Section 504C — SYMBOLS AND NOTATIONS
504C.1 For the purpose of this chapter, the applicable symbols and notations in this code shall apply.
San Francisco Building Inspection Commission Codes · 2022 edition · ingested 2026-07-08 · San Francisco
504C.1 For the purpose of this chapter, the applicable symbols and notations in this code shall apply.
A = cross sectional area of unreinforced masonry pier or wall, square inches.
Ab = total area of the bed joints above and below the test specimen for each in-place shear test.
Cp = numerical coefficient as specified in Table 5C-C for Special Procedure diaphragm shear transfer.
D = in-plane width dimension of pier, inches, or depth of diaphragm, feet.
DCR = demand-capacity ratio specified in Section 511C.4.2.
Fwx = force applied to a wall at level x, pounds.
H = least clear height of opening on either side of a pier, inches.
h/t = height-to-thickness ratio of an unreinforced masonry wall. Height, h, is measured between wall anchorage levels and/or slab-on-grade.
L = span of diaphragm between shear walls, or span between shear wall and open front, feet.
Lo = length of crosswall, feet.
Li = effective span for an open front building specified in Section 511C.8, feet.
PD = superimposed dead load at the location under consideration, pounds. For determination of the rocking shear capacity, dead load at the top of the pier under consideration shall be used.
PD+L = stress resulting from the dead plus actual live load in place at the time of testing, pounds per square inch (psi).
Pw = weight of wall, pounds.
Va = vaA, the allowable shear in any unreinforced masonry pier, pounds.
Vca = total shear capacity of crosswalls in the direction of analysis immediately above the diaphragm level being investigated, åvcLo, pounds.
Vcb = total shear capacity of crosswalls in the direction of analysis immediately below the diaphragm level being investigated, åvcLo, pounds.
Vp = shear force assigned to a pier on the basis of its relative shear rigidity, pounds.
Vr = pier rocking shear capacity of any unreinforced masonry wall or wall pier, pounds.
Vtest = load at incipient cracking for each in-place shear test per Section 514C, pounds.
Vwx = total shear force resisted by a shear wall at the level under consideration, pounds.
va = allowable shear stress for unreinforced masonry, pounds per square inch (psi).
vc = allowable shear value for a crosswall sheathed with any of the materials given in Table 5C-D or 5C-E, pounds per foot.
vt = mortar shear strength as specified in Section 506C.3.3.4, pounds per square inch (psi).
vto = mortar shear test values as specified in Section 506C.3.3.4, pounds per square inch (psi).
vu = allowable shear value for a diaphragm sheathed with any of the materials given in Table 5C-D or 5C-E, pounds per foot.
ΣvuD = sum of diaphragm shear capacities of both ends of the diaphragm, pounds.
ΣΣvuD = for diaphragms coupled with crosswalls, ΣΣvuD includes the sum of shear capacities of both ends of diaphragms coupled at and above the
level under consideration.
W = total seismic dead load as defined in San Francisco Building Code Chapter 16, pounds.
Wd = total dead load tributary to a diaphragm, pounds.
Σwd = total dead load to all the diaphragms at and above the level under consideration, pounds.
Ww = total dead load to an unreinforced masonry wall above the level under consideration or above an open front building, pounds.
W w x = dead load of an unreinforced masonry wall assigned to Level x halfway above and below the level under consideration, pounds.