Section J104 — PERMIT APPLICATION AND SUBMITTALS
J104.3 Replace the exception as follows:
San Francisco Building Inspection Commission Codes · 2022 edition · ingested 2026-07-08 · San Francisco
J104.3 Replace the exception as follows:
Exception: [ ← ] Grading conforming to all of the following requirements:
No cut section is greater than 10 feet (3.048 m) in vertical height.
No cut slope is steeper than 2 horizontal to 1 vertical.
The tops of cut banks are separated from any structure or major improvement by a distance, measured horizontally, equal to not less than the height of the bank.
Not more than 5,000 cubic yards (3825 m [3] ) shall be involved in grading.
Grading performed at a site outside the limits of known slide areas.
All other grading shall require soils report and the grading plans shall include, but not limited to, the following information:
(1) The design of retaining walls or other structures used to support cuts or fills. Such retaining walls or structures, except when part of a building, may be constructed under this permit, provided the cost of same is included in the valuation shown on the application.
(2) The sequencing of cut and fill operations in a manner that assures interim stability of the site.