Chapter 3 — GENERAL REGULATIONS
301.4 Flood Hazard Areas. Plumbing systems shall be
California Plumbing Code (Title 24, Part 5) · 2019 edition · updated 2026-09-10 · California
Italicized text is a California amendment to the model code, as printed in the official publication.
located above the elevation in accordance with the building code for utilities and attendant equipment or the elevation of the lowest floor, whichever is higher.
However, the exercise of this discretionary approval by the Authority Having Jurisdiction shall have no effect beyond the jurisdictional boundaries of said Authority Having Jurisdiction. An alternate material or method of construction so approved shall not be considered as in accordance with the requirements, intent, or both of this code for a purpose other than that granted by the Authority Having Jurisdiction where the submitted data does not prove equivalency.
301.3.1 Testing. The Authority Having Jurisdiction shall have the authority to require tests, as proof of equivalency.
2019 CALIFORNIA PLUMBING CODE 47
GENERAL REGULATIONS any other purpose or distributed to any other persons or parti es.
Exception: Plumbing systems shall be permitted to be located below the elevation in accordance with the building code for utilities and attendant equipment or the elevation of the lowest floor, whichever is higher, provided that the systems are designed and installed to prevent water from entering or accumulating within their components, and the systems are constructed to resist hydrostatic and hydrodynamic loads and stresses, including the effects of buoyancy, during the occurrence of flooding to such elevation.
301.4.1 Coastal High Hazard Areas. Plumbing systems in buildings located in coastal high hazard areas shall be in accordance with the requirements of Section 301.4, and plumbing systems, pipes, and fixtures shall not be mounted on or penetrate through walls that are intended to breakaway under flood loads in accordance with the California Building Code or California Resi- dential Code .
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — California Plumbing Code (Title 24, Part 5)
- Chapter 1 — GENERAL CODE PROVISIONS
- Chapter 2 — DEFINITIONS
▸Chapter 3 — GENERAL REGULATIONS
Overview- 301.2 Minimum Standards. Pipe, pipe fittings, traps, fixtures,…
- 301.3 Alternate Materials and Methods of Construc-
- 301.4 Flood Hazard Areas. Plumbing systems shall be
- 301.5 Alternative Engineered Design. An alternative
- 301.6 One- and Two-Family Dwellings. [HCD 1] The
- 303.0 Disposal of Liquid Waste.303.1 General. It shall be unla…
- 304.0 Connections to Plumbing System Required.304.1 General. P…
- 305.0 Damage to Drainage System or Public Sewer.305.1 Unlawful…
- 306.2 Safe Discharge. Sewage or other waste from a
- 307.2 Ownership. No subdivision, sale, or transfer of ownershi…
- 309.2 Concealing Imperfections. It is unlawful to conceal crac…
- 309.3 Burred Ends. Burred ends of pipe and tubing shall
- 309.4 Installation Practices. Plumbing systems shall be
- 309.5 Sound Transmission. Plumbing piping systems
- 310.2 Drainage and Vent Piping. No drainage or vent
- 310.3 Waste Connection. No waste connection shall be
- 310.4 Use of Vent and Waste Pipes. Except as hereinafter provi…
- 310.5 Obstruction of Flow. No fitting, fixture and piping
- 310.6 Dissimilar Metals. Except for necessary valves,
- 310.7 Direction of Flow. Valves, pipes, and fittings shall be
- 310.8 Screwed Fittings. Screwed fittings shall be ABS,
- 310.9 [OSHPD 1, 1R, 2, 3, 4 & 5] Drainage piping over
- 310.10 [OSHPD 1, 1R, 3, 4 & 5] Floor drains, waste traps
- 310.11 [SFM] For applications listed in Section 1.11.0 reg-
- 310.12 [OSHPD 1, 1R, 2, 4 & 5] Services/Systems andUtilities. …
- 310.13 Telephone and Data Equipment Rooms[OSHPD 1, 1R, 4 & 5].…
- 311.0 Independent Systems.311.1 General. The drainage system o…
- 312.2 Installation. Piping in connection with a plumbing
- 312.3 Building Sewer and Drainage Piping. No building sewer or…
- 312.4 Corrosion, Erosion, and Mechanical Damage. Piping subjec…
- 312.5 Protectively Coated Pipe. Protectively coated pipe
- 312.6 Freezing Protection. No water, soil, or waste pipe
- 312.7 Fire-Resistant Construction. Piping penetrations
- 312.8 Waterproofing of Openings. Joints at the roof
- 312.9 Steel Nail Plates. Plastic and copper or copper alloy
- 312.10 Sleeves. Sleeves shall be provided to protect piping th…
- 312.11 Structural Members. A structural member weakened or imp…
- 312.12 Rodentproofing. Strainer plates on drain inlets
- 313.2 Material. Hangers and anchors shall be of sufficient
- 313.3 Suspended Piping. Suspended piping shall be supported at…
- 313.4 Alignment. Piping shall be supported in such a manner as…
- 313.5 Underground Installation. Piping in the ground
- 313.6 Hanger Rod Sizes. Hanger rod sizes shall be not
- 314.2 Tunneling and Driving. Tunneling and driving shall
- 314.3 Open Trenches. Excavations required to be made
- 314.4 Excavations. Excavations shall be completely backfilled …
- 313.7 Gas Piping. Gas piping shall be supported by metal
- 313.8 [OSHPD 1, 1R, 2, 3, 4 & 5] Refer to Title 24, Part 2
- 315.2 Prohibited Joints and Connections. A fitting or
- 317.0 Food-Handling Establishments.317.1 General. Food or drin…
- 318.2 Pressure Tests (10 psi or less). Required pressure tests…
- 318.3 Pressure Tests (greater than 10 psi to 100 psi).
- 318.4 Pressure Tests (exceeding 100 psi). Required
- 318.5 Pressure Range. Test gauges shall have a pressure
- 321.0 Essential Plumbing Provisions. [OSHPD 1, 1R,2, 3 (surgic…
- Chapter 4 — PLUMBING FIXTURES AND FIXTURE FITTINGS
- Chapter 5 — WATER HEATERS
- Chapter 6 — WATER SUPPLY AND DISTRIBUTION
- Chapter 7 — SANITARY DRAINAGE
- Chapter 8 — INDIRECT WASTES
- Chapter 9 — VENTS
- Chapter 10 — TRAPS AND INTERCEPTORS
- Chapter 11 — STORM DRAINAGE
- Chapter 12 — FUEL GAS PIPING
- Chapter 13 — HEALTH CARE FACILITIES AND MEDICAL GAS AND MEDICA…
- Chapter 14 — FIRESTOP PROTECTION
- Chapter 15 — ALTERNATE WATER SOURCES FOR NONPOTABLE APPLICATIONS
- Chapter 16 — NONPOTABLE RAINWATER CATCHMENT SYSTEMS
- Chapter 17 — REFERENCED STANDARDS
- Appendix A — RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYS…
- Appendix B — EXPLANATORY NOTES ON COMBINATION WASTE AND VENT S…
- Appendix C — ALTERNATE PLUMBING SYSTEMS
- Appendix D — SIZING STORM WATER DRAINAGE SYSTEMS
- Appendix E — MANUFACTURED/MOBILE HOME PARKS AND RECREATIONAL V…
- Appendix F — FIREFIGHTER BREATHING AIR REPLENISHMENT SYSTEMS
- Appendix G — SIZING OF VENTING SYSTEMS
- Appendix H — PRIVATE SEWAGE DISPOSAL SYSTEMS
- Appendix I — INSTALLATION STANDARD FOR PEX TUBING SYSTEMS FOR …
- Appendix J — COMBINATION OF INDOOR AND OUTDOOR COMBUSTION AND …
- Appendix K — POTABLE RAINWATER CATCHMENT SYSTEMS
- Appendix L — SUSTAINABLE PRACTICES
- Appendix M — PEAK WATER DEMAND CALCULATOR