Section 406 — MOTOR-VEHICLE-RELATED OCCUPANCIES

406.3 Add the following section:

San Francisco Building Inspection Commission Codes · 2022 edition · ingested 2026-07-08 · San Francisco

406.3 Add the following section:

406.3.4 Ventilation.

Ventilation shall be provided as follows: Natural ventilation shall be required, and such space shall be provided with ventilation outlets in the walls

or exterior doors. The total net area of such ventilation outlets shall be 200 square inches (0.129 m [2] ) for a space up to 1,000 square feet (92.903 m [2] ) in

area and shall be increased 30 square inches (0.0194 m [2] ) for each additional 200 square feet (18.58 m [2] ) of floor area up to maximum floor area of 3, 0 00 square feet (278.709 m [2] ).

GoCodebook provides limited public access, search, citation, multilingual explanation, and practical interpretation of legally adopted building regulations. It is not a substitute for the official ICC or California code publications.