420.3 Pre-Rinse Spray Valve.

California Plumbing Code (Title 24, Part 5) · 2022 edition · updated 2026-09-12 · California

CBSC: official editions, supplements and errata

Italicized text is a California amendment to the model code, as printed in the official publication.

Commercial food service pre-rinse spray valves shall have a maximum flow rate of 1.6 gallons per minute (gpm) at 60 pounds-force per square inch (psi) (6.0 L/m at 414 kPa) and shall be equipped with an integral automatic shutoff.

420.3.1 Pre-Rinse Spray Valves. [BSC-CG, DSA- SS, HCD 1 & HCD 2] When installed, shall meet the requirements in the California Code of Regulations, Title 20 (Appliance Efficiency Regulations), Section 1605.1(h)(4) Table H-2, Section 1605.3(h)(4)(A), and

PLUMBING FIXTURES AND FIXTURE FITTINGS

Section 1607(d)(7), and shall be equipped with an inte- gral automatic shutoff. FOR REFERENCE ONLY: The following table and code section have been reprinted from the California Code of Regulations, Title 20 (Appliance Efficiency Regulations), Section 1605.1(h)(4) and Section 1605.3(h)(4)(A).

TABLE H-2 STANDARDS FOR COMMERCIAL PRE-RINSE SPRAY VALVES

MANUFACTURED ON OR AFTER JANUARY 28, 2019.

PRODUCT CLASS
(spray force in ounce force (ozf))
MAXIMUM FLOW
RATE (gpm)

Product Class 1 (≤ 5.0 ozf)
1.00


Product Class 2 (> 5.0 ozf and≤ 8.0 ozf)
1.20

Product Class 3 (> 8.0 ozf)
1.28

Title 20 Section 1605.3(h)(4)(A): Commercial pre-rinse spray valves manufactured on or after January 1, 2006, shall have a minimum spray force of not less than 4.0 ounces-force (ozf) [113 grams-force (gf)].