOS COMUNES DE 8d O GALVANIZADOS DE CAJA A 6 ″ EN CENTRO EN LOS BORDES DEL PANEL PARA UN SOLO PISO Y A 4 ″ EN CENTRO EN LOS BORDES DEL PANEL PARA EL PRIMER PISO DE 2 PISOS

PERNOS DE ANCLAJE SEGÚN SECCIÓN 2308.10.5.1

REFUERZO MÍNIMO DE LA CIMENTACIÓN, UNA BARRA #4 ARRIBA Y ABAJO DE LA ZAPATA. EL REFUERZO DEBE TRASLAPARSE MÍNIMO 15 PULGADAS.

Para SI: 1 pulgada = 25.4 mm, 1 pie = 304.8 mm.

Col1 Col2 Col3 Col4 Col5 Col6 Col7 Col8

2308.10.5.2 Marco portal con dispositivos de sujeción (PFH). Un PFH se construirá conforme a esta sección y la Figura 2308.10.5.2. La abertura adyacente de puerta o ventana tendrá un dintel de longitud completa.

En edificios de un solo piso, cada panel tendrá una longitud no menor de 16 pulgadas (406 mm) y una altura no mayor de 10 pies (3048 mm). Cada panel estará revestido en una cara con una sola capa de tablero estructural de madera de espesor mínimo de [3] / 8 de pulgada (9.5 mm) clavado con clavos comunes de 8d o clavos galvanizados de caja conforme a la Figura 2308.10.5.2. El tablero estructural de madera se extenderá sobre el dintel macizo aserrado o laminado encolado y se clavará conforme a la

23-50 CÓDIGO DE CONSTRUCCIÓN DE CALIFORNIA 2025

el 18 de julio de 2025 11:14 AM (CDT) SEGÚN LO DISPUESTO.

MADERA

Figura 2308.10.5.2. Se permitirá el uso de un dintel compuesto formado por no menos de dos tablas de 2 pulgadas por 12 pulgadas (51 mm por 305 mm), fijadas conforme al Ítem 24 de la Tabla 2304.10.2. Si se usa un espaciador, este se colocará en el lado opuesto al tablero estructural de madera del dintel compuesto. El dintel se extenderá entre las caras interiores de los primeros montantes exteriores de longitud completa de cada panel. El vano libre del dintel entre los montantes interiores de cada panel será no menor de 6 pies (1829 mm) y no mayor de 18 pies (5486 mm). Una correa con una capacidad de elevación no menor de 1,000 libras (4,400 N) sujetará el dintel a los montantes interiores opuestos al revestimiento. Se proporcionará un perno de anclaje de no menos de [5] / 8 de pulgada (15.9 mm) de diámetro instalado conforme a la Sección 2308.7.1 en el centro de cada placa de umbral. Los montantes en cada extremo del panel tendrán un dispositivo de sujeción fijado a la cimentación con una capacidad de elevación no menor de 3,500 libras (15 570 N).

Cuando un panel esté ubicado a un lado de la abertura, el dintel se extenderá entre la cara interior del primer montante de longitud completa del panel y los montantes de apoyo en el otro extremo de la abertura. Una correa con una capacidad de elevación no menor de 1,000 libras (4400 N) sujetará el dintel a los montantes de apoyo. Los montantes de apoyo tendrán un dispositivo de sujeción fijado a la cimentación con una capacidad de elevación no menor de 1,000 libras (4400 N). Los dispositivos de sujeción serán del tipo correa embebida, instalados conforme a las recomendaciones del fabricante. Los paneles PFH se apoyarán directamente sobre una cimentación continua a lo largo de toda la línea del muro contravente. Esta cimentación se reforzará con no menos de una barra No. 4 en la parte superior e inferior. Cuando la cimentación continua requiera una profundidad mayor a 12 pulgadas (305 mm), se permitirá una zapata continua o borde de losa invertida mínimo de 12 pulgadas por 12 pulgadas (305 mm por 305 mm) en las aberturas de puertas en la línea del muro contravente. Esta zapata continua o borde de losa invertida se reforzará con no menos de una barra No. 4 en la parte superior e inferior. Este refuerzo se traslapará no menos de 15 pulgadas (381 mm) con el refuerzo requerido en la cimentación continua ubicada directamente debajo de la línea del muro contravente.

Cuando un PFH se instale en el primer piso de edificios de dos pisos, cada panel tendrá una longitud no menor de 24 pulgadas (610 mm).

FIGURA 2308.10.5.2—MARCO PORTAL CON DISPOSITIVOS DE SUJECIÓN (PFH)

Para SI: 1 pulgada = 25.4 mm, 1 pie = 304.8 mm, 1 libra = 4.448 N.

2308.10.6 Refuerzo de muro corto (cripple wall). Los muros cortos se reforzarán conforme a la Sección 2308.10.6.1 o 2308.10.6.2.

2308.10.6.1 Refuerzo de muro corto en Categorías de Diseño Sísmico A, B y C. Para los fines de esta sección, los muros cortos en Categorías de Diseño Sísmico A, B y C con una altura de montante que exceda 14 pulgadas (356 mm) se considerarán un piso y se reforzarán conforme a la Tabla 2308.10.1. El espaciamiento de los clavos en los bordes para el refuerzo requerido de muros cortos no excederá 6 pulgadas (152 mm) en centro a lo largo de la placa de cimentación y la placa superior del muro corto. El tamaño de clavo, el espaciamiento para clavado en obra y los requisitos más restrictivos para clavado en los bordes serán los requeridos en otras partes del código para el material de refuerzo específico utilizado.

2308.10.6.2 Refuerzo de muro corto en Categorías de Diseño Sísmico D y E. Para los fines de esta sección, los muros cortos en Categorías de Diseño Sísmico D y E no tendrán una altura de montante que exceda 14 pulgadas (356 mm), y los montantes serán bloqueados sólidamente conforme a la Sección 2308.9.6 para todo el perímetro de la vivienda y para toda la longitud de las líneas de muros contravente interiores apoyados en cimentaciones, exceptuando las aberturas para ventilación y acceso.

el 18 de julio de 2025 11:14 AM (CDT) SEGÚN LO DISPUESTO.

MADERA

2308.10.7 Conexiones de paneles de muro contravente. Las uniones de paneles de muro contravente deberán ubicarse sobre montantes o bloqueos. Los paneles de muro contravente se fijarán a montantes, placas superior e inferior y en los bordes de los paneles. Los paneles de muro contravente se aplicarán a estructuras de montantes nominales de 2 pulgadas de ancho [realmente de 1 [1] / 2 pulgada (38 mm)] o mayores.

2308.10.7.1 Conexión de placa inferior. Las placas inferiores de la línea de muro contravente se conectarán a las vigas o bloqueos de profundidad completa debajo conforme a la Tabla 2304.10.2, o a cimentaciones conforme a la Sección 2308.10.7.3.

2308.10.7.2 Conexión de placa superior. Cuando se usen vigas o cabios, las placas superiores de la línea de muro contravente se fijarán a lo largo de toda la línea de muro contravente a vigas, cabios, tableros de borde o bloqueos de profundidad completa arriba conforme a la Tabla 2304.10.2, según corresponda, basado en la orientación de las vigas o cabios respecto a la línea de muro contravente. Los bloqueos tendrán un espesor nominal no menor de 2 pulgadas (51 mm) y se fijarán a la placa superior de la línea de muro contravente según lo especificado en la Tabla 2304.10.2. Se permitirá el entallado o perforación de agujeros en los bloqueos conforme a los requisitos de la Sección 2308.6 o 2308.11.4.

En muros exteriores de hastiales, el revestimiento de panel de muro contravente en el último piso se extenderá y fijará a la estructura del techo cuando la distancia entre líneas paralelas exteriores de muro contravente sea mayor a 50 pies (15 240 mm).

Cuando se usen cerchas de techo instaladas perpendicularmente a una línea exterior de muro contravente, las fuerzas laterales se transferirán del diafragma del techo al muro contravente a lo largo de toda la línea del muro contravente mediante bloqueos en los extremos de las cerchas u otros métodos aprobados que proporcionen transferencia equivalente de fuerzas laterales. Los bloqueos tendrán un espesor nominal no menor de 2 pulgadas (51 mm) y serán iguales a la profundidad de la cercha en la línea del muro y se fijarán a la placa superior de la línea de muro contravente según lo especificado en la Tabla 2304.10.2. Se permitirá el entallado o perforación de agujeros en los bloqueos conforme a los requisitos de la Sección 2308.6 o 2308.11.4.

Excepción: Cuando el revestimiento del techo esté a más de 9 [1] / 4 pulgadas (235 mm) sobre la placa superior, no se requiere bloqueo sólido cuando los miembros estructurales estén conectados usando uno de los siguientes métodos:

  1. Conforme a la Figura 2308.10.7.2(1).
  2. Conforme a la Figura 2308.10.7.2(2).
  3. Paneles de bloqueo de altura completa diseñados para valores listados en AWC WFCM.
  4. Un diseño conforme a métodos de ingeniería aceptados.

FIGURA 2308.10.7.2(1)—CONEXIÓN DE PLACA SUPERIOR DE LÍNEA DE MURO CONTRAVENTE

Para SI: 1 pie = 304.8 mm. a. Los métodos de refuerzo serán los descritos en la Tabla 2308.10.3(1) DWB, WSP, SFB, GB, PBS, PCP o HPS.

23-52 CÓDIGO DE CONSTRUCCIÓN DE CALIFORNIA 2025

el 18 de julio de 2025 11:14 AM (CDT) SEGÚN LO DISPUESTO.

MADERA

FIGURA 2308.10.7.2(2)—CONEXIÓN DE PLACA SUPERIOR DE PANEL DE MURO CONTRAVENTE

Para SI: 1 pie = 304.8 mm. a. Los métodos de refuerzo serán los descritos en la Tabla 2308.10.3(1) DWB, WSP, SFB, GB, PBS, PCP o HPS.

2308.10.7.3 Anclaje de umbral. Cuando se requieran cimentaciones conforme a la Sección 2308.10.8, los umbrales de la línea de muro contravente se anclarán a cimentaciones de concreto o mampostería. Dicho anclaje cumplirá con los requisitos de la Sección 2308.7. Los anclajes se distribuirán a lo largo de la longitud de la línea de muro contravente. Se permiten otros dispositivos de anclaje con capacidad equivalente.

2308.10.7.4 Anclaje a cimentaciones totalmente de madera. Cuando se usen cimentaciones totalmente de madera, la transferencia de fuerzas desde las líneas de muro contravente se determinará mediante cálculo y tendrá una capacidad no menor que las conexiones requeridas por la Sección 2308.7.

2308.10.8 Soporte de línea de muro contravente y diafragma. Las líneas de muro contravente y los diafragmas de piso y techo se soportarán conforme a esta sección.

2308.10.8.1 Requisitos de cimentación. Las líneas de muro contravente se soportarán mediante cimentaciones continuas.

Excepción: Para estructuras con una dimensión máxima en planta no mayor a 50 pies (15 240 mm), se requieren cimentaciones continuas solo en muros exteriores.

Para estructuras en Categorías de Diseño Sísmico D y E, los paneles exteriores de muro contravente estarán en el mismo plano vertical que la cimentación o la porción de la estructura que contenga el desplazamiento se diseñará conforme a la práctica de ingeniería aceptada y la Sección 2308.3.

Excepciones:

  1. Se permitirá que los paneles exteriores de muro contravente estén ubicados a no más de 4 pies (1219 mm) de la cimentación inferior cuando estén soportados por un piso construido conforme a todos los siguientes: 1.1. Los voladizos o retrocesos no excederán cuatro veces la profundidad nominal de las vigas del piso. 1.2. Las vigas del piso serán de 2 pulgadas por 10 pulgadas (51 mm por 254 mm) o mayores y espaciadas no más de 16 pulgadas (406 mm) en centro. 1.3. La relación del vano trasero al voladizo será no menor que 2 a 1. 1.4. Las vigas en los extremos de los paneles de muro contravente serán dobles. 1.5. Un tablero de borde continuo se conectará a los extremos de las vigas voladizas. Se permite empalmar el tablero de borde usando una correa metálica no menor de 0.058 pulgada (1.47 mm) (calibre galvanizado 16) y 1 [1] / 2 pulgadas (38 mm) de ancho fijada con seis clavos comunes de 16d a cada lado. La correa metálica tendrá un límite elástico no menor de 33,000 psi (227 MPa). 1.6. Las vigas en retrocesos o en el extremo de vigas voladizas no soportarán cargas gravitacionales de más de un solo piso con cargas uniformes de muro y techo ni las reacciones de dinteles con un vano de 8 pies (2438 mm) o más.
  2. Se permitirá que el extremo de un panel de muro contravente requerido se extienda no más de 1 pie (305 mm) sobre una abertura en el muro inferior. Este requisito aplica a paneles de muro contravente desplazados en el plano y a paneles desplazados fuera de plano según lo permitido por la Excepción 1. Se permite que los paneles de muro contravente se extiendan sobre una abertura no mayor a 8 pies (2438 mm) de ancho cuando el dintel sea un elemento de 4 pulgadas por 12 pulgadas (102 mm por 305 mm) o mayor.

el 18 de julio de 2025 11:14 AM (CDT) SEGÚN LO DISPUESTO.

MADERA

2308.10.8.2 Soporte de diafragma de piso y techo en Categorías de Diseño Sísmico D y E. En estructuras asignadas a Categorías de Diseño Sísmico D o E, los diafragmas de piso y techo serán soportados lateralmente por líneas de muro contravente en todos los bordes y conectados conforme a la Sección 2308.10.7 [ver Figura 2308.10.8.2(1)].

Excepción: Se permite que porciones de techos o pisos que no soporten paneles de muro contravente arriba se extiendan hasta 6 pies (1829 mm) más allá de una línea de muro contravente [ver Figura 2308.10.8.2(2)] siempre que los miembros estructurales estén conectados a la línea de muro contravente inferior conforme a la Sección 2308.10.7.

FIGURA 2308.10.8.2(1)—TECHO EN SDC D O E NO SOPORTADO EN TODOS LOS BORDES

FIGURA 2308.10.8.2(2)—EXTENSIÓN DE TECHO EN SDC D O E MÁS ALLÁ DE LÍNEA DE MURO CONTRAVENTE

Para SI: 1 pie = 304.8 mm.

2308.10.8.3 Zapatas escalonadas en Categorías de Diseño Sísmico B, C, D y E. En Categorías de Diseño Sísmico B, C, D y E, cuando la altura de un panel de muro contravente requerido que se extiende desde la cimentación hasta el piso superior varíe más de 4 pies (1219 mm), se usará la siguiente construcción:

  1. Cuando la base de la zapata esté escalonada y la estructura del piso más bajo repose directamente sobre un umbral atornillado a las zapatas, el umbral se anclará según lo requerido en la Sección 2308.7.
  2. Cuando la estructura del piso más bajo repose directamente sobre un umbral atornillado a una zapata de no menos de 8 pies (2438 mm) de longitud a lo largo de una línea de refuerzo, la línea se considerará reforzada. La doble placa del muro corto más allá del segmento de zapata que se extiende hasta el piso enmarcado más bajo se empalmará con la placa de umbral mediante correas metálicas, una a cada lado del umbral y la placa. Las correas metálicas tendrán no menos de 0.058 pulgada [1.47 mm (calibre galvanizado 16)] por 1 [1] / 2 pulgadas (38 mm) de ancho por 48 pulgadas (1219 mm) con ocho clavos comunes de 16d a cada lado de la ubicación del empalme (ver Figura 2308.10.8.3). La correa metálica tendrá un límite elástico no menor de 33,000 psi (227 MPa).
  3. Cuando existan muros cortos entre la parte superior de la zapata y la estructura del piso más bajo, se aplicarán los requisitos de refuerzo para un piso.

23-54 CÓDIGO DE CONSTRUCCIÓN DE CALIFORNIA 2025

el 18 de julio de 2025 11:14 AM (CDT) SEGÚN LO DISPUESTO.

MADERA

FIGURA 2308.10.8.3—DETALLES DE CONEXIÓN DE ZAPATA ESCALONADA

Para SI: 1 pulgada = 25.4 mm, 1 pie = 304.8 mm.

2308.10.9 Fijación del revestimiento. La fijación del revestimiento de panel de muro contravente no será menor que la prescrita en las Tablas 2308.10.1 y 2304.10.2. El revestimiento de muro no se fijará a los miembros estructurales mediante adhesivos.

2308.10.10 Limitaciones del revestimiento de concreto o mampostería. El revestimiento de concreto o mampostería cumplirá con el Capítulo 14 y esta sección.

2308.10.10.1 Limitaciones del revestimiento de concreto o mampostería en Categorías de Diseño Sísmico B o C. En Categorías de Diseño Sísmico B y C, los muros de concreto o mampostería y el revestimiento de piedra o mampostería no se extenderán por encima de un sótano.

Excepciones:

  1. En estructuras asignadas a Categoría de Diseño Sísmico B, se permite usar revestimiento de piedra y mampostería en los dos primeros pisos sobre el plano de nivel o en los tres primeros pisos sobre el plano de nivel cuando el piso más bajo tenga muros de concreto o mampostería, siempre que se use refuerzo de muro con tablero estructural de madera y la longitud del refuerzo proporcionado sea una vez y media la longitud requerida especificada en la Tabla 2308.10.1.
  2. Se permite usar revestimiento de piedra y mampostería en el primer piso sobre el plano de nivel o en los dos primeros pisos sobre el plano de nivel cuando el piso más bajo tenga muros de concreto o mampostería.
  3. Se permite usar revestimiento de piedra y mampostería en ambos pisos de edificios con dos pisos sobre el plano de nivel, siempre que se cumplan los siguientes criterios: 3.1. El tipo de refuerzo conforme a la Sección 2308.10.1 será WSP y la capacidad permisible de corte conforme a la Sección 2306.3 será no menor de 350 plf (5108 N/m). 3.2. Los paneles de muro contravente en el segundo piso se ubicarán conforme a la Sección 2308.10.1 y no más de 25 pies (7620 mm) en centro, y la longitud total de paneles de muro contravente será no menor del 25 por ciento de la longitud de la línea de muro contravente. Los paneles de muro contravente en el primer piso se ubicarán conforme a la Sección 2308.10.1 y no más de 25 pies (7620 mm) en centro, y la longitud total de paneles de muro contravente será no menor del 45 por ciento de la longitud de la línea de muro contravente. 3.3. Se proporcionarán conectores de sujeción con una capacidad permisible de 2,000 libras (8896 N) en los extremos de cada panel de muro contravente para la conexión del segundo piso al primer piso. Se proporcionarán conectores de sujeción con una capacidad permisible de 3,900 libras (17 347 N) en los extremos de cada panel de muro contravente para la conexión del primer piso a la cimentación. En todos los casos, la fuerza del conector de sujeción se transferirá a la cimentación. 3.4. No se permitirán muros cortos.

2308.10.10.2 Limitaciones del revestimiento de concreto o mampostería en Categorías de Diseño Sísmico D y E. En Categorías de Diseño Sísmico D y E, los muros de concreto o mampostería y el revestimiento de piedra o mampostería no se extenderán por encima de un sótano.

Excepción: En estructuras asignadas a Categoría de Diseño Sísmico D, se permite usar revestimiento de piedra y mampostería en el primer piso sobre el plano de nivel, siempre que se cumplan los siguientes criterios:

  1. El tipo de refuerzo conforme a la Sección 2308.10.1 será WSP y la capacidad permisible de corte conforme a la Sección 2306.3 será no menor de 350 plf (5108 N/m).

el 18 de julio de 2025 11:14 AM (CDT) SEGÚN LO DISPUESTO.

MADERA

  1. Los paneles de muro contravente en el primer piso se ubicarán en cada extremo de la línea de muro contravente y no más de 25 pies (7620 mm) en centro, y la longitud total de paneles de muro contravente será no menor del 45 por ciento de la longitud de la línea de muro contravente.
  2. Se proporcionarán conectores de sujeción en los extremos de los muros contravente para la conexión del primer piso a la cimentación con una capacidad permisible de 2,100 libras (9341 N).
  3. No se permitirán muros cortos.

3. 2308.11 Estructura de techos y cielos rasos. Los detalles estructurales requeridos…

2308.11 Estructura de techos y cielos rasos. Los detalles estructurales requeridos en esta sección aplican a techos con una pendiente no menor de tres unidades verticales en 12 unidades horizontales (pendiente del 25 por ciento). Cuando la pendiente del techo sea menor de tres unidades verticales en 12 unidades horizontales (pendiente del 25 por ciento), los elementos que soportan las vigas de techo y las vigas de cielo raso, tales como la tabla cumbrera, las caballetes y las valles, deberán diseñarse como vigas.

2308.11.1 Luz de las vigas de cielo raso. Las luces para las vigas de cielo raso deberán estar de acuerdo con la Tabla 2308.11.1(1) o 2308.11.1(2). Para otras calidades y especies, y otras condiciones de carga, consulte el AWC STJR.

TABLE 2308.11.1(1)—CEILING JOIST SPANS FOR COMMON LUMBER SPECIES
(Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)
Col2 Col3 Col4 Col5 Col6 Col7
CEILING JOIST SPACING
(inches)
SPECIES AND GRADE SPECIES AND GRADE DEAD LOAD = 5 psf DEAD LOAD = 5 psf DEAD LOAD = 5 psf DEAD LOAD = 5 psf
CEILING JOIST SPACING
(inches)
SPECIES AND GRADE SPECIES AND GRADE 2 × 4 2 × 6 2 × 8 2 × 10
CEILING JOIST SPACING
(inches)
SPECIES AND GRADE SPECIES AND GRADE Maximum ceiling joist spans Maximum ceiling joist spans Maximum ceiling joist spans Maximum ceiling joist spans
CEILING JOIST SPACING
(inches)
SPECIES AND GRADE SPECIES AND GRADE (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.)
12 Douglas Fir-Larch SS 13-2 20-8 Note a Note a
12 Douglas Fir-Larch #1 12-8 19-11 Note a Note a
12 Douglas Fir-Larch #2 12-5 19-6 25-8 Note a
12 Douglas Fir-Larch #3 10-10 15-10 20-1 24-6
12 Hem-Fir SS 12-5 19-6 25-8 Note a
12 Hem-Fir #1 12-2 19-1 25-2 Note a
12 Hem-Fir #2 11-7 18-2 24-0 Note a
12 Hem-Fir #3 10-10 15-10 20-1 24-6
12 Southern Pine SS 12-11 20-3 Note a Note a
12 Southern Pine #1 12-5 19-6 25-8 Note a
12 Southern Pine #2 11-10 18-8 24-7 Note a
12 Southern Pine #3 10-1 14-11 18-9 22-9
12 Spruce-Pine-Fir SS 12-2 19-1 25-2 Note a
12 Spruce-Pine-Fir #1 11-10 18-8 24-7 Note a
12 Spruce-Pine-Fir #2 11-10 18-8 24-7 Note a
12 Spruce-Pine-Fir #3 10-10 15-10 20-1 24-6
16 Douglas Fir-Larch SS 11-11 18-9 24-8 Note a
16 Douglas Fir-Larch #1 11-6 18-1 23-10 Note a
16 Douglas Fir-Larch #2 11-3 17-8 23-0 Note a
16 Douglas Fir-Larch #3 9-5 13-9 17-5 21-3
16 Hem-Fir SS 11-3 17-8 23-4 Note a
16 Hem-Fir #1 11-0 17-4 22-10 Note a
16 Hem-Fir #2 10-6 16-6 21-9 Note a
16 Hem-Fir #3 9-5 13-9 17-5 21-3
16 Southern Pine SS 11-9 18-5 24-3 Note a
16 Southern Pine #1 11-3 17-8 23-4 Note a
16 Southern Pine #2 10-9 16-11 21-7 25-7
16 Southern Pine #3 8-9 12-11 16-3 19-9
16 Spruce-Pine-Fir SS 11-0 17-4 22-10 Note a
16 Spruce-Pine-Fir #1 10-9 16-11 22-4 Note a
16 Spruce-Pine-Fir #2 10-9 16-11 22-4 Note a
16 Spruce-Pine-Fir #3 9-5 13-9 17-5 21-3

23-56 CÓDIGO DE CONSTRUCCIÓN DE CALIFORNIA 2025

el 18 de julio de 2025 11:14 AM (CDT) BAJO EL MISMO.

MADERA

TABLE 2308.11.1(1)—CEILING JOIST SPANS FOR COMMON LUMBER SPECIES
(Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)—continued
Col2 Col3 Col4 Col5 Col6 Col7
CEILING JOIST SPACING
(inches)
SPECIES AND GRADE SPECIES AND GRADE DEAD LOAD = 5 psf DEAD LOAD = 5 psf DEAD LOAD = 5 psf DEAD LOAD = 5 psf
CEILING JOIST SPACING
(inches)
SPECIES AND GRADE SPECIES AND GRADE 2 × 4 2 × 6 2 × 8 2 × 10
CEILING JOIST SPACING
(inches)
SPECIES AND GRADE SPECIES AND GRADE Maximum ceiling joist spans Maximum ceiling joist spans Maximum ceiling joist spans Maximum ceiling joist spans
CEILING JOIST SPACING
(inches)
SPECIES AND GRADE SPECIES AND GRADE (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.)
19.2 Douglas Fir-Larch SS 11-3 17-8 23-3 Note a
19.2 Douglas Fir-Larch #1 10-10 17-0 22-5 Note a
19.2 Douglas Fir-Larch #2 10-7 16-7 21-0 25-8
19.2 Douglas Fir-Larch #3 8-7 12-6 15-10 19-5
19.2 Hem-Fir SS 10-7 16-8 21-11 Note a
19.2 Hem-Fir #1 10-4 16-4 21-6 Note a
19.2 Hem-Fir #2 9-11 15-7 20-6 25-3
19.2 Hem-Fir #3 8-7 12-6 15-10 19-5
19.2 Southern Pine SS 11-0 17-4 22-10 Note a
19.2 Southern Pine #1 10-7 16-8 22-0 Note a
19.2 Southern Pine #2 10-2 15-7 19-8 23-5
19.2 Southern Pine #3 8-0 11-9 14-10 18-0
19.2 Spruce-Pine-Fir SS 10-4 16-4 21-6 Note a
19.2 Spruce-Pine-Fir #1 10-2 15-11 21-0 25-8
19.2 Spruce-Pine-Fir #2 10-2 15-11 21-0 25-8
19.2 Spruce-Pine-Fir #3 8-7 12-6 15-10 19-5
24 Douglas Fir-Larch SS 10-5 16-4 21-7 Note a
24 Douglas Fir-Larch #1 10-0 15-9 20-1 24-6
24 Douglas Fir-Larch #2 9-10 14-10 18-9 22-11
24 Douglas Fir-Larch #3 7-8 11-2 14-2 17-4
24 Hem-Fir SS 9-10 15-6 20-5 Note a
24 Hem-Fir #1 9-8 15-2 19-7 23-11
24 Hem-Fir #2 9-2 14-5 18-6 22-7
24 Hem-Fir #3 7-8 11-2 14-2 17-4
24 Southern Pine SS 10-3 16-1 21-2 Note a
24 Southern Pine #1 9-10 15-6 20-5 24-0
24 Southern Pine #2 9-3 13-11 17-7 20-11
24 Southern Pine #3 7-2 10-6 13-3 16-1
24 Spruce-Pine-Fir SS 9-8 15-2 19-11 25-5
24 Spruce-Pine-Fir #1 9-5 14-9 18-9 22-11
24 Spruce-Pine-Fir #2 9-5 14-9 18-9 22-11
24 Spruce-Pine-Fir #3 7-8 11-2 14-2 17-4
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. Span exceeds 26 feet in length.

el 18 de julio de 2025 a las 11:14 AM (CDT) BAJO EL MISMO.

MADERA

TABLE 2308.11.1(2)—CEILING JOIST SPANS FOR COMMON LUMBER SPECIES
(Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240)
Col2 Col3 Col4 Col5 Col6 Col7
CEILING JOIST SPACING
(inches)
SPECIES AND GRADE SPECIES AND GRADE DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf
CEILING JOIST SPACING
(inches)
SPECIES AND GRADE SPECIES AND GRADE 2 × 4 2 × 6 2 × 8 2 × 10
CEILING JOIST SPACING
(inches)
SPECIES AND GRADE SPECIES AND GRADE Maximum ceiling joist spans Maximum ceiling joist spans Maximum ceiling joist spans Maximum ceiling joist spans
CEILING JOIST SPACING
(inches)
SPECIES AND GRADE SPECIES AND GRADE (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.)
12 Douglas Fir-Larch SS 10-5 16-4 21-7 Note a
12 Douglas Fir-Larch #1 10-0 15-9 20-1 24-6
12 Douglas Fir-Larch #2 9-10 14-10 18-9 22-11
12 Douglas Fir-Larch #3 7-8 11-2 14-2 17-4
12 Hem-Fir SS 9-10 15-6 20-5 Note a
12 Hem-Fir #1 9-8 15-2 19-7 23-11
12 Hem-Fir #2 9-2 14-5 18-6 22-7
12 Hem-Fir #3 7-8 11-2 14-2 17-4
12 Southern Pine SS 10-3 16-1 21-2 Note a
12 Southern Pine #1 9-10 15-6 20-5 24-0
12 Southern Pine #2 9-3 13-11 17-7 20-11
12 Southern Pine #3 7-2 10-6 13-3 16-1
12 Spruce-Pine-Fir SS 9-8 15-2 19-11 25-5
12 Spruce-Pine-Fir #1 9-5 14-9 18-9 22-11
12 Spruce-Pine-Fir #2 9-5 14-9 18-9 22-11
12 Spruce-Pine-Fir #3 7-8 11-2 14-2 17-4
16 Douglas Fir-Larch SS 9-6 14-11 19-7 25-0
16 Douglas Fir-Larch #1 9-1 13-9 17-5 21-3
16 Douglas Fir-Larch #2 8-9 12-10 16-3 19-10
16 Douglas Fir-Larch #3 6-8 9-8 12-4 15-0
16 Hem-Fir SS 8-11 14-1 18-6 23-8
16 Hem-Fir #1 8-9 13-5 16-10 20-8
16 Hem-Fir #2 8-4 12-8 16-0 19-7
16 Hem-Fir #3 6-8 9-8 12-4 15-0
16 Southern Pine SS 9-4 14-7 19-3 24-7
16 Southern Pine #1 8-11 14-0 17-9 20-9
16 Southern Pine #2 8-0 12-0 15-3 18-1
16 Southern Pine #3 6-2 9-2 11-6 14-0
16 Spruce-Pine-Fir SS 8-9 13-9 18-1 23-1
16 Spruce-Pine-Fir #1 8-7 12-10 16-3 19-10
16 Spruce-Pine-Fir #2 8-7 12-10 16-3 19-10
16 Spruce-Pine-Fir #3 6-8 9-8 12-4 15-0

23-58 CÓDIGO DE CONSTRUCCIÓN DE CALIFORNIA 2025

el 18 de julio de 2025 11:14 AM (CDT) BAJO EL MISMO.

MADERA

TABLE 2308.11.1(2)—CEILING JOIST SPANS FOR COMMON LUMBER SPECIES
(Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240)—continued
Col2 Col3 Col4 Col5 Col6 Col7
CEILING JOIST SPACING
(inches)
SPECIES AND GRADE SPECIES AND GRADE DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf
CEILING JOIST SPACING
(inches)
SPECIES AND GRADE SPECIES AND GRADE 2 × 4 2 × 6 2 × 8 2 × 10
CEILING JOIST SPACING
(inches)
SPECIES AND GRADE SPECIES AND GRADE Maximum ceiling joist spans Maximum ceiling joist spans Maximum ceiling joist spans Maximum ceiling joist spans
CEILING JOIST SPACING
(inches)
SPECIES AND GRADE SPECIES AND GRADE (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.)
19.2 Douglas Fir-Larch SS 8-11 14-0 18-5 23-4
19.2 Douglas Fir-Larch #1 8-7 12-6 15-10 19-5
19.2 Douglas Fir-Larch #2 8-0 11-9 14-10 18-2
19.2 Douglas Fir-Larch #3 6-1 8-10 11-3 13-8
19.2 Hem-Fir SS 8-5 13-3 17-5 22-3
19.2 Hem-Fir #1 8-3 12-3 15-6 18-11
19.2 Hem-Fir #2 7-10 11-7 14-8 17-10
19.2 Hem-Fir #3 6-1 8-10 11-3 13-8
19.2 Southern Pine SS 8-9 13-9 18-2 23-1
19.2 Southern Pine #1 8-5 12-9 16-2 18-11
19.2 Southern Pine #2 7-4 11-0 13-11 16-6
19.2 Southern Pine #3 5-8 8-4 10-6 12-9
19.2 Spruce-Pine-Fir SS 8-3 12-11 17-1 21-8
19.2 Spruce-Pine-Fir #1 8-0 11-9 14-10 18-2
19.2 Spruce-Pine-Fir #2 8-0 11-9 14-10 18-2
19.2 Spruce-Pine-Fir #3 6-1 8-10 11-3 13-8
24 Douglas Fir-Larch SS 8-3 13-0 17-1 20-11
24 Douglas Fir-Larch #1 7-8 11-2 14-2 17-4
24 Douglas Fir-Larch #2 7-2 10-6 13-3 16-3
24 Douglas Fir-Larch #3 5-5 7-11 10-0 12-3
24 Hem-Fir SS 7-10 12-3 16-2 20-6
24 Hem-Fir #1 7-6 10-11 13-10 16-11
24 Hem-Fir #2 7-1 10-4 13-1 16-0
24 Hem-Fir #3 5-5 7-11 10-0 12-3
24 Southern Pine SS 8-1 12-9 16-10 21-6
24 Southern Pine #1 7-8 11-5 14-6 16-11
24 Southern Pine #2 6-7 9-10 12-6 14-9
24 Southern Pine #3 5-1 7-5 9-5 11-5
24 Spruce-Pine-Fir SS 7-8 12-0 15-10 19-5
24 Spruce-Pine-Fir #1 7-2 10-6 13-3 16-3
24 Spruce-Pine-Fir #2 7-2 10-6 13-3 16-3
24 Spruce-Pine-Fir #3 5-5 7-11 10-0 12-3
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. Span exceeds 26 feet in length.

el 18 de julio de 2025 11:14 AM (CDT) BAJO ESTO.

MADERA

2308.11.2 Luz de las vigas de techo. Las luces para las vigas de techo deberán estar de acuerdo con la Tabla 2308.11.2(1), 2308.11.2(2), 2308.11.2(3), 2308.11.2(4), 2308.11.2(5) o 2308.11.2(6). Para otras calidades y especies y otras condiciones de carga, consulte el AWC STJR. La luz de cada viga de techo se medirá a lo largo de la proyección horizontal de la viga.

TABLE 2308.11.2(1)—RAFTER SPANS FOR COMMON LUMBER SPECIES
(Roof live load = 20 psf, ceiling not attached to rafters, L/Δ = 180)
Col2 Col3 Col4 Col5 Col6 Col7 Col8 Col9 Col10 Col11 Col12 Col13
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
(ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.)
12 Douglas
Fir-Larch
SS 11-6 18-0 23-9 Note b Note b 11-6 18-0 23-5 Note b Note b
12 Douglas
Fir-Larch
#1 11-1 17-4 22-5 Note b Note b 10-6 15-4 19-5 23-9 Note b
12 Douglas
Fir-Larch
#2 10-10 16-7 21-0 25-8 Note b 9-10 14-4 18-2 22-3 25-9
12 Douglas
Fir-Larch
#3 8-7 12-6 15-10 19-5 22-6 7-5 10-10 13-9 16-9 19-6
12 Hem-Fir SS 10-10 17-0 22-5 Note b Note b 10-10 17-0 22-5 Note b Note b
12 Hem-Fir #1 10 -7 16-8 21-10 Note b Note b 10-3 14-11 18-11 23-2 Note b
12 Hem-Fir #2 10-1 15-11 20-8 25-3 Note b 9-8 14-2 17-11 21-11 25-5
12 Hem-Fir #3 8-7 12-6 15-10 19-5 22-6 7-5 10-10 13-9 16-9 19-6
12 Southern
Pine
SS 11-3 17-8 23-4 Note b Note b 11-3 17-8 23-4 Note b Note b
12—
continued
Southern
Pine
#1 10-10 17-0 22-5 26-0 26-0 10-6 15-8 19-10 23-2 Note b
12—
continued
Southern
Pine
#2 10-4 15-7 19-8 23-5 26-0 9-0 13-6 17-1 20-3 23-10
12—
continued
Southern
Pine
#3 8-0 11-9 14-10 18-0 21-4 6-11 10-2 12-10 15-7 18-6
12—
continued
Spruce-
Pine-Fir
SS 10-7 16-8 21-11 Note b Note b 10-7 16-8 21-9 Note b Note b
12—
continued
Spruce-
Pine-Fir
#1 10-4 16-3 21-0 25-8 Note b 9-10 14-4 18-2 22-3 25-9
12—
continued
Spruce-
Pine-Fir
#2 10-4 16-3 21-0 25-8 Note b 9-10 14-4 18-2 22-3 25-9
12—
continued
Spruce-
Pine-Fir
#3 8-7 12-6 15-10 19-5 22-6 7-5 10-10 13-9 16-9 19-6

23-60 CÓDIGO DE CONSTRUCCIÓN DE CALIFORNIA 2025

el 18 de julio de 2025 11:14 AM (CDT) BAJO EL MISMO.

MADERA

TABLE 2308.11.2(1)—RAFTER SPANS FOR COMMON LUMBER SPECIES
(Roof live load = 20 psf, ceiling not attached to rafters, L/Δ = 180)—continued
Col2 Col3 Col4 Col5 Col6 Col7 Col8 Col9 Col10 Col11 Col12 Col13
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
(ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.)
16 Douglas
Fir-Larch
SS 10-5 16-4 21-7 Note b Note b 10-5 16-0 20-3 24-9 Note b
16 Douglas
Fir-Larch
#1 10-0 15-4 19-5 23-9 Note b 9-1 13-3 16-10 20-7 23-10
16 Douglas
Fir-Larch
#2 9-10 14-4 18-2 22-3 25-9 8-6 12-5 15-9 19-3 22-4
16 Douglas
Fir-Larch
#3 7-5 10-10 13-9 16-9 19-6 6-5 9-5 11-11 14-6 16-10
16 Hem-Fir SS 9-10 15-6 20-5 Note b Note b 9-10 15-6 19-11 24-4 Note b
16 Hem-Fir #1 9-8 14-11 18-11 23-2 Note b 8-10 12-11 16-5 20-0 23-3
16 Hem-Fir #2 9-2 14-2 17-11 21-11 25-5 8-5 12-3 15-6 18-11 22-0
16 Hem-Fir #3 7-5 10-10 13-9 16-9 19-6 6-5 9-5 11-11 14-6 16-10
16 Southern
Pine
SS 10-3 16-1 21-2 Note b Note b 10-3 16-1 21-2 25-7 Note b
16 Southern
Pine
#1 9-10 15-6 19-10 23-2 26-0 9-1 13-7 17-2 20-1 23-10
16 Southern
Pine
#2 9-0 13-6 17-1 20-3 23-10 7-9 11-8 14-9 17-6 20-8
16 Southern
Pine
#3 6-11 10-2 12-10 15-7 18-6 6-0 8-10 11-2 13-6 16-0
16 Spruce-
Pine-Fir
SS 9-8 15-2 19-11 25-5 Note b 9-8 14-10 18-10 23-0 Note b
16 Spruce-
Pine-Fir
#1 9-5 14-4 18-2 22-3 25-9 8-6 12-5 15-9 19-3 22-4
16 Spruce-
Pine-Fir
#2 9-5 14-4 18-2 22-3 25-9 8-6 12-5 15-9 19-3 22-4
16 Spruce-
Pine-Fir
#3 7-5 10-10 13-9 16-9 19-6 6-5 9-5 11-11 14-6 16-10

el 18 de julio de 2025 11:14 AM (CDT) BAJO EL MISMO.

MADERA

TABLE 2308.11.2(1)—RAFTER SPANS FOR COMMON LUMBER SPECIES
(Roof live load = 20 psf, ceiling not attached to rafters, L/Δ = 180)—continued
Col2 Col3 Col4 Col5 Col6 Col7 Col8 Col9 Col10 Col11 Col12 Col13
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
(ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.)
19.2 Douglas
Fir-Larch
SS 9-10 15-5 20-4 25-11 Note b 9-10 14-7 18-6 22-7 Note b
19.2 Douglas
Fir-Larch
#1 9-5 14-0 17-9 21-8 25-2 8-4 12-2 15-4 18-9 21-9
19.2 Douglas
Fir-Larch
#2 8-11 13-1 16-7 20-3 23-6 7-9 11-4 14-4 17-7 20-4
19.2 Douglas
Fir-Larch
#3 6-9 9-11 12-7 15-4 17-9 5-10 8-7 10-10 13-3 15-5
19.2 Hem-Fir SS 9-3 14-7 19-2 24-6 Note b 9-3 14-4 18-2 22-3 25-9
19.2 Hem-Fir #1 9-1 13-8 17-4 21-1 24-6 8-1 11-10 15-0 18-4 21-3
19.2 Hem-Fir #2 8-8 12-11 16-4 20-0 23-2 7-8 11-2 14-2 17-4 20-1
19.2 Hem-Fir #3 6-9 9-11 12-7 15-4 17-9 5-10 8-7 10-10 13-3 15-5
19.2 Southern
Pine
SS 9-8 15-2 19-11 25-5 Note b 9-8 15-2 19-7 23-4 Note b
19.2 Southern
Pine
#1 9-3 14-3 18-1 21-2 25-2 8-4 12-4 15-8 18-4 21-9
19.2 Southern
Pine
#2 8-2 12-3 15-7 18-6 21-9 7-1 10-8 13-6 16-0 18-10
19.2 Southern
Pine
#3 6-4 9-4 11-9 14-3 16-10 5-6 8-1 10-2 12-4 14-7
19.2 Spruce-
Pine-Fir
SS 9-1 14-3 18-9 23-11 Note b 9-1 13-7 17-2 21-0 24-4
19.2 Spruce-
Pine-Fir
#1 8-10 13-1 16-7 20-3 23-6 7-9 11-4 14-4 17-7 20-4
19.2 Spruce-
Pine-Fir
#2 8-10 13-1 16-7 20-3 23-6 7-9 11-4 14-4 17-7 20-4
19.2 Spruce-
Pine-Fir
#3 6-9 9-11 12-7 15-4 17-9 5-10 8-7 10-10 13-3 15-5
24 Douglas
Fir-Larch
SS 9-1 14-4 18-10 23-4 Note b 8-11 13-1 16-7 20-3 23-5
24 Douglas
Fir-Larch
#1 8-7 12-6 15-10 19-5 22-6 7-5 10-10 13-9 16-9 19-6
24 Douglas
Fir-Larch
#2 8-0 11-9 14-10 18-2 21-0 6-11 10-2 12-10 15-8 18-3
24 Douglas
Fir-Larch
#3 6-1 8-10 11-3 13-8 15-11 5-3 7-8 9-9 11-10 13-9
24 Hem-Fir SS 8-7 13-6 17-10 22-9 Note b 8-7 12-10 16-3 19-10 23-0
24 Hem-Fir #1 8-4 12-3 15-6 18-11 21-11 7-3 10-7 13-5 16-4 19-0
24 Hem-Fir #2 7-11 11-7 14-8 17-10 20-9 6-10 10-0 12-8 15-6 17-11
24 Hem-Fir #3 6-1 8-10 11-3 13-8 15-11 5-3 7-8 9-9 11-10 13-9
24 Southern
Pine
SS 8-11 14-1 18-6 23-8 Note b 8-11 13-10 17-6 20-10 24-8
24 Southern
Pine
#1 8-7 12-9 16-2 18-11 22-6 7-5 11-1 14-0 16-5 19-6
24 Southern
Pine
#2 7-4 11-0 13-11 16-6 19-6 6-4 9-6 12-1 14-4 16-10
24 Southern
Pine
#3 5-8 8-4 10-6 12-9 15-1 4-11 7-3 9-1 11-0 13-1

23-62 CÓDIGO DE CONSTRUCCIÓN DE CALIFORNIA 2025

el 18 de julio de 2025 11:14 AM (CDT) BAJO EL MISMO.

MADERA

TABLE 2308.11.2(1)—RAFTER SPANS FOR COMMON LUMBER SPECIES
(Roof live load = 20 psf, ceiling not attached to rafters, L/Δ = 180)—continued
Col2 Col3 Col4 Col5 Col6 Col7 Col8 Col9 Col10 Col11 Col12 Col13
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
(ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.)
24—
continued
Spruce-
Pine-Fir
SS 8-5 13-3 17-5 21-8 25-2 8-4 12-2 15-4 18-9 21-9
24—
continued
Spruce-
Pine-Fir
#1 8-0 11-9 14-10 18-2 21-0 6-11 10-2 12-10 15-8 18-3
24—
continued
Spruce-
Pine-Fir
#2 8-0 11-9 14-10 18-2 21-0 6-11 10-2 12-10 15-8 18-3
24—
continued
Spruce-
Pine-Fir
#3 6-1 8-10 11-3 13-8 15-11 5-3 7-8 9-9 11-10 13-9
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
TABLE 2308.11.2(2)—RAFTER SPANS FOR COMMON LUMBER SPECIES
(Roof live load = 20 psf, ceiling attached to rafters, L/Δ = 240)
Col2 Col3 Col4 Col5 Col6 Col7 Col8 Col9 Col10 Col11 Col12 Col13
--- --- --- --- --- --- --- --- --- --- --- --- ---
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
(ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.)
12 Douglas
Fir-Larch
SS 10-5 16-4 21-7 Note b Note b 10-5 16-4 21-7 Note b Note b
12 Douglas
Fir-Larch
#1 10-0 15-9 20-10 Note b Note b 10-0 15-4 19-5 23-9 Note b
12 Douglas
Fir-Larch
#2 9-10 15-6 20-5 25-8 Note b 9-10 14-4 18-2 22-3 25-9
12 Douglas
Fir-Larch
#3 8-7 12-6 15-10 19-5 22-6 7-5 10-10 13-9 16-9 19-6
12 Hem-Fir SS 9-10 15-6 20-5 Note b Note b 9-10 15-6 20-5 Note b Note b
12 Hem-Fir #1 9-8 15-2 19-11 25-5 Note b 9-8 14-11 18-11 23-2 Note b
12 Hem-Fir #2 9-2 14-5 19-0 24-3 Note b 9-2 14-2 17-11 21-11 25-5
12 Hem-Fir #3 8-7 12-6 15-10 19-5 22-6 7-5 10-10 13-9 16-9 19-6
12 Southern
Pine
SS 10-3 16-1 21-2 Note b Note b 10-3 16-1 21-2 Note b Note b
12 Southern
Pine
#1 9-10 15-6 20-5 26-0 26-0 9-10 15-6 19-10 23-2 26-0
12 Southern
Pine
#2 9-5 14-9 19-6 23-5 26-0 9-0 13-6 17-1 20-3 23-10
12 Southern
Pine
#3 8-0 11-9 14-10 18-0 21-4 6-11 10-2 12-10 15-7 18-6
12 Spruce-
Pine-Fir
SS 9-8 15-2 19-11 25-5 Note b 9-8 15-2 19-11 25-5 Note b
12 Spruce-
Pine-Fir
#1 9-5 14-9 19-6 24-10 Note b 9-5 14-4 18-2 22-3 25-9
12 Spruce-
Pine-Fir
#2 9-5 14-9 19-6 24-10 Note b 9-5 14-4 18-2 22-3 25-9
12 Spruce-
Pine-Fir
#3 8-7 12-6 15-10 19-5 22-6 7-5 10-10 13-9 16-9 19-6

el 18 de julio de 2025 11:14 AM (CDT) BAJO EL MISMO.

MADERA

TABLE 2308.11.2(2)—RAFTER SPANS FOR COMMON LUMBER SPECIES
(Roof live load = 20 psf, ceiling attached to rafters, L/Δ = 240)—continued
Col2 Col3 Col4 Col5 Col6 Col7 Col8 Col9 Col10 Col11 Col12 Col13
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
(ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.)
16 Douglas
Fir-Larch
SS 9-6 14-11 19-7 25-0 Note b 9-6 14-11 19-7 24-9 Note b
16 Douglas
Fir-Larch
#1 9-1 14-4 18-11 23-9 Note b 9-1 13-3 16-10 20-7 23-10
16 Douglas
Fir-Larch
#2 8-11 14-1 18-2 22-3 25-9 8-6 12-5 15-9 19-3 22-4
16 Douglas
Fir-Larch
#3 7-5 10-10 13-9 16-9 19-6 6-5 9-5 11-11 14-6 16-10
16 Hem-Fir SS 8-11 14-1 18-6 23-8 Note b 8-11 14-1 18-6 23-8 Note b
16 Hem-Fir #1 8-9 13-9 18-1 23-1 Note b 8-9 12-11 16-5 20-0 23-3
16 Hem-Fir #2 8-4 13-1 17-3 21-11 25-5 8-4 12-3 15-6 18-11 22-0
16 Hem-Fir #3 7-5 10-10 13-9 16-9 19-6 6-5 9-5 11-11 14-6 16-10
16 Southern
Pine
SS 9-4 14-7 19-3 24-7 Note b 9-4 14-7 19-3 24-7 Note b
16 Southern
Pine
#1 8-11 14-1 18-6 23-2 26-0 8-11 13-7 17-2 20-1 23-10
16 Southern
Pine
#2 8-7 13-5 17-1 20-3 23-10 7-9 11-8 14-9 17-6 20-8
16 Southern
Pine
#3 6-11 10-2 12-10 15-7 18-6 6-0 8-10 11-2 13-6 16-0
16 Spruce-
Pine-Fir
SS 8-9 13-9 18-1 23-1 Note b 8-9 13-9 18-1 23-0 Note b
16 Spruce-
Pine-Fir
#1 8-7 13-5 17-9 22-3 25-9 8-6 12-5 15-9 19-3 22-4
16 Spruce-
Pine-Fir
#2 8-7 13-5 17-9 22-3 25-9 8-6 12-5 15-9 19-3 22-4
16 Spruce-
Pine-Fir
#3 7-5 10-10 13-9 16-9 19-6 6-5 9-5 11-11 14-6 16-10
19.2 Douglas
Fir-Larch
SS 8-11 14-0 18-5 23-7 Note b 8-11 14-0 18-5 22-7 Note b
19.2 Douglas
Fir-Larch
#1 8-7 13-6 17-9 21-8 25-2 8-4 12-2 15-4 18-9 21-9
19.2 Douglas
Fir-Larch
#2 8-5 13-1 16-7 20-3 23-6 7-9 11-4 14-4 17-7 20-4
19.2 Douglas
Fir-Larch
#3 6-9 9-11 12-7 15-4 17-9 5-10 8-7 10-10 13-3 15-5
19.2 Hem-Fir SS 8-5 13-3 17-5 22-3 Note b 8-5 13-3 17-5 22-3 25-9
19.2 Hem-Fir #1 8-3 12-11 17-1 21-1 24-6 8-1 11-10 15-0 18-4 21-3
19.2 Hem-Fir #2 7-10 12-4 16-3 20-0 23-2 7-8 11-2 14-2 17-4 20-1
19.2 Hem-Fir #3 6-9 9-11 12-7 15-4 17-9 5-10 8-7 10-10 13-3 15-5
19.2 Southern
Pine
SS 8-9 13-9 18-2 23-1 Note b 8-9 13-9 18-2 23-1 Note b
19.2 Southern
Pine
#1 8-5 13-3 17-5 21-2 25-2 8-4 12-4 15-8 18-4 21-9
19.2 Southern
Pine
#2 8-1 12-3 15-7 18-6 21-9 7-1 10-8 13-6 16-0 18-10
19.2 Southern
Pine
#3 6-4 9-4 11-9 14-3 16-10 5-6 8-1 10-2 12-4 14-7

23-64 CÓDIGO DE CONSTRUCCIÓN DE CALIFORNIA 2025

el 18 de julio de 2025 11:14 AM (CDT) BAJO EL MISMO.

MADERA

TABLE 2308.11.2(2)—RAFTER SPANS FOR COMMON LUMBER SPECIES
(Roof live load = 20 psf, ceiling attached to rafters, L/Δ = 240)—continued
Col2 Col3 Col4 Col5 Col6 Col7 Col8 Col9 Col10 Col11 Col12 Col13
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
(ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.)
19.2—
continued
Spruce-
Pine-Fir
SS 8-3 12-11 17-1 21-9 Note b 8-3 12-11 17-1 21-0 24-4
19.2—
continued
Spruce-
Pine-Fir
#1 8-1 12-8 16-7 20-3 23-6 7-9 11-4 14-4 17-7 20-4
19.2—
continued
Spruce-
Pine-Fir
#2 8-1 12-8 16-7 20-3 23-6 7-9 11-4 14-4 17-7 20-4
19.2—
continued
Spruce-
Pine-Fir
#3 6-9 9-11 12-7 15-4 17-9 5-10 8-7 10-10 13-3 15-5
24 Douglas
Fir-Larch
SS 8-3 13-0 17-2 21-10 Note b 8-3 13-0 16-7 20-3 23-5
24 Douglas
Fir-Larch
#1 8-0 12-6 15-10 19-5 22-6 7-5 10-10 13-9 16-9 19-6
24 Douglas
Fir-Larch
#2 7-10 11-9 14-10 18-2 21-0 6-11 10-2 12-10 15-8 18-3
24 Douglas
Fir-Larch
#3 6-1 8-10 11-3 13-8 15-11 5-3 7-8 9-9 11-10 13-9
24 Hem-Fir SS 7-10 12-3 16-2 20-8 25-1 7-10 12-3 16-2 19-10 23-0
24 Hem-Fir #1 7-8 12-0 15-6 18-11 21-11 7-3 10-7 13-5 16-4 19-0
24 Hem-Fir #2 7-3 11-5 14-8 17-10 20-9 6-10 10-0 12-8 15-6 17-11
24 Hem-Fir #3 6-1 8-10 11-3 13-8 15-11 5-3 7-8 9-9 11-10 13-9
24 Southern
Pine
SS 8-1 12-9 16-10 21-6 Note b 8-1 12-9 16-10 20-10 24-8
24 Southern
Pine
#1 7-10 12-3 16-2 18-11 22-6 7-5 11-1 14-0 16-5 19-6
24 Southern
Pine
#2 7-4 11-0 13-11 16-6 19-6 6-4 9-6 12-1 14-4 16-10
24 Southern
Pine
#3 5-8 8-4 10-6 12-9 15-1 4-11 7-3 9-1 11-0 13-1
24 Spruce-
Pine-Fir
SS 7-8 12-0 15-10 20-2 24-7 7-8 12-0 15-4 18-9 21-9
24 Spruce-
Pine-Fir
#1 7-6 11-9 14-10 18-2 21-0 6-11 10-2 12-10 15-8 18-3
24 Spruce-
Pine-Fir
#2 7-6 11-9 14-10 18-2 21-0 6-11 10-2 12-10 15-8 18-3
24 Spruce-
Pine-Fir
#3 6-1 8-10 11-3 13-8 15-11 5-3 7-8 9-9 11-10 13-9
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.

el 18 de julio de 2025 11:14 AM (CDT) BAJO EL MISMO.

MADERA

TABLE 2308.11.2(3)—RAFTER SPANS FOR COMMON LUMBER SPECIES
(Allowable stress design ground snow load, p = 30 psf, ceiling not attached to rafters, L/Δ = 180)
g(asd)
Col2 Col3 Col4 Col5 Col6 Col7 Col8 Col9 Col10 Col11 Col12 Col13
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
(ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.)
12 Douglas
Fir-Larch
SS 10-0 15-9 20-9 Note b Note b 10-0 15-9 20-1 24-6 Note b
12 Douglas
Fir-Larch
#1 9-8 14-9 18-8 22-9 Note b 9-0 13-2 16-8 20-4 23-7
12 Douglas
Fir-Larch
#2 9-5 13-9 17-5 21-4 24-8 8-5 12-4 15-7 19-1 22-1
12 Douglas
Fir-Larch
#3 7-1 10-5 13-2 16-1 18-8 6-4 9-4 11-9 14-5 16-8
12 Hem-Fir SS 9-6 14-10 19-7 25-0 Note b 9-6 14-10 19-7 24-1 Note b
12 Hem-Fir #1 9-3 14-4 18-2 22-2 25-9 8-9 12-10 16-3 19-10 23-0
12 Hem-Fir #2 8-10 13-7 17-2 21-0 24-4 8-4 12-2 15-4 18-9 21-9
12 Hem-Fir #3 7-1 10-5 13-2 16-1 18-8 6-4 9-4 11-9 14-5 16-8
12 Southern
Pine
SS 9-10 15-6 20-5 Note b Note b 9-10 15-6 20-5 25-4 Note b
12 Southern
Pine
#1 9-6 14-10 19-0 22-3 26-0 9-0 13-5 17-0 19-11 23-7
12 Southern
Pine
#2 8-7 12-11 16-4 19-5 22-10 7-8 11-7 14-8 17-4 20-5
12 Southern
Pine
#3 6-7 9-9 12-4 15-0 17-9 5-11 8-9 11-0 13-5 15-10
12 Spruce-
Pine-Fir
SS 9-3 14-7 19-2 24-6 Note b 9-3 14-7 18-8 22-9 Note b
12 Spruce-
Pine-Fir
#1 9-1 13-9 17-5 21-4 24-8 8-5 12-4 15-7 19-1 22-1
12 Spruce-
Pine-Fir
#2 9-1 13-9 17-5 21-4 24-8 8-5 12-4 15-7 19-1 22-1
12 Spruce-
Pine-Fir
#3 7-1 10-5 13-2 16-1 18-8 6-4 9-4 11-9 14-5 16-8
16 Douglas
Fir-Larch
SS 9-1 14-4 18-10 23-9 Note b 9-1 13-9 17-5 21-3 24-8
16 Douglas
Fir-Larch
#1 8-9 12-9 16-2 19-9 22-10 7-10 11-5 14-5 17-8 20-5
16 Douglas
Fir-Larch
#2 8-2 11-11 15-1 18-5 21-5 7-3 10-8 13-6 16-6 19-2
16 Douglas
Fir-Larch
#3 6-2 9-0 11-5 13-11 16-2 5-6 8-1 10-3 12-6 14-6
16 Hem-Fir SS 8-7 13-6 17-10 22-9 Note b 8-7 13-6 17-1 20-10 24-2
16 Hem-Fir #1 8-5 12-5 15-9 19-3 22-3 7-7 11-1 14-1 17-2 19-11
16 Hem-Fir #2 8-0 11-9 14-11 18-2 21-1 7-2 10-6 13-4 16-3 18-10
16 Hem-Fir #3 6-2 9-0 11-5 13-11 16-2 5-6 8-1 10-3 12-6 14-6
16 Southern
Pine
SS 8-11 14-1 18-6 23-8 Note b 8-11 14-1 18-5 21-11 25-11
16 Southern
Pine
#1 8-7 13-0 16-6 19-3 22-10 7-10 11-7 14-9 17-3 20-5
16 Southern
Pine
#2 7-6 11-2 14-2 16-10 19-10 6-8 10-0 12-8 15-1 17-9
16 Southern
Pine
#3 5-9 8-6 10-8 13-0 15-4 5-2 7-7 9-7 11-7 13-9

23-66 CÓDIGO DE CONSTRUCCIÓN DE CALIFORNIA 2025

el 18 de julio de 2025 11:14 AM (CDT) BAJO EL MISMO.

MADERA

TABLE 2308.11.2(3)—RAFTER SPANS FOR COMMON LUMBER SPECIES
(Allowable stress design ground snow load, p = 30 psf, ceiling not attached to rafters, L/Δ = 180)—continued
g(asd)
Col2 Col3 Col4 Col5 Col6 Col7 Col8 Col9 Col10 Col11 Col12 Col13
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
(ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.)
16—
continued
Spruce-
Pine-Fir
SS 8-5 13-3 17-5 22-1 25-7 8-5 12-9 16-2 19-9 22-10
16—
continued
Spruce-
Pine-Fir
#1 8-2 11-11 15-1 18-5 21-5 7-3 10-8 13-6 16-6 19-2
16—
continued
Spruce-
Pine-Fir
#2 8-2 11-11 15-1 18-5 21-5 7-3 10-8 13-6 16-6 19-2
16—
continued
Spruce-
Pine-Fir
#3 6-2 9-0 11-5 13-11 16-2 5-6 8-1 10-3 12-6 14-6
19.2 Douglas
Fir-Larch
SS 8-7 13-6 17-9 21-8 25-2 8-7 12-6 15-10 19-5 22-6
19.2 Douglas
Fir-Larch
#1 7-11 11-8 14-9 18-0 20-11 7-1 10-5 13-2 16-1 18-8
19.2 Douglas
Fir-Larch
#2 7-5 10-11 13-9 16-10 19-6 6-8 9-9 12-4 15-1 17-6
19.2 Douglas
Fir-Larch
#3 5-7 8-3 10-5 12-9 14-9 5-0 7-4 9-4 11-5 13-2
19.2 Hem-Fir SS 8-1 12-9 16-9 21-4 24-8 8-1 12-4 15-7 19-1 22-1
19.2 Hem-Fir #1 7-9 11-4 14-4 17-7 20-4 6-11 10-2 12-10 15-8 18-2
19.2 Hem-Fir #2 7-4 10-9 13-7 16-7 19-3 6-7 9-7 12-2 14-10 17-3
19.2 Hem-Fir #3 5-7 8-3 10-5 12-9 14-9 5-0 7-4 9-4 11-5 13-2
19.2 Southern
Pine
SS 8-5 13-3 17-5 22-3 Note b 8-5 13-3 16-10 20-0 23-7
19.2 Southern
Pine
#1 8-0 11-10 15-1 17-7 20-11 7-1 10-7 13-5 15-9 18-8
19.2 Southern
Pine
#2 6-10 10-2 12-11 15-4 18-1 6-1 9-2 11-7 13-9 16-2
19.2 Southern
Pine
#3 5-3 7-9 9-9 11-10 14-0 4-8 6-11 8-9 10-7 12-6
19.2 Spruce-
Pine-Fir
SS 7-11 12-5 16-5 20-2 23-4 7-11 11-8 14-9 18-0 20-11
19.2 Spruce-
Pine-Fir
#1 7-5 10-11 13-9 16-10 19-6 6-8 9-9 12-4 15-1 17-6
19.2 Spruce-
Pine-Fir
#2 7-5 10-11 13-9 16-10 19-6 6-8 9-9 12-4 15-1 17-6
19.2 Spruce-
Pine-Fir
#3 5-7 8-3 10-5 12-9 14-9 5-0 7-4 9-4 11-5 13-2
24 Douglas
Fir-Larch
SS 7-11 12-6 15-10 19-5 22-6 7-8 11-3 14-2 17-4 20-1
24 Douglas
Fir-Larch
#1 7-1 10-5 13-2 16-1 18-8 6-4 9-4 11-9 14-5 16-8
24 Douglas
Fir-Larch
#2 6-8 9-9 12-4 15-1 17-6 5-11 8-8 11-0 13-6 15-7
24 Douglas
Fir-Larch
#3 5-0 7-4 9-4 11-5 13-2 4-6 6-7 8-4 10-2 11-10
24 Hem-Fir SS 7-6 11-10 15-7 19-1 22-1 7-6 11-0 13-11 17-0 19-9
24 Hem-Fir #1 6-11 10-2 12-10 15-8 18-2 6-2 9-1 11-6 14-0 16-3
24 Hem-Fir #2 6-7 9-7 12-2 14-10 17-3 5-10 8-7 10-10 13-3 15-5
24 Hem-Fir #3 5-0 7-4 9-4 11-5 13-2 4-6 6-7 8-4 10-2 11-10

el 18 de julio de 2025 a las 11:14 AM (CDT) BAJO EL MISMO.

MADERA

TABLE 2308.11.2(3)—RAFTER SPANS FOR COMMON LUMBER SPECIES
(Allowable stress design ground snow load, p = 30 psf, ceiling not attached to rafters, L/Δ = 180)—continued
g(asd)
Col2 Col3 Col4 Col5 Col6 Col7 Col8 Col9 Col10 Col11 Col12 Col13
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
(ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.)
24—
continued
Southern
Pine
SS 7-10 12-3 16-2 20-0 23-7 7-10 11-10 15-0 17-11 21-2
24—
continued
Southern
Pine
#1 7-1 10-7 13-5 15-9 18-8 6-4 9-6 12-0 14-1 16-8
24—
continued
Southern
Pine
#2 6-1 9-2 11-7 13-9 16-2 5-5 8-2 10-4 12-3 14-6
24—
continued
Southern
Pine
#3 4-8 6-11 8-9 10-7 12-6 4-2 6-2 7-10 9-6 11-2
24—
continued
Spruce-
Pine-Fir
SS 7-4 11-7 14-9 18-0 20-11 7-1 10-5 13-2 16-1 18-8
24—
continued
Spruce-
Pine-Fir
#1 6-8 9-9 12-4 15-1 17-6 5-11 8-8 11-0 13-6 15-7
24—
continued
Spruce-
Pine-Fir
#2 6-8 9-9 12-4 15-1 17-6 5-11 8-8 11-0 13-6 15-7
24—
continued
Spruce-
Pine-Fir
#3 5-0 7-4 9-4 11-5 13-2 4-6 6-7 8-4 10-2 11-10
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
TABLE 2308.11.2(4)—RAFTER SPANS FOR COMMON LUMBER SPECIES
(Allowable stress design ground snow load, p = 50 psf, ceiling not attached to rafters, L/Δ = 180)
g(asd)
Col2 Col3 Col4 Col5 Col6 Col7 Col8 Col9 Col10 Col11 Col12 Col13
--- --- --- --- --- --- --- --- --- --- --- --- ---
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
(ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.)
12 Douglas
Fir-Larch
SS 8-5 13-3 17-6 22-4 26-0 8-5 13-3 17-0 20-9 24-0
12 Douglas
Fir-larch
#1 8-2 12-0 15-3 18-7 21-7 7-7 11-2 14-1 17-3 20-0
12 Douglas
Fir-larch
#2 7-8 11-3 14-3 17-5 20-2 7-1 10-5 13-2 16-1 18-8
12 Douglas
Fir-larch
#3 5-10 8-6 10-9 13-2 15-3 5-5 7-10 10-0 12-2 14-1
12 Hem-Fir SS 8-0 12-6 16-6 21-1 25-6 8-0 12-6 16-6 20-4 23-7
12 Hem-Fir #1 7-10 11-9 14-10 18-1 21-0 7-5 10-10 13-9 16-9 19-5
12 Hem-Fir #2 7-5 11-1 14-0 17-2 19-11 7-0 10-3 13-0 15-10 18-5
12 Hem-Fir #3 5-10 8-6 10-9 13-2 15-3 5-5 7-10 10-0 12-2 14-1
12 Southern
Pine
SS 8-4 13-1 17-2 21-11 Note b 8-4 13-1 17-2 21-5 25-3
12 Southern
Pine
#1 8-0 12-3 15-6 18-2 21-7 7-7 11-4 14-5 16-10 20-0
12 Southern
Pine
#2 7-0 10-6 13-4 15-10 18-8 6-6 9-9 12-4 14-8 17-3
12 Southern
Pine
#3 5-5 8-0 10-1 12-3 14-6 5-0 7-5 9-4 11-4 13-5

23-68 CÓDIGO DE CONSTRUCCIÓN DE CALIFORNIA 2025

el 18 de julio de 2025 11:14 AM (CDT) BAJO EL MISMO.

MADERA

TABLE 2308.11.2(4)—RAFTER SPANS FOR COMMON LUMBER SPECIES
(Allowable stress design ground snow load, p = 50 psf, ceiling not attached to rafters, L/Δ = 180)—continued
g(asd)
Col2 Col3 Col4 Col5 Col6 Col7 Col8 Col9 Col10 Col11 Col12 Col13
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
(ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.)
12—
continued
Spruce-
Pine-Fir
SS 7-10 12-3 16-2 20-8 24-1 7-10 12-3 15-9 19-3 22-4
12—
continued
Spruce-
Pine-Fir
#1 7-8 11-3 14-3 17-5 20-2 7-1 10-5 13-2 16-1 18-8
12—
continued
Spruce-
Pine-Fir
#2 7-8 11-3 14-3 17-5 20-2 7-1 10-5 13-2 16-1 18-8
12—
continued
Spruce-
Pine-Fir
#3 5-10 8-6 10-9 13-2 15-3 5-5 7-10 10-0 12-2 14-1
16 Douglas
Fir-Larch
SS 7-8 12-1 15-10 19-5 22-6 7-8 11-7 14-8 17-11 20-10
16 Douglas
Fir-Larch
#1 7-1 10-5 13-2 16-1 18-8 6-7 9-8 12-2 14-11 17-3
16 Douglas
Fir-Larch
#2 6-8 9-9 12-4 15-1 17-6 6-2 9-0 11-5 13-11 16-2
16 Douglas
Fir-Larch
#3 5-0 7-4 9-4 11-5 13-2 4-8 6-10 8-8 10-6 12-3
16 Hem-Fir SS 7-3 11-5 15-0 19-1 22-1 7-3 11-5 14-5 17-8 20-5
16 Hem-Fir #1 6-11 10-2 12-10 15-8 18-2 6-5 9-5 11-11 14-6 16-10
16 Hem-Fir #2 6-7 9-7 12-2 14-10 17-3 6-1 8-11 11-3 13-9 15-11
16 Hem-Fir #3 5-0 7-4 9-4 11-5 13-2 4-8 6-10 8-8 10-6 12-3
16 Southern
Pine
SS 7-6 11-10 15-7 19-11 23-7 7-6 11-10 15-7 18-6 21-10
16 Southern
Pine
#1 7-1 10-7 13-5 15-9 18-8 6-7 9-10 12-5 14-7 17-3
16 Southern
Pine
#2 6-1 9-2 11-7 13-9 16-2 5-8 8-5 10-9 12-9 15-0
16 Southern
Pine
#3 4-8 6-11 8-9 10-7 12-6 4-4 6-5 8-1 9-10 11-7
16 Spruce-
Pine-Fir
SS 7-1 11-2 14-8 18-0 20-11 7-1 10-9 13-8 15-11 19-4
16 Spruce-
Pine-Fir
#1 6-8 9-9 12-4 15-1 17-6 6-2 9-0 11-5 13-11 16-2
16 Spruce-
Pine-Fir
#2 6-8 9-9 12-4 15-1 17-6 6-2 9-0 11-5 13-11 16-2
16 Spruce-
Pine-Fir
#3 5-0 7-4 9-4 11-5 13-2 4-8 6-10 8-8 10-6 12-3
19.2 Douglas
Fir-Larch
SS 7-3 11-4 14-6 17-8 20-6 7-3 10-7 13-5 16-5 19-0
19.2 Douglas
Fir-Larch
#1 6-6 9-6 12-0 14-8 17-1 6-0 8-10 11-2 13-7 15-9
19.2 Douglas
Fir-Larch
#2 6-1 8-11 11-3 13-9 15-11 5-7 8-3 10-5 12-9 14-9
19.2 Douglas
Fir-Larch
#3 4-7 6-9 8-6 10-5 12-1 4-3 6-3 7-11 9-7 11-2
19.2 Hem-Fir SS 6-10 10-9 14-2 17-5 20-2 6-10 10-5 13-2 16-1 18-8
19.2 Hem-Fir #1 6-4 9-3 11-9 14-4 16-7 5-10 8-7 10-10 13-3 15-5
19.2 Hem-Fir #2 6-0 8-9 11-1 13-7 15-9 5-7 8-1 10-3 12-7 14-7
19.2 Hem-Fir #3 4-7 6-9 8-6 10-5 12-1 4-3 6-3 7-11 9-7 11-2

el 18 de julio de 2025 a las 11:14 AM (CDT) BAJO EL MISMO.

MADERA

TABLE 2308.11.2(4)—RAFTER SPANS FOR COMMON LUMBER SPECIES
(Allowable stress design ground snow load, p = 50 psf, ceiling not attached to rafters, L/Δ = 180)—continued
g(asd)
Col2 Col3 Col4 Col5 Col6 Col7 Col8 Col9 Col10 Col11 Col12 Col13
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
(ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.)
19.2—
continued
Southern
Pine
SS 7-1 11-2 14-8 18-3 21-7 7-1 11-2 14-2 16-11 20-0
19.2—
continued
Southern
Pine
#1 6-6 9-8 12-3 14-4 17-1 6-0 9-0 11-4 13-4 15-9
19.2—
continued
Southern
Pine
#2 5-7 8-4 10-7 12-6 14-9 5-2 7-9 9-9 11-7 13-8
19.2—
continued
Southern
Pine
#3 4-3 6-4 8-0 9-8 11-5 4-0 5-10 7-4 8-11 10-7
19.2—
continued
Spruce-
Pine-Fir
SS 6-8 10-6 13-5 16-5 19-1 6-8 9-10 12-5 15-3 17-8
19.2—
continued
Spruce-
Pine-Fir
#1 6-1 8-11 11-3 13-9 15-11 5-7 8-3 10-5 12-9 14-9
19.2—
continued
Spruce-
Pine-Fir
#2 6-1 8-11 11-3 13-9 15-11 5-7 8-3 10-5 12-9 14-9
19.2—
continued
Spruce-
Pine-Fir
#3 4-7 6-9 8-6 10-5 12-1 4-3 6-3 7-11 9-7 11-2
24 Douglas
Fir-Larch
SS 6-8 10-3 13-0 15-10 18-4 6-6 9-6 12-0 14-8 17-0
24 Douglas
Fir-Larch
#1 5-10 8-6 10-9 13-2 15-3 5-5 7-10 10-0 12-2 14-1
24 Douglas
Fir-Larch
#2 5-5 7-11 10-1 12-4 14-3 5-0 7-4 9-4 11-5 13-2
24 Douglas
Fir-Larch
#3 4-1 6-0 7-7 9-4 10-9 3-10 5-7 7-1 8-7 10-0
24 Hem-Fir SS 6-4 9-11 12-9 15-7 18-0 6-4 9-4 11-9 14-5 16-8
24 Hem-Fir #1 5-8 8-3 10-6 12-10 14-10 5-3 7-8 9-9 11-10 13-9
24 Hem-Fir #2 5-4 7-10 9-11 12-1 14-1 4-11 7-3 9-2 11-3 13-0
24 Hem-Fir #3 4-1 6-0 7-7 9-4 10-9 3-10 5-7 7-1 8-7 10-0
24 Southern
Pine
SS 6-7 10-4 13-8 16-4 19-3 6-7 10-0 12-8 15-2 17-10
24 Southern
Pine
#1 5-10 8-8 11-0 12-10 15-3 5-5 8-0 10-2 11-11 14-1
24 Southern
Pine
#2 5-0 7-5 9-5 11-3 13-2 4-7 6-11 8-9 10-5 12-3
24 Southern
Pine
#3 3-10 5-8 7-1 8-8 10-3 3-6 5-3 6-7 8-0 9-6
24 Spruce-
Pine-Fir
SS 6-2 9-6 12-0 14-8 17-1 6-0 8-10 11-2 13-7 15-9
24 Spruce-
Pine-Fir
#1 5-5 7-11 10-1 12-4 14-3 5-0 7-4 9-4 11-5 13-2
24 Spruce-
Pine-Fir
#2 5-5 7-11 10-1 12-4 14-3 5-0 7-4 9-4 11-5 13-2
24 Spruce-
Pine-Fir
#3 4-1 6-0 7-7 9-4 10-9 3-10 5-7 7-1 8-7 10-0
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.

23-70 CÓDIGO DE CONSTRUCCIÓN DE CALIFORNIA 2025

el 18 de julio de 2025 11:14 AM (CDT) BAJO EL MISMO.

MADERA

TABLE 2308.11.2(5)—RAFTER SPANS FOR COMMON LUMBER SPECIES
(Allowable stress design ground snow load, p = 30 psf, ceiling attached to rafters, L/Δ = 240)
g(asd)
Col2 Col3 Col4 Col5 Col6 Col7 Col8 Col9 Col10 Col11 Col12 Col13
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
(ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.)
12 Douglas
Fir-Larch
SS 9-1 14-4 18-10 24-1 Note b 9-1 14-4 18-10 24-1 Note b
12 Douglas
Fir-Larch
#1 8-9 13-9 18-2 22-9 Note b 8-9 13-2 16-8 20-4 23-7
12 Douglas
Fir-Larch
#2 8-7 13-6 17-5 21-4 24-8 8-5 12-4 15-7 19-1 22-1
12 Douglas
Fir-Larch
#3 7-1 10-5 13-2 16-1 18-8 6-4 9-4 11-9 14-5 16-8
12 Hem-Fir SS 8-7 13-6 17-10 22-9 Note b 8-7 13-6 17-10 22-9 Note b
12 Hem-Fir #1 8-5 13-3 17-5 22-2 25-9 8-5 12-10 16-3 19-10 23-0
12 Hem-Fir #2 8-0 12-7 16-7 21-0 24-4 8-0 12-2 15-4 18-9 21-9
12 Hem-Fir #3 7-1 10-5 13-2 16-1 18-8 6-4 9-4 11-9 14-5 16-8
12 Southern
Pine
SS 8-11 14-1 18-6 23-8 Note b 8-11 14-1 18-6 23-8 Note b
12 Southern
Pine
#1 8-7 13-6 17-10 22-3 Note b 8-7 13-5 17-0 19-11 23-7
12 Southern
Pine
#2 8-3 12-11 16-4 19-5 22-10 7-8 11-7 14-8 17-4 20-5
12 Southern
Pine
#3 6-7 9-9 12-4 15-0 17-9 5-11 8-9 11-0 13-5 15-10
12 Spruce-
Pine-Fir
SS 8-5 13-3 17-5 22-3 Note b 8-5 13-3 17-5 22-3 Note b
12 Spruce-
Pine-Fir
#1 8-3 12-11 17-0 21-4 24-8 8-3 12-4 15-7 19-1 22-1
12 Spruce-
Pine-Fir
#2 8-3 12-11 17-0 21-4 24-8 8-3 12-4 15-7 19-1 22-1
12 Spruce-
Pine-Fir
#3 7-1 10-5 13-2 16-1 18-8 6-4 9-4 11-9 14-5 16-8
16 Douglas
Fir-Larch
SS 8-3 13-0 17-2 21-10 Note b 8-3 13-0 17-2 21-3 24-8
16 Douglas
Fir-Larch
#1 8-0 12-6 16-2 19-9 22-10 7-10 11-5 14-5 17-8 20-5
16 Douglas
Fir-Larch
#2 7-10 11-11 15-1 18-5 21-5 7-3 10-8 13-6 16-6 19-2
16 Douglas
Fir-Larch
#3 6-2 9-0 11-5 13-11 16-2 5-6 8-1 10-3 12-6 14-6
16 Hem-Fir SS 7-10 12-3 16-2 20-8 25-1 7-10 12-3 16-2 20-8 24-2
16 Hem-Fir #1 7-8 12-0 15-9 19-3 22-3 7-7 11-1 14-1 17-2 19-11
16 Hem-Fir #2 7-3 11-5 14-11 18-2 21-1 7-2 10-6 13-4 16-3 18-10
16 Hem-Fir #3 6-2 9-0 11-5 13-11 16-2 5-6 8-1 10-3 12-6 14-6
16 Southern
Pine
SS 8-1 12-9 16-10 21-6 Note b 8-1 12-9 16-10 21-6 25-11
16 Southern
Pine
#1 7-10 12-3 16-2 19-3 22-10 7-10 11-7 14-9 17-3 20-5
16 Southern
Pine
#2 7-6 11-2 14-2 16-10 19-10 6-8 10-0 12-8 15-1 17-9
16 Southern
Pine
#3 5-9 8-6 10-8 13-0 15-4 5-2 7-7 9-7 11-7 13-9

el 18 de julio de 2025 a las 11:14 AM (CDT) BAJO EL MISMO.

MADERA

TABLE 2308.11.2(5)—RAFTER SPANS FOR COMMON LUMBER SPECIES
(Allowable stress design ground snow load, p = 30 psf, ceiling attached to rafters, L/Δ = 240)
g(asd)
Col2 Col3 Col4 Col5 Col6 Col7 Col8 Col9 Col10 Col11 Col12 Col13
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
(ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.)
16—
continued
Spruce-
Pine-Fir
SS 7-8 12-0 15-10 20-2 24-7 7-8 12-0 15-10 19-9 22-10
16—
continued
Spruce-
Pine-Fir
#1 7-6 11-9 15-1 18-5 21-5 7-3 10-8 13-6 16-6 19-2
16—
continued
Spruce-
Pine-Fir
#2 7-6 11-9 15-1 18-5 21-5 7-3 10-8 13-6 16-6 19-2
16—
continued
Spruce-
Pine-Fir
#3 6-2 9-0 11-5 13-11 16-2 5-6 8-1 10-3 12-6 14-6
19.2 Douglas
Fir-Larch
SS 7-9 12-3 16-1 20-7 25-0 7-9 12-3 15-10 19-5 22-6
19.2 Douglas
Fir-Larch
#1 7-6 11-8 14-9 18-0 20-11 7-1 10-5 13-2 16-1 18-8
19.2 Douglas
Fir-Larch
#2 7-4 10-11 13-9 16-10 19-6 6-8 9-9 12-4 15-1 17-6
19.2 Douglas
Fir-Larch
#3 5-7 8-3 10-5 12-9 14-9 5-0 7-4 9-4 11-5 13-2
19.2 Hem-Fir SS 7-4 11-7 15-3 19-5 23-7 7-4 11-7 15-3 19-1 22-1
19.2 Hem-Fir #1 7-2 11-4 14-4 17-7 20-4 6-11 10-2 12-10 15-8 18-2
19.2 Hem-Fir #2 6-10 10-9 13-7 16-7 19-3 6-7 9-7 12-2 14-10 17-3
19.2 Hem-Fir #3 5-7 8-3 10-5 12-9 14-9 5-0 7-4 9-4 11-5 13-2
19.2 Southern
Pine
SS 7-8 12-0 15-10 20-2 24-7 7-8 12-0 15-10 20-0 23-7
19.2 Southern
Pine
#1 7-4 11-7 15-1 17-7 20-11 7-1 10-7 13-5 15-9 18-8
19.2 Southern
Pine
#2 6-10 10-2 12-11 15-4 18-1 6-1 9-2 11-7 13-9 16-2
19.2 Southern
Pine
#3 5-3 7-9 9-9 11-10 14-0 4-8 6-11 8-9 10-7 12-6
19.2 Spruce-
Pine-Fir
SS 7-2 11-4 14-11 19-0 23-1 7-2 11-4 14-9 18-0 20-11
19.2 Spruce-
Pine-Fir
#1 7-0 10-11 13-9 16-10 19-6 6-8 9-9 12-4 15-1 17-6
19.2 Spruce-
Pine-Fir
#2 7-0 10-11 13-9 16-10 19-6 6-8 9-9 12-4 15-1 17-6
19.2 Spruce-
Pine-Fir
#3 5-7 8-3 10-5 12-9 14-9 5-0 7-4 9-4 11-5 13-2
24 Douglas
Fir-Larch
SS 7-3 11-4 15-0 19-1 22-6 7-3 11-3 14-2 17-4 20-1
24 Douglas
Fir-Larch
#1 7-0 10-5 13-2 16-1 18-8 6-4 9-4 11-9 14-5 16-8
24 Douglas
Fir-Larch
#2 6-8 9-9 12-4 15-1 17-6 5-11 8-8 11-0 13-6 15-7
24 Douglas
Fir-Larch
#3 5-0 7-4 9-4 11-5 13-2 4-6 6-7 8-4 10-2 11-10
24 Hem-Fir SS 6-10 10-9 14-2 18-0 21-11 6-10 10-9 13-11 17-0 19-9
24 Hem-Fir #1 6-8 10-2 12-10 15-8 18-2 6-2 9-1 11-6 14-0 16-3
24 Hem-Fir #2 6-4 9-7 12-2 14-10 17-3 5-10 8-7 10-10 13-3 15-5
24 Hem-Fir #3 5-0 7-4 9-4 11-5 13-2 4-6 6-7 8-4 10-2 11-10

23-72 CÓDIGO DE CONSTRUCCIÓN DE CALIFORNIA 2025

el 18 de julio de 2025 11:14 AM (CDT) BAJO EL MISMO.

MADERA

TABLE 2308.11.2(5)—RAFTER SPANS FOR COMMON LUMBER SPECIES
(Allowable stress design ground snow load, p = 30 psf, ceiling attached to rafters, L/Δ = 240)
g(asd)
Col2 Col3 Col4 Col5 Col6 Col7 Col8 Col9 Col10 Col11 Col12 Col13
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
(ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.)
24—
continued
Southern
Pine
SS 7-1 11-2 14-8 18-9 22-10 7-1 11-2 14-8 17-11 21-2
24—
continued
Southern
Pine
#1 6-10 10-7 13-5 15-9 18-8 6-4 9-6 12-0 14-1 16-8
24—
continued
Southern
Pine
#2 6-1 9-2 11-7 13-9 16-2 5-5 8-2 10-4 12-3 14-6
24—
continued
Southern
Pine
#3 4-8 6-11 8-9 10-7 12-6 4-2 6-2 7-10 9-6 11-2
24—
continued
Spruce-
Pine-Fir
SS 6-8 10-6 13-10 17-8 20-11 6-8 10-5 13-2 16-1 18-8
24—
continued
Spruce-
Pine-Fir
#1 6-6 9-9 12-4 15-1 17-6 5-11 8-8 11-0 13-6 15-7
24—
continued
Spruce-
Pine-Fir
#2 6-6 9-9 12-4 15-1 17-6 5-11 8-8 11-0 13-6 15-7
24—
continued
Spruce-
Pine-Fir
#3 5-0 7-4 9-4 11-5 13-2 4-6 6-7 8-4 10-2 11-10
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
b. Span exceeds 26 feet in length.
TABLE 2308.11.2(6)—RAFTER SPANS FOR COMMON LUMBER SPECIES
(Allowable stress design ground snow load, p = 50 psf, ceiling attached to rafters, L/Δ = 240)
g(asd)
Col2 Col3 Col4 Col5 Col6 Col7 Col8 Col9 Col10 Col11 Col12 Col13
--- --- --- --- --- --- --- --- --- --- --- --- ---
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
(ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.)
12 Douglas
Fir-Larch
SS 7-8 12-1 15-11 20-3 24-8 7-8 12-1 15-11 20-3 24-0
12 Douglas
Fir-Larch
#1 7-5 11-7 15-3 18-7 21-7 7-5 11-2 14-1 17-3 20-0
12 Douglas
Fir-Larch
#2 7-3 11-3 14-3 17-5 20-2 7-1 10-5 13-2 16-1 18-8
12 Douglas
Fir-Larch
#3 5-10 8-6 10-9 13-2 15-3 5-5 7-10 10-0 12-2 14-1
12 Hem-Fir SS 7-3 11-5 15-0 19-2 23-4 7-3 11-5 15-0 19-2 23-4
12 Hem-Fir #1 7-1 11-2 14-8 18-1 21-0 7-1 10-10 13-9 16-9 19-5
12 Hem-Fir #2 6-9 10-8 14-0 17-2 19-11 6-9 10-3 13-0 15-10 18-5
12 Hem-Fir #3 5-10 8-6 10-9 13-2 15-3 5-5 7-10 10-0 12-2 14-1
12 Southern
Pine
SS 7-6 11-10 15-7 19-11 24-3 7-6 11-10 15-7 19-11 24-3
12 Southern
Pine
#1 7-3 11-5 15-0 18-2 21-7 7-3 11-4 14-5 16-10 20-0
12 Southern
Pine
#2 6-11 10-6 13-4 15-10 18-8 6-6 9-9 12-4 14-8 17-3
12 Southern
Pine
#3 5-5 8-0 10-1 12-3 14-6 5-0 7-5 9-4 11-4 13-5

el 18 de julio de 2025 11:14 AM (CDT) BAJO EL MISMO.

MADERA

TABLE 2308.11.2(6)—RAFTER SPANS FOR COMMON LUMBER SPECIES
(Allowable stress design ground snow load, p = 50 psf, ceiling attached to rafters, L/Δ = 240)—continued
g(asd)
Col2 Col3 Col4 Col5 Col6 Col7 Col8 Col9 Col10 Col11 Col12 Col13
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
(ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.)
12—
continued
Spruce-
Pine-Fir
SS 7-1 11-2 14-8 18-9 22-10 7-1 11-2 14-8 18-9 22-4
12—
continued
Spruce-
Pine-Fir
#1 6-11 10-11 14-3 17-5 20-2 6-11 10-5 13-2 16-1 18-8
12—
continued
Spruce-
Pine-Fir
#2 6-11 10-11 14-3 17-5 20-2 6-11 10-5 13-2 16-1 18-8
12—
continued
Spruce-
Pine-Fir
#3 5-10 8-6 10-9 13-2 15-3 5-5 7-10 10-0 12-2 14-1
16 Douglas
Fir-Larch
SS 7-0 11-0 14-5 18-5 22-5 7-0 11-0 14-5 17-11 20-10
16 Douglas
Fir-Larch
#1 6-9 10-5 13-2 16-1 18-8 6-7 9-8 12-2 14-11 17-3
16 Douglas
Fir-Larch
#2 6-7 9-9 12-4 15-1 17-6 6-2 9-0 11-5 13-11 16-2
16 Douglas
Fir-Larch
#3 5-0 7-4 9-4 11-5 13-2 4-8 6-10 8-8 10-6 12-3
16 Hem-Fir SS 6-7 10-4 13-8 17-5 21-2 6-7 10-4 13-8 17-5 20-5
16 Hem-Fir #1 6-5 10-2 12-10 15-8 18-2 6-5 9-5 11-11 14-6 16-10
16 Hem-Fir #2 6-2 9-7 12-2 14-10 17-3 6-1 8-11 11-3 13-9 15-11
16 Hem-Fir #3 5-0 7-4 9-4 11-5 13-2 4-8 6-10 8-8 10-6 12-3
16 Southern
Pine
SS 6-10 10-9 14-2 18-1 22-0 6-10 10-9 14-2 18-1 21-10
16 Southern
Pine
#1 6-7 10-4 13-5 15-9 18-8 6-7 9-10 12-5 14-7 17-3
16 Southern
Pine
#2 6-1 9-2 11-7 13-9 16-2 5-8 8-5 10-9 12-9 15-0
16 Southern
Pine
#3 4-8 6-11 8-9 10-7 12-6 4-4 6-5 8-1 9-10 11-7
16 Spruce-
Pine-Fir
SS 6-5 10-2 13-4 17-0 20-9 6-5 10-2 13-4 16-8 19-4
16 Spruce-
Pine-Fir
#1 6-4 9-9 12-4 15-1 17-6 6-2 9-0 11-5 13-11 16-2
16 Spruce-
Pine-Fir
#2 6-4 9-9 12-4 15-1 17-6 6-2 9-0 11-5 13-11 16-2
16 Spruce-
Pine-Fir
#3 5-0 7-4 9-4 11-5 13-2 4-8 6-10 8-8 10-6 12-3
19.2 Douglas
Fir-Larch
SS 6-7 10-4 13-7 17-4 20-6 6-7 10-4 13-5 16-5 19-0
19.2 Douglas
Fir-Larch
#1 6-4 9-6 12-0 14-8 17-1 6-0 8-10 11-2 13-7 15-9
19.2 Douglas
Fir-Larch
#2 6-1 8-11 11-3 13-9 15-11 5-7 8-3 10-5 12-9 14-9
19.2 Douglas
Fir-Larch
#3 4-7 6-9 8-6 10-5 12-1 4-3 6-3 7-11 9-7 11-2
19.2 Hem-Fir SS 6-2 9-9 12-10 16-5 19-11 6-2 9-9 12-10 16-1 18-8
19.2 Hem-Fir #1 6-1 9-3 11-9 14-4 16-7 5-10 8-7 10-10 13-3 15-5
19.2 Hem-Fir #2 5-9 8-9 11-1 13-7 15-9 5-7 8-1 10-3 12-7 14-7
19.2 Hem-Fir #3 4-7 6-9 8-6 10-5 12-1 4-3 6-3 7-11 9-7 11-2

23-74 CÓDIGO DE CONSTRUCCIÓN DE CALIFORNIA 2025

el 18 de julio de 2025 11:14 AM (CDT) BAJO EL MISMO.

MADERA

TABLE 2308.11.2(6)—RAFTER SPANS FOR COMMON LUMBER SPECIES
(Allowable stress design ground snow load, p = 50 psf, ceiling attached to rafters, L/Δ = 240)—continued
g(asd)
Col2 Col3 Col4 Col5 Col6 Col7 Col8 Col9 Col10 Col11 Col12 Col13
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 10 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf DEAD LOAD = 20 psf
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa Maximum rafter spansa
RAFTER
SPACING
(inches)
SPECIES AND
GRADE
SPECIES AND
GRADE
(ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.)
19.2—
continued
Southern
Pine
SS 6-5 10-2 13-4 17-0 20-9 6-5 10-2 13-4 16-11 20-0
19.2—
continued
Southern
Pine
#1 6-2 9-8 12-3 14-4 17-1 6-0 9-0 11-4 13-4 15-9
19.2—
continued
Southern
Pine
#2 5-7 8-4 10-7 12-6 14-9 5-2 7-9 9-9 11-7 13-8
19.2—
continued
Southern
Pine
#3 4-3 6-4 8-0 9-8 11-5 4-0 5-10 7-4 8-11 10-7
19.2—
continued
Spruce-
Pine-Fir
SS 6-1 9-6 12-7 16-0 19-1 6-1 9-6 12-5 15-3 17-8
19.2—
continued
Spruce-
Pine-Fir
#1 5-11 8-11 11-3 13-9 15-11 5-7 8-3 10-5 12-9 14-9
19.2—
continued
Spruce-
Pine-Fir
#2 5-11 8-11 11-3 13-9 15-11 5-7 8-3 10-5 12-9 14-9
19.2—
continued
Spruce-
Pine-Fir
#3 4-7 6-9 8-6 10-5 12-1 4-3 6-3 7-11 9-7 11-2
24 Douglas
Fir-Larch
SS 6-1 9-7 12-7 15-10 18-4 6-1 9-6 12-0 14-8 17-0
24 Douglas
Fir-Larch
#1 5-10 8-6 10-9 13-2 15-3 5-5 7-10 10-0 12-2 14-1
24 Douglas
Fir-Larch
#2 5-5 7-11 10-1 12-4 14-3 5-0 7-4 9-4 11-5 13-2
24 Douglas
Fir-Larch
#3 4-1 6-0 7-7 9-4 10-9 3-10 5-7 7-1 8-7 10-0
24 Hem-Fir SS 5-9 9-1 11-11 15-2 18-0 5-9 9-1 11-9 14-5 15-11
24 Hem-Fir #1 5-8 8-3 10-6 12-10 14-10 5-3 7-8 9-9 11-10 13-9
24 Hem-Fir #2 5-4 7-10 9-11 12-1 14-1 4-11 7-3 9-2 11-3 13-0
24 Hem-Fir #3 4-1 6-0 7-7 9-4 10-9 3-10 5-7 7-1 8-7 10-0
24 Southern
Pine
SS 6-0 9-5 12-5 15-10 19-3 6-0 9-5 12-5 15-2 17-10
24 Southern
Pine
#1 5-9 8-8 11-0 12-10 15-3 5-5 8-0 10-2 11-11 14-1
24 Southern
Pine
#2 5-0 7-5 9-5 11-3 13-2 4-7 6-11 8-9 10-5 12-3
24 Southern
Pine
#3 3-10 5-8 7-1 8-8 10-3 3-6 5-3 6-7 8-0 9-6
24 Spruce-
Pine-Fir
SS 5-8 8-10 11-8 14-8 17-1 5-8 8-10 11-2 13-7 15-9
24 Spruce-
Pine-Fir
#1 5-5 7-11 10-1 12-4 14-3 5-0 7-4 9-4 11-5 13-2
24 Spruce-
Pine-Fir
#2 5-5 7-11 10-1 12-4 14-3 5-0 7-4 9-4 11-5 13-2
24 Spruce-
Pine-Fir
#3 4-1 6-0 7-7 9-4 10-9 3-10 5-7 7-1 8-7 10-0
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the
bearing walls, such as rafter ties, is provided at that location. Where ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall be multiplied by the
adjustment factors in Table 2308.11.2(7).

el 18 de julio de 2025 11:14 AM (CDT) BAJO EL MISMO.

MADERA

TABLE 2308.11.2(7)—RAFTER SPAN ADJUSTMENT FACTOR Col2
HC/****HR
a
RAFTER SPAN ADJUSTMENT FACTOR
1/3 0.67
1/4 0.76
1/5 0.83
1/6 0.90
1/7.5 or less 1.00
a._ HC_ = Height of ceiling joists or rafter ties measured vertically above the top of the rafter support walls;HR = Height of roof ridge measured vertically above the top of the rafter
support walls.
a._ HC_ = Height of ceiling joists or rafter ties measured vertically above the top of the rafter support walls;HR = Height of roof ridge measured vertically above the top of the rafter
support walls.

2308.11.3 Estructura de vigas de techo y cabios. Los cabios deberán estar estructurados directamente opuestos entre sí en la cumbrera. Deberá haber una tabla de cumbrera de un espesor nominal no menor a 1 pulgada (25 mm) en las cumbreras y no menor en profundidad que el extremo cortado del cabio. En los valles y caderas, deberá haber un solo cabio de valle o cadera con un espesor nominal no menor a 2 pulgadas (51 mm) y no menor en profundidad que el extremo cortado del cabio.

2308.11.3.1 Conexiones de vigas de techo y cabios. Las vigas de techo y los cabios deberán clavarse entre sí y el conjunto deberá clavarse a la placa superior del muro conforme a las Tablas 2304.10.2 y 2308.11.4. Las vigas de techo deberán ser continuas o unidas de forma segura donde se encuentren sobre tabiques interiores y fijarse a los cabios adyacentes conforme a las Tablas 2304.10.2 y 2308.11.3.1 para proporcionar una atadura continua de cabios a lo largo del edificio cuando dichas vigas sean paralelas a los cabios. Las vigas de techo deberán tener una superficie de apoyo no menor a 1 [1] / 2 pulgadas (38 mm) sobre la placa superior en cada extremo.

Cuando las vigas de techo no sean paralelas a los cabios, se deberá instalar una atadura equivalente de cabios de manera que proporcione una atadura continua a lo largo del edificio, con un espaciamiento no mayor a 4 pies (1219 mm) en el centro. Las conexiones deberán cumplir con las Tablas 2308.11.3.1 y 2304.10.2, o se deberán proporcionar conexiones de capacidades equivalentes. Cuando no se proporcionen vigas de techo o ataduras de cabios en la parte superior de los muros de soporte de cabios, la cumbrera formada por estos cabios deberá estar soportada por una viga conforme a las Secciones 2308.3 y 2308.4. Las ataduras de cabios deberán espaciarse no más de 4 pies (1219 mm) en el centro.

Las conexiones de ataduras de cabios deberán basarse en el espaciamiento equivalente de cabios en la Tabla 2308.11.3.1. Las conexiones cabio-a-viga de techo y las conexiones de ataduras de cabios deberán ser de tamaño y número suficientes para evitar que se partan por el clavado.

La conexión de los elementos estructurales del techo a las líneas de muros arriostrados deberá cumplir con la Sección 2308.10.7.2.

TABLE 2308.11.3.1—RAFTER TIE CONNECTIONSi Col2 Col3 Col4 Col5 Col6 Col7 Col8 Col9 Col10 Col11
RAFTER
SLOPE
TIE
SPACING
(inches)
LIVE LOAD ONLYg LIVE LOAD ONLYg LIVE LOAD ONLYg ALLOWABLE STRESS DESIGN GROUND SNOW LOAD,****pg(asd)
(pounds per square foot)
ALLOWABLE STRESS DESIGN GROUND SNOW LOAD,****pg(asd)
(pounds per square foot)
ALLOWABLE STRESS DESIGN GROUND SNOW LOAD,****pg(asd)
(pounds per square foot)
ALLOWABLE STRESS DESIGN GROUND SNOW LOAD,****pg(asd)
(pounds per square foot)
ALLOWABLE STRESS DESIGN GROUND SNOW LOAD,****pg(asd)
(pounds per square foot)
ALLOWABLE STRESS DESIGN GROUND SNOW LOAD,****pg(asd)
(pounds per square foot)
RAFTER
SLOPE
TIE
SPACING
(inches)
LIVE LOAD ONLYg LIVE LOAD ONLYg LIVE LOAD ONLYg 30 pounds per square foot 30 pounds per square foot 30 pounds per square foot 50 pounds per square foot 50 pounds per square foot 50 pounds per square foot
RAFTER
SLOPE
TIE
SPACING
(inches)
Roof span (feet) Roof span (feet) Roof span (feet) Roof span (feet) Roof span (feet) Roof span (feet) Roof span (feet) Roof span (feet) Roof span (feet)
RAFTER
SLOPE
TIE
SPACING
(inches)
12 24 36 12 24 36 12 24 36
RAFTER
SLOPE
TIE
SPACING
(inches)
Required number of 16d common (31/2" x 0.162") nails per connectiona, b, c, d, e, f, h Required number of 16d common (31/2" x 0.162") nails per connectiona, b, c, d, e, f, h Required number of 16d common (31/2" x 0.162") nails per connectiona, b, c, d, e, f, h Required number of 16d common (31/2" x 0.162") nails per connectiona, b, c, d, e, f, h Required number of 16d common (31/2" x 0.162") nails per connectiona, b, c, d, e, f, h Required number of 16d common (31/2" x 0.162") nails per connectiona, b, c, d, e, f, h Required number of 16d common (31/2" x 0.162") nails per connectiona, b, c, d, e, f, h Required number of 16d common (31/2" x 0.162") nails per connectiona, b, c, d, e, f, h Required number of 16d common (31/2" x 0.162") nails per connectiona, b, c, d, e, f, h
3:12 12 3 5 8 3 6 9 5 9 13
3:12 16 4 7 10 4 8 12 6 12 17
3:12 19.2 4 8 12 5 10 14 7 14 21
3:12 24 5 10 15 6 12 18 9 17 26
3:12 32 7 13 20 8 16 24 12 23 34
3:12 48 10 20 29 12 24 35 17 34 51
4:12 12 3 4 6 3 5 7 4 7 10
4:12 16 3 5 8 3 6 9 5 9 13
4:12 19.2 3 6 9 4 7 11 6 11 16
4:12 24 4 8 11 5 9 13 7 13 19
4:12 32 5 10 15 6 12 18 9 17 26
4:12 48 8 15 22 9 18 26 13 26 38
5:12 12 3 3 5 3 4 6 3 6 8
5:12 16 3 4 6 3 5 7 4 7 11
5:12 19.2 3 5 7 3 6 9 5 9 13
5:12 24 3 6 9 4 7 11 6 11 16

23-76 CÓDIGO DE CONSTRUCCIÓN DE CALIFORNIA 2025

el 18 de julio de 2025 11:14 AM (CDT) BAJO EL MISMO.

MADERA

TABLE 2308.11.3.1—RAFTER TIE CONNECTIONSi—continued Col2 Col3 Col4 Col5 Col6 Col7 Col8 Col9 Col10 Col11
RAFTER
SLOPE
TIE
SPACING
(inches)
LIVE LOAD ONLYg LIVE LOAD ONLYg LIVE LOAD ONLYg ALLOWABLE STRESS DESIGN GROUND SNOW LOAD,****pg(asd)
(pounds per square foot)
ALLOWABLE STRESS DESIGN GROUND SNOW LOAD,****pg(asd)
(pounds per square foot)
ALLOWABLE STRESS DESIGN GROUND SNOW LOAD,****pg(asd)
(pounds per square foot)
ALLOWABLE STRESS DESIGN GROUND SNOW LOAD,****pg(asd)
(pounds per square foot)
ALLOWABLE STRESS DESIGN GROUND SNOW LOAD,****pg(asd)
(pounds per square foot)
ALLOWABLE STRESS DESIGN GROUND SNOW LOAD,****pg(asd)
(pounds per square foot)
RAFTER
SLOPE
TIE
SPACING
(inches)
LIVE LOAD ONLYg LIVE LOAD ONLYg LIVE LOAD ONLYg 30 pounds per square foot 30 pounds per square foot 30 pounds per square foot 50 pounds per square foot 50 pounds per square foot 50 pounds per square foot
RAFTER
SLOPE
TIE
SPACING
(inches)
Roof span (feet) Roof span (feet) Roof span (feet) Roof span (feet) Roof span (feet) Roof span (feet) Roof span (feet) Roof span (feet) Roof span (feet)
RAFTER
SLOPE
TIE
SPACING
(inches)
12 24 36 12 24 36 12 24 36
RAFTER
SLOPE
TIE
SPACING
(inches)
Required number of 16d common (31/2" x 0.162") nails per connectiona, b, c, d, e, f, h Required number of 16d common (31/2" x 0.162") nails per connectiona, b, c, d, e, f, h Required number of 16d common (31/2" x 0.162") nails per connectiona, b, c, d, e, f, h Required number of 16d common (31/2" x 0.162") nails per connectiona, b, c, d, e, f, h Required number of 16d common (31/2" x 0.162") nails per connectiona, b, c, d, e, f, h Required number of 16d common (31/2" x 0.162") nails per connectiona, b, c, d, e, f, h Required number of 16d common (31/2" x 0.162") nails per connectiona, b, c, d, e, f, h Required number of 16d common (31/2" x 0.162") nails per connectiona, b, c, d, e, f, h Required number of 16d common (31/2" x 0.162") nails per connectiona, b, c, d, e, f, h
5:12—
continued
32 4 8 12 5 10 14 7 14 21
5:12—
continued
48 6 12 18 7 14 21 11 21 31
7:12 12 3 3 4 3 3 4 3 4 6
7:12 16 3 3 5 3 4 5 3 5 8
7:12 19.2 3 4 5 3 4 6 3 6 9
7:12 24 3 5 7 3 5 8 4 8 11
7:12 32 3 6 9 4 7 10 5 10 15
7:12 48 5 9 13 5 10 15 8 15 22
9:12 12 3 3 3 3 3 3 3 3 5
9:12 16 3 3 4 3 3 4 3 4 6
9:12 19.2 3 3 4 3 4 5 3 5 7
9:12 24 3 4 5 3 4 6 3 6 9
9:12 32 3 5 7 3 6 8 4 8 12
9:12 48 4 7 10 4 8 12 6 12 17
12:12 12 3 3 3 3 3 3 3 3 4
12:12 16 3 3 3 3 3 3 3 3 5
12:12 19.2 3 3 3 3 3 4 3 4 6
12:12 24 3 3 4 3 3 5 3 5 7
12:12 32 3 4 5 3 4 6 3 6 9
12:12 48 3 5 8 3 6 9 5 9 13
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 47.8 N/m2.
a. 10d common (3_″_ × 0.148_″_) nails shall be permitted to be substituted for 16d common (31/2″ × 0.162″) nails where the required number of nails is taken as 1.2 times the required
number of 16d common nails, rounded up to the next full nail.
b. Rafter tie heel joint connections are not required where the ridge is supported by a load-bearing wall, header or ridge beam.
c. Where intermediate support of the rafter is provided by vertical struts or purlins to a load-bearing wall, the tabulated heel joint connection requirements are permitted to be
reduced proportionally to the reduction in span.
d. Equivalent nailing patterns are required for ceiling joist to ceiling joist lap splices.
e. Connected members shall be of sufficient size to prevent splitting due to nailing.
f. For allowable stress design snow loads less than 30 pounds per square foot, the required number of nails is permitted to be reduced by multiplying by the ratio of actual snow
load plus 10 divided by 40, but not less than the number required for no snow load.
g. Applies to roof live load of 20 psf or less.
h. Tabulated heel joint connection requirements assume that ceiling joists or rafter ties are located at the bottom of the attic space. Where ceiling joists or rafter ties are located
higher in the attic, heel joint connection requirements shall be increased by the adjustment factors in Table 2308.11.3.1(1).
i. Tabulated requirements are based on 10 psf roof dead load in combination with the specified roof snow load and roof live load.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 47.8 N/m2.
a. 10d common (3_″_ × 0.148_″_) nails shall be permitted to be substituted for 16d common (31/2″ × 0.162″) nails where the required number of nails is taken as 1.2 times the required
number of 16d common nails, rounded up to the next full nail.
b. Rafter tie heel joint connections are not required where the ridge is supported by a load-bearing wall, header or ridge beam.
c. Where intermediate support of the rafter is provided by vertical struts or purlins to a load-bearing wall, the tabulated heel joint connection requirements are permitted to be
reduced proportionally to the reduction in span.
d. Equivalent nailing patterns are required for ceiling joist to ceiling joist lap splices.
e. Connected members shall be of sufficient size to prevent splitting due to nailing.
f. For allowable stress design snow loads less than 30 pounds per square foot, the required number of nails is permitted to be reduced by multiplying by the ratio of actual snow
load plus 10 divided by 40, but not less than the number required for no snow load.
g. Applies to roof live load of 20 psf or less.
h. Tabulated heel joint connection requirements assume that ceiling joists or rafter ties are located at the bottom of the attic space. Where ceiling joists or rafter ties are located
higher in the attic, heel joint connection requirements shall be increased by the adjustment factors in Table 2308.11.3.1(1).
i. Tabulated requirements are based on 10 psf roof dead load in combination with the specified roof snow load and roof live load.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 47.8 N/m2.
a. 10d common (3_″_ × 0.148_″_) nails shall be permitted to be substituted for 16d common (31/2″ × 0.162″) nails where the required number of nails is taken as 1.2 times the required
number of 16d common nails, rounded up to the next full nail.
b. Rafter tie heel joint connections are not required where the ridge is supported by a load-bearing wall, header or ridge beam.
c. Where intermediate support of the rafter is provided by vertical struts or purlins to a load-bearing wall, the tabulated heel joint connection requirements are permitted to be
reduced proportionally to the reduction in span.
d. Equivalent nailing patterns are required for ceiling joist to ceiling joist lap splices.
e. Connected members shall be of sufficient size to prevent splitting due to nailing.
f. For allowable stress design snow loads less than 30 pounds per square foot, the required number of nails is permitted to be reduced by multiplying by the ratio of actual snow
load plus 10 divided by 40, but not less than the number required for no snow load.
g. Applies to roof live load of 20 psf or less.
h. Tabulated heel joint connection requirements assume that ceiling joists or rafter ties are located at the bottom of the attic space. Where ceiling joists or rafter ties are located
higher in the attic, heel joint connection requirements shall be increased by the adjustment factors in Table 2308.11.3.1(1).
i. Tabulated requirements are based on 10 psf roof dead load in combination with the specified roof snow load and roof live load.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 47.8 N/m2.
a. 10d common (3_″_ × 0.148_″_) nails shall be permitted to be substituted for 16d common (31/2″ × 0.162″) nails where the required number of nails is taken as 1.2 times the required
number of 16d common nails, rounded up to the next full nail.
b. Rafter tie heel joint connections are not required where the ridge is supported by a load-bearing wall, header or ridge beam.
c. Where intermediate support of the rafter is provided by vertical struts or purlins to a load-bearing wall, the tabulated heel joint connection requirements are permitted to be
reduced proportionally to the reduction in span.
d. Equivalent nailing patterns are required for ceiling joist to ceiling joist lap splices.
e. Connected members shall be of sufficient size to prevent splitting due to nailing.
f. For allowable stress design snow loads less than 30 pounds per square foot, the required number of nails is permitted to be reduced by multiplying by the ratio of actual snow
load plus 10 divided by 40, but not less than the number required for no snow load.
g. Applies to roof live load of 20 psf or less.
h. Tabulated heel joint connection requirements assume that ceiling joists or rafter ties are located at the bottom of the attic space. Where ceiling joists or rafter ties are located
higher in the attic, heel joint connection requirements shall be increased by the adjustment factors in Table 2308.11.3.1(1).
i. Tabulated requirements are based on 10 psf roof dead load in combination with the specified roof snow load and roof live load.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 47.8 N/m2.
a. 10d common (3_″_ × 0.148_″_) nails shall be permitted to be substituted for 16d common (31/2″ × 0.162″) nails where the required number of nails is taken as 1.2 times the required
number of 16d common nails, rounded up to the next full nail.
b. Rafter tie heel joint connections are not required where the ridge is supported by a load-bearing wall, header or ridge beam.
c. Where intermediate support of the rafter is provided by vertical struts or purlins to a load-bearing wall, the tabulated heel joint connection requirements are permitted to be
reduced proportionally to the reduction in span.
d. Equivalent nailing patterns are required for ceiling joist to ceiling joist lap splices.
e. Connected members shall be of sufficient size to prevent splitting due to nailing.
f. For allowable stress design snow loads less than 30 pounds per square foot, the required number of nails is permitted to be reduced by multiplying by the ratio of actual snow
load plus 10 divided by 40, but not less than the number required for no snow load.
g. Applies to roof live load of 20 psf or less.
h. Tabulated heel joint connection requirements assume that ceiling joists or rafter ties are located at the bottom of the attic space. Where ceiling joists or rafter ties are located
higher in the attic, heel joint connection requirements shall be increased by the adjustment factors in Table 2308.11.3.1(1).
i. Tabulated requirements are based on 10 psf roof dead load in combination with the specified roof snow load and roof live load.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 47.8 N/m2.
a. 10d common (3_″_ × 0.148_″_) nails shall be permitted to be substituted for 16d common (31/2″ × 0.162″) nails where the required number of nails is taken as 1.2 times the required
number of 16d common nails, rounded up to the next full nail.
b. Rafter tie heel joint connections are not required where the ridge is supported by a load-bearing wall, header or ridge beam.
c. Where intermediate support of the rafter is provided by vertical struts or purlins to a load-bearing wall, the tabulated heel joint connection requirements are permitted to be
reduced proportionally to the reduction in span.
d. Equivalent nailing patterns are required for ceiling joist to ceiling joist lap splices.
e. Connected members shall be of sufficient size to prevent splitting due to nailing.
f. For allowable stress design snow loads less than 30 pounds per square foot, the required number of nails is permitted to be reduced by multiplying by the ratio of actual snow
load plus 10 divided by 40, but not less than the number required for no snow load.
g. Applies to roof live load of 20 psf or less.
h. Tabulated heel joint connection requirements assume that ceiling joists or rafter ties are located at the bottom of the attic space. Where ceiling joists or rafter ties are located
higher in the attic, heel joint connection requirements shall be increased by the adjustment factors in Table 2308.11.3.1(1).
i. Tabulated requirements are based on 10 psf roof dead load in combination with the specified roof snow load and roof live load.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 47.8 N/m2.
a. 10d common (3_″_ × 0.148_″_) nails shall be permitted to be substituted for 16d common (31/2″ × 0.162″) nails where the required number of nails is taken as 1.2 times the required
number of 16d common nails, rounded up to the next full nail.
b. Rafter tie heel joint connections are not required where the ridge is supported by a load-bearing wall, header or ridge beam.
c. Where intermediate support of the rafter is provided by vertical struts or purlins to a load-bearing wall, the tabulated heel joint connection requirements are permitted to be
reduced proportionally to the reduction in span.
d. Equivalent nailing patterns are required for ceiling joist to ceiling joist lap splices.
e. Connected members shall be of sufficient size to prevent splitting due to nailing.
f. For allowable stress design snow loads less than 30 pounds per square foot, the required number of nails is permitted to be reduced by multiplying by the ratio of actual snow
load plus 10 divided by 40, but not less than the number required for no snow load.
g. Applies to roof live load of 20 psf or less.
h. Tabulated heel joint connection requirements assume that ceiling joists or rafter ties are located at the bottom of the attic space. Where ceiling joists or rafter ties are located
higher in the attic, heel joint connection requirements shall be increased by the adjustment factors in Table 2308.11.3.1(1).
i. Tabulated requirements are based on 10 psf roof dead load in combination with the specified roof snow load and roof live load.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 47.8 N/m2.
a. 10d common (3_″_ × 0.148_″_) nails shall be permitted to be substituted for 16d common (31/2″ × 0.162″) nails where the required number of nails is taken as 1.2 times the required
number of 16d common nails, rounded up to the next full nail.
b. Rafter tie heel joint connections are not required where the ridge is supported by a load-bearing wall, header or ridge beam.
c. Where intermediate support of the rafter is provided by vertical struts or purlins to a load-bearing wall, the tabulated heel joint connection requirements are permitted to be
reduced proportionally to the reduction in span.
d. Equivalent nailing patterns are required for ceiling joist to ceiling joist lap splices.
e. Connected members shall be of sufficient size to prevent splitting due to nailing.
f. For allowable stress design snow loads less than 30 pounds per square foot, the required number of nails is permitted to be reduced by multiplying by the ratio of actual snow
load plus 10 divided by 40, but not less than the number required for no snow load.
g. Applies to roof live load of 20 psf or less.
h. Tabulated heel joint connection requirements assume that ceiling joists or rafter ties are located at the bottom of the attic space. Where ceiling joists or rafter ties are located
higher in the attic, heel joint connection requirements shall be increased by the adjustment factors in Table 2308.11.3.1(1).
i. Tabulated requirements are based on 10 psf roof dead load in combination with the specified roof snow load and roof live load.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 47.8 N/m2.
a. 10d common (3_″_ × 0.148_″_) nails shall be permitted to be substituted for 16d common (31/2″ × 0.162″) nails where the required number of nails is taken as 1.2 times the required
number of 16d common nails, rounded up to the next full nail.
b. Rafter tie heel joint connections are not required where the ridge is supported by a load-bearing wall, header or ridge beam.
c. Where intermediate support of the rafter is provided by vertical struts or purlins to a load-bearing wall, the tabulated heel joint connection requirements are permitted to be
reduced proportionally to the reduction in span.
d. Equivalent nailing patterns are required for ceiling joist to ceiling joist lap splices.
e. Connected members shall be of sufficient size to prevent splitting due to nailing.
f. For allowable stress design snow loads less than 30 pounds per square foot, the required number of nails is permitted to be reduced by multiplying by the ratio of actual snow
load plus 10 divided by 40, but not less than the number required for no snow load.
g. Applies to roof live load of 20 psf or less.
h. Tabulated heel joint connection requirements assume that ceiling joists or rafter ties are located at the bottom of the attic space. Where ceiling joists or rafter ties are located
higher in the attic, heel joint connection requirements shall be increased by the adjustment factors in Table 2308.11.3.1(1).
i. Tabulated requirements are based on 10 psf roof dead load in combination with the specified roof snow load and roof live load.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 47.8 N/m2.
a. 10d common (3_″_ × 0.148_″_) nails shall be permitted to be substituted for 16d common (31/2″ × 0.162″) nails where the required number of nails is taken as 1.2 times the required
number of 16d common nails, rounded up to the next full nail.
b. Rafter tie heel joint connections are not required where the ridge is supported by a load-bearing wall, header or ridge beam.
c. Where intermediate support of the rafter is provided by vertical struts or purlins to a load-bearing wall, the tabulated heel joint connection requirements are permitted to be
reduced proportionally to the reduction in span.
d. Equivalent nailing patterns are required for ceiling joist to ceiling joist lap splices.
e. Connected members shall be of sufficient size to prevent splitting due to nailing.
f. For allowable stress design snow loads less than 30 pounds per square foot, the required number of nails is permitted to be reduced by multiplying by the ratio of actual snow
load plus 10 divided by 40, but not less than the number required for no snow load.
g. Applies to roof live load of 20 psf or less.
h. Tabulated heel joint connection requirements assume that ceiling joists or rafter ties are located at the bottom of the attic space. Where ceiling joists or rafter ties are located
higher in the attic, heel joint connection requirements shall be increased by the adjustment factors in Table 2308.11.3.1(1).
i. Tabulated requirements are based on 10 psf roof dead load in combination with the specified roof snow load and roof live load.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 47.8 N/m2.
a. 10d common (3_″_ × 0.148_″_) nails shall be permitted to be substituted for 16d common (31/2″ × 0.162″) nails where the required number of nails is taken as 1.2 times the required
number of 16d common nails, rounded up to the next full nail.
b. Rafter tie heel joint connections are not required where the ridge is supported by a load-bearing wall, header or ridge beam.
c. Where intermediate support of the rafter is provided by vertical struts or purlins to a load-bearing wall, the tabulated heel joint connection requirements are permitted to be
reduced proportionally to the reduction in span.
d. Equivalent nailing patterns are required for ceiling joist to ceiling joist lap splices.
e. Connected members shall be of sufficient size to prevent splitting due to nailing.
f. For allowable stress design snow loads less than 30 pounds per square foot, the required number of nails is permitted to be reduced by multiplying by the ratio of actual snow
load plus 10 divided by 40, but not less than the number required for no snow load.
g. Applies to roof live load of 20 psf or less.
h. Tabulated heel joint connection requirements assume that ceiling joists or rafter ties are located at the bottom of the attic space. Where ceiling joists or rafter ties are located
higher in the attic, heel joint connection requirements shall be increased by the adjustment factors in Table 2308.11.3.1(1).
i. Tabulated requirements are based on 10 psf roof dead load in combination with the specified roof snow load and roof live load.
TABLE 2308.11.3.1(1)—HEEL JOINT CONNECTION ADJUSTMENT FACTORS Col2
--- ---
HC/****HR
a, b
HEEL JOINT CONNECTION ADJUSTMENT FACTOR
1/3 1.5
1/4 1.33
1/5 1.25
1/6 1.2
1/10 or less 1.11
a._ HC_ = Height of ceiling joists or rafter ties measured vertically from the top of the rafter support walls to the bottom of the ceiling joists or rafter ties;HR = Height of roof ridge
measured vertically from the top of the rafter support walls to the bottom of the roof ridge.
b. Where_HC_/HR exceeds 1/3, connections shall be designed in accordance with accepted engineering practice.
a._ HC_ = Height of ceiling joists or rafter ties measured vertically from the top of the rafter support walls to the bottom of the ceiling joists or rafter ties;HR = Height of roof ridge
measured vertically from the top of the rafter support walls to the bottom of the roof ridge.
b. Where_HC_/HR exceeds 1/3, connections shall be designed in accordance with accepted engineering practice.

el 18 de julio de 2025 11:14 AM (CDT) BAJO EL MISMO.

MADERA

2308.11.4 Elevación por viento. La construcción del techo deberá tener amarres de vigas y cerchas a la pared inferior. Las cargas resultantes de elevación deberán transferirse a la cimentación mediante un camino de carga continuo. La conexión de la viga o cercha a la pared deberá cumplir con las Tablas 2304.10.2 y 2308.11.4.

Excepción: La conexión de la cercha a la pared se determinará a partir de las fuerzas de elevación especificadas en los planos de diseño de la cercha o según se indique en los documentos de construcción.

TABLE 2308.11.4—REQUIRED RATING OF APPROVED UPLIFT CONNECTORS (pounds)a, b, c, e, f, g, h, d Col2 Col3 Col4 Col5 Col6 Col7 Col8
BASIC WINDSPEED,****V i, (mph) ROOF SPAN (feet) ROOF SPAN (feet) ROOF SPAN (feet) ROOF SPAN (feet) ROOF SPAN (feet) ROOF SPAN (feet) ROOF SPAN (feet)
BASIC WINDSPEED,****V i, (mph) 12 20 24 28 32 36 40
EXPOSURE B EXPOSURE B EXPOSURE B EXPOSURE B EXPOSURE B EXPOSURE B EXPOSURE B EXPOSURE B
90 -64 -85 -96 -107 -117 -128 -139
100 -102 -139 -158 -177 -195 -214 -233
110 -144 -199 -226 -254 -282 -310 -338
120 -190 -265 -302 -339 -377 -414 -452
130 -240 -335 -382 -431 -479 -528 -576
140 -294 -411 -470 -530 -590 -650 -710
EXPOSURE C EXPOSURE C EXPOSURE C EXPOSURE C EXPOSURE C EXPOSURE C EXPOSURE C EXPOSURE C
90 -126 -175 -199 -223 -247 -272 -296
100 -179 -250 -285 -320 -356 -391 -426
110 -238 -332 -380 -428 -476 -525 -573
120 -302 -424 -485 -547 -608 -669 -731
130 -371 -521 -597 -674 -751 -828 -904
140 -446 -628 -719 -812 -904 -997 -1090
EXPOSURE D EXPOSURE D EXPOSURE D EXPOSURE D EXPOSURE D EXPOSURE D EXPOSURE D EXPOSURE D
90 -166 -232 -265 -298 -311 -364 -396
100 -229 -321 -367 -413 -459 -505 -551
110 -298 -418 -478 -539 -601 -662 -723
120 -373 -526 -603 -679 -756 -833 -910
130 -455 -641 -734 -829 -924 -1020 -1114
140 -544 -767 -878 -992 -1106 -1220 -1333
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 1.61 km/hr, 1 pound = 0.454 Kg, 1 pound/foot = 14.5939 N/m.
a. The uplift connection requirements are based on a 33-foot mean roof height.
b. The uplift connection requirements are based on the framing being spaced 24 inches on center. Multiply by 0.67 for framing spaced 16 inches on center and multiply by 0.5 for
framing spaced 12 inches on center.
c. The uplift connection requirements include an allowance for 10 pounds of dead load.
d. The uplift connection requirements include for the effects of 24-inch overhangs.
e. The uplift connection requirements are based on wind loading on end zones as defined in Figure 28.3-1 of ASCE 7. Connection loads for connections located a distance of 20
percent of the least horizontal dimension of the building from the corner of the building are permitted to be reduced by multiplying the table connection value by 0.75.
f. For wall-to-wall and wall-to-foundation connections, the capacity of the uplift connector is permitted to be reduced by 100 pounds for each full wall above. (For example, if a
500-pound rated connector is used on the roof framing, a 400-pound rated connector is permitted at the next floor level down).
g. Interpolation is permitted for intermediate values of_V_ and roof spans.
h. The rated capacity of approved tie-down devices is permitted to include up to a 60-percent increase for wind effects where allowed by material specifications. The required
rating of approved uplift connectors is based on allowable stress design loads.
i._ V_ shall be determined in accordance with Section 1609.3.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 1.61 km/hr, 1 pound = 0.454 Kg, 1 pound/foot = 14.5939 N/m.
a. The uplift connection requirements are based on a 33-foot mean roof height.
b. The uplift connection requirements are based on the framing being spaced 24 inches on center. Multiply by 0.67 for framing spaced 16 inches on center and multiply by 0.5 for
framing spaced 12 inches on center.
c. The uplift connection requirements include an allowance for 10 pounds of dead load.
d. The uplift connection requirements include for the effects of 24-inch overhangs.
e. The uplift connection requirements are based on wind loading on end zones as defined in Figure 28.3-1 of ASCE 7. Connection loads for connections located a distance of 20
percent of the least horizontal dimension of the building from the corner of the building are permitted to be reduced by multiplying the table connection value by 0.75.
f. For wall-to-wall and wall-to-foundation connections, the capacity of the uplift connector is permitted to be reduced by 100 pounds for each full wall above. (For example, if a
500-pound rated connector is used on the roof framing, a 400-pound rated connector is permitted at the next floor level down).
g. Interpolation is permitted for intermediate values of_V_ and roof spans.
h. The rated capacity of approved tie-down devices is permitted to include up to a 60-percent increase for wind effects where allowed by material specifications. The required
rating of approved uplift connectors is based on allowable stress design loads.
i._ V_ shall be determined in accordance with Section 1609.3.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 1.61 km/hr, 1 pound = 0.454 Kg, 1 pound/foot = 14.5939 N/m.
a. The uplift connection requirements are based on a 33-foot mean roof height.
b. The uplift connection requirements are based on the framing being spaced 24 inches on center. Multiply by 0.67 for framing spaced 16 inches on center and multiply by 0.5 for
framing spaced 12 inches on center.
c. The uplift connection requirements include an allowance for 10 pounds of dead load.
d. The uplift connection requirements include for the effects of 24-inch overhangs.
e. The uplift connection requirements are based on wind loading on end zones as defined in Figure 28.3-1 of ASCE 7. Connection loads for connections located a distance of 20
percent of the least horizontal dimension of the building from the corner of the building are permitted to be reduced by multiplying the table connection value by 0.75.
f. For wall-to-wall and wall-to-foundation connections, the capacity of the uplift connector is permitted to be reduced by 100 pounds for each full wall above. (For example, if a
500-pound rated connector is used on the roof framing, a 400-pound rated connector is permitted at the next floor level down).
g. Interpolation is permitted for intermediate values of_V_ and roof spans.
h. The rated capacity of approved tie-down devices is permitted to include up to a 60-percent increase for wind effects where allowed by material specifications. The required
rating of approved uplift connectors is based on allowable stress design loads.
i._ V_ shall be determined in accordance with Section 1609.3.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 1.61 km/hr, 1 pound = 0.454 Kg, 1 pound/foot = 14.5939 N/m.
a. The uplift connection requirements are based on a 33-foot mean roof height.
b. The uplift connection requirements are based on the framing being spaced 24 inches on center. Multiply by 0.67 for framing spaced 16 inches on center and multiply by 0.5 for
framing spaced 12 inches on center.
c. The uplift connection requirements include an allowance for 10 pounds of dead load.
d. The uplift connection requirements include for the effects of 24-inch overhangs.
e. The uplift connection requirements are based on wind loading on end zones as defined in Figure 28.3-1 of ASCE 7. Connection loads for connections located a distance of 20
percent of the least horizontal dimension of the building from the corner of the building are permitted to be reduced by multiplying the table connection value by 0.75.
f. For wall-to-wall and wall-to-foundation connections, the capacity of the uplift connector is permitted to be reduced by 100 pounds for each full wall above. (For example, if a
500-pound rated connector is used on the roof framing, a 400-pound rated connector is permitted at the next floor level down).
g. Interpolation is permitted for intermediate values of_V_ and roof spans.
h. The rated capacity of approved tie-down devices is permitted to include up to a 60-percent increase for wind effects where allowed by material specifications. The required
rating of approved uplift connectors is based on allowable stress design loads.
i._ V_ shall be determined in accordance with Section 1609.3.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 1.61 km/hr, 1 pound = 0.454 Kg, 1 pound/foot = 14.5939 N/m.
a. The uplift connection requirements are based on a 33-foot mean roof height.
b. The uplift connection requirements are based on the framing being spaced 24 inches on center. Multiply by 0.67 for framing spaced 16 inches on center and multiply by 0.5 for
framing spaced 12 inches on center.
c. The uplift connection requirements include an allowance for 10 pounds of dead load.
d. The uplift connection requirements include for the effects of 24-inch overhangs.
e. The uplift connection requirements are based on wind loading on end zones as defined in Figure 28.3-1 of ASCE 7. Connection loads for connections located a distance of 20
percent of the least horizontal dimension of the building from the corner of the building are permitted to be reduced by multiplying the table connection value by 0.75.
f. For wall-to-wall and wall-to-foundation connections, the capacity of the uplift connector is permitted to be reduced by 100 pounds for each full wall above. (For example, if a
500-pound rated connector is used on the roof framing, a 400-pound rated connector is permitted at the next floor level down).
g. Interpolation is permitted for intermediate values of_V_ and roof spans.
h. The rated capacity of approved tie-down devices is permitted to include up to a 60-percent increase for wind effects where allowed by material specifications. The required
rating of approved uplift connectors is based on allowable stress design loads.
i._ V_ shall be determined in accordance with Section 1609.3.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 1.61 km/hr, 1 pound = 0.454 Kg, 1 pound/foot = 14.5939 N/m.
a. The uplift connection requirements are based on a 33-foot mean roof height.
b. The uplift connection requirements are based on the framing being spaced 24 inches on center. Multiply by 0.67 for framing spaced 16 inches on center and multiply by 0.5 for
framing spaced 12 inches on center.
c. The uplift connection requirements include an allowance for 10 pounds of dead load.
d. The uplift connection requirements include for the effects of 24-inch overhangs.
e. The uplift connection requirements are based on wind loading on end zones as defined in Figure 28.3-1 of ASCE 7. Connection loads for connections located a distance of 20
percent of the least horizontal dimension of the building from the corner of the building are permitted to be reduced by multiplying the table connection value by 0.75.
f. For wall-to-wall and wall-to-foundation connections, the capacity of the uplift connector is permitted to be reduced by 100 pounds for each full wall above. (For example, if a
500-pound rated connector is used on the roof framing, a 400-pound rated connector is permitted at the next floor level down).
g. Interpolation is permitted for intermediate values of_V_ and roof spans.
h. The rated capacity of approved tie-down devices is permitted to include up to a 60-percent increase for wind effects where allowed by material specifications. The required
rating of approved uplift connectors is based on allowable stress design loads.
i._ V_ shall be determined in accordance with Section 1609.3.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 1.61 km/hr, 1 pound = 0.454 Kg, 1 pound/foot = 14.5939 N/m.
a. The uplift connection requirements are based on a 33-foot mean roof height.
b. The uplift connection requirements are based on the framing being spaced 24 inches on center. Multiply by 0.67 for framing spaced 16 inches on center and multiply by 0.5 for
framing spaced 12 inches on center.
c. The uplift connection requirements include an allowance for 10 pounds of dead load.
d. The uplift connection requirements include for the effects of 24-inch overhangs.
e. The uplift connection requirements are based on wind loading on end zones as defined in Figure 28.3-1 of ASCE 7. Connection loads for connections located a distance of 20
percent of the least horizontal dimension of the building from the corner of the building are permitted to be reduced by multiplying the table connection value by 0.75.
f. For wall-to-wall and wall-to-foundation connections, the capacity of the uplift connector is permitted to be reduced by 100 pounds for each full wall above. (For example, if a
500-pound rated connector is used on the roof framing, a 400-pound rated connector is permitted at the next floor level down).
g. Interpolation is permitted for intermediate values of_V_ and roof spans.
h. The rated capacity of approved tie-down devices is permitted to include up to a 60-percent increase for wind effects where allowed by material specifications. The required
rating of approved uplift connectors is based on allowable stress design loads.
i._ V_ shall be determined in accordance with Section 1609.3.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 1.61 km/hr, 1 pound = 0.454 Kg, 1 pound/foot = 14.5939 N/m.
a. The uplift connection requirements are based on a 33-foot mean roof height.
b. The uplift connection requirements are based on the framing being spaced 24 inches on center. Multiply by 0.67 for framing spaced 16 inches on center and multiply by 0.5 for
framing spaced 12 inches on center.
c. The uplift connection requirements include an allowance for 10 pounds of dead load.
d. The uplift connection requirements include for the effects of 24-inch overhangs.
e. The uplift connection requirements are based on wind loading on end zones as defined in Figure 28.3-1 of ASCE 7. Connection loads for connections located a distance of 20
percent of the least horizontal dimension of the building from the corner of the building are permitted to be reduced by multiplying the table connection value by 0.75.
f. For wall-to-wall and wall-to-foundation connections, the capacity of the uplift connector is permitted to be reduced by 100 pounds for each full wall above. (For example, if a
500-pound rated connector is used on the roof framing, a 400-pound rated connector is permitted at the next floor level down).
g. Interpolation is permitted for intermediate values of_V_ and roof spans.
h. The rated capacity of approved tie-down devices is permitted to include up to a 60-percent increase for wind effects where allowed by material specifications. The required
rating of approved uplift connectors is based on allowable stress design loads.
i._ V_ shall be determined in accordance with Section 1609.3.

2308.11.5 Estructura alrededor de aberturas. Las vigas de refuerzo y las vigas cabeceras deberán ser dobles, o de madera con sección transversal equivalente, cuando el vano de la viga cabecera exceda de 4 pies (1219 mm). Los extremos de las vigas cabeceras que tengan más de 6 pies (1829 mm) de longitud deberán estar soportados por anclajes de estructura o colgadores de vigas, a menos que descansen sobre una viga, tabique o muro.

2308.11.5.1 Aberturas en diafragmas de techo en Categorías de Diseño Sísmico B, C, D y E. En edificios clasificados en Categoría de Diseño Sísmico B, C, D o E, las aberturas en diafragmas horizontales con una dimensión mayor a 4 pies (1219 mm) deberán construirse con ataduras metálicas y bloqueos conforme a esta sección y la Figura 2308.8.4.1(1). Las ataduras metálicas deberán tener un espesor no menor a 0.058 pulgadas [1.47 mm (calibre galvanizado 16)] por 1 1/2 pulgadas (38 mm) de ancho y deberán tener un esfuerzo de fluencia no menor a 33,000 psi (227 MPa). El bloqueo deberá extenderse no menos que la dimensión de la abertura en la dirección de la atadura y el bloqueo. Las ataduras deberán fijarse al bloqueo conforme a las instrucciones del fabricante, pero con no menos de ocho clavos comunes 16d en cada lado de la intersección viga-cabecera.

2308.11.6 Correas. Se permite instalar correas para soportar cargas del techo con el fin de reducir el vano de las vigas dentro de los límites permitidos y deberán estar soportadas por puntales hacia muros de carga. El vano máximo de correas de 2 pulgadas por 4 pulgadas (51 mm por 102 mm) será de 4 pies (1219 mm). El vano máximo de correas de 2 pulgadas por 6 pulgadas (51 mm por 152 mm) será de 6 pies (1829 mm), pero la correa no deberá ser más pequeña que la viga que soporta. Los puntales deberán ser miembros no menores a 2 pulgadas por 4 pulgadas (51 mm por 102 mm). La

23-78 CÓDIGO DE CONSTRUCCIÓN DE CALIFORNIA 2025

el 18 de julio de 2025 11:14 AM (CDT) SEGÚN LO DISPUESTO.

MADERA

longitud sin arriostrar de los puntales no deberá exceder de 8 pies (2438 mm) y la inclinación de los puntales no deberá ser menor a 45 grados (0.79 rad) respecto a la horizontal.

2308.11.7 Bloqueo. Las vigas del techo y las vigas del cielo raso deberán estar soportadas lateralmente para evitar rotación y desplazamiento lateral conforme a la Sección 2308.8.6 y conectadas a líneas de muro arriostrado conforme a la Sección 2308.10.7.2.

2308.11.8 Productos de madera estructurada. Las vigas I prefabricadas de madera, la madera laminada estructuralmente encolada y la madera compuesta estructural no deberán ser entalladas ni perforadas, salvo cuando lo permitan las recomendaciones del fabricante o cuando los efectos de tales alteraciones sean considerados específicamente en el diseño del elemento por un profesional registrado en diseño.

2308.11.9 Revestimiento del techo. El revestimiento del techo deberá cumplir con las Tablas 2304.8(3) y 2304.8(5) para paneles estructurales de madera, y las Tablas 2304.8(1) y 2304.8(2) para madera aserrada, y deberá cumplir con la Sección 2304.8.2.

2308.11.10 Juntas. Las juntas en el revestimiento de madera deberán ubicarse sobre soportes, salvo que se utilice madera con machihembrado aprobado, en cuyo caso cada pieza deberá descansar sobre no menos de dos soportes.

2308.11.11 Entablado del techo. El entablado deberá diseñarse conforme a las disposiciones generales de este código.

En lugar de dicho diseño, se permite entablado machihembrado de 2 pulgadas (51 mm) conforme a la Tabla 2308.11.11. Se permite que las juntas en dicho entablado estén espaciadas aleatoriamente, siempre que el sistema se aplique a no menos de tres vanos continuos, las tablas estén machihembradas por el centro y por los extremos o con espigas, cada tabla descanse sobre uno o más soportes, y las juntas estén separadas por no menos de 24 pulgadas (610 mm) en piezas adyacentes.

TABLE 2308.11.11—ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING Col2 Col3 Col4 Col5
SPANa
(feet)
LIVE LOAD
(pounds per square foot)
DEFLECTION LIMIT BENDING STRESS (f)
(pounds per square inch)
MODULUS OF ELASTICITY (E)
(pounds per square inch)
Roofs Roofs Roofs Roofs Roofs
4 20 1/240
1/360
160 170,000
256,000
4 30 1/240
1/360
210 256,000
384,000
4 40 1/240
1/360
270 340,000
512,000
4.5 20 1/240
1/360
200 242,000
305,000
4.5 30 1/240
1/360
270 363,000
405,000
4.5 40 1/240
1/360
350 484,000
725,000
5.0 20 1/240
1/360
250 332,000
500,000
5.0 30 1/240
1/360
330 495,000
742,000
5.0 40 1/240
1/360
420 660,000
1,000,000
5.5 20 1/240
1/360
300 442,000
660,000
5.5 30 1/240
1/360
400 662,000
998,000
5.5 40 1/240
1/360
500 884,000
1,330,000
6.0 20 1/240
1/360
360 575,000
862,000
6.0 30 1/240
1/360
480 862,000
1,295,000
6.0 40 1/240
1/360
600 1,150,000
1,730,000

el 18 de julio de 2025 11:14 AM (CDT) BAJO EL MISMO.

MADERA

TABLE 2308.11.11—ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING—continued Col2 Col3 Col4 Col5
SPANa
(feet)
LIVE LOAD
(pounds per square foot)
DEFLECTION LIMIT BENDING STRESS (f)
(pounds per square inch)
MODULUS OF ELASTICITY (E)
(pounds per square inch)
6.5 20 1/240
1/360
420 595,000
892,000
6.5 30 1/240
1/360
560 892,000
1,340,000
6.5 40 1/240
1/360
700 1,190,000
1,730,000
7.0 20 1/240
1/360
490 910,000
1,360,000
7.0 30 1/240
1/360
650 1,370,000
2,000,000
7.0 40 1/240
1/360
810 1,820,000
2,725,000
7.5 20 1/240
1/360
560 1,125,000
1,685,000
7.5 30 1/240
1/360
750 1,685,000
2,530,000
7.5 40 1/240
1/360
930 2,250,000
3,380,000
8.0 20 1/240
1/360
640 1,360,000
2,040,000
8.0 30 1/240
1/360
850 2,040,000
3,060,000
Floors Floors Floors Floors Floors
4
4.5
5.0
40 1/360 840
950
1,060
1,000,000
1,300,000
1,600,000
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kN/m2, 1 pound per square inch = 0.00689 N/mm2.
a. Spans are based on simple beam action with 10 pounds per square foot dead load and provisions for a 300-pound concentrated load on a 12-inch width of decking. Random
layup is permitted in accordance with the provisions of Section 2308.11.11. Lumber thickness is 11/2 inches nominal.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kN/m2, 1 pound per square inch = 0.00689 N/mm2.
a. Spans are based on simple beam action with 10 pounds per square foot dead load and provisions for a 300-pound concentrated load on a 12-inch width of decking. Random
layup is permitted in accordance with the provisions of Section 2308.11.11. Lumber thickness is 11/2 inches nominal.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kN/m2, 1 pound per square inch = 0.00689 N/mm2.
a. Spans are based on simple beam action with 10 pounds per square foot dead load and provisions for a 300-pound concentrated load on a 12-inch width of decking. Random
layup is permitted in accordance with the provisions of Section 2308.11.11. Lumber thickness is 11/2 inches nominal.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kN/m2, 1 pound per square inch = 0.00689 N/mm2.
a. Spans are based on simple beam action with 10 pounds per square foot dead load and provisions for a 300-pound concentrated load on a 12-inch width of decking. Random
layup is permitted in accordance with the provisions of Section 2308.11.11. Lumber thickness is 11/2 inches nominal.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kN/m2, 1 pound per square inch = 0.00689 N/mm2.
a. Spans are based on simple beam action with 10 pounds per square foot dead load and provisions for a 300-pound concentrated load on a 12-inch width of decking. Random
layup is permitted in accordance with the provisions of Section 2308.11.11. Lumber thickness is 11/2 inches nominal.

2308.11.12 Cerchas de madera. Las cerchas de madera deberán diseñarse de conformidad con la Sección 2303.4. La conexión a las líneas de muro arriostrado deberá realizarse conforme a la Sección 2308.10.7.2.

2308.11.13 Ventilación del ático. Para la ventilación del ático, véase la Sección 1202.2.1.