Chapter 3 — GENERAL REGULATIONS
317.1 General.
California Plumbing Code (Title 24, Part 5) · 2025 edition · updated 2026-09-12 · California
Italicized text is a California amendment to the model code, as printed in the official publication.
Food or drink shall not be stored, prepared, or displayed beneath soil or drainpipes unless those areas are protected against leakage or condensation from such pipes reaching the food or drink as described below. Where building design requires that soil or drainpipes be located over such areas, the installation shall be made with the least possible number of joints and shall be installed to connect to the nearest adequately sized vertical stack with the provisions as follows:
(1) Openings through floors over such areas shall be sealed watertight to the floor construction.
(2) Floor and shower drains installed above such areas shall be equipped with integral seepage pans.
(3) Soil or drainpipes shall be of an approved material as listed in Chapter 17 and Section 701.2. Materials shall comply with established standards. Cleanouts shall be extended through the floor construction above.
(4) Piping subject to operation at temperatures that will form condensation on the exterior of the pipe shall be thermally insulated.
(5) Where pipes are installed in ceilings above such areas, the ceiling shall be of the removable type or shall be pro
vided with access panels to form a ready access for inspection of piping.
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — California Plumbing Code (Title 24, Part 5)
- Chapter 1 — GENERAL CODE PROVISIONS
- Chapter 2 — DEFINITIONS
▸Chapter 3 — GENERAL REGULATIONS
Overview- 301.1 Applicability.
- 301.2 Minimum Standards.
- 301.3 Alternate Materials and Methods of Construction Equivale…
- 301.4 Flood Hazard Areas.
- 301.5 Alternative Engineered Design.
- 301.6 Tall Wood (Mass Timber) Buildings.
- 301.7 One- and Two-Family Dwellings. [HCD 1]
- 301.8 OSHPD 1R. [OSHPD 1R]
- 302.1 General.
- 303.1 General.
- 304.1 General.
- 305.1 Unlawful Practices.
- 306.1 Detrimental Wastes.
- 306.2 Safe Discharge.
- 307.1 System.
- 307.2 Ownership.
- 308.1 General.
- 309.1 Engineering Practices.
- 309.2 Concealing Imperfections.
- 309.3 Burred Ends.
- 309.4 Installation Practices.
- 309.5 Sound Transmission.
- 309.6 Dead Legs.
- 310.1 Fittings.
- 310.2 Drainage and Vent Piping.
- 310.3 Waste Connection.
- 310.4 Use of Vent and Waste Pipes.
- 310.5 Obstruction of Flow.
- 310.6 Dissimilar Metals.
- 310.7 Direction of Flow.
- 310.8 Screwed Fittings.
- 310.9 Female Plastic Connections.
- 310.10 ABS and PVC Transition Joints.
- 310.11 [OSHPD 1, 2, 3, 4 & 5]
- 310.12 [OSHPD 1, 3, 4 & 5]
- 310.13 [SFM]
- 310.14 Services/Systems and Utilities. [OSHPD 1, 2, 4
- 310.15 Telephone and Data Equipment Rooms.
- 311.1 General.
- 312.1 General.
- 312.2 Installation.
- 312.3 Building Sewer and Drainage Piping.
- 312.4 Corrosion, Erosion, and Mechanical Damage.
- 312.5 Protectively Coated Pipe.
- 312.6 Freezing Protection.
- 312.7 Fire-Resistant Construction.
- 312.8 Waterproofing of Openings.
- 312.9 Steel Nail Plates.
- 312.10 Sleeves.
- 312.11 Structural Members.
- 312.12 Rodentproofing.
- 313.1 General.
- 313.2 Material.
- 313.3 Suspended Piping.
- 313.4 Alignment.
- 313.5 Underground Installation.
- 313.6 Hanger Rod Sizes.
- 313.7 Gas Piping.
- 313.8 [OSHPD 1, 2, 3, 4 & 5]
- 314.1 Trenches.
- 314.2 Tunneling and Driving.
- 314.3 Open Trenches.
- 314.4 Excavations.
- 315.1 Unions.
- 315.2 Prohibited Joints and Connections.
- 316.1 General.
- 317.1 General.
- 318.1 General.
- 318.2 Pressure Tests (10 psi or less).
- 318.3 Pressure Tests (greater than 10 psi to 100 psi).
- 318.4 Pressure Tests (exceeding 100 psi).
- 318.5 Pressure Range.
- 319.1 General.
- 320.1 General.
- 323.0 Plumbing Equipment Schedules. [OSHPD 1, 2,
- Chapter 4 — PLUMBING FIXTURES AND FIXTURE FITTINGS
- Chapter 5 — WATER HEATERS
- Chapter 6 — WATER SUPPLY AND DISTRIBUTION
- Chapter 7 — SANITARY DRAINAGE
- Chapter 8 — INDIRECT WASTES
- Chapter 9 — VENTS
- Chapter 10 — TRAPS AND INTERCEPTORS
- Chapter 11 — STORM DRAINAGE
- Chapter 12 — FUEL GAS PIPING
- Chapter 13 — HEALTH CARE FACILITIES AND MEDICAL GAS AND MEDICA…
- Chapter 14 — FIRESTOP PROTECTION
- Chapter 15 — ALTERNATE WATER SOURCES FOR NONPOTABLE APPLICATIONS
- Chapter 16 — NONPOTABLE RAINWATER CATCHMENT SYSTEMS
- Chapter 17 — REFERENCED STANDARDS
- Appendix A — RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYS…
- Appendix B — EXPLANATORY NOTES ON COMBINATION WASTE AND VENT S…
- Appendix C — ALTERNATE PLUMBING SYSTEMS
- Appendix D — SIZING STORM WATER DRAINAGE SYSTEMS
- Appendix E — MANUFACTURED/MOBILE HOME PARKS AND RECREATIONAL V…
- Appendix F — FIREFIGHTER BREATHING AIR REPLENISHMENT SYSTEMS
- Appendix G — SIZING OF VENTING SYSTEMS
- Appendix H — PRIVATE SEWAGE DISPOSAL SYSTEMS
- Appendix I — INSTALLATION STANDARDS
- Appendix J — COMBINATION OF INDOOR AND OUTDOOR COMBUSTION AND …
- Appendix K — POTABLE RAINWATER CATCHMENT SYSTEMS
- Appendix L — SUSTAINABLE PRACTICES
- Appendix M — PEAK WATER DEMAND CALCULATOR
- Appendix N — IMPACT OF WATER TEMPERATURE ON THE POTENTIAL FOR …
- Appendix O — NON-SEWERED SANITATION SYSTEMS
- Appendix P — PROFESSIONAL QUALIFICATIONS
- Appendix Q — INDOOR HORTICULTURAL FACILITIES
- Appendix R — TINY HOUSES
- Appendix S — ONSITE STORMWATER TREATMENT SYSTEMS