Chapter 14 — FIRESTOP PROTECTION
California Plumbing Code (Title 24, Part 5) · 2022 edition · updated 2026-09-10 · California
Italicized text is a California amendment to the model code, as printed in the official publication.
Sections in this part
- 1401.1 Applicability.
- 1402.1 Penetrations.
- 1403.1 Materials. Firestop systems shall be installed in
- 1404.1 General Requirements. Combustible piping
- 1404.2 Fire-Resistance Rating.
- 1404.3 Firestop Systems. Penetrations shall be protected
- 1404.4 Connections. Where piping penetrates a rated
- 1404.5 Insulation and Coverings.
- 1404.6 Sleeves. Where sleeves are used, the sleeves shall
- 1405.1 General Requirements. Noncombustible piping
- 1405.2 Fire-Resistance Rating.
- 1405.3 Firestop Systems. Penetrations shall be protected
- 1405.4 Connections. Where piping penetrates a rated
- 1405.5 Unshielded Couplings. Unshielded couplings
- 1405.6 Sleeves. Where sleeves are used, the sleeves shall
- 1405.7 Insulation and Coverings.
- 1406.1 General.
- 1406.2 Examination. The Authority Having Jurisdiction
- 1406.3 Penetrations. The Authority Having Jurisdiction
- 1406.4 Field Installations.
(Matrix Adoption Tables are non-regulatory, intended only as an aid to the code user. See Chapter 1 for state agency authority and building applications.)
| Adopting Agency | BSC | BSC- CG |
SFM | HCD | DSA | OSHPD | BSCC | DPH | AGR | DWR | CEC | CA | SL | SLC | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Adopting Agency | **BSC ** | BSC- CG |
SFM | 1 | 2 | 1-AC | **AC ** | SS | SS/CC | 1 | 1R | 2 | 3 | 4 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 |
| Adopt Entire Chapter | X | **X ** | **X ** | **X ** | **X ** | **X ** | X | ||||||||||||||||
| Adopt Entire Chapter as amended (amended sections listed below) |
|||||||||||||||||||||||
| Adopt only those sections that are listed below |
|||||||||||||||||||||||
| Chapter/Section | |||||||||||||||||||||||
This state agency does not adopt sections identified with the following symbol: The Office of the State Fire Marshal’s adoption of this chapter or individual sections is applicable to structures regulated by other state agencies pursuant to Section 1.11.0.
2022 CALIFORNIA PLUMBING CODE 297
298 2022 CALIFORNIA PLUMBING CODE
CHAPTER 14
FIRESTOP PROTECTION
1401.0 General.¶
1402.0 Construction Documents.¶
1403.0 Installation.¶
1404.0 Combustible Piping Installations.¶
1405.0 Noncombustible Piping Installations.¶
1406.0 Required Inspection.¶
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — California Plumbing Code (Title 24, Part 5)
- Chapter 1 — GENERAL CODE PROVISIONS
- Chapter 2 — DEFINITIONS
- Chapter 3 — GENERAL REGULATIONS
- Chapter 4 — PLUMBING FIXTURES AND FIXTURE FITTINGS
- Chapter 5 — WATER HEATERS
- Chapter 6 — WATER SUPPLY AND DISTRIBUTION
- Chapter 7 — SANITARY DRAINAGE
- Chapter 8 — INDIRECT WASTES
- Chapter 9 — VENTS
- Chapter 10 — TRAPS AND INTERCEPTORS
- Chapter 11 — STORM DRAINAGE
- Chapter 12 — FUEL GAS PIPING
- Chapter 13 — HEALTH CARE FACILITIES AND MEDICAL GAS AND MEDICA…
▸Chapter 14 — FIRESTOP PROTECTION
Overview- 1401.1 Applicability. Piping penetrations of required fireresi…
- 1402.1 Penetrations. Construction documents shall indicate wit…
- 1403.1 Materials. Firestop systems shall be installed in
- 1404.1 General Requirements. Combustible piping
- 1404.2 Fire-Resistance Rating. Where penetrating a fireresista…
- 1404.3 Firestop Systems. Penetrations shall be protected
- 1404.4 Connections. Where piping penetrates a rated
- 1404.5 Insulation and Coverings. Insulation and coverings on o…
- 1404.6 Sleeves. Where sleeves are used, the sleeves shall
- 1405.1 General Requirements. Noncombustible piping
- 1405.2 Fire-Resistance Rating. Where penetrating a fireresista…
- 1405.3 Firestop Systems. Penetrations shall be protected
- 1405.4 Connections. Where piping penetrates a rated
- 1405.5 Unshielded Couplings. Unshielded couplings
- 1405.6 Sleeves. Where sleeves are used, the sleeves shall
- 1405.7 Insulation and Coverings. Insulation and coverings on o…
- 1406.1 General. Prior to being concealed, piping penetrations …
- 1406.2 Examination. The Authority Having Jurisdiction
- 1406.3 Penetrations. The Authority Having Jurisdiction
- 1406.4 Field Installations. The Authority Having Jurisdiction …
- Chapter 15 — ALTERNATE WATER SOURCES FOR NONPOTABLE APPLICATIONS
- Chapter 16 — NONPOTABLE RAINWATER CATCHMENT SYSTEMS
- Chapter 17 — REFERENCED STANDARDS
- Appendix A — RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYS…
- Appendix B — EXPLANATORY NOTES ON COMBINATION WASTE AND VENT S…
- Appendix C — ALTERNATE PLUMBING SYSTEMS
- Appendix D — SIZING STORM WATER DRAINAGE SYSTEMS
- Appendix E — MANUFACTURED/MOBILE HOME PARKS AND RECREATIONAL V…
- Appendix F — FIREFIGHTER BREATHING AIR REPLENISHMENT SYSTEMS
- Appendix G — SIZING OF VENTING SYSTEMS
- Appendix H — PRIVATE SEWAGE DISPOSAL SYSTEMS
- Appendix I — INSTALLATION STANDARDS
- Appendix J — COMBINATION OF INDOOR AND OUTDOOR COMBUSTION AND …
- Appendix K — POTABLE RAINWATER CATCHMENT SYSTEMS
- Appendix L — SUSTAINABLE PRACTICES
- Appendix M — PEAK WATER DEMAND CALCULATOR
- Appendix N — IMPACT OF WATER TEMPERATURE ON THE POTENTIAL FOR …