Chapter 3 — GENERAL REGULATIONS
310.9 [OSHPD 1, 1R, 2, 3, 4 & 5] Drainage piping over
California Plumbing Code (Title 24, Part 5) · 2019 edition · updated 2026-09-10 · California
Italicized text is a California amendment to the model code, as printed in the official publication.
operating and delivery rooms, nurseries, food preparation centers, food-serving facilities, food storage areas, and other sensitive areas shall be kept to a minimum and shall not be exposed. Special precautions shall be taken to protect these areas from possible leakage from necessary overhead drainage piping systems. Piping over switchboards, panel boards, and motor control centers are subject to restrictions of the California Electrical Code where applicable.
2019 CALIFORNIA PLUMBING CODE 49
GENERAL REGULATIONS any other purpose or distributed to any other persons or parti es.
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — California Plumbing Code (Title 24, Part 5)
- Chapter 1 — GENERAL CODE PROVISIONS
- Chapter 2 — DEFINITIONS
▸Chapter 3 — GENERAL REGULATIONS
Overview- 301.2 Minimum Standards. Pipe, pipe fittings, traps, fixtures,…
- 301.3 Alternate Materials and Methods of Construc-
- 301.4 Flood Hazard Areas. Plumbing systems shall be
- 301.5 Alternative Engineered Design. An alternative
- 301.6 One- and Two-Family Dwellings. [HCD 1] The
- 303.0 Disposal of Liquid Waste.303.1 General. It shall be unla…
- 304.0 Connections to Plumbing System Required.304.1 General. P…
- 305.0 Damage to Drainage System or Public Sewer.305.1 Unlawful…
- 306.2 Safe Discharge. Sewage or other waste from a
- 307.2 Ownership. No subdivision, sale, or transfer of ownershi…
- 309.2 Concealing Imperfections. It is unlawful to conceal crac…
- 309.3 Burred Ends. Burred ends of pipe and tubing shall
- 309.4 Installation Practices. Plumbing systems shall be
- 309.5 Sound Transmission. Plumbing piping systems
- 310.2 Drainage and Vent Piping. No drainage or vent
- 310.3 Waste Connection. No waste connection shall be
- 310.4 Use of Vent and Waste Pipes. Except as hereinafter provi…
- 310.5 Obstruction of Flow. No fitting, fixture and piping
- 310.6 Dissimilar Metals. Except for necessary valves,
- 310.7 Direction of Flow. Valves, pipes, and fittings shall be
- 310.8 Screwed Fittings. Screwed fittings shall be ABS,
- 310.9 [OSHPD 1, 1R, 2, 3, 4 & 5] Drainage piping over
- 310.10 [OSHPD 1, 1R, 3, 4 & 5] Floor drains, waste traps
- 310.11 [SFM] For applications listed in Section 1.11.0 reg-
- 310.12 [OSHPD 1, 1R, 2, 4 & 5] Services/Systems andUtilities. …
- 310.13 Telephone and Data Equipment Rooms[OSHPD 1, 1R, 4 & 5].…
- 311.0 Independent Systems.311.1 General. The drainage system o…
- 312.2 Installation. Piping in connection with a plumbing
- 312.3 Building Sewer and Drainage Piping. No building sewer or…
- 312.4 Corrosion, Erosion, and Mechanical Damage. Piping subjec…
- 312.5 Protectively Coated Pipe. Protectively coated pipe
- 312.6 Freezing Protection. No water, soil, or waste pipe
- 312.7 Fire-Resistant Construction. Piping penetrations
- 312.8 Waterproofing of Openings. Joints at the roof
- 312.9 Steel Nail Plates. Plastic and copper or copper alloy
- 312.10 Sleeves. Sleeves shall be provided to protect piping th…
- 312.11 Structural Members. A structural member weakened or imp…
- 312.12 Rodentproofing. Strainer plates on drain inlets
- 313.2 Material. Hangers and anchors shall be of sufficient
- 313.3 Suspended Piping. Suspended piping shall be supported at…
- 313.4 Alignment. Piping shall be supported in such a manner as…
- 313.5 Underground Installation. Piping in the ground
- 313.6 Hanger Rod Sizes. Hanger rod sizes shall be not
- 314.2 Tunneling and Driving. Tunneling and driving shall
- 314.3 Open Trenches. Excavations required to be made
- 314.4 Excavations. Excavations shall be completely backfilled …
- 313.7 Gas Piping. Gas piping shall be supported by metal
- 313.8 [OSHPD 1, 1R, 2, 3, 4 & 5] Refer to Title 24, Part 2
- 315.2 Prohibited Joints and Connections. A fitting or
- 317.0 Food-Handling Establishments.317.1 General. Food or drin…
- 318.2 Pressure Tests (10 psi or less). Required pressure tests…
- 318.3 Pressure Tests (greater than 10 psi to 100 psi).
- 318.4 Pressure Tests (exceeding 100 psi). Required
- 318.5 Pressure Range. Test gauges shall have a pressure
- 321.0 Essential Plumbing Provisions. [OSHPD 1, 1R,2, 3 (surgic…
- Chapter 4 — PLUMBING FIXTURES AND FIXTURE FITTINGS
- Chapter 5 — WATER HEATERS
- Chapter 6 — WATER SUPPLY AND DISTRIBUTION
- Chapter 7 — SANITARY DRAINAGE
- Chapter 8 — INDIRECT WASTES
- Chapter 9 — VENTS
- Chapter 10 — TRAPS AND INTERCEPTORS
- Chapter 11 — STORM DRAINAGE
- Chapter 12 — FUEL GAS PIPING
- Chapter 13 — HEALTH CARE FACILITIES AND MEDICAL GAS AND MEDICA…
- Chapter 14 — FIRESTOP PROTECTION
- Chapter 15 — ALTERNATE WATER SOURCES FOR NONPOTABLE APPLICATIONS
- Chapter 16 — NONPOTABLE RAINWATER CATCHMENT SYSTEMS
- Chapter 17 — REFERENCED STANDARDS
- Appendix A — RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYS…
- Appendix B — EXPLANATORY NOTES ON COMBINATION WASTE AND VENT S…
- Appendix C — ALTERNATE PLUMBING SYSTEMS
- Appendix D — SIZING STORM WATER DRAINAGE SYSTEMS
- Appendix E — MANUFACTURED/MOBILE HOME PARKS AND RECREATIONAL V…
- Appendix F — FIREFIGHTER BREATHING AIR REPLENISHMENT SYSTEMS
- Appendix G — SIZING OF VENTING SYSTEMS
- Appendix H — PRIVATE SEWAGE DISPOSAL SYSTEMS
- Appendix I — INSTALLATION STANDARD FOR PEX TUBING SYSTEMS FOR …
- Appendix J — COMBINATION OF INDOOR AND OUTDOOR COMBUSTION AND …
- Appendix K — POTABLE RAINWATER CATCHMENT SYSTEMS
- Appendix L — SUSTAINABLE PRACTICES
- Appendix M — PEAK WATER DEMAND CALCULATOR