Chapter 4 — PLUMBING FIXTURES AND FIXTURE FITTINGS
420.3 Pre-Rinse Spray Valve.
California Plumbing Code (Title 24, Part 5) · 2022 edition · updated 2026-09-12 · California
CBSC: official editions, supplements and errata
Italicized text is a California amendment to the model code, as printed in the official publication.
Commercial food service pre-rinse spray valves shall have a maximum flow rate of 1.6 gallons per minute (gpm) at 60 pounds-force per square inch (psi) (6.0 L/m at 414 kPa) and shall be equipped with an integral automatic shutoff.
420.3.1 Pre-Rinse Spray Valves. [BSC-CG, DSA- SS, HCD 1 & HCD 2] When installed, shall meet the requirements in the California Code of Regulations, Title 20 (Appliance Efficiency Regulations), Section 1605.1(h)(4) Table H-2, Section 1605.3(h)(4)(A), and
PLUMBING FIXTURES AND FIXTURE FITTINGS
Section 1607(d)(7), and shall be equipped with an inte- gral automatic shutoff. FOR REFERENCE ONLY: The following table and code section have been reprinted from the California Code of Regulations, Title 20 (Appliance Efficiency Regulations), Section 1605.1(h)(4) and Section 1605.3(h)(4)(A).
TABLE H-2 STANDARDS FOR COMMERCIAL PRE-RINSE SPRAY VALVES
MANUFACTURED ON OR AFTER JANUARY 28, 2019.
| PRODUCT CLASS (spray force in ounce force (ozf)) |
MAXIMUM FLOW RATE (gpm) |
|---|---|
Product Class 1 (≤ 5.0 ozf) |
1.00 |
Product Class 2 (> 5.0 ozf and≤ 8.0 ozf) |
1.20 |
Product Class 3 (> 8.0 ozf) |
1.28 |
Title 20 Section 1605.3(h)(4)(A): Commercial pre-rinse spray valves manufactured on or after January 1, 2006, shall have a minimum spray force of not less than 4.0 ounces-force (ozf) [113 grams-force (gf)].