24.05.130 PROPERTY DEVELOPMENT STANDARDS: C ZONES

Imperial Zoning Code · 2026-07 edition · ingested 2026-07-06 · Imperial

Prior to the construction of any building or structure on any lot within the C Zones a Site Plan Review is required, pursuant to Section 24.19.500. The following property development standards shall apply to all land and building permitted in their respective commercial zones. Any legal lot/parcel may be used as a building site, except no building permit shall be issues for any lot having lot size of less than 3,000 square feet. Each building site shall have a minimum 20-feet wide vehicular access to a public street.

The following requirements are minimums unless otherwise stated.

A. General Requirements C-1 C-2 VC
1. Lot area, sq. ft. or acres N/A N/A N/A
2. Lot width, in feet 50 60 25
3. Lot depth, in feet 135 100 100
4. Front yard setback, in feet 12 12 0
5. Side yard setback each side, in feet. Total of
combined side yard setbacks must equal 10
feet.
0/10 0/10 0
6. Side yard setback, street side, in feet 20 12 0

40

CITY OF IMPERIAL, CALIFORNIA ZONING ORDINANCE

A. General Requirements (cont.) C-1 C-2 VC
7. Rear yard, in feet 0 0 0
8. Side and rear yards abutting any residential
zones
20 20 0
9. Lot coverage, maximum 60% 60% 40%
10. Building height 35 feet maximum or three stories
whichever is less
11. Off-street parking
In all C-1 and C-2 Zones, all provisions of Section 24.13 shall apply. Within the VC
Zones, 50% percent of the required parking for the same use under Section 24.13 shall
apply. On-street parking and off-site parking may be counted towards the parking
requirement for all uses within the VC Zone.
12. Signs
In all C-1 and C-2 Zones, all provisions of Section 24.16 shall apply. Within the VC
Zones, Section 24.16 shall also apply, except that projecting signs and hanging signs
are permitted for ground floor uses. The size and location of projecting and hanging
signs shall be reviewed by the Downtown Review Committee.