Section 3107 — SIGNS

3107.4 Design.

San Francisco Building Inspection Commission Codes · 2022 edition · ingested 2026-07-08 · San Francisco

3107.4 Design.

The design shall make allowances for the effects of corrosion and lack of maintenance.

No anchor or support of any sign shall be connected to, or suspended by, an unbraced parapet wall, unless such wall is designed in accordance with the requirements for parapet walls specified in Chapter 16.

Fasteners and braces shall be of noncombustible construction, except that stringers for attachment of roof signs may be of 6-inch (152.4 mm) minimum dimension redwood or approved preservative-treated lumber.

GoCodebook provides limited public access, search, citation, multilingual explanation, and practical interpretation of legally adopted building regulations. It is not a substitute for the official ICC or California code publications.